Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “material sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Digital Miniature Cathode Ray Magnetometer

In this study, we introduce the concept and construction of an innovative Digital Miniature Cathode Ray Magnetometer designed for the precise detection of magnetic fields. This device addresses several limitations inherent to magnetic probes such as D.C. offset, nonlinearity, temperature drift, sensor aging, and the need for frequent recalibration, while capable of operating in a wide range of magnetic fields. The core principle of this device involves the utilization of a charged particle beam as the sensitivity medium. The system leverages the interaction of an electron beam with a scintillator material, which then emits visible light that is captured by an imager. The emitted scintillation light is captured by a CMOS sensor. This sensor not only records the scintillation light but also accurately determines the position of the electron beam, providing invaluable spatial information crucial for magnetic field mapping. The key innovation lies in the combination of electron beam projection, CMOS imager scintillation-based detection, and digital image signal processing. By employing this synergy, the magnetometer achieves remarkable accuracy, sensitivity and dynamic range. The precise position registration enabled by the CMOS sensor further enhances the device’s utility in capturing complex magnetic field patterns, allowing for 2D field mapping. In this work, the optimization of the probe’s performance is tailored for applications related to the characterization of insertion devices in light sources, including undulators.

Turqueti, Marcos↗

SRF Thin Films: Not just for Cavities

Recent years have seen renewed interest and activities in developing SRF cavity materials based on thin film technologies. In this framework, considerable progress has been achieved in the development of high quality films and layered structures along with associated deposition techniques such as ECR, HiPIMS, and ALD. Beyond cavity applications, the developments in SRF thin film technologies find a variety of applications in the fields of superconducting metamaterials, electronics, sensors and quantum devices. High quality Nb films with high RRR open the way for enhanced coherence times for quantum qbits. Other SRF thin films such as NbTiN are developed for superconducting backend processes for future generations of computing hardware and radiation-hard sensors for nuclear and high-energy physics. The unifying theme across these technologies is that the same physics and material properties such as extreme low loss, stability, and manufacturability are required. This talk will present an overview of the emerging applications of SRF films and structures beyond accelerator cavities.

Valente-Feliciano, A.-M.↗

Enhanced detection of volatile organic compounds (VOCs) by caffeine modified carbon nanotube junctions

Detection of vapor phase analytes and gas molecules is primarily essential for numerous applications including medical diagnostic, environmental monitoring, chemical threat detection, food quality control, and chemical warfare agents. Here, we developed Caffeine functionalized carbon nanotubes (CNTs) random network based vapor quantum resistive sensors (vQRSs) for volatile organic compounds (VOCs) detection. The localized transmission electron microscopy (TEM) image and energy dispersive X-ray spectroscopy (EDS) confirm migration of caffeine to CNT–CNT junction (CNTj). We have recorded more than one order of magnitude higher sensitivity and unique selectivity towards selective VOCs (e.g., acetone, toluene, ethanol, methanol, etc.) with short response time (few seconds) for caffeine modified CNT junction (Caf-CNTj) vQRSs. Molecular dynamics (MD) calculations suggest that the sensitivity of the sensor is diffusion limited, with an advective contribution for ethanol. Furthermore, the designed Caf-CNTj sensors can potentially be important candidate to be a part of electronic nose used for various application such as breath analysis and food quality monitoring.

36 MATERIALS SCIENCE↗

Continuous MOF Membrane-Based Sensors via Functionalization of Interdigitated Electrodes

Three M-MOF-74 (M = Co, Mg, Ni) metal-organic framework (MOF) thin film membranes have been synthesized through a sensor functionalization method for the direct electrical detection of NO 2 . The two-step surface functionalization procedure on the glass/Pt interdigitated electrodes resulted in a terminal carboxylate group, with both steps confirmed through infrared spectroscopic analysis. This surface functionalization allowed the MOF materials to grow largely in a uniform manner over the surface of the electrode forming a thin film membrane over the Pt sensing electrodes. The growth of each membrane was confirmed through scanning electron microscopy (SEM) and X-ray diffraction analysis. The Ni and Mg MOFs grew as a continuous but non-defect free membrane with overlapping polycrystallites across the glass surface, whereas the Co-MOF-74 grew discontinuously. To demonstrate the use of these MOF membranes as an NO 2 gas sensor, Ni-MOF-74 was chosen as it was consistently fabricated as the best thin and homogenous membrane, as confirmed by SEM. The membrane was exposed to 5 ppm NO 2 and the impedance magnitude was observed to decrease 123× in 4 h, with a larger change in impedance and a faster response than the bulk material. Importantly, the use of these membranes as a sensor for NO 2 does not require them to be defect-free, but solely continuous and overlapping growth.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Piezochromic Behavior of 2,4,6-Triphenylpyrylium Tetrachloroferrate

