Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “mesh”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Cost-effective fabrication of ZnO/g-C3N4 composite film coated stainless steel meshes for visible light responsive photocatalysis

Highlights: • First report on the photocatalytic efficacy of ZnO/g-C{sub 3}N{sub 4} composite thin film coated stainless steel mesh. • A homemade automated tubular nebulizer spray pyrolysis technique is used to deposit the samples. • All supplementary studies (SEM, XPS, FTIR and PL) support the enhancement photocatalytic activity. - Abstract: The ZnO and ZnO/g-C{sub 3}N{sub 4} composite films were deposited on stainless steel meshes having different apertures (370, 500, 780 and 1000 μm) using a simple cost-effective automated tubular nebulizer spray pyrolysis technique for photocatalytic degradation of organic pollutants. Photocatalytic studies were done for the degradation of methylene blue (MB) and malachite green (MG). The photocatalytic studies reveal that the ZnO/g-C{sub 3}N{sub 4} composite film having smallest aperture exhibits superior photocatalytic activity compared with other meshes. The degradation efficiency of this composite film for MB and MG dyes are 97% (irradiation time-75 min) and 95% (irradiation time-45 min), whereas for pristine ZnO film the corresponding efficiencies are only 88% and 87%. The aperture size related photocatalytic efficiency variations and the effect of g-C{sub 3}N{sub 4} addition on the photocatalytic efficiency of ZnO films have been addressed with appropriate supporting experimental evidences and reports.

36 MATERIALS SCIENCE↗

Microstructure and mesh sensitivities of mesoscale surrogate driving force measures for transgranular fatigue cracks in polycrystals

The number of cycles required to form and grow microstructurally small fatigue cracks in metals exhibits substantial variability, particularly for low applied strain amplitudes. This variability is commonly attributed to the heterogeneity of cyclic plastic deformation within the microstructure, and presents a challenge to minimum life design of fatigue resistant components. Our paper analyzes sources of variability that contribute to the driving force of transgranular fatigue cracks within nucleant grains. We also employ crystal plasticity finite element simulations that explicitly render the polycrystalline microstructure and Fatigue Indicator Parameters (FIPs) averaged over different volume sizes and shapes relative to the anticipated fatigue damage process zone. Volume averaging is necessary to both achieve description of a finite fatigue damage process zone and to regularize mesh dependence in simulations. Furthermore, results from constant amplitude remote applied straining are characterized in terms of the extreme value distributions of volume averaged FIPs. Grain averaged FIP values effectively mitigate mesh sensitivity, but they smear out variability within grains. Furthermore, volume averaging over bands that encompass critical transgranular slip planes appear to present the most attractive approach to mitigate mesh sensitivity while preserving variability within grains.

36 MATERIALS SCIENCE↗

Subdivision meshes for organizing spatial biomedical data.

Abstract As bio-medical images and volumes are being collected at an increasing speed, there is a growing demand for efficient means to organize spatial information for comparative analysis. In many scenarios, such as determining gene expression patterns by in situ hybridization, the images are collected from multiple subjects over a common anatomical region, such as the brain. A fundamental challenge in comparing spatial data from different images is how to account for the shape variations among subjects, which makes direct image-to-image comparison meaningless. In this paper, we describe subdivision meshes as a geometric means to efficiently organize 2D images and 3D volumes collected from different subjects for comparison. The key advantages of a subdivision mesh for this purpose are its light-weight geometric structure and its explicit modeling of anatomical boundaries, which enable efficient and accurate registration. The multi-resolution structure of a subdivision mesh also allows development of fast comparison algorithms among registered images and volumes.

