Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “injection test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

nuSTORM Accelerator Challenges and Opportunities

The nuSTORM facility uses a stored muon beam to generate a neutrino source. Muons are captured and stored in a storage ring using stochastic injection. The facility will aim to measure neutrino-nucleus scattering cross-sections with uniquely well-characterized neutrino beams; to facilitate the search for sterile neutrino and other Beyond Standard Model processes with exquisite sensitivity, and to provide a muon source that makes an excellent technology test-bed required for the development of muon beams capable of serving as a multi-TeV collider. In this paper, we describe the latest status of the development of nuSTORM, the R&D needs, and the potential for nuSTORM as a Muon Collider test facility.

43 PARTICLE ACCELERATORS↗

HEMP Transformer Defense Through Power Electronics

High altitude electromagnetic pulses and geo-magnetic disturbances have the potential to severely impact the electric power grid by damaging large power transformers and causing severe power quality issues. This impact comes as a result of a quasi-static bias induced on transmission lines by geomagnetically induced currents which saturate magnetic components in the electric power system. This paper introduces the concept of utilizing a h-bridge inverter on the neutral of a LPT to inject a DC bias equivalent voltage onto the neutral side of the transformer windings. This biasing floats the transformer windings, eliminating the effect of the DC current and keeping the transformer from saturating. Schematic diagrams will be presented, along with simulation model data using Typhoon and PLECS, and finally test results from a benchtop hardware test.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mixing-Controlled Combustion of Ethanol Enabled by Prechamber Ignition (PC-MCC): A Preliminary Experimental Demonstration

This experimental study presents preliminary investigations of prechamber-enabled mixing-controlled combustion (PC-MCC) at −2 bar brake mean effective pressure (BMEP) and 2200 rpm with fuel-grade ethanol (E98). Experimental results are conducted on a prechamber retrofitted single-cylinder Caterpillar C9.3B test engine. First, a series of prechamber-only experiments were conducted with a motored engine to evaluate the salient combustion trends in response to relevant prechamber operating parameters. Under firing conditions, the prechamber operating strategy was assessed with respect to the impact on ignition assistance of direct-injected E98 and overall engine performance. The preliminary results indicate the jet-induced ignition process is robust and prompts diffusion combustion of E98 at diesel-like boundary conditions. Here, the effect of external exhaust gas recirculation (EGR) on the residual tolerance of the prechamber combustion process was also investigated and showed stable combustion in both the main chamber and prechamber up to 30% EGR. Experiments were also conducted with the stock diesel engine for baseline comparison. At matched combustion phasing, mixing-controlled combustion of ethanol enabled by prechamber ignition was able to achieve heightened gross thermal efficiency while simultaneously reducing NOx and practically eliminating smoke emissions relative to diesel combustion. In addition, the covariance of load and standard deviation of combustion phasing was diesel-like and less than 2% and 1 CAD, respectively.

PC-MCC↗

Performance Evaluation of a Single-Phase Grid-Forming Inverter Through Hardware Experiments

This study conducts hardware experiments to assess the performance of a commercial single-phase grid-forming (GFM) inverter using a purely hardware-based approach. We adhere to a testing protocol for the GFM inverter and enhance it by exploring the transient performance of GFM inverters across various grid dynamic events. Quantifiable performance metrics are established for each testing scenario to gain insights into the performance of the single-phase GFM inverters. Based on the comprehensive tests, the following observations are summarized: 1) The performance of the single-phase GFM inverter is satisfactory, and it is capable of being the islanding master for residence homes when the main grid is gone. 2) For frequency response, the inverter is able to stay connected but cannot inject the needed active power to support the grid. This may be improved by the manufacturer by using droop control. 3) The GFM inverter exhibits harmful transients in voltage and frequency during islanding operation, which can be enhanced by maintaining the same operating points before and after the breaker is open.

dynamic performance↗

An X-Band Ultra-High Gradient Photoinjector

High brightness beams appealing for XFELs and UEM essentially imply a high current and a low emittance. To obtain such beams we propose to raise the accelerating voltage in the gun mitigating repealing Coulomb forces. An ultra-high gradient is achieved utilizing a short-pulse technology. We have designed a room temperature X-band 1,5 cell gun that is able to inject 4 MeV, 100 pC bunches with as low as 0.15 mcm normalized transverse emittance. The gun is operated with as high gradients as 400 MV/m and fed by 200 MW, 10 ns RF pulses generated with Argonne Wakefield Accelerator (AWA) power extractor. We report results of low RF power tests, laser alignment test results, and successful gun conditioning results carried out at nominal RF power.

