Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “low dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Implications of outer-zone radiations on operations in the geostationary region utilizing the AE4 environmental model

The radiation exposure in the region of geostationary orbits is examined in search for means of optimizing human performance. It is found that the use of slightly inclined circular orbits is one means by which exposure and spacesuit thickness requirements can be reduced. Another effective technique is to limit the extravehicular activity to those days when the short term fluctuations result in low exposure. Space-suit shielding approaching 1/2 sq cm or less may be possible by utilizing work stoppages and inclined orbits. If aluminum and other low-atomic-number materials are used to construct the habitat, then excessive wall thicknesses are required. If special bremsstrahlung shielding is used, then the habitat shield may be reduced to as low as 2 g/sq cm. Numerous tables and graphs are presented for future analysis of dose in the geostationary region.

Wilson, J. W.↗

Radiation effects on selected electronics parts from the solar max satellite

The Solar Maximum Satellite was launched on February 14, 1980. Problems with the Main Electronics Box (MEB) were experienced in the period July 10 to September 30, 1980. Failure occurred in the October to November time frame. Replacement of the Main Electronic Box (MEB) was performed in April 1984. The failed original MEB was returned to Earth and offered an opportunity to study some electronic parts which had spent 50 months in the natural radiation environment of a low Earth orbit (LEO) spacecraft. Spare parts were annealed at ambient temperatures on the ground. Dose rate effects between the flight and laboratory environments were compared.

R H Maurer↗

Mutation induction in bacteria after heavy ion irradiation

From a compilation of experimental data on the mutagenic effects of heavy ions in bacteria, main conclusions have been drawn as follows: (1) The mutagenic efficacy of heavy ions in bacteria depends on physical and biological variables. Physical variables are the radiation dose, energy and charge of the ion; the biological variables are the bacterial strain, the repair genotype of bacteria, and the endpoint investigated (type of mutation, induction of enzymes related to mutagenesis); (2) The responses on dose or fluence are mainly linear or linear quadratic. The quadratic component, if found for low LET radiation, is gradually reduced with increasing LET; (3) At low values of Z and LET the cross section of mutation induction sigma m (as well as SOS response, sigma sos. and lambda phage induction, sigma lambda versus LET curves can be quite consistently described by a common function which increases up to approximately 100 keV/mu m. For higher LET values, the sigma(m) versus LET curves show the so-called 'hooks' observed also for other endpoints; (4) For light ions (Z is less than or equal to 4), the cross sections mostly decrease with increasing ion energy, which is probably related to the decrease of the specific energy departed by the ion inside the sensitive volume (cell). For ions in the range of Z = 10, sigma(m) is nearly independent on the ion energy. For heavier ions (Z is greater than or equal to 16), sigma(m) increases with the energy up to a maximum or saturation around 10 MeV/u. The increment becomes steeper with increasing atomic number of the ion. It correlates with the increasing track radius of the heavy ion; (5) The mutagenic efficiency per lethal event changes slightly with ion energy, if Z is small indicating a rough correlation between cellular lethality and mutation induction, only. For ions of higher Z this relation increases with energy, indicating a change in the 'mode' of radiation action from 'killing-prone' to 'mutation-prone'; and (6) Repair genotype substantially influences the radiation induced mutagenesis. Different mechanisms of mutation induction and/or different types of biologically significant lesions in wild type cells compared to repair deficient strains are a likely explanation.

Horneck, G.↗

Estimating Sonic Boom Metrics Across a Community Using a Kalman Filter

As part of the Quesst mission, NASA will fly the X‑59 aircraft over selected communities to evaluate community responses to low-intensity sonic booms. The purpose of these community tests is to determine the dose-response relationship between the noise exposure metrics and the community response. The independent variables for the dose-response relationship are the noise exposure metrics experienced by survey respondents within the community. Two sources of noise exposure metrics are available in each community: measurements at sparse locations throughout the community, and calculations from propagation models across the community. Both the measurements and calculations are subject to uncertainty. A Kalman filter is proposed to combine the measured and calculated noise exposure metrics to obtain the best estimate of the true noise exposure metrics across the community. The noise exposure metrics estimated by the Kalman filter have lower uncertainty than either the measured or calculated noise exposure metrics alone. Simulations demonstrate that the Kalman filter produces a more accurate estimate of the true noise exposure metrics than other noise estimation methods.

