Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load profile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Atmospheric Boundary Layer-Wind Farm Interactions Field Campaign Report

The American WAKE ExperimeNt (AWAKEN) was a field campaign in northern Oklahoma intended to analyze the potential influence of wind farms and their collective wakes on the atmospheric boundary layer (ABL), wind power production, and turbine structural loads. This report summarizes the deployment of instruments by the University of Oklahoma (OU), National Atmospheric and Atmospheric Administration National Severe Storms Laboratory (NOAA NSSL), and Lawrence Livermore National Laboratory (LLNL) during AWAKEN. Two Collaborative Lower Atmosphere Profiling Systems (CLAMPS) and LLNL ZephIR profiling lidars were co-deployed from October 3, 2022, to December 20, 2022 (winter campaign). At the end of the winter campaign, both ZephIR lidars were moved to different AWAKEN sites to be a part of a targeted wake study at the King Plains wind farm. The two CLAMPS were redeployed for a second observation period from July 1st, 2023, to September 28, 2023 (summer campaign; the ZephIR lidars were not co-located with CLAMPS).

54 ENVIRONMENTAL SCIENCES↗

Intrabasin Comparison of Produced Fluid From Hydraulically Fractured Wells in the Permian Region

The Permian Basin is the highest producing oil and gas reservoir in the United States. Hydrocarbon extraction methods in this region are often associated with frac hits, or interwell communication events where an established well is affected by the pumping of fracture fluid into a new well. Our previous work revealed a unique geochemical signal indicating the presence of frac hits in the Permian Basin. We returned to this area with the overall goal of expanding our understanding of the microbial and geochemical dynamics common in this region. To do so, we collected produced water from 25 unique sites across the Permian Basin, 10 of which had previously been characterized during an active frac hit with the rest being novel. For each sample, we measured the pH, alkalinity, geochemical composition, microbial load (qPCR), and microbial community composition (16S rRNA sequencing). Permian Basin produced water is characterized by higher sulfate and lower total dissolved solids (TDS) concentrations compared to other regions. Interestingly, wells impacted by frac hits have a geochemical profile that resembles that of fracture fluid, with both lowered sulfate and lowered TDS concentrations compared to unaffected wells in this region. Due to the year-long recovery window between sample collection periods, we anticipate that all of our data will be characterized by the typical high sulfate, low TDS concentrations.

environmental microbiology↗

Measurements of the imploding plasma sheath in triple-nozzle gas-puff z pinches

Gas-puff z-pinch implosions are characterized by the formation of a dense annular plasma shell, the sheath, that is driven to the axis by magnetic forces and therefore subject to the magneto-Rayleigh–Taylor instability. Here, the conditions within these sheaths are measured on the 1-MA COBRA generator at Cornell University for various gas species and initial fill densities. The gas-puff loads are initialized by a 7 cm diameter triple-nozzle gas valve assembly with concentric outer and inner annular nozzles and a central gas jet. Thomson scattering and laser interferometry provide spatially resolved flow, temperature, and electron density profiles midway through the implosion, while extreme ultraviolet pinhole cameras record the evolution of the plasma column and photoconducting diodes measure x-ray emission. Analysis of the scattering spectra includes a means of discriminating between thermal and non-thermal broadening to test for the presence of hydrodynamic turbulence. Two types of sheath profiles are observed, those with sharp discontinuities at the leading edge and those with smooth gradients. In both cases, non-thermal broadening is generally peaked at the front of the sheath and exhibits a characteristic decay length that roughly scales with the sheath ion mean free path. Here, we demonstrate that this non-thermal broadening term is inconsistent with laminar velocity gradients and is more consistent with dissipative turbulence driven by unstable plasma waves in a collisionless shock. The resulting differences in sheath profile are then set by the sheath ion collisionality in a manner consistent with recent 1D kinetic simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulation of plasma and neutral transport in PISCES-RF using SOLPS-ITER