43 PARTICLE ACCELERATORS↗

The Case for Reducing Emissions from Heavy-Duty Off-Road Applications via Ducted Fuel Injection

Designers of heavy-duty diesel engines use a variety of techniques to improve efficiency and reduce pollutant emissions. Ducted fuel injection (DFI), high fuel injection pressures, optimized injection orifices, multiple injection sites, and oxygenated fuels are a few techniques used by designers to improve fuel/charge-gas mixtures within the combustion chamber to improve efficiency and emissions results. Ducted fuel injection (DFI) has been proven to substantially reduce soot for low- and mid-load conditions in heavy duty engines, without significantly increasing nitrogen oxides (NO x ). This study investigates the performance of DFI utilizing conventional diesel fuel and the potential the technique has for future research utilizing varieties of test fuels and operating parameter values. Optimization for high engine efficiency and low emissions will help facilitate DFI deployment for substantial environmental benefits in heavy-duty sectors where electrification and/or carbon-free fuels aren’t feasible.

33 ADVANCED PROPULSION SYSTEMS↗

SUBTASK 1.6 – BASIN ELECTRIC CARBON STORAGE RESEARCH PROJECT: NOVEL MONITORING TECHNIQUES

The Energy & Environmental Research Center (EERC) conducted baseline activities associated with an applied research project at Basin Electric Power Cooperative’s (Basin’s) carbon capture and storage (CCS) site in Beulah, North Dakota, to establish novel carbon storage-monitoring techniques as commercial methods under Cooperative Agreement No. DE-FE0024233, Subtask 1.6. The following report summarizes the baseline activities performed and briefly describes the subsequent (operational monitoring) activities that have been proposed to the U.S. Department of Energy (DOE) as part of the overall project to develop and demonstrate novel monitoring techniques at North America’s largest permitted CCS operation. Dakota Gasification Company (DGC), a wholly owned subsidiary of Basin, owns and operates the Great Plains Synfuels Plant (GPSP) approximately 5 miles northwest of the town of Beulah, North Dakota (Figure 1). In 2023, DGC received approval from the North Dakota Industrial Commission (NDIC) to develop a storage facility on-site for injecting a stream of carbon dioxide (CO2) captured from GPSP. DGC will transport the captured CO2 stream with approximately 6.8 miles of transmission lines that extend north of GPSP and inject >1 million tonnes (MMt) of CO2 annually (>1 MMt/yr) over a 12-year period with up to six underground injection control (UIC) Class VI-compliant injection wells completed in the Broom Creek Formation, a predominantly sandstone reservoir and saline aquifer underlying GPSP. The Broom Creek Formation lies approximately 5900 feet (ft) below ground surface (bgs) at GPSP. The commercial scale (i.e., >1 MMt/yr) of DGC’s permitted carbon storage project is ideal for developing and testing the novel monitoring techniques included within Subtask 1.6. The goals of this project are to demonstrate 1) the cost-effectiveness of novel monitoring technologies included as part of this research, 2) technology capability for tracking the CO2 plume and/or associated pressure response in the subsurface and monitoring out-of-zone migration, and 3) compliance with UIC Class VI program requirements. The research activities proposed for the overall project include 1) design of an automated, integrated, modular (AIM) monitoring station; 2) time-lapse electromagnetic (EM) field surveys; 3) drone-based surveillance studies; 4) time-lapse monitoring with seismic methods; 5) advanced wellbore-monitoring methods; 6) deployment of an AIM monitoring network; 7) EM monitoring of CO2 with real-time data processing; 8) continued seasonal drone-based surveillance studies; 9) seismic monitoring with passive and active surveys; and 10) wellbore monitoring with nuclear magnetic resonance (NMR) for near-surface characterization. Completion of Activities 1.0–5.0 (baseline activities) are described in this report. Upon authorization of funding by DOE, the EERC will initiate Activities 6.0– 10.0 (operational monitoring activities). Current state-of-the-art (SOA) carbon storage-monitoring techniques require countless labor hours dedicated to the acquisition of data. Once data are gathered, these SOA techniques often rely on commercial facilities to process raw data from the field. However, it is anticipated that next-generation monitoring techniques, such as those being demonstrated, will lower acquisition footprints, be less operationally intensive, and improve data acquisition efficiencies. These new techniques are more conducive to the application of machine learning, artificial intelligence, and automation, thus providing a pathway for integration into active control systems, informing site operability, and improving the integration of data for future CCS projects across the United States. Additionally, reclaimed and active mining lands are present within the project site, creating a unique opportunity to demonstrate the effectiveness of remote sensing and surface-based geophysics monitoring techniques at similar project sites that may include disturbed, unconsolidated, or actively excavated near-surface environments. The efforts included in the overall project will produce necessary designs, learnings, and data acquired during the baseline and operational monitoring periods that are necessary for time-lapse demonstration and validation of the described monitoring techniques. In addition, it is anticipated that the monitoring technologies included in this study will be compliant with UIC Class VI requirements to enable the potential for implementation at other CCS sites across the United States.