In advanced photonics, there is a growing interest in piezochromic luminescent materials that exhibit multicolor switching, driven by their potential applications in optical recording, memory, and sensors. Here, the piezochromic behavior of 2,4,6-triphenylpyrylium tetrachloroferrate (Py-FeCl 4 ) under high pressures from 0 to 9 GPa is reported. The observed multicolor changing properties of Py-FeCl 4 (yellow–orange–red–maroon–black) are found to be fully reversible upon decompression to ambient conditions. The mechanism of Py-FeCl 4 piezochromism is investigated via Raman, infrared, and UV–vis spectroscopy combined with powder X-ray Diffraction. The absence of structural phase transitions as well as the abrupt shifts of bandgap values together with characteristic Raman and IR peaks within 0-9 GPa suggests that the Py-FeCl 4 multicoloring switching behavior is driven by an electron transfer between the inorganic FeCl 4 – anion and the organic pyrylium cation. The obtained results demonstrate that Py-FeCl 4 dye is a good candidate for developing high-pressure sensing technologies designed to function in extreme environments. Moreover, due to the inherent role of molecular-structure relationships in the pyrylium salt's photophysical properties, findings suggest the potential discovery of piezochromic behavior in other pyrylium compounds.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

ESSENCE- A rapid, shear-enhanced, flow-through, capacitive electrochemical platform for rapid detection of biomolecules

The rapid, sensitive, and selective detection of target analytes using electrochemical sensors are challenging. ESSENCE, a new Electrochemical Sensor that uses a Shear-Enhanced, flowthrough Nanoporous Capacitive Electrode, overcomes current electrochemical sensors' response limitations, selectivity, and sensitivity limitations. ESSENCE is a microfluidic channel packed with transducer material sandwiched by a top and bottom microelectrode. The room-temperature instrument less integration process allows the switch of the transducer materials to make up the porous electrode without modifying the electrode architecture or device protocol. ESSENCE can be used to detect both biomolecules and small molecules by simply changing the packed transducer material. Electron microscopy results confirm the high porosity. In conjunction with the non-planar interdigitated electrode, the packed transducer material results in a flow-through porous electrode. Electron microscopy results confirm the high porosity. The enhanced shear forces and increased convective fluxes disrupt the electric double layer's (EDL) diffusive process in ESSENCE. This disruption migrates the EDL to high MHz frequency allowing the capture signal to be measured at around 100 kHz, significantly improving device timing (rapid detection) with a low signal-to-noise ratio. The device’s unique architecture allows us multiple configuration modes for measuring the impedance signal. This allows us to use highly conductive materials like carbon nanotubes. We show that by combining single-walled carbon nanotubes as transducer material with appropriate capture probes, NP-µIDE has high selectivity and sensitivity for DNA (fM sensitivity, selective against non-target DNA), breast cancer biomarker proteins (p53, pg/L sensitivity, selective against non-target HER2).

Cheng, Yu-Hsuan↗

Ultrasonic measurement of temperature distributions in extreme environments: Electrical power plants testing in utility-scale steam generators

Thermal heterogeneities within energy conversion and storage, material processing, nuclear processes, aerospace, and military applications are often inaccessible to characterization by insertion sensors. When sensor deployment is possible, conventional pointwise temperature probes quickly degrade when inserted into harsh environments typical of such processes. We developed spatially-resolved ultrasonic thermometry to noninvasively measure the spatial distributions of thermal properties in such applications, even when sizable thermal gradients are present. Our method divides the path of ultrasonic propagation into segments bound by echogenic features, which create echoes in pulse-echo mode, encoding the information about interior temperature distributions. We use the acquired ultrasonic responses to estimate the internal temperature distributions by solving an inverse problem or concatenating segmental estimates. This work describes the implementation and industrial testing of the developed method at a coal-fired electrical power generation plant. We inserted an echogenically segmented Inconel 625 waveguide into the combustion zone of the utility-scale boiler and continuously acquired ultrasonic data while keeping sensitive components away from the damaging combustion environment. The accuracy of the time-dependent temperature distributions reconstructed from the ultrasonic measurements was comparable to that of thermocouples. The resiliency of ultrasonic thermometry to harsh combustion conditions was far superior to conventional insertion sensors. The measurements obtained during plant operation captured daily steam generation cycles in response to changing customer demand and intermittent contributions of renewable power sources to the power grid. These measurements have revealed new insights into the relationship between the dynamic power generation load and the conditions inside the steam generator. As a result, the successful industrial testing of spatially-resolved ultrasonic thermometry in solids indicates that the developed technology has matured to become an attractive alternative to conventional sensing in solving challenging problems of long-term thermal characterizations in extreme environments.

