Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Identifying Common Use Cases across Extensible Traffic Management (xTM) for Interactions with Air Traffic Controllers

NASA’s Extensible Traffic Management (xTM) builds on the foundation and the architecture of Unmanned Aircraft Systems (UAS) Traffic Management (UTM) concept and extends it broadly to other domains, such as Advanced / Urban Air Mobility (AAM/UAM) and Upper Class E Traffic Management (ETM). These xTM concepts assume the ability to fly in airspace that is authorized to operate solely under xTM services and mostly without any air traffic control (ATC) support. However, they also assume circumstances in which the xTM vehicles would need to operate in conventional ATC-managed airspace, both during nominal and off-nominal scenarios. Due to the vast differences in the xTM vehicle performances and missions, there is a concern that ATC may have difficulty in safely managing the xTM traffic and providing appropriate services to all vehicles, unless a consistent set of roles, procedures, and data exchange requirements are defined across the diverse set of xTM vehicle operations. In this paper, we describe a set of use cases that have been identified in UTM, AAM/UAM, and ETM operations that are related to ATC interactions, and we propose to categorize these use cases across xTM domains based on common trigger events. Organizing the use cases from the perspective of ATC roles per each trigger event is expected to provide the first step in discovering common procedures and data requirements across xTM domains that could help ease the controllers’ cognitive task load and allow them to manage these interactions more safely.

Extensible Traffic Management (xTM)↗

Calibration of urban building energy model using smart meter data for district peak load prediction

Urban building energy modeling (UBEM) is a powerful approach to assessing baseline building energy performance and retrofits with new technologies across building stocks in cities. However, the accuracy of UBEM is often constrained by the limited availability of reliable data about building characteristics and operations, such as envelope efficiency levels, HVAC system performance, and end-use load patterns. Existing research has performed UBEM calibration using annual or monthly energy consumption data, which falls short when higher-resolution time series applications are needed, such as peak load prediction for utility operation planning. This study presents a new framework for calibrating building energy models at urban scale using smart meter data, targeting the accurate prediction of summer peak electricity loads to support robust grid planning. The framework first integrates various data sources to enhance baseline input assumptions for building models, and then calibrates the baseline models through a pattern-matching approach. A case study using CityBES and two years of AMI data from over 9000 residential customers in Portland, Oregon, demonstrated the workflow and its effectiveness. The calibrated models achieved a daily peak load mean absolute percentage error of 2.6 % during the heatwave in the calibration year, and 2.0 % in the validation year using another year of AMI data. Using the calibrated models, we analyzed the demand flexibility potential of the district building stock as an application of UBEM calibration. The findings affirm the appropriate use of UBEM for peak electric load forecasting and demand side management at the utility distribution system level.

AMI data↗

ARPA-E PERFORM datasets

Time-coincident load, wind, and solar data including actual and probabilistic forecast datasets at 5-min resolution for ERCOT, MISO, NYISO, and SPP. Wind and solar profiles are supplied for existing sites as well as planned sites based on interconnection queue projects as of 2021. For ERCOT actuals are provided for 2017 and 2018 and forecasts for 2018, and for the remaining ISOs actuals are provided for 2018 and 2019 and forecasts for 2019. There datasets were produced by NREL as part of the ARPA-E PERFORM project, an ARPA-E funded program that aim to use time-coincident power and load seeks to develop innovative management systems that represent the relative delivery risk of each asset and balance the collective risk of all assets across the grid. For more information on the datasets and methods used to generate them see https://github.com/PERFORM-Forecasts/documentation.

5-min data↗

Selecting a Control Strategy for Plug and Process Loads

Plug and Process Loads (PPLs) are building loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the building occupants. PPLs in commercial buildings account for almost 5% of U.S. primary energy consumption. On an individual building level, they account for approximately 25% of the total electrical load in a minimally code-compliant commercial building, and can exceed 50% in an ultra-high efficiency building such as the National Renewable Energy Laboratory's (NREL) Research Support Facility (RSF) (Lobato et al. 2010). Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. A complex array of technologies that measure and manage PPLs has emerged in the marketplace. Some fall short of manufacturer performance claims, however. NREL has been actively engaged in developing an evaluation and selection process for PPLs control, and is using this process to evaluate a range of technologies for active PPLs management that will cap RSF plug loads. Using a control strategy to match plug load use to users' required job functions is a huge untapped potential for energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Best Practices for Smart Grid-Interactive Efficient Building Ready Performance Contracts