59 BASIC BIOLOGICAL SCIENCES↗

Adaptive mesh refinement versus subgrid friction interpolation in simulations of Antarctic ice dynamics

At least in conventional hydrostatic ice-sheet models, the numerical error associated with grounding line dynamics can be reduced by modifications to the discretization scheme. These involve altering the integration formulae for the basal traction and/or driving stress close to the grounding line and exhibit lower – if still first-order – error in the MISMIP3d experiments. MISMIP3d may not represent the variety of real ice streams, in that it lacks strong lateral stresses, and imposes a large basal traction at the grounding line. We study resolution sensitivity in the context of extreme forcing simulations of the entire Antarctic ice sheet, using the BISICLES adaptive mesh ice-sheet model with two schemes: the original treatment, and a scheme, which modifies the discretization of the basal traction. The second scheme does indeed improve accuracy – by around a factor of two – for a given mesh spacing, but $\lesssim 1$ km resolution is still necessary. For example, in coarser resolution simulations Thwaites Glacier retreats so slowly that other ice streams divert its trunk. In contrast, with $\lesssim 1$ km meshes, the same glacier retreats far more quickly and triggers the final phase of West Antarctic collapse a century before any such diversion can take place.

54 ENVIRONMENTAL SCIENCES↗

Geometric electrostatic particle-in-cell algorithm on unstructured meshes

We present a geometric particle-in-cell (PIC) algorithm on unstructured meshes for studying electrostatic perturbations with frequency lower than electron gyrofrequency in magnetized plasmas. In this method, ions are treated as fully kinetic particles and electrons are described by the adiabatic response. The PIC method is derived from a discrete variational principle on unstructured meshes. To preserve the geometric structure of the system, the discrete variational principle requires that the electric field is interpolated using Whitney 1-forms, the charge is deposited using Whitney 0-forms and the electric field is computed by discrete exterior calculus. The algorithm has been applied to study the ion Bernstein wave (IBW) in two-dimensional magnetized plasmas. The simulated dispersion relations of the IBW in a rectangular region agree well with theoretical results. In a two-dimensional circular region with fixed boundary condition, the spectrum and eigenmode structures of the IBW are obtained from simulations. We compare the energy conservation property of the geometric PIC algorithm derived from the discrete variational principle with that of previous PIC methods on unstructured meshes. The comparison shows that the new PIC algorithm significantly improves the energy conservation property.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mesh-shape-and-size controlled rapid-melting growth for the formation of single-crystalline (100), (110), and (111) Ge networks on insulators

Single-crystalline-Ge (c-Ge) networks with various crystal orientations on insulators formed on Si substrates are essential for integrating high-speed and multifunctional devices onto the Si platform. c-Ge networks are realized by rapid-melting growth of mesh-patterned amorphous-Ge over large areas (500x250 {mu}m{sup 2}) on (110) and (111) as well as (100) Si substrates by optimizing the shape and the size of the mesh. It is revealed that latent-heat generated at the growth front can be controlled by selecting mesh-shape-and-size, which suppresses the spontaneous nucleation. In addition, essential role of the growth-direction on preventing the rotational growth is clarified.

36 MATERIALS SCIENCE↗

Development of Au-Ag nanowire mesh fabrication by UV-induced approach

In an attempt to overcome the limitations of the presently prevailing transparent conducting electrode (TCE) - indium tin oxide (ITO) - many materials have been considered for replacing ITO. Recently, a novel method has been reported for the synthesis of Au-Ag nanowire (NW) mesh, and tested successfully for organic-light-emitting-diodes (OLEDs). It employs UV-induced reduction of gold- and silver- precursors to form Au-Ag NW mesh. In this report, Au-Ag NW mesh thin films are synthesized on glass substrates with an objective for use as facing-electrode for Organic Photovoltaics. Various issues and factors affecting the fabrication-process have been improved, and are also discussed here. The electrode showed good transmitivity, of around 95% (excluding that of glass substrate). The advantage of the technique is its simple processing method and cost-effectiveness.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of plasma equilibrium in toroidal fusion devices using mesh-free numerical calculation method

Plasma confinement using external magnetic field is one of the successful ways leading to the controlled nuclear fusion. Development and validation of the solution process for plasma equilibrium in the experimental toroidal fusion devices is the main subject of this work. Solution of the nonlinear 2D stationary problem as posed by the Grad-Shafranov equation gives quantitative information about plasma equilibrium inside the vacuum chamber of hot fusion devices. This study suggests solving plasma equilibrium equation which is essential in toroidal nuclear fusion devices, using a mesh-free method in a condition that the plasma boundary is unknown. The Grad-Shafranov equation has been solved numerically by the point interpolation collocation mesh-free method. Important features of this approach include truly mesh free, simple mathematical relationships between points and acceptable precision in comparison with the parametric results. The calculation process has been done by using the regular and irregular nodal distribution and support domains with different points. The relative error between numerical and analytical solution is discussed for several test examples such as small size Damavand tokamak, ITER-like equilibrium, NSTX-like equilibrium, and typical Spheromak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Memristive devices from ZnO nanowire bundles and meshes

