Ultra-smooth and high efficiency alkali antimonide photocathodes for future light sources
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A helical superconducting undulator includes a cylindrical magnetic core through which a bore hole allows the passage of charged particles. A single superconducting wire wraps the magnetic core guided by helical flights and cylindrical protrusions, to create interleaved helical windings on the magnetic core. An electrical current may be supplied to the superconducting wire to generate a periodic helical magnetic field in the bore. The helical superconducting undulator also includes a strong-back enclosure that acts as an epoxy mold during epoxy impregnation, a structural support to ensure straightness of the undulator after epoxy impregnation, and assists in cooling and thermal control of the magnetic core and superconducting wire during device operation.
Explore the source record for details and available documents.
A compact electron accelerator suitable for Compton source applications is in design at the Center for Accelerator Science at Old Dominion University and Jefferson Lab. The design includes a KE=1.24 MeV low-emittance, optimized superconducting electron gun; a 25 MeV linac with multi-spoke 4.2 K superconducting cavities; and transport that combinesmagnetic longitudinal bunch compressor and transvese final focus. We report on the initial designs of each element, including end to end simulations with ASTRA and elegant, and expected beam parameters.
In this paper we describe the R&D roadmap at HZB for the development of a high-brightness, high average current SRF electron gun for an energy-recovery linac based synchrotron radiation source.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
At Brookhaven Lab, a team of researchers has overcome a major x-ray focusing obstacle to allow the study of molecules, atoms, and advanced materials at the nanoscale, which is on the order of billionths of a meter. Their innovative method uses a type of refractive lens called a kinoform lens --similar to the kind found in lighthouses -- in order to focus the x-rays down to the extremely small spots needed for a sharp image at small dimensions.
Explore the source record for details and available documents.
A novel ionization/sampling method termed triboionization was developed. Triboionization is an ionization method that only uses cohesive substances, such as food wrap or sticky tape, and does not require an electrode, electric power supply, heat source, light source, radiation, or gas, unlike most other conventional ambient ionization methods. In this study, the sample compound attached to adhesive tape or plastic wrap was quickly peeled off at a distance of approximately 2 cm from the atmospheric interface of a mass spectrometer. All of the five types of food wrap and 13 types of adhesive tape tested successfully ionized caffeine. Nine out of ten model compounds were detected as the corresponding molecular ions in the positive or negative mode by this ionizing contrivance using an oriented polypropylene adhesive tape. The detected molecular ions were typically protonated molecules or sodium adducts in the positive mode or deprotonated molecules in the negative mode. The elemental compositions of the observed ions were confirmed within 5 ppm by high-resolution mass spectrometry. The triboionization phenomenon was considered to depend on physical and electronic events caused by peeling off a cohesive substance. Triboionization is able to provide a compact ion source using only mechanical mechanisms. Additionally, triboionization allows sticky tape to be used as a convenient sampling device for surface analysis. .
Lighting application efficiency (LAE) describes the efficient delivery of light from the light source to the lighted task and is viewed as a new frontier—increasing energy savings with solid-state lighting (SSL) technologies. The framework for LAE that is proposed by the U.S. Department of Energy (DOE) consists of four major elements: light source efficiency, optical delivery efficiency, spectral efficiency, and intensity effectiveness. This report focuses on a sampling of the available SSL products that can be broadly defined as having modified spectral output because the method of spectra modification has a significant impact on light source efficiency and long-term optical delivery and spectral efficiencies. This report focused on the changes in light source, optical delivery, and spectral efficiencies that occur during aging of SSL devices. An accelerated stress test (AST) regiment was developed for the devices under test (DUTs) examined in this report to provide insights into how the performance of SSL devices change with aging. The AST protocols demonstrate that the SSL products discussed in this report often reduce light source efficiency to achieve different spectral characteristics. In addition, aging of the optical components (e.g., lenses, solder masks) in SSL devices can produce increased light absorption, which negatively impacts optical delivery efficiency and light source efficiency. The modified spectral outputs of the selected SSL products discussed in this report come in a variety of form factors and achieve enhanced optical performance by using a variety of methods. All of the products examined in this study use mid-power light-emitting diodes (MP-LEDs), although the number, configuration, phosphor