Sonic boom↗

Decreasing Proton Single Event Effects in CubeSats with Shielding

Shields-1, NORAD ID 43850,has been operating in polar low earth orbit since December 2018. The shielding has resulted in a lower total ionizing dose over time than typical aluminum thin-walled CubeSat structures. The reduced ionizing dosage caused by Shields-1 increases the reliability of commercial parts and reduces internal charging. Furthermore, the Shields-1 shielding reduces the ionizing particle fluence inside the spacecraft that contributes to the ionizing dose. NOVICE Sigma shielding software, using the (Aerospace Proton) AP8 –(Aerospace Electron) AE8 solar minimum trapped belt environment for a 1-year mission, estimates a 21.3 g/cm2 aluminum effective shielding for the Shields-1 electronics enclosure. This high areal density reduces not only the total number of energetic protons, but also reduces the number of ionizing particles over all modeled energies from the estimated shielded fluence for a 1-year mission. NOVICE Adjoint CAD modeling of the Shields-1 structure, with the detector located within the electronics enclosure, estimates that the total number of particles is reduced from 2.20x 10exp9 protons/cm2 to 1.52x 10exp8 protons/cm2, which represents 6.90% of the remaining particles(figure 1). By slowing down approximations of the integral proton fluence, a minimum proton threshold is estimated at 151 MeV. In comparison, a 0.204-cm aluminum thin-walled 3-unit (U) structure, with a 0.907 g/cm2 effective shielding, has 25.0% remaining particles and a minimum proton threshold of 36.2 MeV(figure 1). Proton energies that contribute to single event effects in radiation tolerant or higher semiconductor hardness are typically 100 MeV and higher. The Shields-1 electronics enclosure is estimated to attenuate energies: 100 MeV by 76.5%, 200 MeV by 61.7%, and 500 MeV by 63.0%(figure 2), when comparing the space environment proton differential fluence with the shielded differential fluence. The aluminum thin-walled structure is estimated to attenuate proton energies: 100 MeV by 13.7%, 200 MeV by 12.4%, and 500 MeV by 12.6%(figure 2), which are lower than for the Shields-1 electronics enclosure. The significant differences in attenuation between the Shields-1 electronics enclosure and aluminum thin-walled 3U structure show the additional utility of increasing shielding effectiveness for reducing the numbers of energetic protons that contribute to single event effects.

Larry Thomsen↗

Depth dependence of absorbed dose, dose equivalent and linear energy transfer spectra of galactic and trapped particles in polyethylene and comparison with calculations of models

A matched set of five tissue-equivalent proportional counters (TEPCs), embedded at the centers of 0 (bare), 3, 5, 8 and 12-inch-diameter polyethylene spheres, were flown on the Shuttle flight STS-81 (inclination 51.65 degrees, altitude approximately 400 km). The data obtained were separated into contributions from trapped protons and galactic cosmic radiation (GCR). From the measured linear energy transfer (LET) spectra, the absorbed dose and dose-equivalent rates were calculated. The results were compared to calculations made with the radiation transport model HZETRN/NUCFRG2, using the GCR free-space spectra, orbit-averaged geomagnetic transmission function and Shuttle shielding distributions. The comparison shows that the model fits the dose rates to a root mean square (rms) error of 5%, and dose-equivalent rates to an rms error of 10%. Fairly good agreement between the LET spectra was found; however, differences are seen at both low and high LET. These differences can be understood as due to the combined effects of chord-length variation and detector response function. These results rule out a number of radiation transport/nuclear fragmentation models. Similar comparisons of trapped-proton dose rates were made between calculations made with the proton transport model BRYNTRN using the AP-8 MIN trapped-proton model and Shuttle shielding distributions. The predictions of absorbed dose and dose-equivalent rates are fairly good. However, the prediction of the LET spectra below approximately 30 keV/microm shows the need to improve the AP-8 model. These results have strong implications for shielding requirements for an interplanetary manned mission.

