Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measured data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Static jet noise test results of four 0.35 scale-model QCGAT mixer nozzles

As part of the NASA Quiet Clean General Aviation Turbofan (QCGAT) engine mixer-nozzle exhaust system program, static jet exhaust noise was recorded at microphone angles of 45 to 155 deg relative to the nozzle inlet for a conventional profile coaxial nozzle and three 12-lobed coaxial mixer nozzles. Both flows in all four nozzles are internally mixed before being discharged from a single exhaust nozzle. The conventional profile coaxial nozzle jet noise is compared to the current NASA Lewis coaxial jet noise prediction and after applying an adjustment to the predicted levels based on the ratio of the kinetic energy of the primary and secondary flows, the prediction is within a standard deviation of 0.9 dB of the measured data. The mass average (mixed flow) prediction is also compared to the noise data for the three mixer nozzles with a reasonably good fit after applying another kinetic energy ratio adjustment (standard deviation of 0.7 to 1.5 dB with the measured data). The tests included conditions for the full-scale engine at takeoff (T.O.), cutback (86% T.O.) and approach (67% T.O.).

Groesbeck, D. E.↗

Monte Carlo calculations of correction factors for plastic phantoms in clinical photon and electron beam dosimetry

The purpose of this study is to calculate correction factors for plastic water (PW) and plastic water diagnostic-therapy (PWDT) phantoms in clinical photon and electron beam dosimetry using the EGSnrc Monte Carlo code system. A water-to-plastic ionization conversion factor k{sub pl} for PW and PWDT was computed for several commonly used Farmer-type ionization chambers with different wall materials in the range of 4-18 MV photon beams. For electron beams, a depth-scaling factor c{sub pl} and a chamber-dependent fluence correction factor h{sub pl} for both phantoms were also calculated in combination with NACP-02 and Roos plane-parallel ionization chambers in the range of 4-18 MeV. The h{sub pl} values for the plane-parallel chambers were evaluated from the electron fluence correction factor {phi}{sub pl}{sup w} and wall correction factors P{sub wall,w} and P{sub wall,pl} for a combination of water or plastic materials. The calculated k{sub pl} and h{sub pl} values were verified by comparison with the measured values. A set of k{sub pl} values computed for the Farmer-type chambers was equal to unity within 0.5% for PW and PWDT in photon beams. The k{sub pl} values also agreed within their combined uncertainty with the measured data. For electron beams, the c{sub pl} values computed for PW and PWDT were from 0.998 to 1.000 and from 0.992 to 0.997, respectively, in the range of 4-18 MeV. The {phi}{sub pl}{sup w} values for PW and PWDT were from 0.998 to 1.001 and from 1.004 to 1.001, respectively, at a reference depth in the range of 4-18 MeV. The difference in P{sub wall} between water and plastic materials for the plane-parallel chambers was 0.8% at a maximum. Finally, h{sub pl} values evaluated for plastic materials were equal to unity within 0.6% for NACP-02 and Roos chambers. The h{sub pl} values also agreed within their combined uncertainty with the measured data. The absorbed dose to water from ionization chamber measurements in PW and PWDT plastic materials corresponds to that in water within 1%. Both phantoms can thus be used as a substitute for water for photon and electron dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Correlation approach for quality assurance of additive manufactured parts based on optical metrology

Surface topography and surface finish are two significant factors for evaluating the quality of products in additive manufacturing (AM). AM parts are fabricated layer by layer, which is quite different from traditional formative or subtractive methods. Despite rapid progress in additive manufacturing and associated optical metrology for quality control and in-situ monitoring, limited research has been conducted to investigate the reliability of 3D surface measurement data. The surface topologies scanned by multiple optical systems demonstrated significant differences due to varying sampling mechanisms, resolutions, system noises, etc. The 3D datasets should be trustworthy in order to extract parameters for quality assurance or feedback control from 3D surface measurements. In this paper, we set up new standards to evaluate the reliability of 3D surface measurement data and analyze the variation in the topographical profile. In this study, two non-contact optical methods based on Focus Variation Microscopy (FVM) and Structured Light System (SLS) were adopted to measure the surface topography of the target components. The two optical metrology systems generated two entirely different point cloud datasets. Statistical methods were applied to test the difference between the data obtained from the two systems. By using a data analytics approach for comparison, it was found that the surface roughness estimated from the point cloud data sets of FVM and SLS has no significant difference, though the point cloud data sets were completely different. This paper provides standard validation approach to evaluate the plausibility of metrology data from in-situ real-time surface analysis for process planning of AM.