content, and light-emitting diode (LED) pump of the MP-LEDs differ. Product MS-1 is a 60-watt (W) replacement A19 lamp with a hermetically sealed glass globe, which contains an embedded optical filter to absorb green and yellow emissions, thereby creating a “sunlike” modified spectrum. Product MS-2 is a 60-W replacement A19 lamp with 30 MP-LEDs, and it uses a violet LED pump, along with green and red phosphor emissions, to produce a “healthy” spectrum. This spectrum omits blue emissions in an effort to reduce melanopic lux. Product MS-3 is an LED module consisting of 21 MP-LEDs that use a violet LED pump, along with blue, green, and red phosphors, to produce a “sunlike” spectrum. Products MS-4 and MS-5 are both 6-inch (in) downlights that use a manual switching mechanism so that users can select application-specific correlated color temperatures before installation. Products MS-4 and MS-5 both contain two LED primaries (2,700 Kelvin [K] and 5,000 K) for spectral tuning. Product MS-4 contains 12 MP-LEDs for each LED primary, and Product MS-5 contains 10 MP-LEDs for each LED primary. This report summarizes the overall findings from up to 8,000 hours (hrs) of AST on the lamp DUTs (Products MS-1 and MS-2); up to 5,000 hrs of AST on the LED light engine DUTs (Product MS-3); and up to 7,000 hrs of AST on the downlight DUTs (Products MS-4 and MS-5). The AST procedures used in this study included a room temperature operational life (RTOL) test, an operational life test conducted at 45 degrees Celsius (°C; 45OL) test, an operational life test conducted at 75°C (75OL), a wet high-temperature operational life test performed at 65°C and 90% relative humidity (6590), and a wet high-temperature operational life test performed at 75°C and 75% relative humidity (7575). The AST procedures used for Products MS-1 and MS-2 were RTOL, 45OL, and 6590. The AST procedures used for Products MS-3, MS-4, and MS-5 were RTOL, 75OL, and 7575. During the ASTs described herein, separate populations of each product (three DUTs in each population for Products MS-1, MS-2, MS-4, and MS-5; four DUTs in each population for Product MS-3) were subjected to power cycling of 1 hr on and 1 hr off. The key findings from this study include the following. Enhanced optical performance came at the cost of reduced light source efficiency for the lamps and light engines examined in this study. The optical filter used to produce a “sunlike” spectrum for Product MS-1 reduced light source efficiency by 26%, from 113 lumens per watt (lm/W) to 85 lm/W. Products MS-2 and MS-3 that used a violet-pumped LED to achieve “healthy” and “sunlike” enhanced optical performance, respectively, suffered the largest reduction in initial light source efficiency (49 lm/W for Product MS-2 and 68 lm/W for Products MS-3) perhaps because of the use of violet LED as the optical pump. Product MS-2 also had the poorest color fidelity because of undersaturation of blues and oversaturation of greens and yellows. Chromaticity maintenance of the products in this study was generally good, with parametric failure only occurring for one product at one AST condition (i.e., Product MS-3 at 7575). The chromaticity shift for Product MS-3 in 7575 test conditions resulted from reduced emissions of the broad green and red phosphors used to mimic sunlight in the 500–750 nanometer (nm) range. As a result of these phosphor emission losses, chromaticity shifted toward the more stable violet-pumped LED and blue phosphor. Although chromaticity maintenance was acceptable for most products tested, different chromaticity shift mechanisms were observed for temperature and humidity tests compared with temperature alone for Products MS-1, MS-2, and MS-3. For Product MS-1, a relative increase in green emissions was observed with humidity, which may indicate humidity-accelerated degradation of the optical filter at green wavelengths (optical delivery efficiency reduction) or degradation of the emitters in the red region (spectral efficiency reduction). The violet-pumped products (i.e., MS-2 and MS-3) exhibited different chromaticity shift behavior in the temperature-humidity environments, with Product MS-2 shifting generally yellow because of photo-induced oxidation of the plastic globe (i.e., a reduction of optical delivery efficiency) and Product MS-3 shifting toward violet and blue emitters because of faster loss of emission from green and red phosphors (i.e., a reduction in spectral efficiency). Because of an initial drop in power consumption, the light source efficiency of downlights (Products MS-4 and MS-5) increased at RTOL throughout the test duration. The light source efficiency initially increased during 75OL until a decay in luminous flux maintenance (LFM) dominated light source efficiency, whereas the light source efficiency decreased for the entire 7575 test duration. It was found that increasing the ambient environment of an SSL device from 25°C to 75°C decreases the LFM by 2.7 to 5.5, depending on design of the SSL device. Adding humidity to the system (75OL to 7575) was found to decrease LFM by another factor of approximately 3.0. A common location of failure was identified for the downlights (Products MS-4 and MS-5) operated in the 7575 environment. This failure abruptly occurred between 3,000 to 5,000 hrs of testing on the film capacitor of the electromagnetic interference (EMI) filter near the diode bridge for 11 of the 12 downlights. It is likely