In this research, the fluid plasma transport code SOLPS-ITER is applied and validated against experimental data from the plasma interaction surface component experimental station (PISCES)-RF linear plasma device to establish a physics basis for plasma and neutral transport in its two magnetic field (B-field) geometry setups-(1)the cusp and (2) non-cusp or linear B-field. The main focus of this study is to understand (1) radial plasma transport (2) heat and particle loads on the upstream dump and downstream target plate, and (3) the physics of plasma-neutral interactions in PISCES-RF. The simulation setup adheres to typical PISCES-RF experimental conditions, with a 2D helicon power deposition profile as an input heating source. SOLPS-ITER simulations reproduce experimental conditions with the Bohm diffusion model for both B-field configurations of the PISCES-RF experiment. Major energy loss channels include neutral radiation and power deposited on the wall and dump plate, with only 1% of the input power reaching the target. The ionization front is well confined near the dump plate due to the heating and puffing regions. Additionally, SOLPS-ITER simulation results are also found to be in very good agreement with the particle-in-cell calculations using the code-PICOS++ which supports the validity of SOLPS in low collisionality regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modulating thermal load through lightweight residential building walls using thermal energy storage and controlled precooling strategy

Precooling is a recognized technique for reducing cooling energy in buildings during peak hours by shifting load to off-peak hours. This technique is particularly effective in buildings with high thermal mass, because of their large thermal energy storage capacity, and in commercial buildings due to their variable electricity pricing based on time-of-use rates. Precooling in residential buildings has been a matter of limited interest in the past because of their low thermal mass and typically uniform electricity pricing rate. While previous studies on precooling primarily focused on cost savings, an important aspect of precooling is the thermal load modulation, which could be very effective in managing peak demand in lightweight residential buildings integrated with thermal energy storage systems. In this study, we examine different precooling strategies to manage the heat gains in lightweight building walls integrated with phase-change materials. We create nine different precooling profiles by controlling the interior temperature, and then evaluate the influence of the precooling profiles on four key building energy performance parameters: total heat gain, peak heat gain, maximum heat gain during peak hours, and time at which peak occurs. To thoroughly understand the fundamental physics, we first consider hypothetical climates and obtain the optimal precooling strategy required to achieve maximum peak shedding and shifting while minimizing the total heat gains. We then extend the model to Baltimore, Maryland, and estimate the benefits of the optimized precooling strategy under real conditions. The optimal precooling strategy proposed in this study can shift the peak heat gain by up to 14 hours, thereby reducing the heat gain during peak period by up to 95%, at the expense of a 23% increase in the total heat gains.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupled heat and mass transfer in internally cooled silica gel-coated aluminum foam heat exchangers for dehumidification

Solid desiccant dehumidifiers offer significant potential to improve humidity control in buildings due to their ability to independently regulate latent (humidity) and sensible (temperature) loads. However, adsorption of water vapor by desiccants is an exothermic process; the resulting heat of adsorption increases both the desiccant bed temperature and the temperature of the air flowing over the bed, thereby limiting the performance of desiccant dehumidifiers. To address this problem, desiccant-coated heat exchanger prototypes were developed by coating silica gel onto aluminum foam substrates and integrated with chilled water circulation for effective removal of the heat of adsorption. Prototype heat exchangers with two different pore densities (10 and 20 pores per inch (PPI)) and two different desiccant loadings (∼10.36% and ∼17.80%) were fabricated. Experiments were conducted by varying the inlet air face velocity, chilled water inlet temperature, and chilled water flow rate to investigate the coupled heat and mass transfer characteristics of the prototype heat exchangers over a wide range of operating conditions. The underlying transport mechanisms were analyzed using transient desiccant bed temperature, outlet air temperature, and outlet humidity profiles. The results demonstrate that internal cooling significantly enhances dehumidification performance by maintaining more favorable thermodynamic conditions for water vapor adsorption. Under identical operating conditions, a 20 PPI heat exchanger coated with 25.05 g of silica gel achieved 98.98% higher cumulative water uptake and 97.75% higher moisture removal capacity than the corresponding non-cooled case after 5 min of adsorption. This substantial enhancement was further supported by a validated one-dimensional coupled heat and mass transfer model developed in the present study. To date, this is one of the first experimental studies to systematically investigate the combined effects of internal cooling, foam pore density, and desiccant loading on the performance of silica-gel-coated metal foam heat exchangers under HVAC-relevant operating conditions.

