Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “limiting techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Design Space Issues for Intrinsic Evolvable Hardware

This paper discusses the problem of increased programming time for intrinsic evolvable hardware (EM) as the complexity of the circuit grows. As the circuit becomes more complex, then more components will be required and a longer programming string, L, is required. We develop equations for the size of the population, n, and the number of generations required for the population to converge, based on L. Our analytical results show that even though the design search space grows as 2L (assuming a binary programming string), the number of circuit evaluations, n*ngen, only grows as O(Lg3), or slightly less than O(L). This makes evolvable techniques a good tool for exploring large design spaces. The major hurdle for intrinsic EHW is evaluation time for each possible circuit. The evaluation time involves downloading the bit string to the device, updating the device configuration, measuring the output and then transferring the output data to the control processor. Each of these steps must be done for each member of the population. The processing time of the computer becomes negligible since the selection/crossover/mutation steps are only done once per generation. Evaluation time presently limits intrinsic evolvable hardware techniques to designing only small or medium-sized circuits. To evolve large or complicated circuits, several researchers have proposed using hierarchical design or reuse techniques where submodules are combined together to form complex circuits. However, these practical approaches limit the search space of available designs and preclude utilizing parasitic coupling or other effects within the programmable device. The practical approaches also raise the issue of why intrinsic EHW techniques do not easily apply to large design spaces, since the analytical results show only an O(L) complexity growth.

Hereford, James↗

Acoustic emission from composite materials

The two basic areas where the acoustic emission (AE) technique can be applied are materials research and the evaluation of structural reliability. This experimental method leads to a better understanding of fracture mechanisms and is an NDT technique particularly well suited for the study of propagating cracks. Experiments are described in which acoustic emissions were unambiguously correlated with microstructural fracture mechanisms. The advantages and limitations of the AE technique are noted.

Visconti, I. C.↗

Higher-Order Neural Networks Applied to 2D and 3D Object Recognition

A Higher-Order Neural Network (HONN) can be designed to be invariant to geometric transformations such as scale, translation, and in-plane rotation. Invariances are built directly into the architecture of a HONN and do not need to be learned. Thus, for 2D object recognition, the network needs to be trained on just one view of each object class, not numerous scaled, translated, and rotated views. Because the 2D object recognition task is a component of the 3D object recognition task, built-in 2D invariance also decreases the size of the training set required for 3D object recognition. We present results for 2D object recognition both in simulation and within a robotic vision experiment and for 3D object recognition in simulation. We also compare our method to other approaches and show that HONNs have distinct advantages for position, scale, and rotation-invariant object recognition. The major drawback of HONNs is that the size of the input field is limited due to the memory required for the large number of interconnections in a fully connected network. We present partial connectivity strategies and a coarse-coding technique for overcoming this limitation and increasing the input field to that required by practical object recognition problems.

Spirkovska, Lilly↗

Carbon Mineralization in Fractured Mafic and Ultramafic Rocks: A Review

Mineral carbon storage in mafic and ultramafic rock masses has the potential to be an effective and permanent mechanism to reduce anthropogenic CO 2 . Several successful pilot-scale projects have been carried out in basaltic rock (e.g., CarbFix, Wallula), demonstrating the potential for rapid CO 2 sequestration. However, these tests have been limited to the injection of small quantities of CO 2 . Thus, the longevity and feasibility of long-term, large-scale mineralization operations to store the levels of CO 2 needed to address the present climate crisis is unknown. Moreover, CO 2 mineralization in ultramafic rocks, which tend to be more reactive but less permeable, has not yet been quantified. In these systems, fractures are expected to play a crucial role in the flow and reaction of CO 2 within the rock mass and will influence the CO 2 storage potential of the system. Therefore, consideration of fractures is imperative to the prediction of CO 2 mineralization at a specific storage site. In this review, we highlight key takeaways, successes, and shortcomings of CO 2 mineralization pilot tests that have been completed and are currently underway. Laboratory experiments, directed toward understanding the complex geochemical and geomechanical reactions that occur during CO 2 mineralization in fractures, are also discussed. Experimental studies and their applicability to field sites are limited in time and scale. Many modeling techniques can be applied to bridge these limitations. We highlight current modeling advances and their potential applications for predicting CO 2 mineralization in mafic and ultramafic rocks.