Grid-interactive efficient building (GEB) measures reduce costs and optimize energy use for additional grid services by coordinating building energy loads and providing continuous demand management. Incorporating GEB energy conservation measures (ECMs) in performance contracts is reliant upon multiple factors. These factors include site selection with utility tariffs and incentives favorable to GEB, the identification of GEB as a priority in the initial stages of the contracting process, integration of GEB within comprehensive performance contracts with multiple other ECMs, and careful consideration of GEB measurement and verification (M&V) for energy savings performance contracts (ESPCs) and performance assurance for utility energy service contracts (UESCs).

building energy loads↗

Roadmap and Benchmarking: Privacy in Federated Load Forecasting

Data-driven techniques for energy demand forecasting continue to emerge with promising impacts on distribution grid planning. However, the development of robust and generalizable machine learning models requires that representative high quality training data are available. Distributed energy resources have begun to embed intelligence, gathering large amounts of data on customer demand, behavior, and household devices that are connected to the grid. Though utilities aggregate meter-level demand data for load shaping, demand response, outage management, reliability planning, and billing applications, there lies an inherent privacy concern in sharing consumption data that may identify individual consumer behavioral patterns. Hence, while sharing the data is crucial, the private sensitive customer data must be safeguarded from being exposed or manipulated. In this study, we propose a roadmap for implementing a based privacy preserving framework to support the advancement of data-driven analytics in data-sensitive distributed energy resources environments. The roadmap incorporates federated learning–a distributed training framework, differential privacy–a statistical framework that provides guarantees to safeguard the leakage of sensitive data, secure multiparty computation and homomorphic encryption– techniques for encrypting model gradients and applying secure aggregation on the server. Moreover, we perform baseline experiments on the federated short-term load forecasting (STLF) task using open-source residential load profile datasets, offering insights into the challenges of integrating differential privacy into federated learning.

Abebe, Waqwoya [Oak Ridge National Laboratory (ORN↗

Time-varying value of electric energy efficiency

Electric energy efficiency resources save energy and may reduce peak demand. Historically, quantification of energy efficiency benefits has largely focused on the economic value of energy savings during the first year and lifetime of the installed measures. Due in part to the lack of publicly available research on end-use load shapes (i.e., the hourly or seasonal timing of electricity savings) and energy savings shapes, consideration of the impact of energy efficiency on peak demand reduction (i.e., capacity savings) has been more limited. End-use load research and the hourly valuation of efficiency savings are used for a variety of electricity planning functions, including load forecasting, demand-side management and evaluation, capacity and demand response planning, long-term resource planning, renewable energy integration, assessing potential grid modernization investments, establishing rates and pricing, and customer service. This study reviews existing literature on the time-varying value of energy efficiency savings, provides examples in four geographically diverse locations of how consideration of the time-varying value of efficiency savings impacts the calculation of power system benefits, and identifies future research needs to enhance the consideration of the time-varying value of energy efficiency in cost-effectiveness screening analysis. Findings from this study include: -The time-varying value of individual energy efficiency measures varies across the locations studied because of the physical and operational characteristics of the individual utility system (e.g., summer or winter peaking, load factor, reserve margin) as well as the time periods during which savings from measures occur. -Across the four locations studied, some of the largest capacity benefits from energy efficiency are derived from the deferral of transmission and distribution system infrastructure upgrades. However, the deferred cost of such upgrades also exhibited the greatest range in value of all the components of avoided costs across the locations studied. -Of the five energy efficiency measures studied, those targeting residential air conditioning in summer-peaking electric systems have the most significant added value when the total time-varying value is considered. -The increased use of rooftop solar systems, storage, and demand response, and the addition of electric vehicles and other major new electricity-consuming end uses are anticipated to significantly alter the load shape of many utility systems in the future. Data used to estimate the impact of energy efficiency measures on electric system peak demands will need to be updated periodically to accurately reflect the value of savings as system load shapes change. -Publicly available components of electric system costs avoided through energy efficiency are not uniform across states and utilities. Inclusion or exclusion of these components and differences in their value affect estimates of the time-varying value of energy efficiency. -Publicly available data on end-use load and energy savings shapes are limited, are concentrated regionally, and should be expanded.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Communication and Control for Distributed Energy Resource Integration: Phase 2 Scientific Report