42 ENGINEERING↗

Super-X and conventional divertor configurations in MAST-U ohmic L-mode; a comparison facilitated by interpretative modelling

Measurements are presented, alongside corresponding interpretative SOLPS-ITER simulations, of the first MAST-U experiments comparing ohmically heated L-mode fuelling scans in Conventional divertor (CD) and Super-X divertor (SXD) configurations. In experiment, at comparable outer mid-plane separatrix electron density, $n_{e,\textrm{sep,OMP}}$, the maximum lower outer target heat load was found to be a factor 16 $\,\pm\,7$ lower in SXD compared to CD. In simulation, a factor 26.8 reduction was found (slightly higher than the experimental range), suggesting an additional reduction in SXD compared to the factor 9.3 expected from geometric considerations alone. According to the simulations, this additional reduction in the SXD is due to a net radial transport of the energy remaining downstream of the $T_e = 5$ eV location. This energy is carried out of the critical (highest heat load) flux tube by deuterium atoms, demonstrating the importance of a longer legged divertor which provides space for this to occur. Importantly, in both simulation and experiment, the SXD has minimal impact on the upstream n e and T e profiles. Spectral inferences of detachment front movement in SXD compare well between simulation and experiment. In regions of high magnetic field gradient, the parallel movement of the front towards the X-point becomes less sensitive to increasing $n_{e,\textrm{sep,OMP}}$, in qualitative agreement with simplified models and previous predictive simulations. Additional aspects, regarding the target ion flux rollover, upstream separatrix temperature and drift effects, are also presented and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Marine Hydrokinetic Tidal Turbine

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset is part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with other energy technologies. This dataset contains inputs and outputs from simulations of a floating marine hydrokinetic turbine over approximately half a tidal cycle (~6.6 hours). Inflow conditions were derived from field measurements in Alaska’s Cook Inlet and represent a tidal environment in which the current speed ramps from near 0 m/s to a peak of 3 m/s and back. The original acoustic doppler current profiler dataset is publicly available on the Marine and Hydrokinetic Data Repository. In a full tidal cycle, the flow reverses and the rotor would reorient; this reversal was not modeled. In the Cook Inlet campaign , turbulence intensity was similar in both directions. Two inflow cases are included. In the first case, labeled “raw” in the files, the measured current time series was used directly in the InflowWind module of OpenFAST. Speed and direction were applied as a function of time and elevation, uniformly in the horizontal direction. With full spatial coherence, this approach captures high turbulent variability and results in pronounced power fluctuations, so it is considered a conservative, near-worst-case representation of loading. In the second case, labeled “average” in the files, a 30-minute moving average was applied to extract the slowly varying mean speed. The residual fluctuations about this mean were used to generate spatially varying, full-field turbulence inputs with TurbSim, giving a more physically realistic representation of the inflow across the rotor disk. Two random realizations were used to produce distinct inflow conditions for two OpenFAST simulations representing a two-turbine array. The same turbulence intensity is applied across the full time series, producing larger fluctuations at the start and end, where the mean speed is low. The second case is the more appropriate framework for performance and power assessment but overpredicts turbulence at lower flow speeds and underpredicts it at higher speeds. As the floating platform moves and the rotor changes its x-position, Taylor’s frozen turbulence hypothesis used by InflowWind assumes a constant rather than a time-varying mean velocity, introducing some inaccuracy in the velocity plane sampling. The turbine modeled is the 500-kW Reference Model 1, a horizontal-axis two-bladed hydrokinetic turbine on a four-column floating semisubmersible substructure . Simulations were performed using OpenFAST v4.1 with the Reference Open Source Controller (ROSCO) v2.10. All input files required to reproduce the simulations are included. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel . This unit supports up to 2.5 MW, but NLR has only a single 1.25-MW stack. The datasets report hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. The system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operating current of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The simulated tidal turbine time series data was translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz. Each zip file represents a single tidal electrolysis experiment and is named: {technology}_{inflow method}_{number of 500 kW tidal turbines connected} For instance, “tidal-500kW-RM1_average_2.zip” is a 6-hour experiment using the 500-kW tidal reference model, scaled by 2x (1-MW) to better match the electrolyzer maximum of 1.25MW, fed with the 30-minute moving average current case. Each zip folder contains the following files: A .csv file of raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. A .csv file combines all tidal profiles as "combined_tidal_experiments.csv." A separate experiment, “characterization_200.zip,” shows the MC250 electrolyzer steady-state response with 30-minute load steps over 5 hours and is accessible with this entry.