Flight Experiment↗

DNA Repair Domain Modeling Can Predict Cell Death and Mutation Frequency for Wide Range Spectrum of Radiation

Exploration missions to Mars and other destinations raise many questions about the health of astronauts. The continuous exposure of astronauts to galactic cosmic rays is one of the main concerns for long-term missions. Cosmic ionizing radiations are composed of different ions of various charges and energies notably, highly charged energy (HZE) particles. The HZE particles have been shown to be more carcinogenic than low-LET radiation, suggesting the severity of chromosomal aberrations induced by HZE particles is one possible explanation. However, most mathematical models predicting cell death and mutation frequency are based on directly fitting various HZE dose response and are in essence empirical approaches. In this work, we assume a simple biological mechanism to model DNA repair and use it to simultaneously explain the low- and high-LET response using the exact same fitting parameters. Our work shows that the geometrical position of DNA repair along tracks of heavy ions are sufficient to explain why high-LET particles can induce more death and mutations. Our model is based on assuming DNA double strand breaks (DSBs) are repaired within repair domain, and that any DSBs located within the same repair domain cluster into one repair unit, facilitating chromosomal rearrangements and increasing the probability of cell death. We introduced this model in 2014 using simplified microdosimetry profiles to predict cell death. In this work, we collaborated with NASA Johnson Space Center to generate more accurate microdosimetry profiles derived by Monte Carlo techniques, taking into account track structure of HZE particles and simulating DSBs in realistic cell geometry. We simulated 224 data points (D, A, Z, E) with the BDSTRACKS model, leading to a large coverage of LET from ~10 to 2,400 keV/μm. This model was used to generate theoretical RBE for various particles and energies for both cell death and mutation frequencies. The RBE LET dependence is in agreement with experimental data known in human and murine cells. It suggests that cell shape and its orientation with respect to the HZE particle beam can modify the biological response to radiation. Such discovery will be tested experimentally and, if proven accurate, will be another strong supporting evidence for DNA repair domains and their critical role in interpreting cosmic radiation sensitivity.

Viger, Louise↗

Hypothermic and antipyretic effects of ACTH (1-24) and alpha-melanotropin in guinea-pigs

Intracerebroventricular administration of adrenocorticotropin (ACTH 1-24) and alpha-melanotropin (alpha-MSH), peptides which occur naturally in brain induced dose-related hypothermia in guinea-pigs at room temperature (21 C) and also produced greater hypothermia at low (10 C) ambient temperature. However, when the experiments were repeated in a warm (30 C) environment, no effect on body temperature was observed. These results indicate that the peptides did not reduce the central set-point of temperature control. The hypothermia induced by ACTH and alpha-MSH was not mediated via histamine H1- or H2-receptors and serotonin since the H1-receptor antagonist, mepyramine, the H2-receptor antagonist, cimetidine, and the serotonin antagonist, methysergide, had no antagonistic effects. The peptides were antipyretic since they reduced pyrogen-induced-fever and hyperthermia due to prostaglandin E2, norepinephrine and dibutyryl cAMP, at a dose which did not affect normal body temperature. The powerful central effects of these peptides on normal body temperature, fever and hyperthermia, together with their presence of the brain regions important to temperature control, suggest that they participate in thermoregulation.

Kandasamy, S. B.↗

Passive dosimetry aboard the Mir Orbital Station: internal measurements

Passive radiation dosimeters were exposed aboard the Mir Orbital Station over a substantial portion of the solar cycle in order to measure the change in dose and dose equivalent rates as a function of time. During solar minimum, simultaneous measurements of the radiation environment throughout the habitable volume of the Mir were made using passive dosimeters in order to investigate the effect of localized shielding on dose and dose equivalent. The passive dosimeters consisted of a combination of thermoluminescent detectors to measure absorbed dose and CR-39 PNTDs to measure the linear energy transfer (LET) spectrum from charged particles of LET infinity H2O > or = 5 keV/micrometers. Results from the two detector types were then combined to yield mean total dose rate, mean dose equivalent rate, and average quality factor. Contrary to expectations, both dose and dose equivalent rates measured during May-October 1991 near solar maximum were higher than similar measurements carried out in 1996-1997 during solar minimum. The elevated dose and dose equivalent rates measured in 1991 were probably due to a combination of intense solar activity, including a large solar particle event on 9 June 1991, and the temporary trapped radiation belt created in the slot region by the solar particle event and ensuing magnetic storm of 24 March 1991. During solar minimum, mean dose and dose equivalent rates were found to vary by factors of 1.55 and 1.37, respectively, between different locations through the interior of Mir. More heavily shielded locations tended to yield lower total dose and dose equivalent rates, but higher average quality factor than did more lightly shielding locations. However, other factors such as changes in the immediate shielding environment surrounding a given detector location, changes in the orientation of the Mir relative to its velocity vector, and changes in the altitude of the station also contributed to the variation. Proton and neutron-induced target fragment secondaries, not primary galactic cosmic rays, were found to dominate the LET spectrum above 100 keV/micrometers. This indicates that in low earth orbit, trapped protons in the South Atlantic Anomaly are responsible for the major fraction of the total dose equivalent. c2002 Elsevier Science Ltd. All rights reserved.

