Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “metering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Data release for A search for extremely-high-energy neutrinos and first constraints on the ultra-high-energy cosmic-ray proton fraction with IceCube

<h1 id="summary">Summary</h1> <p>Title: Data Release for A search for extremely-high-energy neutrinos and first constraints on the ultra-high-energy cosmic-ray proton fraction with IceCube</p> <p>The IceCube observatory analyzed 12.6 years of data in search of extremely-high-energy (EHE) neutrinos above 5 PeV. The resultant limit of the search (Fig 1), and the effective area of the event selection (Fig 7), are provided in this data release.</p> <h1 id="contents">Contents</h1> <ul> <li><p>README file: this file</p> </li> <li><p><code>differential_limit_and_sensitivity.csv</code>: a comma separated value file, giving the observed experimental differential limit, and sensitivity, of the search as a function of neutrino energy. This is the content of Fig 1 in the paper. The first column is the neutrino energy in GeV. The second column is the limit in units of GeV/cm2/s/sr. The third column is the sensitivity in units of GeV/cm2/s/sr.</p> </li> <li><p><code>effective_area.csv</code>: a comma separated value file, giving the effective area of the search as a function of energy. This is the content of Fig 7 in the paper. The first column is the neutrino energy in GeV. The second column is the total effective area of the search, summed across neutrino flavors, and averaged across neutrinos and antineutrinos, in meters-squared. The third column is the effective area of the search for the average of electron neutrino and electron antineutrinos in units of meters-squared. The fourth column is the same as the third, but for muon-flavor neutrinos. The fifth column is the same as the third and fourth, but for tau-flavor neutrinos.</p> </li> <li><p><code>demo.py</code>: a short python script to demonstrate how to read the files. Run like <code>python demo.py</code>. A standard base python installation is sufficient, as the only dependencies are numpy and matplotlib.</p> </li> </ul> <h1 id="contacts">Contacts</h1> <p>For any questions about this data release, please write to analysis@icecube.wisc.edu</p>

Astronomy and Astrophysics↗

Electrical Fault and Power Quality Detection Algorithms and Customer-Owned DERs Monitoring with a Cyber Grid Guard System and DLT

In this study, the electrical fault and power quality detection algorithms and customer-owned DERs monitoring use cases were implemented, with a Cyber Grid Guard system and DLT. Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substations, and are associated with customer-owned distributed energy resources (DERs). Data from these IEDs, such as power meters and protection relays, must be kept confidential and of high integrity. Blockchain technology has the potential to increase microgrid resilience by enhancing data sharing security. The growing use of IEDs and customer-owned renewable energy sources (DERs) may make it necessary to connect Distributed Ledger Technology (DLT) with power system applications. We implemented the electrical faulted phase detection and power quality monitoring algorithms with a Cyber Grid Guard (CGG) system using DLT. In addition, the DERs (wind turbine farms) use case and protective relay cyber-event tests were assessed, by using the CGG system with DLT. In the experimental model, the testbed was created by using a real-time simulator and CGG system with power meters/ protective relays in the loop. The data collected from the CGG system and IEDs were compared with the same time stamp source. These results showed the successful assessment of protection, control and monitoring applications using a CGG system with DLT. In the future, power system applications for the ESGT with DERs and the CGG system will be based on executing smart contracts between electrical utilities and customer-owned DERs.

Piesciorovsky, Emilio↗

Systems and methods for revocation management in an AMI network

Systems and methods for certificate revocation management for advanced metering infrastructure networks are provided. An accumulation manager can be used to accumulate certificate revocation list (CRL) information and determine an accumulator value and a proof value based on the accumulated CRL information using a plurality of functions. These values can be sent on to smart meters, which can then use them for authentication purposes.