Here, we report two types of memristive devices made of ZnO nanowire assemblies and Ag electrodes: nanowire-bundle and nanowire-mesh memristors. Although constructed with the same materials, these devices exhibit different characteristics. Nanowire-bundle memristors have small On/Off ratios and feature stable hysteresis under X-ray irradiation. Nanowire-mesh memristors show large On/Off ratios and multiple distinct states. We attribute the switching in bundle nanowires to the modification of the Schottky barrier by the mobile Ag ions and the stability of hysteresis to the ability of the bundles to retain Ag in the alleys between nanowires, as confirmed by first-principles calculations and energy dispersive x-ray measurements. For nanowire-mesh memristors, the high On/Off ratio leads us to attribute the switching mechanism to the formation and dissolution of Ag bridges in the nano-gaps at the intersections of nanowires.

42 ENGINEERING↗

Simulation study of the effects of polymer network dynamics and mesh confinement on the diffusion and structural relaxation of penetrants

The diffusion of small molecular penetrants through polymeric materials represents an important fundamental problem, relevant to the design of materials for applications such as coatings and membranes. Polymer networks hold promise in these applications because dramatic differences in molecular diffusion can result from subtle changes in the network structure. In this paper, we use molecular simulation to understand the role that cross-linked network polymers have in governing the molecular motion of penetrants. By considering the local, activated alpha relaxation time of the penetrant and its long-time diffusive dynamics, we can determine the relative importance of activated glassy dynamics on penetrants at the segmental scale vs entropic mesh confinement on penetrant diffusion. We vary several parameters, such as the cross-linking density, temperature, and penetrant size, to show that cross-links primarily affect molecular diffusion through the modification of the matrix glass transition, with local penetrant hopping at least partially coupled to the segmental relaxation of the polymer network. This coupling is very sensitive to the local activated segmental dynamics of the surrounding matrix, and we also show that penetrant transport is affected by dynamic heterogeneity at low temperatures. To contrast, only at high temperatures and for large penetrants or when the dynamic heterogeneity effect is weak, does the effect of mesh confinement become significant, even though penetrant diffusion more broadly empirically follows similar trends as established models of mesh confinement-based transport.

Chemistry↗

Mesh and model requirements for capturing deep-stall aerodynamics in low-Mach-number flows

Here, this work presents a comprehensive computational fluid dynamics investigation of the effects of grid resolution and turbulence-model choice for capturing the unsteady three-dimensional aerodynamic performance of NACA 0012 and 0021 airfoils, with specific focus on the deep-stall regime. At high angles of attack (α), wind turbine blades routinely experience vortex-induced vibrations, which can cause significant structural damages. Accurate predictions of post-stall aerodynamics can identify the frequencies at which such vibrations maybe triggered. In this context, the NACA 0012 airfoil simulations are conducted at a chord-based Reynolds number, Re c =2×10 6 , with the k-ω Shear-Stress Transport Reynolds-Averaged Navier-Stokes (RANS) and Improved Delayed Detached Eddy Simulation (IDDES) hybrid RANS-Large Eddy Simulation turbulence models. The effect of mesh resolution both in the wall-normal and spanwise directions is investigated. Only the IDDES model with a minimum spanwise resolution of 24 cells per chord length correctly predicts the aerodynamic forces. Spectral analysis shows the peak primary shedding frequency at α=30°, which signifies the end of the stall region. In the post-stall regime, both lift and drag frequencies drop asymptotically with increasing α. The Strouhal number, based on normalised chord length, remains nearly constant in this region. Based on this study, NACA 0021 airfoil runs are performed with IDDES for Re c =2.7×10 5 and 2.0×10 6 on the finest wall-normal mesh and three spanwise grids. Simulations conducted on the finer spanwise grids demonstrate grid independence and show good agreement with experiments. The effect of varying Rec on the airfoil frequency statistics is investigated. Additionally, comparison studies are presented to investigate the impact of airfoil thickness on the frequency content at Re c =2.0×10 6 . The results from the study provide guidance on the choice of mesh resolution with the IDDES model to accurately capture aerodynamic quantities for complex industrial applications.