NASA Experiment Number 9401620↗

Heavy ion track-structure calculations for radial dose in arbitrary materials

The delta-ray theory of track structure is compared with experimental data for the radial dose from heavy ion irradiation. The effects of electron transmission and the angular dependence of secondary electron ejection are included in the calculations. Several empirical formulas for electron range and energy are compared in a wide variety of materials in order to extend the application of the track-structure theory. The model of Rudd for the secondary electron-spectrum in proton collisions, which is based on a modified classical kinematics binary encounter model at high energies and a molecular promotion model at low energies, is employed. For heavier projectiles, the secondary electron spectrum is found by scaling the effective charge. Radial dose calculations for carbon, water, silicon, and gold are discussed. The theoretical data agreed well with the experimental data.

Cucinotta, Francis A.↗

Space Environment Effects: Low-Altitude Trapped Radiation Model

Accurate models of the Earth's trapped energetic proton environment are required for both piloted and robotic space missions. For piloted missions, the concern is mainly total dose to the astronauts, particularly in long-duration missions and during extravehicular activity (EVA). As astronomical and remote-sensing detectors become more sensitive, the proton flux can induce unwanted backgrounds in these instruments. Due to this unwanted background, the following description details the development of a new model for the low-trapped proton environment. The model is based on nearly 20 years of data from the TIRO/NOAA weather satellites. The model, which has been designated NOAAPRO (for NOAA protons), predicts the integral omnidirectional proton flux in three energy ranges: >16, >36, and >80 MeV. It contains a true solar cycle variation and accounts for the secular variation in the Earth's magnetic field. It also extends to lower values of the magnetic L parameter than does AP8. Thus, the model addresses the major shortcomings of AP8.

Huston, S. L.↗

Potential Dietary Countermeasure Against Spaceflight-Induced Bone Loss

As humans venture further into space and beyond low Earth orbit, space radiation is one of the main challenges for astronauts' health. Radiation-induced bone loss is a potential health problem for long duration habitation in space. We showed that a dietary countermeasure prevents bone loss in mice exposed to total body irradiation (TBI). We used a range of ionizing radiation, gamma (137Cs), proton (1H), iron (56Fe), and a combination of sequential proton and iron beam (1H/56Fe/1H) to evaluate skeletal responses. These TBI cover a range of linear energy transfer (LET), from low-LET such as proton, to high-LET such as 56Fe (HZE: high Z- high energy) at doses between 1-2 Gy. The countermeasure diet, composed of 25% Dried Plum (DP) was effective at preventing radiation-induced cancellous bone loss in appendicular bone (tibia). Furthermore, exposing mice to HZE radiation, such as 56Fe (1Gy), impaired ex vivo growth of marrow-derived, bone-forming osteoblasts, which led to reduced mineralization capacity (-77%). In contrast, mice fed the DP diet did not display these deficits, showing the diet's capacity to protect marrow-derived osteoprogenitors. Dietary DP prevented the increase of bone resorbing osteoclast cells, inflammation and oxidative stress, while protecting the osteoprogenitors and mesenchymal stem cells, which few drugs against osteoporosis may achieve. Spaceflight is a combination of multiple factors including microgravity, in addition to space radiation. Therefore, we conducted additional studies to determine if the DP diet could prevent simulated spaceflight (simulated microgravity and radiation combined) bone loss. Mice were exposed to gamma (TBI, 137Cs, 2 Gy), simulated microgravity (using the hindlimb unloading system, HU) or TBI+HU. While we observed bone loss in mice fed the control diet (CD) due to both treatments (TBI=14%, HU=20%), and a worse effect with combined treatments (TBI+HU=25%), mice fed the DP diet did not sustain significant bone loss relative to untreated controls. The DP diet prevented microarchitectural decrements in both appendicular bone (tibia) and axial bone (vertebrae). In addition, the DP diet mitigated HU-induced deficits in osteoblastogenesis. Interestingly, lower doses of DP diet (5%, 10%) did not appear to prevent cancellous bone loss, which shows the importance of identifying the active component(s) of DP. Finally, we have preliminary data showing the potential of DP to prevent radiation-induced damage at a systematic level.. In summary, this novel dietary countermeasure is a promising candidate nutritional countermeasure for spaceflight-induced bone loss and tissue damage.

