Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image understanding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

An approach for broad molecular imaging of the root-soil interface via indirect matrix-assisted laser desorption/ionization mass spectrometry

Understanding of rhizospheric processes is limited by the need for imaging complex molecular transformations at relevant spatial scales within the root soil continuum. In this work, we demonstrate a method to enable this analysis by first extracting organic compounds from the rhizosphere onto a PVDF membrane while maintaining their 2D distribution. We then image the distribution of chemical compounds using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). This approach permitted us to visualize and identify compounds on the root surface and presumed root exudates in the rhizosphere. Within a 1.8 cm x 0.6 cm sampling area of a switchgrass rhizosphere, we could observe at least four chemically distinct zones. Using high performance Fourier transform ion cyclotron MS, we were able to accurately annotate numerous molecules co-localized to each of these zones.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Hurricane Imaging Radiometer (HIRAD): Instrument Status and Performance Predictions

The Hurricane Imaging Radiometer (HIRAD) is an innovative radiometer which offers new and unique remotely sensed observations of both extreme oceanic wind events and strong precipitation. It is based on the airborne Stepped Frequency Microwave Radiometer (SFMR) [Uhlhorn and Black, 2004]. The HIRAD instrument advances beyond the current nadir viewing SFMR to an equivalent wide-swath SFMR imager using passive microwave synthetic thinned aperture radiometer (STAR) technology [Ruf et al., 1988]. This sensor operates over 4-7 GHz, where the required tropical cyclone remote sensing physics has been validated by both SFMR and WindSat radiometer [Bettenhausen et al., 2006; Brown et al., 2006]. HIRAD incorporates a new and unique array antenna design along with several technologies successfully demonstrated by the Lightweight Rain Radiometer instrument [Ruf et al., 2002; Ruf and Principe, 2003]. HIRAD will be a compact, lightweight, low-power instrument with no moving parts that will produce wide-swath imagery of ocean winds and rain in hurricane conditions. Accurate observations of surface ocean vector winds (OVW) with high spatial and temporal resolution are required for understanding and predicting tropical cyclones. The Hurricane Imaging Radiometer (HIRAD) is an innovative architecture which offers new and unique remotely sensed observations of both extreme oceanic wind events and strong precipitation. It is based on the airborne Stepped Frequency Microwave Radiometer (SFMR), which is a proven remote sensing technique for observing tropical cyclone (TC) ocean surface wind speeds and rain rates. The proposed HIRAD instrument advances beyond the current nadir viewing SFMR to an equivalent wide-swath SFMR imager using passive microwave synthetic thinned aperture radiometer (STAR) technology combined with a a unique array antenna design. The overarching design concept of HIRAD is to combine the multi-frequency C-band observing strategy of the SFMR with STAR technology to produce a wide-swath imager. Single frequency STAR technology The Hurricane Imaging Radiometer (HIRAD) is an innovative radiometer which offers new and unique remotely sensed observations of both extreme oceanic wind events and strong precipitation. It is based on the airborne Stepped Frequency Microwave Radiometer (SFMR) [Uhlhorn and Black, 2004]. The HIRAD instrument advances beyond the current nadir viewing SFMR to an equivalent wide-swath SFMR imager using passive microwave synthetic thinned aperture radiometer (STAR) technology [Ruf et al., 1988]. This sensor operates over 4-7 GHz, where the required tropical cyclone remote sensing physics has been validated by both SFMR and WindSat radiometer [Bettenhausen et al., 2006; Brown et al., 2006]. HIRAD incorporates a new and unique array antenna design along with several technologies successfully demonstrated by the Lightweight Rain Radiometer instrument [Ruf et al., 2002; Ruf and Principe, 2003]. HIRAD will be a compact, lightweight, low-power instrument with no moving parts that will produce wide-swath imagery of ocean winds and rain in hurricane conditions. Accurate observations of surface ocean vector winds (OVW) with high spatial and temporal resolution are required for understanding and predicting tropical cyclones. The Hurricane Imaging Radiometer (HIRAD) is an innovative architecture which offers new and unique remotely sensed observations of both extreme oceanic wind events and strong precipitation. It is based on the airborne Stepped Frequency Microwave Radiometer (SFMR), which is a proven remote sensing technique for observing tropical cyclone (TC) ocean surface wind speeds and rain rates. The proposed HIRAD instrument advances beyond the current nadir viewing SFMR to an equivalent wide-swath SFMR imager using passive microwave synthetic thinned aperture radiometer (STAR) technology combined with a a unique array antenna design. The overarching design concept of HIRAD is to combine the multi-frequency C-banbserving strategy of the SFMR with STAR technology to produce a wide-swath imager. Single frequency STAR technology

Ruf, Christopher↗

Ultrafast, high resolution, phase contrast imaging of impact response with synchrotron radiation

Understanding the dynamic response of materials at extreme conditions requires diagnostics that can provide real-time, in situ, spatially resolved measurements on the nanosecond timescale. The development of methods such as phase contrast imaging (PCI) typically used at synchrotron sources offer unique opportunities to examine dynamic material response. In this work, we report ultrafast, high-resolution, dynamic PCI measurements of shock compressed materials with 3 {mu}m spatial resolution using a single 60 ps synchrotron X-ray bunch. These results firmly establish the use of PCI to examine dynamic phenomena at ns to {mu}s timescales.