25 ENERGY STORAGE↗

Specifying spacecraft flexible appendage rigidity

As a method for specifying the required degree of rigidity of spacecraft flexible appendages, an analytical technique is proposed for establishing values for the frequency, damping ratio, and modal gain (deflection) of the first several bending modes. The shortcomings of the technique result from the limitations associated with the order of the equations that can be handled practically. An iterative method is prescribed for handling a system whose structural flexibility is described by more than one normal mode. The analytical technique is applied to specifying solar panel rigidity constraints for the NASA Space Telescope. The traditional nonanalytic procedure for specifying the required degree of rigidity of spacecraft flexible appendages has been to set a lower limit below which bending mode frequencies may not lie.

Seltzer, S. M.↗

An Overview of Nanomaterials for Environmental Remediation Applications

The environmental remediation capabilities of nanoparticles were reviewed and evaluated. Nanoparticles (NPs) have been used to remediate various forms of environmental contamination. Various materials, morphologies, and conditions are required to remediate different contaminants. Nanoparticles may have benefits and/or limitations compared with traditional remediation methods. New techniques are being applied to mitigate the limitations of NPs. Nanomaterials are a promising technology for the environmental remediation. NPs have been used for the remediation of aqueous and atmospheric contaminants. Nanoparticles have been used to sequester contaminants toxic to human and environmental health. Various materials, morphologies, and conditions are necessary for the remediation of different contaminants. The remediation of heavy metals is of significant concern. Contaminants may be remediated by means of sorption or reduction. The remediation capability of nanoparticles is promising due to their high surface area and reactivity. Reaction kinetics are, therefore, notably fast. These characteristics make NPs attractive for environmental remediation. Various NPs have been used as sequestering agents for environmental contaminants. NPs have been used to remediate heavy metals as well as organic contaminants. Technical Objectives: Assess viability of nanoparticles (NPs) for environmental remediation; Review benefits and limitations of NPs; Design future experiments to test remediation capabilities of NPs. Future Plans: Create NP filters for remediation - Grow Au NPs on Stainless Steel Wool: Stainless steel wool has many defects and crevices allowing the Au NPs to grow on the surface; Stainless steel wool will not react with the heavy metal contaminants tested; NPs are embedded, so they do not have to be removed from solution. Test sorption capabilities with heavy metal contaminants in aqueous solution. Benefits of Gold NPs: Corrosion/oxidation resistant; Exhibit visible/near IR plasmon resonance; Can be synthesized by solution chemistry: cost efficient and easily scalable. Surfactants: Used to lower surface energy and prevent aggregation; Sodium citrate: anionic surfactant (-); Cetyltrimethylammonium bromide (CTAB): cationic surfactant (+); Ionic surfactants create charged NPs; Charged NPs can be used to sequester ionic contaminants (eg. heavy metals)

54 ENVIRONMENTAL SCIENCES↗

Investigation of the feasibility of optical diagnostic measurements at the exit of the SSME

Under Contract NAS8-36861 sponsored by NASA Marshall Space Flight Center, the United Technologies Research Center is conducting an investigation of the feasibility of remote optical diagnostics to measure temperature, species concentration and velocity at the exit of the Space Shuttle Main Engine (SSME). This is a two phase study consisting of a conceptual design phase followed by a laboratory experimental investigation. The first task of the conceptual design studies is to screen and evaluate the techniques which can be used for the measurements. The second task is to select the most promising technique or techniques, if as expected, more than one type of measurement must be used to measure all the flow variables of interest. The third task is to examine in detail analytically the capabilities and limitations of the selected technique(s). The results of this study are described in the section of this report entitled Conceptual Design Investigations. The conceptual design studies identified spontaneous Raman scattering and photodissociative flow-tagging for measurements respectively of gas temperature and major species concentration and for velocity. These techniques and others that were considered are described in the section describing the conceptual design. The objective of the second phase of investigations was to investigate experimentally the techniques identified in the first phase. The first task of the experimental feasibility study is to design and assemble laboratory scale experimental apparatus to evaluate the best approaches for SSME exit optical diagnostics for temperature, species concentrations and velocity, as selected in the Phase I conceptual design study. The second task is to evaluate performance, investigate limitations, and establish actual diagnostic capabilities, accuracies and precision for the selected optical systems. The third task is to evaluate design requirements and system trade-offs of conceptual instruments. Spontaneous Raman scattering excited by a KrF excimer laser pulse was investigated for SSME exit plane temperature and major species concentration measurements. The relative concentrations of molecular hydrogen and water vapor would be determined by measuring the integrated Q-branch scattering signals through narrow bandpass filters in front of photomultipliers. The temperature would be determined by comparing the signal from a single hydrogen rotational Raman line to the total hydrogen Q-branch signal. The rotational Raman line would be isolated by a monochromator and detected with a PMT.