Cebe, Mumin↗

Storage Futures Study - Distributed Solar and Storage Outlook: Methodology and Scenarios

This presentation discusses the fourth report in NREL’s Storage Futures Study (SFS) publications. The SFS is a multiyear research project that explores the role and impact of energy storage in the evolution and operation of the U.S. power sector. The SFS is designed to examine the potential impact of energy storage technology advancement on the deployment of utility-scale storage and the adoption of distributed storage, and the implications for future power system infrastructure investment and operations. This report describes the expanded capabilities of the Distributed Generation Market Demand (dGen) model to analyze the economics of distributed (behind-the-meter) PV paired with battery storage systems and presents projections of adoption for the contiguous United States out to 2050 under a range of scenarios. These scenarios use technology cost and performance assumptions consistent with the National Renewable Energy Laboratory’s 2020 Standard Scenarios paired with updated battery cost projections and existing policies. Additional scenarios evaluate sensitivities to the value of backup power and DER compensation mechanisms, collectively characterizing the future potential for behind-the-meter storage and identifying key drivers of adoption. Adoption projections of DER and battery storage at high spatial and temporal resolution, as presented in this report, can enable informed planning of technical infrastructure that can help planners capture the benefits and mitigate challenges to support the ongoing trend toward distributed electricity generation.

backup power↗

Wind Turbine Blade Finishing Automation: Robotic Toolpath Generation

Wind turbine blades are now over 100 meters long and can reach heights of several meters while in the finishing area of the factory. Because of this, automation should be used to lower the manufacturing cost and make the process safer for blade manufacturing technicians. This session will present a novel method that generates a six degree of freedom robotic toolpath with 3D cameras for the finishing of wind turbine blades to drive down the levelized cost and make wind energy even more competitive in the utility scale energy generation industry.

3d imaging↗

System and method for characterization of retrofit opportunities in building using data from communicating thermostats

Systems and methods for characterization of retrofit opportunities are described. The methods may comprise computing, using at least one computing device disposed remote from a building and based at least in part on heating, ventilation and air conditioning (HVAC) runtime data associated with the building, one or more thermal characteristics of the building. In some embodiments, a model-predicted indoor temperature may be fitted against thermal data measured by a thermostat at the building. The thermal characteristic of the building may comprise a thermal insulation, an air leakage rate and/or an HVAC efficiency. The method may be used to determine, using the at least one computing device, suitability of the building for a retrofit opportunity to improve energy efficiency of the building. Determining the suitability may comprise evaluating the one or more thermal characteristics. The HVAC runtime data may be computed based on data received from a thermostat or a meter, such as an electric or a gas meter.

Zeifman, Michael↗

Study of Classifiers for U-235 Source Signatures Using Gamma Spectral Measurements

Signatures associated with low-level U-235 sources are studied from a classification analytics perspective, using NaI gamma-ray spectral measurements from detectors located at various distances from the source. Data sets collected at a shielded facility are utilized, wherein the source is introduced via a conduit into a formation of 21 NaI detectors deployed over 6 x 6 meters area in a formation of two concentric circles and one spiral. The activity levels in the spectral regions associated with potential U-235 signatures are estimated as counts at 1 second intervals, and are used as features to train classifiers for detecting the presence of the source. Eight different classifiers are trained and tested using the background and source measurements collected over multiple experimental runs. As expected, the classifier performance improved overall as measurements from the detectors closer to source are used, but also revealed unexpectedly low performance by two detectors that are identically produced and configured as others. Six of eight classifiers have an overall comparable performance, for example, three of them achieved zero training error and 99% detection at 4% false alarm rate for a detector located 1.3 meters away from the source. Also, larger training sets led to improved classification performance across all classifiers, and interestingly, the classifiers with the minimum training error did not necessarily achieve the highest classification performance on test data.

Rao, Nageswara↗

Recent Improvements in PV+Battery Modeling in NREL's System Advisor Model

This poster covers recent updates to the NREL System Advisor Model's battery model that can be coupled to the PV model to add value to both front of meter and behind the meter systems. Topics include new dispatch algorithms focusing on smoothing the output of a PV plant to meet ramp rate requirements and responding to price signals to maximize system revenue, validated battery lifetime models, grid outage simulations and resiliency metrics, and the new levelized cost of storage (LCOS) metric. We will also share preliminary results from NREL analysis projects using these features.