that this failure was caused by a combination of the high electrical voltage across the capacitor, the location of the capacitor near the heat sources (e.g., transformers, diode bridges, power resistors), and the high stress environment of 7575. Longer test times are needed to fully understand the LFM, luminous efficacy changes, and chromaticity shifts for some of the products. Because of the high reliability, light source efficiency, and spectral tuning capabilities of LEDs, the expectations of LAE for SSL products are greatly increased over traditional lighting products. The data gathered in this report begin to provide an understanding of the tradeoffs that current SSL products undergo when optimizing the different efficiency elements of LAE. As discussed in this report, the findings from the tests conducted show that the optimization of spectral efficiency can come at the cost of initial light source efficiency. Furthermore, the introduction of violet LEDs can promote long-term optical delivery efficiency degradation, and the introduction of optical filters or new phosphors can lead to unwanted spectral efficiency changes because the ratio of phosphor emitters changes with aging. The data presented in this report also identified a common failure location in 6-in downlights. The results regarding long-term behavior of the modified spectra devices studied provide valuable information about changes to the light source, spectral, and optical delivery efficiencies as the devices age. This information can be used to improve future SSL designs.
In this paper, a laboratory-based penning plasma discharge source is reported which has been developed in two anode configurations and is able to produce visible and VUV lights simultaneously. The developed source has simultaneous diagnostics facility using Langmuir probe and optical emission spectroscopy. The two anode configurations, namely, double ring and rectangular configurations, have been studied and compared for optimum use of the geometry for efficient light emissions and recording. The plasma is produced using helium gas and admixture of three noble gases including helium, neon, and argon. The source is capable to produce eight spectral lines for pure helium in the VUV range from 20 to 60 nm and total 24 spectral lines covering the wavelength range 20–106 nm for the admixture of gases. The large range of VUV lines is generated from gaseous admixture rather from the sputtered materials. The recorded spectrum shows that the plasma light radiations in both visible and VUV range are larger in double ring configuration than that of the rectangular configurations at the same discharge operating conditions. To clearly understand the difference, the imaging of the discharge using ICCD camera and particle-in-cell simulation using VORPAL have also been carried out. The effect of ion diffusion, metastable collision with the anode wall and the nonlinear effects are correlated to explain the results.
The working curve measurement in photopolymer additive manufacturing is a ubiquitous measure of the cure depth of a printing resin as a function of radiant exposure of light. The fit parameters from this measurement (the depth of light penetration D p and the critical exposure E c ) are used to evaluate and report a resin’s printability, optimize processing parameters, and inform print and resin quality control. Despite its widespread use, the working curve lacks a standard measurement method. Here, following up on our paper “Results of an Interlaboratory Study on the Working Curve in Vat Photopolymerization” from last year, an interlaboratory study on the working curve was performed using calibrated, reproducible, bandpass filtered light sources. With these light sources, the variability between labs in measured working curves was dramatically reduced from the initial interlaboratory study. Aggregate data from this experiment produced reliable D p and E c measurements at 385 nm of 39.2 ± 3.7 µm and 12.3 ± 3.0 mJ cm −2 , respectively. At 405 nm the values of D p and E c are 69.3 ± 3.8 µm and 17.9 ± 2.3 mJ cm −2 , respectively. The results are agnostic to the thickness measurement tool utilized by participants, ensuring broad applicability across laboratories. We also tested the generalizability of the proposed method of using a filtered light source by filtering a commercial 405 nm light source and obtaining a working curve in agreement with the aggregate data from the interlaboratory study. This interlaboratory study provides a basis for a documentary standard for the working curve, so that the entire photopolymer additive manufacturing industry can share reproducible and interoperable working curve data.
An optical inspection system for detecting sub-micron features on a sample component. The system may have a controller, a camera responsive to the controller for capturing images, an objective lens able to capture submicron scale features on the sample component, and a pulsed light source. The pulsed light source may be used to generate light pulses. The camera may be controlled to acquire images, using the objective lens, only while the pulsed light source is providing light pulses illuminating a portion of the sample component. Relative movement between the sample component and the objective lens is provided to enable at least one of a desired subportion or an entirety of the sample component to be scanned with the camera.