17 WIND ENERGY↗

CCD Photometry of bright stars using objective wire mesh

Obtaining accurate photometry of bright stars from the ground remains problematic due to the danger of overexposing the target and/or the lack of suitable nearby comparison stars. The century-old method of using objective wire mesh to produce multiple stellar images seems promising for the precise CCD photometry of such stars. Furthermore, our tests on β Cep and its comparison star, differing by 5 mag, are very encouraging. Using a CCD camera and a 20 cm telescope with the objective covered by a plastic wire mesh, in poor weather conditions, we obtained differential photometry with a precision of 4.5 mmag per two minute exposure. Our technique is flexible and may be tuned to cover a range as big as 6-8 mag. We discuss the possibility of installing a wire mesh directly in the filter wheel.

79 ASTRONOMY AND ASTROPHYSICS↗

GRChombo : Numerical relativity with adaptive mesh refinement

In this work, we introduce GRChombo: a new numerical relativity code which incorporates full adaptive mesh refinement (AMR) using block structured Berger-Rigoutsos grid generation. The code supports non-trivial 'many-boxes-in-many-boxes' mesh hierarchies and massive parallelism through the message passing interface. GRChombo evolves the Einstein equation using the standard BSSN formalism, with an option to turn on CCZ4 constraint damping if required. The AMR capability permits the study of a range of new physics which has previously been computationally infeasible in a full 3 + 1 setting, while also significantly simplifying the process of setting up the mesh for these problems. We show that GRChombo can stably and accurately evolve standard spacetimes such as binary black hole mergers and scalar collapses into black holes, demonstrate the performance characteristics of our code, and discuss various physics problems which stand to benefit from the AMR technique.

Clough, Katy (ORCID:0000000188411522)↗

Proton radiography inversions with source extraction and comparison to mesh methods

In this article, proton radiography is a central diagnostic technique for measuring electromagnetic (EM) fields in high-energy-density, laser-produced plasmas. In this technique, protons traverse the plasma where they accumulate small EM deflections which lead to variations in the proton fluence pattern on a detector. Path-integrated EM fields can then be extracted from the fluence image through an inversion process. In this work, experiments of laser-driven foils were conducted on the OMEGA laser and magnetic field reconstructions were performed using both “fluence-based” techniques and high-fidelity “mesh-based” methods. We implement nonzero boundary conditions into the inversion and show their importance by comparing against mesh measurements. Good agreement between the methods is found only when nonzero boundary conditions are used. We also introduce an approach to determine the unperturbed proton source profile, which is a required input in fluence reconstruction algorithms. In this approach, a fluence inversion is embedded inside of a mesh region, which provides overconstrained magnetic boundary conditions. A source profile is then iteratively optimized to satisfy the boundary information. This method substantially enhances the accuracy in recovering EM fields. Lastly, we propose a scheme to quantify uncertainty in the final inversion that is introduced through errors in the source retrieval.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lagrange-mesh calculations and Fourier transform

The Lagrange-mesh method is a very accurate procedure for computing eigenvalues and eigenfunctions of a two-body quantum equation written in the configuration space. Using a Gauss quadrature rule, the method only requires the evaluation of the potential at some mesh points. The eigenfunctions are expanded in terms of regularized Lagrange functions, which vanish at all mesh points except one. Using the peculiarities of the method, it is shown that the Fourier transform of the eigenfunctions, computed in the configuration space, can easily be obtained with good accuracy in the physical domain of the momentum space. Also, observables in this space can easily be computed with good accuracy only using matrix elements and eigenfunctions computed in the configuration space.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Robust Solution Verification Experiments on Nonuniform Meshes