42 ENGINEERING↗

Experimental and simulated heating in nanocrystalline diamond charge exchange injection films using an electron beam to mimic SNS conditions

Nanocrystalline diamond (NCD) foils have been in use at the Spallation Neutron Source as primary stripper foils for charge exchange injection since the machine’s inception. NCD’s low atomic number leads to reduced beam scattering while still being easy to handle, as opposed to even lighter elements. NCD foils also have the benefit of being free-standing, and rigid when grown under the right conditions to minimize residual stresses. This study overviews a method to mimic the Spallation Neutron Source (SNS) beam and characterize thermally driven failure of NCD foils. To do this, a foil test stand was developed with in situ diagnostics that tracks signs of foil sublimation and thinning. The foil test stand’s electron beam is equated to the SNS beamline by comparing peak deposited energy densities for both beams. Post-mortem testing is also conducted to help elucidate changes the NCD foils undergo during exposure to the beam. Further, a COMSOL simulation was also developed as a method to assess potential future changes to the NCD film and predict how changes to beam conditions will effect foil temperatures. This method allows for examination of the NCD foil’s thermal limits and can be used to assess future changes to SNS stripper foils.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance Evaluation of Vertical Federated Machine Learning Against Adversarial Threats on Wide-Area Control System: Preprint

Federated machine learning (FL) is gaining significant popularity to develop cybersecurity solutions in power grids because of its advanced capability to support decentralized data handing at local devices, its privacy preservation, and its low-bandwidth requirement. However, the evolving adversarial machine learning (AML) threats raise significant concerns for the cybersecurity of FL architectures. The FL-based split neural network (SplitNN) achieves high performance through the decentralized training of local neural network models while preserving data privacy across multiple entities. In this paper, we propose a methodology for evaluating the performance of a vertical FLbased anomaly detector against different types of AML attacks, including denial-of-service attacks, adversarial data injection attacks, and replay attacks on the trained local models deployed in the grid network. For a case study, we consider the modified IEEE 13-bus system, and we develop SplitNN-based binary and multiclass classification models to detect, locate, and identify different types of data integrity attacks on the volt-watt control with two pooling layers: maximum pooling and AvgPool. Our experimental results, computed through performance metrics, reveal that the severity of these AML attacks varies with the integrated pooling mechanism, the type of classification model, and the nature of the cyberattack. Further, the AML attacks negatively impacted the prediction time per sample for the pretrained SplitNN during the online testing.

adversarial threats↗

Model development for flash boiling spray and validations with isooctane, hexane, ethanol and their binary mixtures

The objective of this study is to develop a comprehensive model for spray atomization under the consideration of flash boiling, which includes nucleation, bubble growth, and droplet breakup. Although flash boiling has been previously studied, there is still no well-established analytical and numerical model of their mechanisms, or general guidelines on the implementation of this atomization strategy. In this study, detailed formulations are elaborated for the unified spray atomization model under both non-flash and flash boiling conditions. Next, the model was implemented into CFD software and 3-D simulations were performed for model validations. Two fuel blends are tested: ethanol-isooctane blends and hexane-isooctane blends. Simulation results were compared with the experimental measurements conducted using two methodologies, DBI (Diffuse Backlight Imaging) system for spray images captured by a high-speed camera, and a PDA (Phase Doppler Anemometry) system for droplet size measurement during the spray injection process. It was found that the current flash boiling model can accurately capture the spray characteristics under different environment conditions, such as the spray plume interactions and liquid penetration. The averaged Sauter mean diameter (SMD) calculations match the measurement sufficiently well. The spray structures for both single- and multi-component fuels during the injection process are well represented by current model.