36 MATERIALS SCIENCE↗

Astronaut candidate strength measurement using the Cybex 2 and the LIDO Multi-Joint 2 dynamometers

The Anthropometry and Biomechanics Laboratory in the man-Systems division at NASA's Johnson Space Center has as one of its responsibilities the anthropometry and strength measurement data collection of astronaut candidates. The anthropometry data is used to ensure that the astronaut candidates are within the height restrictions for space vehicle and space suit design requirements, for example. The strength data is used to help detect abnormalities or isolate injuries to muscle groups that could jeopardize the astronauts safety. The Cybex II Dynamometer has been used for strength measurements from 1985 through 1991. The Cybex II was one of the first instruments of its kind to measure strength and similarity of muscle groups by isolating the specific joint of interest. In November 1991, a LIDO Multi-Joint II Dynamometer was purchased to upgrade the strength measurement data collection capability of the Anthropometry and Biomechanics Laboratory. The LIDO Multi-Joint II Dynamometer design offers several advantages over the Cybex II Dynamometer including a more sophisticated method of joint isolation and a more accurate and efficient computer based data collection system.

Carroll, Amy E.↗

Adaptive computations of flow around a delta wing with vortex breakdown

An adaptive unstructured mesh solution method for the three-dimensional Euler equations was used to simulate the flow around a sharp edged delta wing. Emphasis was on the breakdown of the leading edge vortex at high angle of attack. Large values of entropy, which indicate vortical regions of the flow, specified the region in which adaptation was performed. The aerodynamic normal force coefficients show excellent agreement with wind tunnel data measured by Jarrah, and demonstrate the importance of adaptation in obtaining an accurate solution. The pitching moment coefficient and the location of vortex breakdown are compared with experimental data measured by Hummel and Srinivasan, showing good agreement in cases in which vortex breakdown is located over the wing.

Modiano, David L.↗

Computational Methods for Analyzing Fluid Flow Dynamics from Digital Imagery

The main goal (long term) of this work is to perform computational dynamics analysis and quantify uncertainty from vector fields computed directly from measured data. Global analysis based on observed spatiotemporal evolution is performed by objective function based on expected physics and informed scientific priors, variational optimization to compute vector fields from measured data, and transport analysis proceeding with observations and priors. A mathematical formulation for computing flow fields is set up for computing the minimizer for the problem. An application to oceanic flow based on sea surface temperature is presented.

42 ENGINEERING↗

An Algorithm for Hyperspectral Remote Sensing of Aerosols: 3. Application to the GEO-TASO Data in KORUS-AQ Field Campaign

This paper describes the third part of a series of investigations to develop algorithms for simultaneous retrieval of aerosol parameters and surface spectral reflectance from the data measured by GEOstationary Trace gas and Aerosol Sensor Optimization (GEO-TASO) instrument. Since the algorithm is designed for future hyperspectral and geostationary satellite sensors, such as Tropospheric Emissions: Monitoring of Pollution (TEMPO), it is applied to GEO-TASO data measured over the same area by different flights as part of the Korea-United Stated Air Quality Study (KORUS-AQ) field campaign in 2016. While GEO-TAOS has a spectral sampling interval of ~0.28 nm in the visible, its data is thinned through a band selection approach with consideration of atmospheric transmittance and different surface types, which yields 20 common spectral bands to be used by the algorithm. The algorithm starts with 4 common principal components (PCs) for surface spectral reflectance extracted from various spectral libraries, and the constraints of surface reflectance parameters and aerosol scattering models respectively from k- means clustering analysis of the Rayleigh-corrected GEO-TASO spectra and AERONET data. The algorithm then proceeds iteratively with an optimal estimation approach to update PCs and retrieve aerosol optical depth (AOD) until the best match between simulated and GEOS-TASO measured spectra is achieved. The spectral AODs are compared between those retrieved from GEO-TASO (x) and 7 AERONETS (y) in 440, 550, 550, 675 nm, respectively. The comparison reveals that iterative updates of surface spectral PCs (and so surface reflectance) yield significant enhancement in AOD retrievals, improving the mean linear fitting equations from y = 0.735x + 0.088 (without update of PCs) to y = 1.055x+ 0.01, and the Pearson correlation coefficient (𝑅𝑅2) from 0.54 to 0.76, respectively. Move case studies are need to further evaluate the algorithm for its application to TEMPO that carries a enhanced version of GEO-TASO instrument.