Countermeasure↗

Commercial Off-The-Shelf (COTS) Graphics Processing Board (GPB) Radiation Test Evaluation Report

Large round trip communications latency for deep space missions will require more onboard computational capabilities to enable the space vehicle to undertake many tasks that have traditionally been ground-based, mission control responsibilities. As a result, visual display graphics will be required to provide simpler vehicle situational awareness through graphical representations, as well as provide capabilities never before done in a space mission, such as augmented reality for in-flight maintenance or Telepresence activities. These capabilities will require graphics processors and associated support electronic components for high computational graphics processing. In an effort to understand the performance of commercial graphics card electronics operating in the expected radiation environment, a preliminary test was performed on five commercial offthe- shelf (COTS) graphics cards. This paper discusses the preliminary evaluation test results of five COTS graphics processing cards tested to the International Space Station (ISS) low earth orbit radiation environment. Three of the five graphics cards were tested to a total dose of 6000 rads (Si). The test articles, test configuration, preliminary results, and recommendations are discussed.

Salazar, George A.↗

TOC Calibration Method for Exploration Application

Total organic carbon (TOC) is the amount of carbon associated with organic compounds in solution and is often used as a non-specific indicator for water quality or cleanness. Currently, the Total Organic Carbon Analyzer (TOCA) is being used onboard the International Space Station (ISS) for water recovery system process control. An exploration-class TOCA is now being developed to close the technology gaps between the State-of-the-Art ISS TOCA and the emerging requirements of future exploration missions. One of the technical gaps for an exploration TOC analyzer is the development of suitable methods for on-orbit calibration. While the ISS TOCA uses pre-packaged ground-supplied TOC calibration standards, there is limited stability data. Other options include preparing calibration standards in space, which can be challenging due to the lack of low TOC reagent water. This paper explores the practice of the standard addition method and passive dosing approaches as potential solutions to overcome this problem.

Wenyan Li↗

Low-dosage micronized 17 beta-estradiol prevents bone loss in postmenopausal women

With the use of a double-blind, randomized, dose-ranging design, we tested during an 18-month period the degree of protection against postmenopausal bone loss afforded by micronized 17 beta-estradiol in dosages of 0.5, 1.0, and 2.0 mg. All subjects received supplementation to ensure a minimum of 1500 mg calcium daily. Fifty-one subjects completed at least 1 year of follow-up bone density measurements by quantitative computed tomography and by single- and dual-photon absorptiometry. In the placebo group spinal trabecular bone density decreased 4.9% annually (p less than 0.001), whereas in those taking micronized 17 beta-estradiol bone density tended to increase (annual increases of 0.3% in the 0.5 mg micronized 17 beta-estradiol group, 1.8% in the 1.0 mg micronized 17 beta-estradiol group, and 2.5% in the 2.0 mg micronized 17 beta-estradiol group). After completing the double-blind phase, 41 subjects completed an additional 18 months of follow-up while taking 1.0 mg micronized 17 beta-estradiol. During this time one third of the subjects were randomly assigned to discontinue calcium supplements. Among those who previously received placebo, trabecular bone density increased 4.3% annually, whereas among those who had used micronized 17 beta-estradiol, trabecular bone density response was inversely related to the dosage previously used. Additionally and independently, the level of calcium intake showed a statistically significant correlation with the change in spinal trabecular bone density (r = 0.37, p = 0.02). We conclude that micronized 17 beta-estradiol has a continuous skeletal dose-response effect in the range of 0.5 to 2.0 mg and that calcium intake positively modifies the skeletal response to 1.0 mg micronized 17 beta-estradiol.