The objective of this research project is to demonstrate sensing, communication, information and control technologies to achieve a seamless integration of multivendor distributed energy resource (DER) units at aggregation levels that meet individual user requirements for facility operations (residential, commercial, industrial, manufacturing, etc.) and further serve as resource options for electric and natural gas utilities. The fully demonstrated DER aggregation system with embodiment of communication and control technologies will lead to real-time, interactive, customer-managed service networks to achieve greater customer value. Work on this Advanced Communication and Control Project (ACCP) consists of a two-phase approach for an integrated demonstration of communication and control technologies to achieve a seamless integration of DER units to reach progressive levels of aggregated power output. Phase I involved design and proof-of-design, and Phase II involves real-world demonstration of the Phase I design architecture. The scope of work for Phase II of this ACCP involves demonstrating the Phase I design architecture in large scale real-world settings while integrating with the operations of one or more electricity supplier feeder lines. The communication and control architectures for integrated demonstration shall encompass combinations of software and hardware components, including: sensors, data acquisition and communication systems, remote monitoring systems, metering (interval revenue, real-time), local and wide area networks, Web-based systems, smart controls, energy management/information systems with control and automation of building energy loads, and demand-response management with integration of real-time market pricing. For Phase II, BPL Global shall demonstrate the Phase I design for integrating and controlling the operation of more than 10 DER units, dispersed at various locations in one or more Independent System Operator (ISO) Control Areas, at an aggregated scale of more than 1 MW, to provide grid support. Actual performance data with respect to each specified function above is to be collected during the Phase II field demonstration. At a minimum, the Phase II demonstration shall span one year of field operations. The demonstration performance will need to be validated by the target customer(s) for acceptance and subsequent implementation. An ISO must be involved in demonstration planning and execution. As part of the Phase II work, BPL Global shall develop a roadmap to commercialization that identifies and quantifies the potential markets for the integrated, aggregated DER systems and for the communication and control technologies demonstrated in Phase I. In addition, the roadmap must identify strategies and actions, as well as the regional and national markets where the aggregated DER systems with communication and control solutions will be introduced, along with a timeline projected for introduction into each identified market. In Phase I of this project, we developed a proof-of-concept ACCP system and architecture and began to test its functionality at real-world sites. These sites had just over 10 MW of DERs and allowed us to identify what needed to be done to commercialize this concept. As a result, we started Phase II by looking at our existing platform and identified its strengths and weaknesses as well as how it would need to evolve for commercialization. During this process, we worked with different stakeholders in the market including: Independent System Operators, DER owners and operators, and electric utility companies to fully understand the issues from all of the different perspectives. Once we had an understanding of the commercialized ACCP system, we began to document and prepare detailed designs of the different system components. The components of the system with the most significant design improvements were: the on-site remote terminal unit, the communication technology between the remote site and the data center, and the scalability and reliability of the data center application. As we began to implement the Phase II ACCP system, we upgraded the real-world demonstration sites from Phase I of the project as well as added additional sites to broaden the types of DER the platform was tested with. We worked with the owners and operators of these sites to understand how the system was meeting their needs and made modifications throughout the project as needed. This also included an effort to continue to understand the barriers to commercial adoption of the ACCP architecture and standardized communication protocols. The final aspect of this phase of the project was to prepare resources to aid in the commercial adoption of the ACCP architecture and standardized communication protocols. This entailed: presentations at conferences, published articles and papers, and web-based technical resources to provide tools to aid in the design and implementation of ACCP systems.