battery↗

2021 Prototype Manufacture and Installation Awardee: Pecos Wind Power, Inc.

Through the 2021 Competitiveness Improvement Project (CIP), Pecos Wind Power will manufacture a prototype of its 85-kilowatt (kW) horizontal-axis distributed wind turbine, the PW85, a new wind turbine that began development in 2017 when the company was founded. The PW85 wind turbine includes an industry-leading rotor diameter (30 meters) and full-span variable pitch blades to target a levelized cost of energy (LCOE) of $0.103/kilowatt-hour in low annual wind speeds (6 meters per second). This is 55% lower than the average small wind turbine project installed in 2018. The goal of this project is to spur the development of increasingly lower-cost, high-capacity-factor distributed wind turbines. As a result, Pecos Wind Power will manufacture and install wind turbines that increase the geographic area in which distributed wind power is cost competitive with retail-priced electricity and other distributed energy resources - primarily solar energy.

CIP↗

Connecting Electric Vehicle Charging Infrastructure to Commercial Buildings

Electric vehicles (EVs) are growing in popularity and gaining meaningful market share with record sales year over year in the last decade. EV charging equipment, also known as EV chargers (EVC) or EV supply equipment (EVSE), must proportionally match the growing number of new EVs on the road for a comparable experience to gas-powered vehicles. The majority of EV charging currently happens at residential buildings. However, demand for EV charging at commercial buildings will significantly increase with wider mainstream EV adoption and as businesses return to more normal operation following COVID-19 pandemic disruptions. Charging equipment can include various sub-systems like power conditioning module, control software, safety devices, metering, communication, cooling, connectors, and its wiring. EV charging at commercial buildings could be used for public, workplace, and commercial fleet charging. This document aims to describe how EVC can be connected to commercial buildings, including considerations for facility managers, and the effects that charging will have on the buildings electrical distribution system. More specifically, this resource provides an overview of: understanding EV charging basics: how charging equipment connects to the building and to EVs; required infrastructure updates needed at the building site to connect EVC to existing distribution systems; network strategies for cost-effective operation; metering and utility considerations for billing and incentives; charging equipment ownership options; future trends in EVC connection to buildings.

ADVANCED PROPULSION SYSTEMS,ENERGY CONSERVATION, C↗

The design and test results of A Giga-Bit Cable Receiver (GBCR) for the ATLAS Inner Tracker Pixel Detector

This paper presents the design and test results of a Gigabit Cable Receiver ASIC called GBCR for the HL-LHC upgrade of the ATLAS Inner Tracker (ITk) pixel detector. Three prototypes (GBCR1, GBCR2, and GBCR3) have been designed in the CERN-identified 65 nm CMOS technology. GBCR receives seven (GBCR2) or six (GBCR3) channels (RX) each at 1.28 Gbps from the front-end readout chip RD53B via flex cables up to 1 meter and Twinax cables up to 5 meters and sends the equalized and retimed signals to lpGBT. Both GBCR2 and GBCR3 ASICs have two transmitting channels (TX) that pre-emphasize the signals from lpGBT before sending them to RD53B through the same cables. No Single-Event Upset (SEU) is observed in any tested channels of GBCR2 in a 400 MeV proton beam. The extrapolated bit error rate for the future HL-LHC application is below 8*10^(-16), significantly below the specified BER criterion. GBCR3 is designed to improve the immunity to single-event-upset by applying the Triple Modular Redundancy (TMR) technology to all RX channels. The retimed signals from GBCR3 have less total jitter than those from GBCR2 (35 ps versus 79 ps). Each receiver channel of GBCR3 consumes 75% more power than that of GBCR2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Online Tracking of Two Dominant Inter-Area Modes of Oscillation in the Eastern Interconnection

Reliable power system operation requires that small-signal stability be maintained at all times. Mode meters are measurement-based tools that provide operators with situational awareness of the system's stability margin. They operate by continually tracking the inter-area modes of oscillation that govern small-signal stability. This paper reports on the deployment of mode meters for online monitoring of two dominant modes of oscillation in the United States' Eastern Interconnection (EI). The use of measurements from system operators across the interconnection to provide continuous tracking is novel in the EI. Results from over four months of analysis reveal diurnal patterns in the modes and demonstrate that they can be tracked through a variety of system conditions. The results from this study continue to build an understanding of the EI's modes that will inform future modeling and monitoring efforts.