42 ENGINEERING↗

Protein-Mimetic Self-Assembly with Synthetic Macromolecules

Protein-mimetic amphiphiles have significant promise as a platform to access the complex functions of natural biological materials and incorporate the tunability and environmental resilience of synthetic materials. The fields of polymer chemistry and chemical biology have concurrently approached the development of biomimetic amphiphiles with materials ranging from random amphiphilic copolymers to peptide–lipid conjugates. In this Perspective, we incorporate strategies from diverse chemical arenas for controlling assembled morphologies and dynamics of protein-mimetic synthetic macromolecules. An overview of significant advances in peptide amphiphiles and single-chain polymer nanoparticles provides the foundation for comparing recent advances in the implementation of multiple intermolecular interactions and computational strategies to fine-tune the assembled structures. We aim to bridge these fields, combining insights from multiple disciplines to inspire new approaches for the development of protein-mimetic materials, as these assemblies have far-reaching applications including in the development of new sensors, catalysts, and therapeutics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mutual Inductance Level Sensor for Use in Liquid Metals

Electromagnetic instrumentation capable of measuring the level of liquid metal has been developed at Argonne National Laboratory’s (ANL) Mechanisms Engineering Test Loop (METL). The mutual inductance level sensor (MILS) utilizes the electromagnetic coupling between two coil conductors and a surrounding liquid metal to determine the level of the liquid metal. Mineral insulated cables wrapped on a stainless steel core provide a durable sensor construction. The use of a sealed stainless steel thimble isolates the sensor from the high-temperature liquid metal, allowing for easy sensor maintenance. Modern digital electronics allow for reliable and accurate operation of the sensor. Two sensor variations have been designed and fabricated, and the first variation has seen extensive testing in a non-sodium testing stand as well as in the high-temperature sodium environment of METL. Electromagnetic finite-element analysis studies have been performed using the COMSOL Magnetic Fields Solver. Regular operation of the MILS will commence following in-situ calibration of the sensors in the METL environment.

36 MATERIALS SCIENCE↗

Development of an optical sensor for measuring opacity changes in polyvinyl toluene scintillators

Polyvinyl toluene (PVT) based detectors are used in radiation portal monitors (RPMs) worldwide to detect the trafficking of illicit nuclear material. PVT scintillators, which are normally optically clear, have been observed to suffer internal fogging throughout their volume due to prolonged exposure to varying environmental conditions. These changes could lead to reduced performance for RPMs that utilize plastic scintillators. In this research, a proof of concept system, consisting of different color light emitting diodes (LEDs) and a single optical sensor (OS), were used to examine the change in light transmission through a PVT scintillator. This Optical Monitoring System (OMS), coupled with an environmentally exposed PVT detector, was tested in an environmental chamber where it was subjected to changes in temperature and humidity ranging from 55 °C at 100% relative humidity to –20 °C at 40% relative humidity. At temperatures below 10 °C, light transmission was reduced by 81% ± 8% for blue LEDs, 84% ± 5% for yellow LEDs, and 49% ± 4% for green LEDs. Similar reductions in detected light were not recorded when the OMS was tested with only air between the LEDs and OS. Therefore, the significant reductions in transmitted light were attributed to changes occurring within the PVT scintillator. These results indicate that a significant reduction in PVT opacity occurs due to wide environmental changes. A device such as the OMS could be used to track these changes and provide users an early indication that a portal monitor is suffering from reduced performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved plutonium and americium photon branching ratios from microcalorimeter gamma spectroscopy

