Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Machine Learning for LBNF Beam Diagnostics

This paper focuses on developing a machine learning model for predicting initial beam parameters for the Long Baseline Neutrino Facility (LBNF) beamline using downstream muon monitor data. Parameters such as proton beam position on target, sigma on target, focusing horn current, and focusing horn tilt are parameters we anticipate to be predictable based on the muon monitors. Uncertainty in initial beam condition measurements are a major contributor to uncertainty in downstream flux, and over operation time beam misalignment can occur [1]. A machine learning model has promise to detect anomalies along the beamline based on discrepancies between predicted configurations and measured configurations, and thus can expedite error detection and handling. A PyTorch neural network is defined, trained, and tested. The developed model currently does not provide reliable predictions, with the lowest loss being 0.09.. Further steps to improve the model’s accuracy are discussed, as well as future plans to detect anomalous beam conditions using a digital twin.

O'Brien, Bridget [Fermilab]↗

Body surface area equations for physically active men and women

Abstract Objectives To improve predictive formulae for estimating body surface area (BSA) in healthy men and women using a modern three‐dimensional scanner technology. Methods Body surface areas were obtained from a convenience sample of 1267 US Marines (464 women and 803 men) using a whole body surface scanner (Size Stream SS20). The reliability of SS20 measures of total and regional BSA within participants was compared across triplicate scans. We then derived a series of formulae to estimate SS20‐measured BSA using various combinations of sex, height, and mass. We also assessed relationships between percent body fat measured by dual‐energy x‐ray absorptiometry and sex‐specific formulae errors in Marines. Results Body surface areas recorded by the SS20 were highly reliable whether measured for the total body or by region (ICC ≥ .962). Formulae estimates of BSA from sex, height, and mass were precise (root‐mean‐square deviation, 0.031 m 2 ). Errors from the Marine Corps formulae were positively associated with percent body fat for men ( p = .001) but not women ( p = .843). Conclusions Clinicians, military leaders, and researchers can use the newly developed BSA formulae for precise estimates in healthy physically active men and women. Users should be aware that height‐ and mass‐based BSA estimates are less accurate for individuals with extremely low or high percent body fat.

Looney, David P.↗

Constrained variational optimization of counting-time allocation in sequential scattering measurements: Application to Bonse–Hart USANS

Sequential scattering measurements are often performed under a fixed experimental-time budget, even though the expected count rate varies strongly across the measured coordinate. When the dwell time at each measurement position can be controlled independently, this variation creates a general resource-allocation problem: how should the available time be distributed to minimize the uncertainty of the reconstructed profile? We formulate this problem as a constrained variational optimization for measurements governed by Poisson counting statistics. When each measurement is treated independently, minimizing the averaged squared relative uncertainty yields an inverse-square-root intensity allocation. The formulation is then generalized to include correlations between neighboring measurements and an instrumental resolution operator, leading to an allocation criterion that equalizes the marginal reduction in posterior uncertainty per unit measurement time. Bonse–Hart ultra-small-angle neutron scattering (USANS), in which reciprocal space is sampled sequentially through analyzer-angle stepping, provides an experimentally grounded application. Computational benchmarking shows that the optimized allocation outperforms uniform-time and constant-relative-error strategies, while application to an experimentally measured graphite USANS profile from the Spallation Neutron Source, using Poisson resampling under alternative schedules, demonstrates how counting time should be redistributed toward weak-intensity regions under an identical total duration. The resulting framework applies to sequential scattering and related scanning measurements whenever local dwell times are adjustable and directly determine the measurement uncertainties, and when the relevant correlation and instrumental-response models are available.