Shirley, John A.↗

Tethers and asteroids for artificial gravity assist in the solar system

Analytical models are defined for gravity-assist trajectory changes for spacecraft passing massive compact bodies. The models are applied in an examination of the benefits of lowering a tether to an asteroid during a flyby in order to gain a trajectory change equivalent to that from a massive body (planet). Direct flybys yield velocity gains while retrograde flybys shed velocity. The magnitude of the effects are a function of the proximity to the body during flyby. This inherently limits the gravity assist technique used around planets, which usually have atmospheres and can have intense radiation fields. If a spacecraft could extend a tether (such as to be tested on the Orbiter) to snag on an asteroid surface, the potential trajectory/velocity change of the spacecraft would be limited mainly by the tether strength. The encounter physics are treated as a soft collision. Possible applications of the asteroid tether technique are outer planet, Mars and main belt asteroid exploration missions.

Penzo, P. A.↗

X-ray fluorescence microscopy methods for biological tissues

Abstract Synchrotron-based X-ray fluorescence microscopy is a flexible tool for identifying the distribution of trace elements in biological specimens across a broad range of sample sizes. The technique is not particularly limited by sample type and can be performed on ancient fossils, fixed or fresh tissue specimens, and in some cases even live tissue and live cells can be studied. The technique can also be expanded to provide chemical specificity to elemental maps, either at individual points of interest in a map or across a large field of view. While virtually any sample type can be characterized with X-ray fluorescence microscopy, common biological sample preparation methods (often borrowed from other fields, such as histology) can lead to unforeseen pitfalls, resulting in altered element distributions and concentrations. A general overview of sample preparation and data-acquisition methods for X-ray fluorescence microscopy is presented, along with outlining the general approach for applying this technique to a new field of investigation for prospective new users. Considerations for improving data acquisition and quality are reviewed as well as the effects of sample preparation, with a particular focus on soft tissues. The effects of common sample pretreatment steps as well as the underlying factors that govern which, and to what extent, specific elements are likely to be altered are reviewed along with common artifacts observed in X-ray fluorescence microscopy data.

Pushie, M. Jake (ORCID:0000000174945427)↗

Advanced feature extraction in remote sensing using artificial intelligence and geographic information systems

Traditional computer-assisted image-analysis techniques in remote sensing lag well behind human abilities in terms of both speed and accuracy. A fundamental limitation of computer-assisted techniques is their inability to assimilate a variety of different data types leading to an interpretation in a manner similar to human image interpretation. Expert systems and computer-vision techniques are proposed as a potential solution to these limitations. Some aspects of human expertise in image analysis may be codified into expert systems. Image understanding and symbolic reasoning provide a means of assimilating spatial information and spatial reasoning into the analysis procedure. Knowledge-based image-analysis systems incorporate many of these concepts and have been implemented for some well defined problem domains. Geographic information systems represent an excellent environment for this type of analysis, providing both analytic tools and contextual information to the analysis procedure.