Photon branching ratios are critical input data for activities such as nuclear materials protection and accounting because they allow material compositions to be extracted from measurements of gamma-ray intensities. Uncertainties in these branching ratios are often a limiting source of uncertainty in composition determination. Here, we use high statistics, high resolution - (60–70 eV full-width-at-half-maximum at 100 keV) gamma-ray spectra acquired using microcalorimeter sensors to substantially reduce the uncertainties for 11 plutonium ( 238 Pu, 239 Pu, 241 Pu) and 241 Am branching ratios important for material control and accountability and nuclear forensics in the energy range of 125 keV to 208 keV. Lastly, we show a reduction in uncertainty of over a factor of three for one branching ratio and a factor of 2–3 for four branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A ruthenium oxide thermometer for dilution refrigerators operating down to 5 mK

At the lowest temperatures achieved in dilution refrigerators, ruthenium oxide resistance thermometers often saturate and therefore lose their sensitivity. In an effort to extend the range of such temperature sensors, we built a thermometer which maintains sensitivity to 5 mK. A key component of this thermometer is an in situ radio frequency filter which is based on a modern rf absorption material. Here, we show that the use of such a filter is only effective when it is encased in the same rf-tight enclosure as the ruthenium oxide sensor. Our design delivers an attenuation level that is necessary to mitigate the effects of parasitic heating of a fraction of pW present in our circuit. Furthermore, we show that the likely origin of this parasitic heating is the black body radiation present within the experimental space of the refrigerator. We found that the equilibration time of the thermometer increases rapidly as the temperature is lowered; below 5 mK this thermometer becomes impractical because of the prohibitively long equilibration times.

47 OTHER INSTRUMENTATION↗

A Digital Twin Approach to Study Additive Manufacturing Processing Using Embedded Optical Fiber Sensors and Numerical Modeling

One of the major challenges for metal-powder-based additive manufacturing is measuring and mitigating residual strain induced during the manufacturing processes. This article reports distributed fiber optic sensors embedded in Inconel alloy components as experimental means to validate numerical models of additive manufacturing process. Electroplating was used to deposit a metal protective jacket onto standard telecom single-mode fibers for strain measurements, Fiber sensors were embedded in an Inconel alloy substrate using the laser engineered net shaping (LENS) process. Here by using a Rayleigh-scattering optical frequency domain reflectometer (OFDR), temperature changes, and residual strain in the metal substrate were monitored with 5 mm spatial resolution during the LENS process. Using finite element analysis, temperature and strain profiles induced by the LENS deposition processes were also numerically studied. Discrepancies between the simulated temperature and strain profiles and those measured directly were less than 10%. Results presented in this article demonstrates a digital twin approach to fuse modeling results with distributed fiber sensor measurement data to study additive manufacturing process toward design and fabrication process optimization.

36 MATERIALS SCIENCE↗

Layer-wise Imaging Dataset from Powder Bed Additive Manufacturing Processes for Machine Learning Applications (Peregrine v2022-10)

This release consists of six datasets which together include multi-modal layer-wise powder bed images from two different powder bed printing technologies. These datasets are designed primarily to facilitate the development and testing of new computer vision and machine learning based anomaly and defect detection algorithms. The authors provide both training data with corresponding ground truth pixel masks and evaluation data with corresponding baseline prediction pixel masks made by a trained neural network. The laser powder bed fusion (L-PBF) datasets are sourced from EOS M290 and AddUp FormUp 350 printers and the binder jet (BJ) dataset is sourced from an ExOne M-Flex printer. The materials represented in these datasets include 17-4 PH Stainless Steel, DMREF, Inconel 718, Maraging Steel, and H13 Steel. The sensor imaging modalities represented include visible-light (VL), temporally-integrated (i.e., long duration exposure) near-infrared (TI-NIR), and wide-band infrared (IR).

36 MATERIALS SCIENCE↗

Temperature-independent giant dielectric response in transitional BaTiO 3 thin films

Ferroelectric materials exhibit the largest dielectric permittivities and piezoelectric responses in nature, making them invaluable in applications from supercapacitors or sensors to actuators or electromechanical transducers. The origin of this behavior is their proximity to phase transitions. However, the largest possible responses are most often not utilized due to the impracticality of using temperature as a control parameter and to operate at phase transitions. This has motivated the design of solid solutions with morphotropic phase boundaries between different polar phases that are tuned by composition and that are weakly dependent on temperature. Thus far, the best piezoelectrics have been achieved in materials with intermediate (bridging or adaptive) phases. But so far, complex chemistry or an intricate microstructure has been required to achieve temperature-independent phase-transition boundaries. Here, we report such a temperature-independent bridging state in thin films of chemically simple BaTiO3. A coexistence among tetragonal, orthorhombic, and their bridging low-symmetry phases are shown to induce continuous vertical polarization rotation, which recreates a smear in-transition state and leads to a giant temperature-independent dielectric response. The current material contains a ferroelectric state that is distinct from those at morphotropic phase boundaries and cannot be considered as ferroelectric crystals. We believe that other materials can be engineered in a similar way to contain a ferroelectric state with gradual change of structure, forming a class of transitional ferroelectrics. Similar mechanisms could be utilized in other materials to design low-power ferroelectrics, piezoelectrics, dielectrics, or shape-memory alloys, as well as efficient electro- and magnetocalorics.