03 NATURAL GAS↗

Net-Zero Carbon Microgrids

The microgrid concept has been effective in creating aggregations of distributed energy resources—generation, storage and loads—for resiliency, in the form of energy security. The success of microgrids in bringing energy security to a wide range of customers—from individual residences to commercial and industrial installations to military bases—has been exemplified during power disruptions and extended outages due to extreme weather events, cybersecurity attacks, and equipment failures. Now microgrids have an opportunity to meet the challenges of climate change and contribute to a carbon-free power delivery system. The transition to net-zero starts within microgrids themselves. In fact, today’s microgrids are largely dominated by generators using fossil fuels, natural gas and diesel, with high greenhouse gas emissions. In short, the transition to net-zero means replacing fossil fueled generators with renewable generation in microgrids. This transition is extended by including new dispatchable generation technologies that are 100% carbon-free and that offer additional advantage of a more-dependable and sustainable source of energy and power. Basically, the decarbonization of microgrids requires three elements: 1) maximizing generation from renewable energy resources, 2) management of storage and flexible loads to balance the variability and intermittency of renewable energy resources, and 3) introducing new clean power sources, including hydrogen-based generation and small modular reactors. This report affirms a need for specific focus by governmental agencies at national, regional, and local levels to establish technology, policy, and investment in this area. The intention of the Net-Zero Microgrid (NZM) Program is to inform these constituencies with cross-cutting research and tools for the reduction of GHG in microgrids – to net-zero in the near term eventually to zero in the longer term. The NZM Program is committed to achieving decarbonization for resiliency and for providing clean energy at the local or distribution level, from remote communities to underserved communities, and large industrial and military facilities. The NZM Planning and Design Platform is a core tool to be developed as an early deliverable of the NZM Program because only a fully integrated microgrid-design approach will ensure maximum carbon reduction in energy production.

13 HYDRO ENERGY↗

Real-Time Testbed for Smart Grid Recloser Controller

The growing need for a low voltage recloser has become apparent due to the rise in requirements for a smart grid. This includes more detailed management of power flow forward (towards load) and backward (towards generation), source synchronization in real time, more indepth fault responses, and the use of green energy. The SEL-651R-2 relay is a device that can manage these needs, especially in fault response and synchronization, and is commonly used in systems called microgrids. Microgrids are distribution level systems that are able to operate separated from the main grid, are typically installed much closer to the load(s), and are fed by distributed energy resources (DERs), such as wind, solar or diesel generators. The SEL-651R-2 is normally used in the field with presets operative settings, but the Western Michigan University (WMU) Center for Interdisciplinary Research on Secure, Efficient and Sustainable Energy Technology (WMU InterEnergy Center) wished to test this device in its range of capabilities for microgrid application. A Hardware-In-the-Loop (HIL) testbed was implemented and used through the Real Time Digital Simulator (RTDS) using the RSCAD software to test the SEL-651R-2's use cases and functions. The testbed includes a microgrid with interconnection to a larger main grid, and the relay is meant to control the recloser at the point of common coupling (PCC) between the main grid and microgrid. The testbed shows how basic protections, reclosing, and synchronization checks function when handling faults that affect both the microgrid and the main grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Climate Control Load Reduction Strategies for Electric Drive Vehicles in Cold Weather

When operated, the climate control system is the largest auxiliary load on a vehicle. This load has significant impact on fuel economy for conventional and hybrid vehicles, and it drastically reduces the driving range of all electric vehicles (EVs). Heating is even more detrimental to EV range than cooling because no engine waste heat is available. Reducing the thermal loads on the heating, ventilating, and air conditioning system will extend driving range and increase the market penetration of EVs. Researchers at the National Renewable Energy Laboratory have evaluated strategies for vehicle climate control load reduction with special attention toward grid connected electric vehicles. Outdoor vehicle thermal testing and computational modeling were used to assess potential strategies for improved thermal management and to evaluate the effectiveness of thermal load reduction technologies. A human physiology model was also used to evaluate the impact on occupant thermal comfort. Experimental evaluations of zonal heating strategies demonstrated a 5.5% to 28.5% reduction in cabin heating energy over a 20-minute warm-up. Vehicle simulations over various drive cycles show a 6.9% to 18.7% improvement in EV range over baseline heating using the most promising zonal heating strategy investigated. A national-level analysis was conducted to determine the overall national impact. If all vehicles used the best zonal strategy, the range would be improved by 7.1% over the baseline heating range. This is a 33% reduction in the range penalty for heating.