Estes, John E.↗

Queueing models for token and slotted ring networks

Currently the end-to-end delay characteristics of very high speed local area networks are not well understood. The transmission speed of computer networks is increasing, and local area networks especially are finding increasing use in real time systems. Ring networks operation is generally well understood for both token rings and slotted rings. There is, however, a severe lack of queueing models for high layer operation. There are several factors which contribute to the processing delay of a packet, as opposed to the transmission delay, e.g., packet priority, its length, the user load, the processor load, the use of priority preemption, the use of preemption at packet reception, the number of processors, the number of protocol processing layers, the speed of each processor, and queue length limitations. Currently existing medium access queueing models are extended by adding modeling techniques which will handle exhaustive limited service both with and without priority traffic, and modeling capabilities are extended into the upper layers of the OSI model. Some of the model are parameterized solution methods, since it is shown that certain models do not exist as parameterized solutions, but rather as solution methods.

Peden, Jeffery H.↗

Advanced large scale GaAs monolithic IF switch matrix subsystem

Attention is given to a novel chip design and packaging technique to overcome the limitations due to the high signal isolation requirements of advanced communications systems. A hermetically sealed 6 x 6 monolithic GaAs switch matrix subsystem with integral control electronics based on this technique is presented. An 0-dB insertion loss and 60-dB crosspoint isolation over a 3.5-to-6-GHz band were achieved. The internal controller portion of the switching subsystem provides crosspoint control via a standard RS-232 computer interface and can be synchronized with an external systems control computer. The measured performance of this advanced switching subsystem is fully compatible with relatively static 'switchboard' as well as dynamic TDMA modes of operation.

Ch'en, D. R.↗

Geodetic Reference Instrument Transponder for Small Satellites (Gritss)

The accuracy of the Terrestrial Reference Frame is limited by systematic errors in tying the contributions from the different geodetic techniques. Local survey uncertainties are limited due to the inaccessibility of the instrument reference points. NASA is implementing a technology demonstration mission called Geodetic Reference Instrument Transponder for Small Satellites(GRITSS) that uses a small satellite as a space-based ref-refence point for tying together collocated geodetic stations. The technology being demonstrated uses a novel idea of upconverting the Global Positioning System (GPS) signals received at the satellite and transponding them to a VLBI Global Observing System (VGOS) antenna ground station. This approach does not require the satellite to be in view of more than one VLBI station at a time, allowing the use of Low Earth Orbits and an inexpensive CubeSat. The demonstration will initially involve only the NASA VGOS stations in Maryland, Hawaii, and Texas, but may be expanded later in the mission to include other international VGOS stations. This presentation will provide an overview of the GRITSS mission and the measurement concept.

S M Merkowitz↗

Geodetic Reference Instrument Transponder for Small Satellites (GRITTS)

The accuracy of the Terrestrial Reference Frame is limited by systematic errors in tying the contributions from the different geodetic techniques. Local survey uncertainties are limited due to the inaccessibility of the instrument reference points. NASA is implementing a technology demonstration mission called Geodetic Reference Instrument Transponder for Small Satellites(GRITSS) that uses a small satellite as a space-based ref-refence point for tying together collocated geodetic stations. The technology being demonstrated uses a novel idea of upconverting the Global Positioning System (GPS) signals received at the satellite and transponding them to a VLBI Global Observing System (VGOS) antenna ground station. This approach does not require the satellite to be in view of more than one VLBI station at a time, allowing the use of Low Earth Orbits and an inexpensive CubeSat. The demonstration will initially involve only the NASA VGOS stations in Maryland, Hawaii, and Texas, but may be expanded later in the mission to include other international VGOS stations. This presentation will provide an overview of the GRITSS mission and the measurement concept.

S. M. Merkowitz↗

Geodetic Reference Instrument Transponder for Small Satellites (GRITTS)

The accuracy of the Terrestrial Reference Frame is limited by systematic errors in tying the contributions from the different geodetic techniques. Local survey uncertainties are limited due to the inaccessibility of the instrument reference points. NASA is implementing a technology demonstration mission called Geodetic Reference Instrument Transponder for Small Satellites(GRITSS) that uses a small satellite as a space-based ref-refence point for tying together collocated geodetic stations. The technology being demonstrated uses a novel idea of upconverting the Global Positioning System (GPS) signals received at the satellite and transponding them to a VLBI Global Observing System (VGOS) antenna ground station. This approach does not require the satellite to be in view of more than one VLBI station at a time, allowing the use of Low Earth Orbits and an inexpensive CubeSat. The demonstration will initially involve only the NASA VGOS stations in Maryland, Hawaii, and Texas, but may be expanded later in the mission to include other international VGOS stations. This presentation will provide an overview of the GRITSS mission and the measurement concept.