42 ENGINEERING↗

A Two-Level Model Predictive Control-Based Approach for Building Energy Management including Photovoltaics, Energy Storage, Solar Forecasting and Building Loads

This paper uses a two-level model predictive control-based approach for the coordinated control and energy management of an integrated system that includes photovoltaic (PV) generation, energy storage, and building loads. Novel features of the proposed local controller include (1) the ability to simultaneously manage building loads and energy storage to achieve different operational objectives such as energy efficiency, economic cost efficiency, demand response and grid optimization through the design of specific power trajectory tracking performance functionals, (2) an energy trim function that minimizes the impact of solar forecasting errors on system performance, and (3) the design of a state of charge controller that uses day-ahead forecast of solar power and building loads to intialize energy storage at the start of each day. The local controller is tested in simulation using an exemplary system with PV generation, energy storage and dispatchable building loads. Two sample days with different PV forecasts and multiple case scenarios are considered, and the performance of the algorithm in managing the real and reactive net building load trajectories and the ramp rate of PV injections into the utility network are evaluated. The simulations are based on actual forecasted and measured PV data, and the results show that the local controller meets the tracking requirements for real and reactive power within the operating constraints of the building.

14 SOLAR ENERGY↗

Chemo‐mechanical Alterations Induced From CO 2 Injection in Carbonate‐Cemented Sandstone: An Experimental Study at 71 °C and 29 MPa

Abstract Carbon capture, utilization, and storage may lead to mechanical degradation of the subsurface reservoir from fluid‐rock interaction, which could lead to wellbore instability or reservoir compaction. To better understand potential relationship between mechanical degradation with various carbonate cement textures and compositions in sandstone reservoirs, six flow‐through experiments were conducted. Formation water (TDS = 5,390 mg/L) enriched with CO 2 flowed through two types of Pennsylvanian Morrow B Sandstone: an ankerite‐siderite‐cemented sandstone (disseminated cement texture) and a calcite‐cemented sandstone (poikilotopic cement texture). The experiments produced little change in permeability in the ankerite‐siderite‐cemented sandstone, but permeability increased up to more than 1 order of magnitude in the calcite‐cemented sandstone. Ultrasonic measurements and cylinder‐splitting tests (also known as Brazilian tests) suggested negligible mechanical degradation of the ankerite‐siderite‐cemented sandstone. Variable changes, with significant mechanical degradation in the static moduli, were observed in the calcite‐cemented sandstone. Thus, dissolution of the disseminated ankerite‐siderite cement (0.28–0.30%) had minimal impact on modifying the flow network and the mechanical integrity of the sandstone, whereas dissolution of the poikilotopic calcite cement (0.89–1.13%, quantified with fluid chemistry and visualized with X‐ray microcomputed tomography) impacted the mechanical strength of the sandstone by disconnecting framework grains. With the high water‐to‐rock mass ratios (7.3–8.2) and number of pore volumes (147–675) employed in these experiments, potential risks are most relevant to regions near injection wells. Ultimately, the chemo‐mechanical effects induced by CO 2 injection are strongly influenced by the cement texture and composition and the burial history of the reservoir rock.

Wu, Z.↗

Initial Results From the Newly Upgraded LTX- β

LTX-β, the upgraded Lithium Tokamak Experiment, recently began its first campaign with a goal to study the transport properties of gradient-free electron temperature profile equilibria with increased toroidal field and neutral beam injection. The temperature-gradient-free equilibria in LTX were enabled by the lithium plasma-facing surface. To make the lithium surface conditions more consistent for LTX-β, a new, faster lithium evaporator system has been developed. The toroidal magnetic field has been nearly doubled to ≥0.3 T. Auxiliary heating and fueling with a high flux (35 A, 20 kV) neutral beam has begun. The beam provides core fueling without cold edge neutrals, to test whether flat temperature profiles can be sustained, and makes possible core ion temperature measurements via charge exchange recombination spectroscopy. Neutral beam fueling has been demonstrated with increases in line-integrated density. The coupling of the beam matches well with NUBEAM predictions for shine through. Improved performance has been observed following lithium evaporative coatings and an increase in field strength.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Protection Against Graph-Based False Data Injection Attacks on Power Systems