30 DIRECT ENERGY CONVERSION↗

Developing Mars-Based Clinical Scenarios for an Earth Independent Medical Operations (EIMO) – Based Decision Support Service

As crewed missions move beyond Low-Earth Orbit, pre-mission planning cannot fully buy down the medical risks of exploration-class missions. Martian missions, where increased hazards exist, (such as long-duration spaceflight, surface-level EVA operations, and communications delays) will require a paradigm shift in the structure of a medical system. An Earth-Independent Medical Operations-based Medical System (EIMO-MS) will need to optimize four critical domains to help provide medical care: utilization of Pre-Mission Planning, augmentation of Acute and Prolonged Medical Decision Making, automated tracking of Resource Management, and assistance in Task Load Balance. The ideal EIMO-MS will be able to accomplish this goal by having an interactive, adaptable interface that will be able to provide real-time medical services. It must respond based on the level of crewmember training, medical situation, and available medical and non-medical resources. To showcase the capabilities and requirements of such a sophisticated automated MS, a series of clinical scenarios of escalating complexity were developed with clinical and systems engineering input. These scenarios describe in clinical detail what a theoretical future medical system, enhanced with multiple information streams (such as a medical database, an AI-based Decision Support System, real-time monitoring, enhanced in-situ laboratory imaging, etc.) can achieve in conjunction with a trained and experienced crew. Scenarios are comprised of: a context section including objectives and applicable spaceflight environment, a highlighted assumptions section, a clinical narrative section, and a systems engineering activity diagram demonstrating the integrated Medical System (MS). The “swim lanes” of the activity diagram act as the logistical core of each scenario and show how the MS will interact with the crew, ground support, and other in-flight systems. The Design Reference Mission that is used for the scenarios is based on existing reference mission profiles [1] with a projected 30-sol stay on the Martian surface. Scenarios span the spectrum from planned evaluations, minor medical care, urgent care, surgical guidance, critical and expectant management, and behavioral health care. Mission complexity will exponentially increase during deep space and Mars exploration-class missions, and medical support for these missions will likewise need to increase in autonomy and adaptability. The integrated system that will support these missions will need to provide assistance in a variety of anticipated and unforeseen scenarios. These medical scenarios, guided by clinician input, are initial steps in crafting the requirements for an EIMO-based medical system. By working in a systems engineering framework, requirements and capabilities can be extracted and mapped while maintaining a clinical core.

Prashant Parmar↗

Solar array switching power management

Solar array power switching concepts are explored for a 250 kWe manned LEO platform, a 50-250 kWe load for an orbit transfer vehicle (OTV), and an unmanned platform with a 50 kWe load in GEO. A solar array switching power management (SASPM) system is under study to satisfy the switching demands. Direct connections to arrays would be implemented for voltage regulations, power distribution, and the capability of reconfiguring the arrays to meet requirements. Mission characteristics that would require the power sources were explored. The LEO platform was projected to use a concentrator, have no reconfigurability, use 250 NiH2 batteries, supply 80-0 Vdc to an ion drive, and have a 20-30 yr life. Both GEO and OTV arrays were planar, would feature reconfigurability, and supply 800 Vdc to an ion drive. NiH2 batteries would be on the OTV, while the GEO spacecraft would use AgH2 cells. A block diagram of the basic switching configuration is presented.