The activities of verification, validation, and uncertainty quantification (VVUQ) provide a comprehensive means to assess the credibility of computational models. Within VVUQ, solution verification assesses numerical errors and evaluates whether the simulation is sufficiently accurate for its intended applications. As computational modeling gains traction in the development of complex, high-consequence systems, the need for robust solution verification intensifies, particularly because experimental data for these systems are often limited. This work examines improvements in the robustness of Richardson extrapolation (RE), a method commonly used in solution verification to study the discretization error of computational models using a power law. Nonuniform mesh refinement is discussed alongside other pollutants that affect the robustness of the power law model. Maximum likelihood estimation (MLE) is proposed as a robust strategy to address the uncertainty generated by nonuniform mesh refinement. An exploratory computational fluid dynamics (CFD) study of a 2D planar Poiseuille flow is conducted to determine if nonuniform mesh noise can be modeled with this MLE approach for more robust RE.

Weinmeister, Justin [ORNL] (ORCID:0000000160090237↗

Enhanced retained dose uniformity in NiTi spinal correction rod treated by three-dimensional mesh-assisted nitrogen plasma immersion ion implantation

Owing to the nonconformal plasma sheath in plasma immersion ion implantation of a rod sample, the retained dose can vary significantly. The authors propose to improve the implant uniformity by introducing a metal mesh. The depth profiles obtained with and without the mesh are compared and the implantation temperature at various locations is evaluated indirectly by differential scanning calorimeter. Our results reveal that by using the metal mesh, the retained dose uniformity along the length is greatly improved and the effects of the implantation temperature on the localized mechanical properties of the implanted NiTi shape memory alloy rod are nearly negligible.

36 MATERIALS SCIENCE↗

A 3D global-to-local deformable mesh model based registration and anatomy-constrained segmentation method for image guided prostate radiotherapy

Purpose: In the external beam radiation treatment of prostate cancers, successful implementation of adaptive radiotherapy and conformal radiation dose delivery is highly dependent on precise and expeditious segmentation and registration of the prostate volume between the simulation and the treatment images. The purpose of this study is to develop a novel, fast, and accurate segmentation and registration method to increase the computational efficiency to meet the restricted clinical treatment time requirement in image guided radiotherapy. Methods: The method developed in this study used soft tissues to capture the transformation between the 3D planning CT (pCT) images and 3D cone-beam CT (CBCT) treatment images. The method incorporated a global-to-local deformable mesh model based registration framework as well as an automatic anatomy-constrained robust active shape model (ACRASM) based segmentation algorithm in the 3D CBCT images. The global registration was based on the mutual information method, and the local registration was to minimize the Euclidian distance of the corresponding nodal points from the global transformation of deformable mesh models, which implicitly used the information of the segmented target volume. The method was applied on six data sets of prostate cancer patients. Target volumes delineated by the same radiation oncologist on the pCT and CBCT were chosen as the benchmarks and were compared to the segmented and registered results. The distance-based and the volume-based estimators were used to quantitatively evaluate the results of segmentation and registration. Results: The ACRASM segmentation algorithm was compared to the original active shape model (ASM) algorithm by evaluating the values of the distance-based estimators. With respect to the corresponding benchmarks, the mean distance ranged from -0.85 to 0.84 mm for ACRASM and from -1.44 to 1.17 mm for ASM. The mean absolute distance ranged from 1.77 to 3.07 mm for ACRASM and from 2.45 to 6.54 mm for ASM. The volume overlap ratio ranged from 79% to 91% for ACRASM and from 44% to 80% for ASM. These data demonstrated that the segmentation results of ACRASM were in better agreement with the corresponding benchmarks than those of ASM. The developed registration algorithm was quantitatively evaluated by comparing the registered target volumes from the pCT to the benchmarks on the CBCT. The mean distance and the root mean square error ranged from 0.38 to 2.2 mm and from 0.45 to 2.36 mm, respectively, between the CBCT images and the registered pCT. The mean overlap ratio of the prostate volumes ranged from 85.2% to 95% after registration. The average time of the ACRASM-based segmentation was under 1 min. The average time of the global transformation was from 2 to 4 min on two 3D volumes and the average time of the local transformation was from 20 to 34 s on two deformable superquadrics mesh models. Conclusions: A novel and fast segmentation and deformable registration method was developed to capture the transformation between the planning and treatment images for external beam radiotherapy of prostate cancers. This method increases the computational efficiency and may provide foundation to achieve real time adaptive radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