Tung, Chi-Huan [ORNL] (ORCID:0000000221972074)↗

The impact of detection rate changes and correlations on random-coincidence background measurements

Coincidence detection of multiple particles emitted during an experiment can yield a new depth of understanding of the underlying process under study. However, the probability of detecting particles that are generated from the same physical event within a given coincidence time window is generally much lower than that of detecting particles that appear in the same coincidence time window, but were not created from the same physical event, and are therefore detected randomly in coincidence with each other. Thus, accurate and precise methods of measuring this random-coincidence background are essential for a wide variety of fields of science. A method to determine this background directly using the data themselves without any additional experimental run time or fake signals introduced in the data was recently established (O’Donnell, 2016). This method yields a statistical uncertainty on the random-coincidence background that is orders of magnitude smaller than that of the true coincidence data, though the potential for systematic errors of backgrounds from this method was never explored. In this work, we discuss common varieties of correlated and uncorrelated changes in the detection rates of each particle detected in an experiment. Here we demonstrate here that a correlation between particle detection rates from, for example, an incident particle beam that initiates a physical process of interest, creates systematic errors in the random-coincidence background measurement. We also discuss the impact of a variety of other realistic scenarios for rate changes in experiments. Lastly, a method is introduced to correct for errors in the random-coincidence background from any source, yielding an optimization between statistical precision and eliminating potential lingering systematic errors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchronous detection of cosmic rays and correlated errors in superconducting qubit arrays

Quantum information processing at scale will require sufficiently stable and long-lived qubits, likely enabled by error-correction codes. Several recent superconducting-qubit experiments, however, reported observing intermittent spatiotemporally correlated errors that would be problematic for conventional codes, with ionizing radiation being a likely cause. Here, we directly measured the cosmic-ray contribution to spatiotemporally correlated qubit errors. We accomplished this by synchronously monitoring cosmic-ray detectors and qubit energy-relaxation dynamics of 10 transmon qubits distributed across a 5 × 5 × 0.35 mm 3 silicon chip. Cosmic rays caused correlated errors at a rate of $1/\left(592\begin{array}{c}+48\\ -41\end{array}\,{\rm{s}}\right)$, accounting for 17.1 ± 1.3% of all such events. Our qubits responded to essentially all of the cosmic rays and their secondary particles incident on the chip, consistent with the independently measured arrival flux. Moreover, we observed that the landscape of the superconducting gap in proximity to the Josephson junctions dramatically impacts the qubit response to cosmic rays. Given the practical difficulties associated with shielding cosmic rays, our results indicate the importance of radiation hardening—for example, superconducting gap engineering—to the realization of robust quantum error correction.

Science & Technology - Other Topics↗

Analysis and improvement of the hot disk transient plane source method for low thermal conductivity materials

The hot disk transient plane source (TPS) method is a widely used standard technique (ISO 22007-2) for the characterization of thermal properties of materials, especially the thermal conductivity, k. Despite its well-established reliability for a wide variety of common materials, the hot disk TPS method is also known to suffer from a substantial systematic errors when applied to low-k thermal insulation materials. Here, we present a combined numerical and experimental study on the influence of the geometry of hot disk sensor on measured value of low-k materials. We demonstrate that the error is strongly affected by the finite thickness and thermal mass of the sensor's insulation layer was well as the corresponding increase of the effective heater size beyond the radius of the embedded metal heater itself. We also numerically investigate the dependence of the error on the sample thermal properties, confirming that the errors are worse in low-k samples. A simple correction function is also provided, which converts the apparent (erroneous) result from a standard hot disk TPS measurement to a more accurate value. A standard polyimide sensor was also optimized using both wet and dry etching to provide more accurate measurement directly. Experimentally corrected value of k for Airloy x56 aerogel and a commercial silica aerogel using the numerical correction factor derived based on the standard TPS sensor is in excellent agreement with the directly measured value from the TPS sensor using the optimized polyimide sensor. Finally, both of these methods can reduce the errors to less than 4% as compared to around 40% error of overestimation from raw values measured with the pristine sensor. Such results show that both the numerical correction to a pristine senor or an optimized sensor are capable of providing highly accurate value of thermal conductivity for such materials.