S M Merkowitz↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reaching the Diffraction Limit - Differential Speckle and Wide-Field Imaging for the WIYN Telescope

Speckle imaging allows telescopes to achieve diffraction limited imaging performance. The technique requires cameras capable of reading out frames at a very fast rate, effectively 'freezing out' atmospheric seeing. The resulting speckles can be correlated and images reconstructed that are at the diffraction limit of the telescope. These new instruments are based on the successful performance and design of the Differential Speckle Survey Instrument (DSSI).The instruments are being built for the Gemini-N and WIYN telescopes and will be made available to the community via the peer review proposal process. We envision their primary use to be validation and characterization of exoplanet targets from the NASA, K2 and TESS missions and RV discovered exoplanets. Such targets will provide excellent follow-up candidates for both the WIYN and Gemini telescopes. We expect similar data quality in speckle imaging mode with the new instruments. Additionally, both cameras will have a wide-field mode and standard SDSS filters. They will be highly versatile instruments and it is that likely many other science programs will request time on the cameras. The limiting magnitude for speckle observations will remain around 13-14th at WIYN and 16-17th at Gemini, while wide-field, normal CCD imaging operation should be able to go to much fainter, providing usual CCD imaging and photometric capabilities. The instruments will also have high utility as scoring cameras for telescope engineering purposes, or other applications where high time resolution is needed. Instrument support will be provided, including a software pipeline that takes raw speckle data to fully reconstructed images.

detector↗

Emerging Electrochemical Techniques for Probing Site Behavior in Single-Atom Electrocatalysts

Single-atom catalysts (SACs) have aroused tremendous interest over the past decade, particularly in the community of energy and environment-related electrocatalysis. A rapidly growing number of recent publications have recognized it as a promising candidate with maximum atomic utilization, distinct activity, and selectivity in comparison to bulk catalysts and nanocatalysts. However, the complexity of localized coordination environments and the dispersion of isolated sites lead to significant difficulties when it comes to gaining insight into the intrinsic behavior of electrocatalytic reactions. Furthermore, the low metal loadings of most SACs make conventional ensemble measurements less likely to be accurate on the subnanoscale. Thus, it remains challenging to probe the activity and properties of individual atomic sites by available commercial instruments and analytical methods. In spite of this, continuing efforts have lately focused on the development of advanced measurement methodologies, which are very useful to the fundamental understanding of SACs. There have recently been a number of in situ/operando techniques applied to SACs, such as electron microscopy, spectroscopy, and other analysis methods, which support relevant functions to identify the active sites and reaction intermediates and to investigate the dynamic behavior of localized structures of the catalytic sites. This Account aims to present recent electrochemical probing techniques which can be used to identify single-atomic catalytic sites within solid supports. First, we describe the basic principles of molecular probe methods for the study and analysis of electrocatalytic site behavior. In particular, the in situ probing technique enabled by surface interrogation scanning electrochemical microscopy (SISECM) can measure the active site density and kinetic rate with high resolution. An alternative electrochemical probing technique is further demonstrated on the basis of single-entity electrochemistry, which allows the unique electrochemical imaging of the size and catalytic rate of single atoms, molecules, and clusters. Next, the merits and limitations of different electrochemical techniques are then discussed, along with perspectives for future prospects. Apart from this, we further showcase the powerful capability of emerging electrochemical probing techniques for determining significant effects and properties of SACs for various electrocatalytic reactions, including oxygen reduction and evolution, hydrogen evolution, and nitrate reduction. Overall, electrochemical techniques with atomic resolution have greatly increased opportunities for observing, measuring, and understanding the surface and interface chemistry during energy conversion. In the future, it is anticipated that the development of electrochemical probing techniques will be advanced with innovative perspectives on the behavior and features of SACs. We hope that this Account can contribute in several ways to promoting the fundamental knowledge and technical progress of emerging electrochemical measurements for studying SACs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