Tropospheric Emissions: Monitoring of Pollution (T↗

Unraveling hadron transverse momentum in SIDIS: Dynamics, present data, future measurements

The transverse momentum of hadrons observed in the current fragmentation region of SIDIS is generally compounded of several parts: the intrinsic transverse momentum of partons in the target, the effects of QCD radiation, and the broadening due to the fragmentation process. Unraveling the different contributions is a major challenge that needs to be addressed before one can reliably apply QCD factorization formulas and extract information about TMD distributions. Recent pion/kaon multiplicity data from HERMES and COMPASS indicate that non-perturbative dynamics plays an essential role in the measured $P_T$ distributions, particularly at z >~ 0.5. In this talk I briefly summarize (a) what our present knowledge of non-perturbative dynamics suggests regarding the magnitude of the different contributions to hadron transverse momentum; (b) what SIDIS measurements could/should be done to unravel the different contributions; (c) what could be learned from measurements of particle correlations between the current and target fragmentation regions. The talk will be a concise summary and aim to provide input to the discussions. It relates mainly to the topics of Sessions 1 and 2 of the program.

Weiss, Christian↗

Turbulent Navier-Stokes Flow Analysis of an Advanced Semispan Diamond-Wing Model in Tunnel and Free Air at High-Lift Conditions

Turbulent Navier-Stokes computational results are presented for an advanced diamond wing semispan model at low-speed, high-lift conditions. The numerical results are obtained in support of a wind-tunnel test that was conducted in the National Transonic Facility at the NASA Langley Research Center. The model incorporated a generic fuselage and was mounted on the tunnel sidewall using a constant-width non-metric standoff. The computations were performed at to a nominal approach and landing flow conditions.The computed high-lift flow characteristics for the model in both the tunnel and in free-air environment are presented. The computed wing pressure distributions agreed well with the measured data and they both indicated a small effect due to the tunnel wall interference effects. However, the wall interference effects were found to be relatively more pronounced in the measured and the computed lift, drag and pitching moment. Although the magnitudes of the computed forces and moment were slightly off compared to the measured data, the increments due the wall interference effects were predicted reasonably well. The numerical results are also presented on the combined effects of the tunnel sidewall boundary layer and the standoff geometry on the fuselage forebody pressure distributions and the resulting impact on the configuration longitudinal aerodynamic characteristics.

Ghaffari, Farhad↗

NASA/ONERA Collaboration on Small Hovering Rotor Broadband Noise Prediction using Lattice-Boltzmann and Structured Navier-Stokes Solvers

This work compares two lattice-Boltzmann method solvers, PowerFLOW and ProLB, and two structured Navier-Stokes solvers, OVERFLOW2 and FAST, used by NASA and ONERA, respectively, for the broadband noise prediction of an ideally twisted rotor as part of Implementing Arrangement number FR-0685-0, ‘Comparing Computational Fluid Dynamics Solvers for Broadband Noise Prediction.’ Predicted results are evaluated against measured data from both smooth and rough blade sets acquired in the Small Hover Anechoic Chamber at the NASA Langley Research Center. Aerodynamic thrust predictions are seen to agree more favorably with the rough-blade measurements, whereas torque predictions agree better with the smooth-blade measurements. A tonal noise comparison shows better agreement to the measured data with the two structured Navier-Stokes solvers than with the two lattice-Boltzmann solvers, which is thought to be caused by the different geometric discretization associated with each solver paradigm. Broadband noise comparisons show that both lattice-Boltzmann method solvers trend well with the smooth-blade measurements, with the exception of an overprediction by ProLB between 4 kHz and 15 kHz. OVERFLOW2 is seen to capture the measured nondeterministic tonal content between 3 kHz and 8 kHz on a narrowband spectral basis and FAST agrees well with the rough blades on a one-third octave band basis.

Christopher S. Thurman↗

Spherical roller bearing analysis. SKF computer program SPHERBEAN. Volume 3: Program correlation with full scale hardware tests

The results of a series of full scale hardware tests comparing predictions of the SPHERBEAN computer program with measured data are presented. The SPHERBEAN program predicts the thermomechanical performance characteristics of high speed lubricated double row spherical roller bearings. The degree of correlation between performance predicted by SPHERBEAN and measured data is demonstrated. Experimental and calculated performance data is compared over a range in speed up to 19,400 rpm (0.8 MDN) under pure radial, pure axial, and combined loads.