36 MATERIALS SCIENCE↗

DARHT-II Beam Position Monitor B-Dot Owner’s Manual

Azimuthal arrays of magnetic and electric field detectors are used to measure the position of the centroid of the DARHT relativistic electron beams. These arrays consist of four detectors with 90-degree azimuthal separation. Differencing the opposing detectors and normalizing to the sum of all four gives the position of the beam, subject to negligibly small errors as discussed in Attachment A. This measurement yields the centroid of the current density, independent of the beam azimuthal asymmetry.

42 ENGINEERING↗

Interactive cryptographic proofs of quantumness using mid-circuit measurements

The ability to perform measurements in the middle of a quantum circuit is a powerful resource. It underlies a wide range of applications, from remote state preparation to quantum error correction. Here we apply mid-circuit measurements for a particular task: demonstrating quantum computational advantage. The goal of such a demonstration is for a quantum device to perform a computational task that is infeasible for a classical device with comparable resources. In contrast to existing demonstrations, the distinguishing feature of our approach is that the classical verification process is efficient, both in asymptotic complexity and in practice. Furthermore, the classical hardness of performing the task is based upon well-established cryptographic assumptions. Protocols with these features are known as cryptographic proofs of quantumness. Using a trapped-ion quantum computer, we perform mid-circuit measurements by spatially isolating portions of the ion chain via shuttling. This enables us to implement two interactive cryptographic proofs of quantumness, which when suitably scaled to larger systems, promise the efficient verification of quantum computational advantage. In conclusion, our methods can be applied to a range of interactive quantum protocols.

97 MATHEMATICS AND COMPUTING↗

Measurement of third-order elastic constants using thermal modulation of ultrasonic waves

Third-order elastic constants (TOEC) play an important role in nonlinear material characterization, but measurements of TOEC are laborious with large error margins. This Letter presents the equations of wave velocity changes caused by homogeneous temperature variation and uniaxial stress in isotropic media and the expression of TOEC in terms of thermally induced velocity change and thermal strain. TOEC of an aluminum sample were experimentally determined by measuring ultrasonic wave velocity changes in the uniaxial loading test and the thermal modulation test. Experimental results showed good agreement between the two test methods. Owing to the simple test setup and high measurement sensitivity, the thermal modulation test is a potential experimental method to determine TOEC and absolute acoustic nonlinearity parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Resilient State Recovery Using Prior Measurement Support Information

Resilient state recovery of cyber-physical systems has attracted much research attention due to the unique challenges posed by the tight coupling between communication, computation, and the underlying physics of such systems. By modeling attacks as additive adversary signals to a sparse subset of measurements, this resilient recovery problem can be formulated as an error correction problem. To achieve exact state recovery, most existing results require less than 50% of the measurement nodes to be compromised, which limits the resiliency of the estimators. In this paper, we show that observer resiliency can be further improved by incorporating data-driven prior information. Here, we provide an analytical bridge between the precision of prior information and the resiliency of the estimator. By quantifying the relationship between the estimation error of the weighted ℓ 1 observer and the precision of the support prior, this quantified relationship provides guidance for the estimator’s weight design to achieve optimal resiliency. Several numerical simulations and an application case study are presented to validate the theoretical claims.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Superconducting Material Growth for Radio-Frequency (RF) Cavities

Superconducting radio-frequency (SRF) cavities, usually manufactured from Niobium (Nb), are vital components of modern particle accelerators because of their ability to achieve high acceleration gradients with little power dissipation. Naturally forming Nb surface oxides significantly alter cavity performance by changing surface resistance. A nondestructive characterization of oxide thickness is helpful for relating surface processing treatments to cavity performance. This work develops a protocol to measure Nb oxide thickness using Angle-Resolved X-ray Photoelectron Spectroscopy (ARXPS) while correcting instrumental errors. Using uniform bulk standard samples (Silver, Aluminum oxide, and Germanium), we determined a baseline correction factor to account for analyzer-related intensity evolution as the measurement angle increases. The correction factor was then applied to Nb 3d ARXPS data. Applying the Strohmeier equation to the corrected data yielded a Nb2O5 thickness of 6.04 nm, closely matching the 5.5 (±.05) nm value obtained from cross-sectional transmission electron microscopy. Our approach will bring a method to incorporate inherent errors in the thickness measurements using ARXPS and can be broadly applied to improve the accuracy of thickness measurements in a wide range of heterostructures.