08 HYDROGEN↗

Measurements and modeling of type-I and type-II ELMs heat flux to the DIII-D divertor

Type-I and type-II edge-localized-modes (ELMs) heat flux profiles measured at the DIII-D divertor feature a peak in the vicinity of the strike-point and a plateau in the scrape-off-layer (SOL), which extends to the first wall. The plateau is present in attached and detached divertors and it is found to originate with plasma bursts upstream in the SOL. The integrated ELM heat flux is distributed at ~65% in the peak and ~35% in this plateau. The parallel loss model, currently used at ITER to predict power loads to the walls, is benchmarked using these results in the primary and secondary divertors with unprecedented constraints using experimental input data for ELM size, radial velocity, energy, electron temperature and density, heat flux footprints and number of filaments. The model can reproduce the experimental near-SOL peak within ~20%, but cannot match the SOL plateau. Employing a two-component approach for the ELM radial velocity, as guided by intermittent data, the full radial heat flux profile can be well matched. The ELM-averaged radial velocity at the separatrix, which explains profile widening, increases from ~0.2 km s –1 in attached to ~0.8 km s –1 in detached scenarios, as the ELM filaments' path becomes electrically disconnected from the sheath at the target. The results presented here indicate filaments fragmentation as a possible mechanism for ELM transport to the far-SOL and provide evidence on the beneficial role of detachment to mitigate ELM flux in the divertor far-SOL. However, these findings imply that wall regions far from the strike points in future machines should be designed to withstand significant heat flux, even for small-ELM regimes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reflectometry with Polarized Neutrons on In Situ Grown Thin Films

Originating from the demand for obtaining depth-resolved magnetization profiles from thin films and heterostructures, polarized neutron reflectometry (PNR) has developed into a unique research tool, which also finds application in the analysis of superconducting or soft matter thin films. While certain in situ sample environments such as gas-loading or humidity cells were quickly realized after PNR first emerged, preparing and growing thin magnetic films directly in the neutron beam could only be realized in recent years. Herein, a dedicated insight is given on the history and development of in situ thin film growth capabilities for PNR, from early pioneering experiments to the present day. The scientific and technological challenges as well as the advances of neutron sources, neutronics, and data treatment that have led to its realization are highlighted together with the unique research opportunities that it provides and recently obtained experimental results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Shock-induced twinning/detwinning and spall failure in Cu–Ta nanolaminates at atomic scales

Here, this study provides new insights into the role of interfaces on the deformation and failure mechanisms in shock-loaded Cu–Ta–Cu trilayer system. The thickness of the Ta layer, piston velocities, and shock pulse durations were varied to explore the impact of impedance mismatch and loading conditions on spallation behavior and twin formation. It was found that the interfaces play a crucial role in the dynamic response of these multilayered systems since secondary reflection waves generated at the interfaces significantly affected the peak stress and pressure profiles, influencing void nucleation and failure modes. In the trilayer systems, failure predominantly occurred at interfaces and within the Ta layer, with void nucleation sites and twinning behavior being markedly different compared to single-crystal Cu and Ta. Increasing the Ta layer thickness modified the wave interactions, leading to different failure locations. Higher piston velocities were associated with increased spall strength by enhancing wave interactions and void formation, particularly at the interfaces and within the Ta layer, under specific configurations. Additionally, shorter shock pulse durations facilitated earlier initiation of the release fan, reducing twin formation and altering the failure dynamics by accelerating twin annihilation and pressure release.