Graph signal processing (GSP) has emerged as a powerful tool for practical network applications, including power system monitoring. By representing power system voltages as smooth graph signals, recent research has focused on developing GSP-based methods for state estimation, attack detection, and topology identification. Included, efficient methods have been developed for detecting false data injection (FDI) attacks, which until now were perceived as non-smooth with respect to the graph Laplacian matrix. Consequently, these methods may not be effective against smooth FDI attacks. In this paper, we propose a graph FDI (GFDI) attack that minimizes the Laplacian-based graph total variation (TV) under practical constraints. In addition, we develop a low-complexity algorithm that solves the non-convex GDFI attack optimization problem using ell_1-norm relaxation, the projected gradient descent (PGD) algorithm, and the alternating direction method of multipliers (ADMM). We then propose a protection scheme that identifies the minimal set of measurements necessary to constrain the GFDI output to high graph TV, thereby enabling its detection by existing GSP-based detectors. Our numerical simulations on the IEEE-57 bus test case reveal the potential threat posed by well-designed GSP-based FDI attacks. Moreover, we demonstrate that integrating the proposed protection design with GSP-based detection can lead to significant hardware cost savings compared to previous designs of protection methods against FDI attacks.

Morgenstern, Gal↗

ARC disruption physics and strategy

Commonwealth Fusion Systems (CFS) plans to operate a tokamak power plant called ARC in the early 2030s. Tokamak plasmas have stability limits that, if crossed, lead to a rapid termination of the plasma, referred to as a disruption. Disruptions pose a melt risk to the first wall resulting from thermal and non-thermal particle heat fluxes, and an electromagnetic loading risk on all metal components within the equilibrium coils. A comprehensive set of models is used herein to provide an assessment of both mitigated and unmitigated ARC disruption loads. A preliminary massive gas injection system is baselined and a runaway electron mitigation coil option is proposed to close possible gaps in the baseline. It is predicted that all ARC disruption loads are within a factor of 2 of the disruption loads in SPARC, a tokamak presently under construction by CFS, and therefore SPARC provides an opportunity to calibrate models, test solutions and inform the design of ARC. The goal for ARC is disruption-free operation, however, the pragmatic design target is to withstand one mitigated disruption per day, and to restart the plasma following mitigation in tens of seconds without interrupting the power output. Unmitigated disruptions must be rare, and experience with unmitigated disruption impacts in SPARC will better define what rare means. The implications of this strategy for plasma disruptivity and disruption prediction are discussed, and operating the ARC scenario on SPARC is expected to refine the ARC final design and operational plan.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of living grass Roots and endophytic fungal hyphae on soil hydraulic properties

Soil hydraulic properties are often estimated based on laboratory data or pedotransfer functions dependent on soil physical properties, which often do not consider potential impacts of soil roots or fungal hyphae. Here, we first review current knowledge of how these soil biotic components affect hydraulic properties, then we conducted laboratory experiments to specifically test if the presence of roots and mycorrhizal fungi had a significant effect on the hydraulic properties of two soils with contrasting textures: Flint sand and Hamblen silt loam. Soil cores were seeded with (Panicum virgatum) and grown in a greenhouse over three separate growth periods. The endophytic fungus Serendipita indica was injected as liquid inoculant into designated mycorrhizal cores. Saturated hydraulic conductivity (K sat ) measurements were made with a constant head permeameter, and soil water retention curves were obtained by the evaporation method, supplemented at the dry end for Hamblen silt loam with water activity meter data. Retention curve parameters were obtained by fitting the van Genuchten equation to the resulting measurements. Mean root volume ratios were higher in the mycorrhizal inoculated treatment than in the uninoculated treatment for both soils. For Flint sand, analysis of variance revealed that K sat was reduced by the presence of roots as compared to bare soil. This was likely due to roots clogging soil pores. Results also indicated the presence of roots changed the shape of the water retention curve for Flint sand by increasing water content at saturation and by reducing the slope of the curve. These changes suggested roots created additional porosity and broadened the pore-size distribution. The presence of mycorrhizal fungi accentuated the root effects. The influence of roots and mycorrhizal fungi on hydraulic properties was less obvious for the Hamblen silt loam, as none of the treatments differed from each other at p < 0.05. The results highlight the necessity to consider the impact of root and fungal structures on models of soil hydraulic properties.