Lambert, Nathan [Fermilab]↗

Superconducting Material Growth for Radio-Frequency (RF) Cavities

Superconducting radio-frequency (SRF) cavities, usually manufactured from Niobium (Nb), are vital components of modern particle accelerators because of their ability to achieve high acceleration gradients with little power dissipation. Naturally forming Nb surface oxides significantly alter cavity performance by changing surface resistance. A nondestructive characterization of oxide thickness is helpful for relating surface processing treatments to cavity performance. This work develops a protocol to measure Nb oxide thickness using Angle-Resolved X-ray Photoelectron Spectroscopy (ARXPS) while correcting instrumental errors. Using uniform bulk standard samples (Silver, Aluminum oxide, and Germanium), we determined a baseline correction factor to account for analyzer-related intensity evolution as the measurement angle increases. The correction factor was then applied to Nb 3d ARXPS data. Applying the Strohmeier equation to the corrected data yielded a Nb2O5 thickness of 6.04 nm, closely matching the 5.5 (±.05) nm value obtained from cross-sectional transmission electron microscopy. Our approach will bring a method to incorporate inherent errors in the thickness measurements using ARXPS and can be broadly applied to improve the accuracy of thickness measurements in a wide range of heterostructures.

Lambert, Nathan [Fermilab]↗

Certified quantum measurement of Majorana fermions

Here, we propose a quantum self-testing protocol to certify measurements of fermion parity involving Majorana fermion modes. We further show that observing a set of ideal measurement statistics implies anticommutativity of the implemented Majorana fermion parity operators, a necessary prerequisite for Majorana detection. Our protocol is robust to experimental errors. We obtain lower bounds on the fidelities of the state and measurement operators that are linear in the errors. We propose to analyze experimental outcomes in terms of a contextuality witness W , which satisfies 〈 W 〉 ≤ 3 for any classical probabilistic model of the data. A violation of the inequality witnesses quantum contextuality, and the closeness to the maximum ideal value 〈 W 〉 = 5 indicates the degree of confidence in the detection of Majorana fermions.

36 MATERIALS SCIENCE↗

Standardizing reverberation-measured C iv time-lag quasars, and using them with standardized Mg ii quasars to constrain cosmological parameters

ABSTRACT We use 38 C iv quasar (QSO) reverberation-mapped observations, which span eight orders of magnitude in luminosity and the redshift range 0.001064 ≤ z ≤ 3.368, to simultaneously constrain cosmological-model and QSO radius–luminosity (R–L) relation parameters in six cosmological models, using an improved technique that more correctly accounts for the asymmetric errors bars of the time-lag measurements. We find that R–L relation parameters are independent of the cosmological models used in the analysis and so the R–L relation can be used to standardize the C iv QSOs. The C iv QSO cosmological constraints are consistent with those from Mg ii QSOs, allowing us to derive joint C iv + Mg ii QSO cosmological constraints which are consistent with currently accelerated cosmological expansion, as well as consistent with cosmological constraints derived using better-established baryon acoustic oscillation (BAO) and Hubble parameter [H(z)] measurements. When jointly analysed with H(z) + BAO data, current C iv + Mg ii QSO data mildly tighten current H(z) + BAO data cosmological constraints.