36 MATERIALS SCIENCE↗

Mitigation of magneto-Rayleigh-Taylor instability growth in a triple-nozzle, neutron-producing gas-puff Z pinch

The gas-puff Z-pinch is a well-known source of x-rays and/or neutrons, but it is highly susceptible to the magneto-Rayleigh-Taylor instability (MRTI). Approaches to MRTI mitigation include density profile tailoring, in which nozzles are added or modified to alter the acceleration trajectory, and axial pre-magnetization, in which perturbations are smoothed out via magnetic field line tension. In this work, we present two-dimensional magnetohydrodynamic simulations of loads driven by an 850 kA,160 ns driver that suggest these mitigation strategies can be additive. The initial axial magnetic field, B z0 , to stabilize a 2.5-cm-radius Ne gas liner imploding onto an on-axis deuterium target can be reduced from 0.7 T to 0.3 T by adding a second liner with a radius of 1.25 cm. Because MRTI mitigation tends to increasingly lower yield with higher B z0 , the use of a lower field is advantageous. Here, we predict a reduction in yield penalty from > 100× with the single liner to < 10× with a double liner. A premagnetized, triple nozzle gas puff could therefore be an attractive source for intense neutrons or other fusion applications.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Label-Free Profiling of up to 200 Single-Cell Proteomes per Day Using a Dual-Column Nanoflow Liquid Chromatography Platform

Single-cell proteomics (SCP) has great potential to advance biomedical research and personalized medicine. The sensitivity of such measurements increases with low-flow separations (<100 nL/min) due to improved ionization efficiency, but the time required for sample loading, column washing, and regeneration in these systems can lead to low measurement throughput and inefficient utilization of the mass spectrometer. Herein, we developed a two-column liquid chromatography (LC) system that dramatically increases the throughput of label-free SCP using two parallel subsystems to multiplex sample loading, online desalting, analysis, and column regeneration. The integration of MS1-based feature matching increased proteome coverage when short LC gradients were used. The high-throughput LC system was reproducible between the columns, with a 4% difference in median peptide abundance and a median CV of 18% across 100 replicate analyses of a single-cell-sized peptide standard. An average of 621, 774, 952, and 1622 protein groups were identified with total analysis times of 7, 10, 15, and 30 min, corresponding to a measurement throughput of 206, 144, 96, and 48 samples per day, respectively. When applied to single HeLa cells, we identified nearly 1000 protein groups per cell using 30 min cycles and 660 protein groups per cell for 15 min cycles. Finally, we explored the possibility of measuring cancer therapeutic targets with a pilot study comparing the K562 and Jurkat leukemia cell lines. This work demonstrates the feasibility of high-throughput label-free single-cell proteomics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lithiation Gradients and Tortuosity Factors in Thick NMC111-Argyrodite Solid-State Cathodes

Achieving high energy density in all-solid-state lithium batteries will require the design of thick cathodes, and these will need to operate reversibly under normal use conditions. We use high-energy depth-profiling X-ray diffraction to measure the localized lithium content of Li 1-x Ni 1/3 Mn 1/3 Co 1/3 O 2 (NMC111) through the thickness of 110 μm thick composite cathodes. The composite cathodes consisted of NMC111 of varying mass loadings mixed with argyrodite solid electrolyte Li 6 PS 5 Cl (LPSC). During cycling at C/10, substantial lithiation gradients developed, and varying the NMC111 loading altered the nature of these gradients. Microstructural analysis and cathode modeling showed this was due to high tortuosities in the cathodes. This was particularly true in the solid electrolyte phase, which experienced a marked increase in tortuosity factor during the initial charge. Our results demonstrate that current distributions are observed in sulfide-based composites and that these will be an important consideration for practical design of all-solid-state batteries.