Follum, James D.↗

Variable Resource Resilience: How Systems Experience Increased Resilience from Variable and Hybrid Resources

Variable resources like wind and solar are often seen as detriments to system resilience rather than benefits because they may not be available with the capacities or services required during a high-impact low-frequency (HILF) event, whether that is a physical threat, natural disaster, or cyber attack. However, resilience goals and metrics are inadequate for electric energy delivery systems with inverter-based resources. Examination of this topic reveals that renewable resources are well suited to combat many resilience hazards due to local resource availability. Metrics that demonstrate the resilience value of variable resources are presented and categorized for resource (wind, solar, storage, hybrid) and installation type (bulk utility scale, behind-the-meter, front-of-the-meter, isolated). Distributed and hybrid systems can further enhance resilience benefits my maximizing resource potential for a locality. A case study demonstrating quantitative resilience benefits from wind alone is provided for St. Mary's, AK, which concludes that hundreds of thousands of dollars are saved by the addition of a wind turbine in the face of realistic fuel shortage and extreme winter weather scenarios.

17 WIND ENERGY↗

The Fermilab SSR1 and HB650 Synoptic and EPICS remote cryogenic control system

The 325MHz Single Spoke Resonator 1 (SSR1) Cryomodule (CM) has a 5.3-meter length, and it has 288-liter liquid helium @ 4.5K mode. The High Beta 650 MHz (HB650) CM contains six elliptical cavity cryomodules, has a 9.9-meter overall length and it has 530-liter liquid helium. The SSR1 and HB650 CM had been tested at Fermilab Cryomodule Test Facility (CMTF). Their cryogenic control system includes the Siemens Process Control System S7-400, Automation Direct DL205 PLC, and remote synoptic HMI/EPICS Phoebus GUI. This paper presents a method which has been successfully used by Fermilab PIP2 IT cryogenic remote on-line, real-time control systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Empirical Validation of UBEM: An Assessment of Bias in Urban Building Energy Modeling for Chicago

Residential and commercial buildings currently account for 30% of total global final energy consumption. Urban-scale building energy modeling (UBEM) can enable scalable investments and unlock building improvements by quantifying energy, demand, emissions, and cost reductions of specific measures or packages for building-specific technologies in large geographic regions. While the sophistication of UBEM data sources and technologies have increased dramatically in the past decade, there remains a knowledge gap for empirical validation and sources of bias between building-specific energy models and measured data at varying geographic scales.As UBEM continues to develop, systemic analysis of accuracy, bias, and limitations of the resulting models is necessary to inform best practices and move toward standardization. These are characterized for the Automatic Building Energy Modeling (AutoBEM) software suite with an initial case study involving metered electricity consumption data from 247,188 buildings in Chicago, Illinois, USA - averaged across years 2019-2021 - compared to the following datasets: (1) the AutoBEM-generated nation-scale Model America version 2 (MAv2) data for 596,064 buildings, (2) tax assessor data for 579,829 buildings, (3) tax assessor data filled with MAv2, and (4) 102 representative dynamic archetypes. The accuracy is reported for every building type and vintage combination, along with multiple sources of bias for unique building descriptors. The AutoBEM simulation workflow produced energy consumption estimates that closely match aggregated metered electricity consumption data for different types of buildings constructed during various time periods at the city scale - with initial normalized mean bias error of 10.9%, and 1.1% after removing outliers. Contribution of statistically significant factors including building type, land use, age, and size to variance in UBEM bias is quantified.