Cassinelli, J. E.↗

A phase model approach for thermostatically controlled load demand response

A significant portion of electricity consumed worldwide is used to power thermostatically controlled loads (TCLs) such as air conditioners, refrigerators, and water heaters. Because the short-term timing of operation of such systems is inconsequential as long as their long-run average power consumption is maintained, they are increasingly used in demand response (DR) programs to balance supply and demand on the power grid. Here, we present an ab initio phase model for general TCLs, and use the concept to develop a continuous oscillator model of a TCL and compute its phase response to changes in temperature and applied power. This yields a simple control system model that can be used to evaluate control policies for modulating the power consumption of aggregated loads with parameter heterogeneity and stochastic drift. We demonstrate this concept by comparing simulations of ensembles of heterogeneous loads using the continuous state model and an established hybrid state model. The developed phase model approach is a novel means of evaluating DR provision using TCLs, and is instrumental in estimating the capacity of ancillary services or DR on different time scales. We further propose a novel phase response based open-loop control policy that effectively modulates the aggregate power of a heterogeneous TCL population while maintaining load diversity and minimizing power overshoots. This is demonstrated by low-error tracking of a regulation signal by filtering it into frequency bands and using TCL sub-ensembles with duty cycles in corresponding ranges. As a result, control policies that can maintain a uniform distribution of power consumption by aggregated heterogeneous loads will enable distribution system management (DSM) approaches that maintain stability as well as power quality, and further allow more integration of renewable energy sources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An accelerated approach to inline non-LTE modeling

A goal across many physics and engineering disciplines is to use radiation-hydrodynamics codes to accurately simulate systems that are expected to deviate from local thermodynamic equilibrium (LTE), such as laser-driven hohlraums, stellar coronae, and supernova ejecta. The computational expense of traditional non-LTE (NLTE) opacity calculations can dominate the cost of simulating these systems and render NLTE physics untenable in most cases. In this paper, we present a new parallel implementation for NLTE opacity calculations that employs advanced load balancing, vectorization, and memory management to significantly reduce the computational costs of these calculations. Using the radiation-hydrodynamics code xRAGE , we demonstrate this new implementation on three test problems and present order-of-magnitude speed improvements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Three-Dimensional Electromagnetic and Structural Analysis of Disruptions in the COMPASS Upgrade Vacuum Vessel

Structural analyses of disruptions and the electromagnetic (EM) analyses to support them typically use symmetry to produce a manageable model size. Nonaxisymmetric halo loads require larger analysis models. Here, in this paper, the results of transient EM analyses of halo strikes during a vertical displacement event are presented. The plasma motions and halo characteristics are prescribed based on analyses performed by the Institute of Plasma Physics of the Czech Republic. The time transient EM solution provides loads to a full three-dimensional transient dynamic analysis of the vacuum vessel. The responses to large lateral halo loads are altered and mitigated by the mode responses of the vessel. Dynamic load factors are computed for specific locations in the vessel and supports.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

AMRZone: A Runtime AMR Data Sharing Framework For Scientific Applications

Frameworks that facilitate runtime data sharing across multiple applications are of great importance for scientific data analytics. Although existing frameworks work well over uniform mesh data, they can not effectively handle adaptive mesh refinement (AMR) data. Among the challenges to construct an AMR-capable framework include: (1) designing an architecture that facilitates online AMR data management; (2) achieving a load-balanced AMR data distribution for the data staging space at runtime; and (3) building an effective online index to support the unique spatial data retrieval requirements for AMR data. Towards addressing these challenges to support runtime AMR data sharing across scientific applications, we present the AMRZone framework. Experiments over real-world AMR datasets demonstrate AMRZone's effectiveness at achieving a balanced workload distribution, reading/writing large-scale datasets with thousands of parallel processes, and satisfying queries with spatial constraints. Moreover, AMRZone's performance and scalability are even comparable with existing state-of-the-art work when tested over uniform mesh data with up to 16384 cores; in the best case, our framework achieves a 46% performance improvement.

Zhang, Wenzhao↗

Supercritical CO 2 recompression Brayton cycle: completed assembly description

Through multi-year funding from DOE-NE, Sandia National Labs supercritical carbon dioxide (SCO 2 ) closed Brayton cycle (CBC) research and development team have recently overseen the completion of the SCO 2 CBC recompression test assembly (TA), and delivery from the development contractor’s facility to Sandia, Albuquerque. The primary components of the completed TA include two turbo alternator-compressors and associated motor/controllers, three printed circuit heat exchangers, and six shell-and-tube heaters and associated controllers. Principal supporting components include a cooling tower, electricity-dissipating load bank, and leakage flow management equipment. With this milestone completed, significant increase in CBC R&D is anticipated with the objective of advancing the technology readiness level of components seen by industry as immature. This report presents detailed descriptions of all components and operating software necessary to operate the recompression CBC.

Pasch, James Jay↗