36 MATERIALS SCIENCE↗

Engineering Metal Oxide Nanomaterials for Fiber Optical Sensor Platforms (Final Report)

In this research program, the recipient will explore nano-engineered metal oxides, a class of important sensory materials, for fiber optic chemical sensing for high-temperature energy applications using both silica and sapphire fibers as sensing platforms. This final report documents all project accomplishments with the project goals and objectives listed for the reporting period.

01 COAL, LIGNITE, AND PEAT↗

Results of South-East Flux Trap Dosimetry Measurements for the Advanced Test Reactor Critical Facility in support of Advanced Sensors and Instrumentation Development

Reactor dosimetry measurements are commonly used to validate simulation and modeling in nuclear reactor tests. Numerous standard dosimeter materials exist which are commonly utilized with sensitivities to different energy ranges of neutrons. At the Advanced Test Reactor (ATR), cobalt alloy and pure nickel wires are installed every cycle to monitor thermal- and fast-neutron fluence rates. However, there is growing interest in exploring less commonly used materials which are either more sensitive to different parts of the neutron energy spectrum or which can incorporate multiple activation paths in a single material. Epithermal and fast-neutron energies beyond the typical 1-MeV threshold are of particular interest. Two ATR-C Flux Runs took place during 2024; each flux run included supplemental dosimetry packages in the South-East Flux Trap (SEFT) Filler. The focus of the dosimetry package for flux run 23-4 was to test two novel dosimetry methods that can provide simultaneous thermal and threshold (fast) sensitivity in a single dosimeter wire. A selection of 3% Au in Cu alloyed wires were available that provided sensitivity to fast and thermal neutrons through 5 different reactions. Likewise, Fe offers multiple interaction pathways with sensitivity to both thermal and fast neutrons. The main question to be answered by these irradiations was if sufficient radioactivation would take place in the ATR-C SEFT during a nominal 20-minute irradiation at typical power levels (near 600Wth) to observe the threshold reactions that have smaller activation cross-sections than the thermal reactions without being saturated by interfering interactions and Compton continuum during the High-Purity Germanium (HPGe) measurements. The results from comparing the measurement results to anticipated activity levels provide confidence in our ability to activate both traditional and novel dosimetry materials in ATR-C, however not all the measured values matched with the predicted activities. This leaves further room for investigation both on the experimental and computational approaches for future irradiation experiments.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Science Breakthroughs 2030. Final report

Agriculture is a fundamental societal activity, characterized by many different landscapes, crops, markets, and participants. Food, agricultural, and biofuels products are central to the daily life of all citizens, though most do not recognize the fragility of the environment that brings forth this abundance. As is noted in the 2012 report from the President's Council of Advisors on Science and Technology, Agricultural Preparedness and the United States Agricultural Research Enterprise (PCAST, 2012) the food and agricultural system faces constant challenges in: Managing new pests, pathogens, and invasive plants. Increasing the efficiency of water use. Growing food in a changing climate. Reducing the environmental footprint of agriculture. Managing the production of bioenergy. Producing safe and nutritious food. Assisting with global food security and maintaining abundant yields. Science Breakthroughs 2030 was organized to identify the most compelling research directions in food and agriculture, in particular those empowered by the application of insights and tools from disciplines of science and engineering not typically associated with food and agricultural research. A committee appointed by the Chairman of the National Research Council explored ideas for research directions with input from the scientific community, with the objective of producing a report describing ambitious and achievable scientific pathways to address major problems and create new opportunities in food and agriculture. Following numerous meetings, a jamboree, and town hall, the appointed committee prepared a report that has subsequently become a reference for federal agencies supporting research in the food and agricultural space. It highlights five key areas for research investment with broad application across food and agriculture: integrated systems research; sensor development; data mining and information sciences, genomics; and the microbiome.

09 BIOMASS FUELS↗