Garg, Ankur↗

Field-Scale Lysimeter Studies of Glass and Cementitious Waste Forms at the Hanford Site - 20392

The Hanford site Integrated Disposal Facility (IDF) will receive waste forms from vitrification activities at the Hanford Waste Treatment and Immobilization Plant (WTP). The waste form inventory to be disposed of at the IDF will consist of vitrified low-activity waste (LAW) in glass forms and solidified (or encapsulated) secondary wastes in cementitious forms. The IDF is a near-surface burial facility located near Hanford's Waste Treatment and Immobilization Plant in the 200 East Area of the site's Central Plateau. An extensive set of laboratory experimental data has been collected to support IDF performance assessment calculations of the eventual degradation of waste forms and mobility of contaminants. This paper describes the start of a field experiment to generate waste-form performance data on a larger scale (tens of centimeters), over a longer duration (five years or more), and under field conditions representative of the IDF. Results from this study are expected to improve model descriptions of contaminant mobility, reduce uncertainties about the representativeness of laboratory results in the IDF performance assessment, improve stakeholder confidence in the safe disposal of treated waste at the IDF, and facilitate the adoption of informed facility designs with the potential to reduce operational costs. A lysimeter test facility near Hanford's 200 West Area has been repurposed to carry out long-term assessments of waste forms buried in sediments excavated from the IDF. The waste forms are buried in large drainage lysimeters, open caissons that are two meters in diameter and three meters deep. Waste forms are buried in up to six locations in each lysimeter. Samplers collect pore water and drainage water beneath the waste forms and air from the pore space adjacent to waste forms. Sensors measure temperature, soil water content, soil water tension, and drainage flux. One lysimeter containing cementitious waste forms and one containing glass waste forms have been completed, along with a control lysimeter (without waste forms). The cementitious waste forms are Cast Stone grout formulations using a liquid secondary waste simulant and a generic Hanford high-salt simulant, as well as a hydrated lime-based grout formulation using a liquid secondary waste simulant. Technetium-99 and iodine-127 were added as tracers to monitor contaminant mobility. Glass waste forms were fabricated in two formulations (LAWA44 and ORLEC28), with rhenium and molybdenum tracers to monitor waste form degradation. The predicted performance of the waste forms in the lysimeters was modeled prior to installation to determine waste form size, tracer concentration/activity, and locations of sensors and samplers. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Using Robotic Manipulators for Radioactive Waste Inspection - 20090

The global nuclear industry has a growing volume of nuclear waste which needs to be scanned, sorted according to its activity and material type, then processed into the correct waste packages for long term storage and disposal. It is vital that there is a detailed understanding of the waste inventory stored in long term waste containers, as knowledge of their contents could predict or prevent any adverse effects in storage. The numerous 'scan and sort' tables which are currently used at many different facilities around the world to sort waste into their correct containers are human operated and require very slow gamma scanning procedures combined with educated guesswork to manually sort the waste. This often leads to excessive conservatisms, with placement of lower activity wastes in higher activity containers, which in turn costs significantly more to store. In the United Kingdom it costs UK Pounds 46 k per cubic meter to store intermediate level waste compared to just UK Pound 2.9 k per cubic meter to store low level waste according to a 2008 Department of Energy and Climate Change report in the UK. A proposed solution to this problem, is the use of a robotic manipulator to automatically inspect the 'scan and sort table' in order to produce an accurate 3D model of the table's waste contents and attach an overlaid radiation map. The radiation map contains spectrometry data and can in consequence be used to distinguish and locate specific radioisotopes. The 3D model should be as accurate as possible in order to allow for a second robot arm with an attached gripper to grasp the objects and place them into their designated long-term storage container. Various scanning procedures are explored in this study including basic raster scanning, adaptive raster scanning and point sampling. The optimal solution will in practice be defined by the required application and activity level of the wastes being inspected. The results presented in this study indicate that it is possible to produce a centimeter accurate 3D model of a mixed assortment of components on a nuclear waste 'scan and sort' table. In addition, it was shown that the waste objects emitting radiation could be accurately identified and located, with an overlaid radiation map. This study is applicable across the nuclear waste management sector. Many of the ideas and concepts developed in this study are applicable in other decommissioning settings for example, dismantling of legacy gloveboxes or routine inspection of nuclear waste packages in storage. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Oil and Natural Gas Development near and beneath Uranium Tailings Cells and Other Remediated Sites - 20358