Randomized Controlled Trial↗

Radiation model predictions and validation using LDEF satellite data

Predictions and comparisons with the radiation dose measurements on Long Duration Exposure Facility (LDEF) by thermoluminescent dosimeters were made to evaluate the accuracy of models currently used in defining the ionizing radiation environment for low Earth orbit missions. The calculations include a detailed simulation of the radiation exposure (altitude and solar cycle variations, directional dependence) and shielding effects (three-dimensional LDEF geometry model) so that differences in the predicted and observed doses can be attributed to environment model uncertainties. The LDEF dose data are utilized to assess the accuracy of models describing the trapped proton flux, the trapped proton directionality, and the trapped electron flux.

Armstrong, T. W.↗

Status of LDEF ionizing radiation measurements and analysis

At this symposium significant new data and analyses were reported in cosmic ray research, radiation dosimetry, induced radioactivity, and radiation environment modeling. Measurements of induced radioactivity and absorbed dose are nearly complete, but much analysis and modeling remains. Measurements and analyses of passive nuclear track detectors (PNTD), used to derive the cosmic ray composition and spectra, and linear energy transfer (LET) spectra, are only a few percent complete, but important results have already emerged. As one might expect at this stage of the research, some of the new information has produced questions rather than answers. Low-energy heavy nuclei detected by two experiments are not compatible with known solar or cosmic components. Various data sets on absorbed dose are not consistent, and a new trapped proton environment model does not match the absorbed dose data. A search for cosmogenic nuclei other than Be-7 on Long Duration Exposure Facility (LDEF) surfaces has produced an unexpected result, and some activation data relating to neutrons is not yet understood. Most of these issues will be resolved by the analysis of further experiment data, calibrations, or the application of the large LDEF data set that offers alternate data or analysis techniques bearing on the same problem. The scope of the papers at this symposium defy a compact technical summary. I have attempted to group the new information that I noted into the following groups: induced radioactivity; absorbed dose measurements; LET spectra and heavy ion dosimetry; environment modeling and three dimensional shielding effects; cosmogenic nuclei; and cosmic rays and other heavy ions. The papers generally are expository and have excellent illustrations, and I refer to their figures rather than reproduce them here. The general program and objectives of ionizing radiation measurements and analyses on LDEF has been described previously.

Parnell, Thomas A.↗

Dose-response relationship between sleep duration and human psychomotor vigilance and subjective alertness

Although it has been well documented that sleep is required for human performance and alertness to recover from low levels after prolonged periods of wakefulness, it remains unclear whether they increase in a linear or asymptotic manner during sleep. It has been postulated that there is a relation between the rate of improvement in neurobehavioral functioning and rate of decline of slow-wave sleep and/or slow-wave activity (SWS/SWA) during sleep, but this has not been verified. Thus, a cross-study comparison was conducted in which dose-response curves (DRCs) were constructed for Stanford Sleepiness Scale (SSS) and Psychomotor Vigilance Task (PVT) tests taken at 1000 hours by subjects who had been allowed to sleep 0 hours, 2 hours, 5 hours or 8 hours the previous night. We found that the DRCs to each PVT metric improved in a saturating exponential manner, with recovery rates that were similar [time constant (T) approximately 2.14 hours] for all the metrics. This recovery rate was slightly faster than, though not statistically significantly different from, the reported rate of SWS/SWA decline (T approximately 2.7 hours). The DRC to the SSS improved much more slowly than psychomotor vigilance, so that it could be fit equally well by a linear function (slope = -0.26) or a saturating exponential function (T = 9.09 hours). We conclude that although SWS/SWA, subjective alertness, and a wide variety of psychomotor vigilance metrics may all change asymptotically during sleep, it remains to be determined whether the underlying physiologic processes governing their expression are different.

Non-NASA Center↗