Kleckner, R. J.↗

Comparison of wind tunnel and theoretical aeroelastic predictions with flight measured airloads for the B-1 aircraft

An aeroelastic analysis of the B-1 aircraft was generated using the FLEXSTAB computer program. Relatively simple aerodynamic and structural models were employed. Theoretical wing and horizontal stabilizer airloads were compared to wind tunnel predictions and flight data measured during quasi-steady pitch maneuvers at Mach numbers of 0.85 and 1.2 with the wing in the 67.5 degree full aft sweep position. The basic objective was to evaluate the usefulness of the FLEXSTAB program for pre-flight airloads analysis of large flexible aircraft. Significant aeroelastic increments were noted between rigid and flexible vehicle results. FLEXSTAB predicted airloads for the outer wing panel were in good agreement with measured data for both rigid airloads and elastic increments. FLEXSTAB results for the horizontal stabilizer were useful for defining general aeroelastic trends, but absolute load levels were not well predicted due to theoretical limitations and difficulties encountered in modelling the complex B-1 configuration. Overall, the FLEXSTAB program is viewed as a useful integrated tool for static aeroelastic analysis in support of flight programs.

Sims, R. L.↗

Study on Auto-DR and Pre-Cooling of Commercial Buildings with Thermal Mass in California

This paper discusses how to optimize pre-cooling strategies for buildings in a hot California climate zone with the Demand Response Quick Assessment Tool (DRQAT), a building energy simulation tool. This paper outlines the procedure used to develop and calibrate DRQAT simulation models, and applies this procedure to eleven field test buildings. The results of a comparison between the measured demand savings during the peak period and the savings predicted by the simulation model indicate that the predicted demand shed match well with measured data for the corresponding auto-demand response (Auto-DR) days. The study shows that the accuracy of the simulation models is greatly improved after calibrating the initial models with measured data. These improved models can be used to predict load reductions for automated demand response events. The simulation results were compared with field test data to confirm the actual effect of demand response strategies. Results indicate that the optimal demand response strategies worked well for most of the buildings tested in this hot climate zone.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prediction and Validation of Mars Pathfinder Hypersonic Aerodynamic Data Base

Postflight analysis of the Mars Pathfinder hypersonic, continuum aerodynamic data base is presented. Measured data include accelerations along the body axis and axis normal directions. Comparisons of preflight simulation and measurements show good agreement. The prediction of two static instabilities associated with movement of the sonic line from the shoulder to the nose and back was confirmed by measured normal accelerations. Reconstruction of atmospheric density during entry has an uncertainty directly proportional to the uncertainty in the predicted axial coefficient. The sensitivity of the moment coefficient to freestream density, kinetic models and center-of-gravity location are examined to provide additional consistency checks of the simulation with flight data. The atmospheric density as derived from axial coefficient and measured axial accelerations falls within the range required for sonic line shift and static stability transition as independently determined from normal accelerations.

Gnoffo, Peter A.↗

Apparatus and method for radioactive waste screening

An apparatus and method relating to screening radioactive waste are disclosed for ensuring that at least one calculated parameter for the measurement data of a sample falls within a range between an upper limit and a lower limit prior to the sample being packaged for disposal. The apparatus includes a radiation detector configured for detecting radioactivity and radionuclide content of the of the sample of radioactive waste and generating measurement data in response thereto, and a collimator including at least one aperture to direct a field of view of the radiation detector. The method includes measuring a radioactive content of a sample, and calculating one or more parameters from the radioactive content of the sample.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sci—Thur AM: YIS - 05: 10X-FFF VMAT for Lung SABR: an Investigation of Peripheral Dose

Flattening Filter Free (FFF) beams exhibit high dose rates, reduced head scatter, leaf transmission and leakage radiation. For VMAT lung SABR, treatment time can be significantly reduced using high dose rate FFF beams while maintaining plan quality and accuracy. Another possible advantage offered by FFF beams for VMAT lung SABR is the reduction in peripheral dose. The focus of this study was to investigate and quantify the reduction of peripheral dose offered by FFF beams for VMAT lung SABR. The peripheral doses delivered by VMAT Lung SABR treatments using FFF and flattened beams were investigated for the Varian Truebeam linac. This study was conducted in three stages, (1): ion chamber measurement of peripheral dose for various plans, (2): validation of AAA, Acuros XB and Monte Carlo for peripheral dose using measured data, and (3): using the validated Monte Carlo model to evaluate peripheral doses for 6 VMAT lung SABR treatments. Three energies, 6X, 10X, and 10X-FFF were used for all stages. Measured data indicates that 10X-FFF delivers the lowest peripheral dose of the three energies studied. AAA and Acuros XB dose calculation algorithms were identified as inadequate, and Monte Carlo was validated for accurate peripheral dose prediction. The Monte Carlo-calculated VMAT lung SABR plans show a significant reduction in peripheral dose for 10X-FFF plans compared to the standard 6X plans, while no significant reduction was showed when compared to 10X. This reduction combined with shorter treatment time makes 10X-FFF beams the optimal choice for superior VMAT lung SABR treatments.

60 APPLIED LIFE SCIENCES↗