DOE LM is responsible for maintaining remedies at more than 50 remediated sites that require active long-term surveillance and maintenance (LTS and M). Institutional controls (ICs) were established to limit human and environmental exposures to residual contamination by controlling land use, restricting access to potential hazards, and making the public aware of potential dangers from the residual contamination. ICs for each site were developed based on current and foreseeable conditions; however, these controls should evolve to mitigate potential human health and other environmental risks from unanticipated changes in activities or site conditions. Activities conducted beyond the DOE long-term care boundaries by non-DOE parties may impact the effectiveness of ICs or even the long-term stability of disposal cells and groundwater remedies. Several sites that LM manages or that will transfer to LM for LTS and M are in active oil and gas production basins. The sites are associated with uranium ore milling or nuclear test sites and have been remediated or are in the process of remediation and have no ongoing DOE mission. Particularly since 2005, hydraulic fracturing ('fracking') combined with directional drilling has dramatically increased oil and natural gas (oil/gas) production in the United States, now making it the number one hydrocarbon-producing country. Fracking has allowed production from shale and other rocks of low natural permeability that were historically not considered viable oil/gas resources. Also, because wellbores can now be drilled as many as 5 kilometers or more horizontally, hydrocarbons can be recovered from zones without having access to the surface above them. Drilling activity near Rulison, Colorado, the location of an underground nuclear detonation managed by LM, has raised public concerns that remnant radioactivity in the detonation zone could migrate to producing wells and enter the natural gas distribution system. At sites like the Falls City, Texas, Disposal site, transitioned to LM with a split estate, increased production in the region has resulted in wellbores beneath the long-term care boundary of the site. While the DOE license for Falls City was approved by the NRC in 1997 without the acquisition of the subsurface rights, NRC has raised concerns on whether this activity impacts the integrity of the cell and/or groundwater remedies. In Wyoming, LM is anticipating receiving the license for the Bear Creek site and manages the Spook site, both locations of uranium mill tailings disposal cells. These Wyoming sites are in an active region of major oil and gas development. This change in surrounding land use will require LM to work collaboratively with NRC to address these concerns. At several DOE sites radioactive waste, and often intermixed nonradioactive constituents, is permanently isolated in engineered disposal cells. At other sites, residual contamination can be present in groundwater, blast cavities, and infinite amounts within soil. Areas targeted for oil and gas development at the Texas and Wyoming sites range from depths of 2440 to 3350 meters (8000-11000 feet) below ground surface. When most site remedies were designed, oil and gas development was not considered to be an issue within the site boundary. With the more recent uses of directional drilling, fracking, and associated wastewater injections, the evaluative criteria for incoming sites and ICs for managing long-term protectiveness and regulatory compliance are changing. Although DOE surface ownership was previously thought to be a robust IC to prevent surface and subsurface development, particularly at disposal sites, that may no longer be the case. Whereas the subsurface development at Texas and Wyoming sites is currently occurring at thousands of meters beneath the surface, shallower and direct onsite development would be more of a concern for LM. The energy introduced when a well is hydraulically fractured causes microseismic events (magnitude -2 to 1.0) as the fractures propagate but does not directly cause seismic events (earthquakes) of sufficient magnitude to damage surface structures. Additionally, the extent of the hydraulic fractures is limited to the targeted depths, which are far below the surface. However, earthquakes of sufficient magnitude to damage surface structures have been attributed to the injection of wastewater into disposal wells. States that have experienced these effects have enacted regulations that limit the rate and pressures that wastewater can be injected into disposal wells. Items LM may consider are the need for monitoring the volume of water injected into nearby disposal wells and possibly installing seismic stations at sites most susceptible to damage. While the need to demonstrate that no impact from oil and gas extraction activities on a site groundwater remedy or disposal cells will vary from site to site, LM is assessing risk criteria for this activity. Though LM has not experienced an issue yet at a uranium tailings disposal site, it cannot assume that there will be none, and must address NRC concerns. LM is building on past experiences at other sites and beginning to form new processes with the hope that these concepts can be applied for other future sites. (authors)

04 OIL SHALES AND TAR SANDS↗