25 ENERGY STORAGE↗

3D modeling of n = 1 RMP driven heat fluxes on the SPARC tokamak PFCs using HEAT

3D heat flux calculations at the lower outer divertor plate of SPARC using the HEAT code show that 3D fields generated from error field correction coils can lead to enhanced peak heat fluxes up to 15 times larger compared to the axisymmetric case. Previously employed to simulate axisymmetric heat flux on 3D plasma facing components, the HEAT code can now predict 3D heat flux generated by non-axisymmetric plasmas. This is achieved via a new HEAT module which leverages the 3D field line tracing capabilities of MAFOT starting from an M3D-C1 (MHD resistive code) perturbed equilibria. The resulting heat flux is assigned using the magnetic footprint and the heat flux layer model, an extension of the 2D heat flux model also known as the Eich, to 3D non-axisymmetric plasmas. For SPARC, the new capabilities of HEAT are used to calculate the 3D heat loads resulting from n = 1 perturbation fields (with n indicating the toroidal periodicity) applied through a toroidal array of six picture frame coils with different amplitude. The comparison with the unperturbed case shows significant changes in shape and intensity of the heat flux profile. The results show that the application of n = 1 3D field leads to a localized enhancement of the heat flux peak, influenced by the wetted area impacted by the magnetic footprint, and the appearance of a secondary heat flux peak, whose intensity depends on amplitude of the applied 3D field and toroidal location.

3D heat flux↗

Multi-facility analysis using metered power data to quantify MRI energy use and utility bill costs across scanner operating modes

This study quantifies the energy consumption of magnetic resonance imaging (MRI) scanners across discrete operating modes during routine clinical workflows, based solely on electrical power measurements. Although previous studies have investigated MRI energy consumption within single hospitals or specific clinical settings, this research provides a broader and more systematic analysis. Researchers analyzed electrical power data and applied a previously developed semi-automatic method for identifying MRI operating modes using load duration curves for 20 MRI scanners across four different U.S. healthcare facilities, encompassing outpatient, inpatient, and mixed-use clinical settings. A key innovation is the inclusion of localized hourly utility rates to estimate costs, a parameter absent in prior literature. Key findings indicate significant variability in energy and cost profiles between weekdays and weekends. Scanner characteristics, including magnet strength, manufacturer, vintage, location, and clinical setting, influenced average daily energy consumption and power thresholds for operating modes. Notably, the clinical setting of a scanner predominantly determines its energy use. For example, the scanners in outpatient facilities consumed more energy. The breakdown of energy usage and costs by operating modes showed scanners spend between 61% and 93% of their time in nonproductive modes, with one outlier spending 34%. Average daily energy use for the scanners in the study ranged from 160 to 1069 kWh, with energy costs ranging from $\$$9 to $\$$149. This study uses an existing framework to quantify MRI energy behavior, leading to insights that can enable improved performance and cost savings across different healthcare environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Clustering Interval Load with Weather to Create Scenarios of Behind-the-Meter Solar Penetration

Forecasting load at the feeder level has become increasingly challenging with the penetration of behind-the-meter solar, as this self-generation is only visible to the utility as aggregated net-load. This work proposes a methodology for creation of scenarios of solar penetration at the feeder level for use by forecasters to test the robustness of their algorithm to progressively higher penetrations of solar. The algorithm draws on publicly available observations of weather condition (e.g., rainy/cloudy/fair) for use as proxies to sky clearness. These observations are used to mask and weight the interval deviations of similar native usage profiles from which average interval usage is calculated and subsequently added to interval net generation to reconstruct interval total generation. This approach improves the estimate of annual energy generation by 23%; where the net generation signal currently reflects 52% of total annual gener- ation, now 75% is captured. This methodology for creation of forecast testing scenarios is data driven and extensible to service territories which lack information on irradiance measurements and geocoordinates.

solar, load↗