79 ASTRONOMY AND ASTROPHYSICS↗

Advanced flip-coil system for magnetic field integral measurements of insertion devices

A novel flip-coil measurement system has been developed for the National Synchrotron Light Source II (NSLS-II) at Brookhaven National Laboratory. This paper describes the design, implementation, and commissioning of the new measurement bench, highlighting its key features, including improved mechanical stability, advanced data acquisition, and enhanced reproducibility. The system enables precise characterization of field integrals and multipole components, ensuring the optimal performance of Insertion Devices (IDs) before installation in the NSLS-II storage ring. The flip-coil system incorporates an innovative approach to minimize mechanical and electrical errors, which significantly improves the reproducibility of measurements. In addition, the system features a state-of-the-art data acquisition system that enables real-time monitoring and analysis, further enhancing the efficiency and accuracy of the measurement process. Furthermore, preliminary tests have demonstrated that the new system meets the stringent requirements for magnetic field characterization of advanced insertion devices, making it an essential tool for future ID commissioning and quality assurance at NSLS-II.

36 MATERIALS SCIENCE↗

Demonstration of the rodeo algorithm on a quantum computer

The rodeo algorithm is an efficient algorithm for eigenstate preparation and eigenvalue estimation for any observable on a quantum computer. This makes it a promising tool for studying the spectrum and structure of atomic nuclei as well as other fields of quantum many-body physics. The only requirement is that the initial state has sufficient overlap probability with the desired eigenstate. While it is exponentially faster than well-known algorithms such as phase estimation and adiabatic evolution for eigenstate preparation, it has yet to be implemented on an actual quantum device. In this work, we apply the rodeo algorithm to determine the energy levels of a random one-qubit Hamiltonian, resulting in a relative error of 0.08% using mid-circuit measurements on the IBM Q device Casablanca. This surpasses the accuracy of directly-prepared eigenvector expectation values using the same quantum device. We take advantage of the high-accuracy energy determination and use the Hellmann-Feynman theorem to compute eigenvector expectation values for a different random one-qubit observable. For the Hellmann-Feynman calculations, we find a relative error of 0.7%. Here, we conclude by discussing possible future applications of the rodeo algorithm for multi-qubit Hamiltonians.

algorithm↗

Assessment of errors in analytic modeling of permanent magnet electron spectrometers for laser-plasma accelerators

Here, we assess the error in three treatments of a critical electron beam diagnostic for laser-plasma acceleration (LPA) experiments: a permanent magnet electron spectrometer. Since LPA electron spectrometers are often difficult to calibrate due to the scarcity of well-characterized, tunable electron beam sources in the appropriate energy range and the mechanical complexity of electron spectrometers, the standard of calibration is Hall probe measurements. We first compare the electron spectrometer performance between SIMION calculations and the Hall probe measurements. We find up to a 60% (<8%) error in determining the absolute energy for electrons below (above) 80 MeV when using the SIMION-modeled magnetic field vs the measured magnetic field due to SIMION overpredicting fringe field strength. The difference in spectrometer energy resolution is within ∼10% between the modeled and measured fields. We then assess a simple block model, which is commonly used. We find that the simple block model presented here sufficiently captures the predicted as-built spectrometer performance for any application provided that the user can tolerate uncertainties on absolute energy determination up to 5% and errors on energy resolution up to 1%.

Electromagnetic optics↗

Correcting thermal-emission-induced detector saturation in infrared spectroscopy

We found that temperature-dependent infrared spectroscopy measurements (i.e., reflectance or transmittance) using a Fourier-transform spectrometer can have substantial errors, especially for elevated sample temperatures and collection using an objective lens. These errors can arise as a result of partial detector saturation due to thermal emission from the measured sample reaching the detector, resulting in nonphysical apparent reduction of reflectance or transmittance with increasing sample temperature. Here, we demonstrate that these temperature-dependent errors can be corrected by implementing several levels of optical attenuation that enable convergence testing of the measured reflectance or transmittance as the thermal-emission signal is reduced, or by applying correction factors that can be inferred by looking at the spectral regions where the sample is not expected to have a substantial temperature dependence.

47 OTHER INSTRUMENTATION↗