59 BASIC BIOLOGICAL SCIENCES↗

Erosion-Corrosion Detection in Carbon Steel Pipe Loops using SRNLs Thickness and Mass Loss Measurement Coupons - 20464

Structural health of waste transfer infrastructure is of utmost importance to DOE and communities surrounding their active sites. A Fitness-for-Service (FFS) program for the Waste Transfer System has been implemented by the US Department of Energy (DOE) for the purposes of evaluating and quantifying the degradation of critical components. Currently, the method of approach is to section and evaluate pipelines that have been removed at end service. In order to augment data collection methods applied to making lifespan estimates of waste transfer system components, Florida International University (FIU) has been investigating new-technology based strategies for quantifying the rate of degradation. Present research considers the option of a coupon system installed on a section of pipe at points of interest that will provide easy access to high resolution measurements of erosion/corrosion rates during operation. Researchers at Savannah River National Laboratory (SRNL) have developed this novel solution for in situ erosion and corrosion measurements in many applicable locations such as tanks, pipes, ducts, and injection points. The coupons are approximately 12.7 mm (1/2 inch) in diameter and 25.4 mm (1 inch) in length and can be placed in the pipe sections using Swagelok compression fittings. The coupon design allows for monitoring of the total degradation resulting from corrosion and erosion. High-resolution Ultrasonic Thickness (UT) testing allows in-situ monitoring of both degradation mechanisms. When removed from the system mass loss resulting from corrosion and erosion may also be evaluated. Experimental testing at FIU implemented the SRNL coupon system in a 6.10 meter (20 foot) pipe loop system comprised of 50.8 mm (2 inch) and 76.2 mm (3 inch) pipe sections in order to replicate expected use cases at the sites. Operational conditions were emulated by pumping abrasive materials through the pipeline at full capacity and collecting measurements from the SRNL coupons. Initial testing was conducted by circulating water followed by a mixture of sand and water for uniform wear rates. Thickness changes and mass loss were measured, and the surface exposed to the process fluid was observed for visual evidence of characteristic wear patterns resulting from an erosive environment. The test matrix consisted of several hours of operation and using fine, medium and coarse grain sands. Test results were analyzed to check for all three parameters (mass loss/gain, thickness change and surface patters) which could provide estimates of the remaining useful life of the pipe sections. Thus, the research presents the findings of this evaluation of the SRNL coupons as a means for conducting high accuracy, cost effective in-situ analysis of pipeline and waste transfer systems for erosion and corrosion susceptibility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Paragenetic controls on CO 2 -fluid-rock interaction and weakening in a macroporous-dominated sandstone

The injection and storage of anthropogenic CO 2 in the subsurface is being deployed as a climate change mitigation tool; however, diagenetic-paragenetic heterogeneity in sandstone reservoirs often contributes to interval specific chemomechanical changes that affect injection and can increase leakage risk.In this paper we address reservoir heterogeneities’ impact on chemomechanical changes in a macroporous-dominated lithofacies of Morrow B sandstone, a formation containing several diagenetically-distinct hydraulic facies while undergoing enhanced oil recovery (EOR) and carbon dioxide (CO 2 ) sequestration. We performed three flow-through experiments using a CO 2 -charged or uncharged formation water combined with four indirect tensile strength tests per post-test sample. We then used the microstructure and paragenetic sequence to understand chemomechanical weakening with key observations as follows: dissolution of carbonates and feldspars changed porosity; increased permeability led to reclassifying each sample in a different hydraulic flow unit; decreased ultrasonic velocity; and did not lead to a loss of tensile strength. Tensile strength maintenance occurred due to the low abundance and minor dissolution of siderite, the stability of quartz, and the relative position of diagenetic ankerite within feldspar. This macroporous-dominated lithofacies is the primary reservoir for the Morrow B Sandstone, and is analogous to other porous sandstone reservoirs. It represents an end-member of a chemomechanically low-risk siliceous CO 2 sequestration and CO 2 -EOR reservoir.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