36 MATERIALS SCIENCE↗

Mapping Agricultural Crops with AVIRIS Spectra in Washington State

Spectroscopy is used in the laboratory to measure the molecular components and concentrations of plant constituents to answer questions about the plant type, status, and health. Imaging spectrometers measure the upwelling spectral radiance above the Earth's surface as images. Ideally, imaging spectrometer data sets should be used to understand plant type, plant status, and health of plants in an agricultural setting. An Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data set was acquired over agricultural fields near Wallula, Washington on July 23rd, 1997. AVIRIS measures upwelling radiance spectra through 224 spectral channels with contiguous 10-nm sampling from 400 to 2500 run in the solar-reflected spectrum. The spectra are measured as images of 11 by up to 800 km with 20-m spatial resolution. The spectral images measured by AVIRIS represent the integrated signal resulting from: the solar irradiance; two way transmittance and scattering of the atmosphere; the absorptions and scattering of surface materials; as well as the spectral, radiometric and spatial response functions of AVIRIS. This paper presents initial research to derive properties of the agricultural fields near Wallula from the calibrated spectral images measured by AVIRIS near the top of the atmosphere.

Green, Robert O.↗

Mapping Agricultural Crops with AVIRIS Spectra in Washington State

Spectroscopy is used in the laboratory to measure the molecular components and concentrations of plant constituents to answer questions about the plant type, status, and health. Imaging spectrometers measure the upwelling spectral radiance above the Earth's surface as images. Ideally, imaging spectrometer data sets should be used to understand plant type, plant status, and health of plants in an agricultural setting. An Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data set was acquired over agricultural fields near Wallula, Washington on July 23rd, 1997. AVIRIS measures upwelling radiance spectra through 224 spectral channels with contiguous 10-nm sampling from 400 to 2500 nm in the solar-reflected spectrum. The spectra are measured as images of 11 by up to 800 km with 20-m spatial resolution. The spectral images measured by AVIRIS represent the integrated signal resulting from: the solar irradiance; two way transmittance and scattering of the atmosphere; the absorptions and scattering of surface materials; as well as the spectral, radiometric and spatial response functions of AVIRIS. This paper presents initial research to derive properties of the agricultural fields near Wallula from the calibrated spectral images measured by AVIRIS near the top of the atmosphere.

Green, Robert↗

Disentangling Radiographic Contributions

Presentation describes research program and goal to understand all large radiographic contributions for a given image and assess if quantitative predictions can be made once contributions are understood, with current focus understanding scintillator response.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interpretation of Dynamics Explorer far UV images of the quiet time thermosphere

A selected set of far ultra violet images of Earth have been analyzed quanitatively to establish their validity for studying thermospheric weather. The set of images chosen for the study was restricted to mostly geomagnetically quiet conditions in order to obtain a baseline understanding of the relationship between the observations and thermospheric phenomenology. The images included low to modrerate solar activity levels. A new model was developed to generate global dayglow images using first principles methods. The mass Spectrometer/incoherent scatter (MSIS-86) model was used to predict the thermospheric concentrations. The analyses of thermospheric images observed in the 123 to 160-nm nominal passband show that the spectral composition for observations on the projected earth disk is dominated by O I 130.4-nm radiation (85-90%), with concentrations from O I 135.6-nm and N2 Lyman-Birge-Hopefield (LBH) bands of about 5-8% each. The synthetic images reproduce the global features of the observed images rather well. Differences between the model and the data are attributed to real atmospheric effects, such as atomic oxygen depletions which are not well reproduced by the MSIS model when geomagnetic activity is elevated. The absoute values recorded were 38-54% higher than predicted. We attribute this discrepancy to low values of the solar extreme ultraviolet irradiances used in the model. Images obtained in the 136 to 165-nm nominal passband are a factor of 2.7 greater than the model. The excess signal observed is most likely due to a long wavelength tail in the instrument sensitivity which allowed Rayleigh scattered sunlight between 180and 250nm to be detected. The understanding of the Dynamics Explorer (DE 1) images gained by this study provides the basis for future work on the global response of the theremosphere to geomagnetic forcing.

Meier, R. R.↗

Quantifying Spatially Varying Blur in X-ray Radiographic Imaging Systems

Two goals of quantitative analysis of radiographic data from dynamic material experiments are to identify edge locations and infer material density. Understanding the systematic effect of blur of the imaging system through calibration imagery is the fist step to quantifying, modeling, and eventually mitigating its effect. If modeling geometry and assumptions can be expressed through operator transformations, this leads to natural modifications of the likelihood and prior in a Bayesian formulation of the inverse problem.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma response measurements of non-axisymmetric magnetic perturbations on DIII-D via soft x-ray imaging

Recent observations on DIII-D have advanced the understanding of plasma response to applied resonant magnetic perturbations (RMPs) in both H-mode and L-mode plasmas. Three distinct 3D features localized in minor radius are imaged via filtered soft x-ray emission: (i) the formation of lobes extending from the unperturbed separatrix in the X-point region at the plasma boundary, (ii) helical kink-like perturbations in the steep-gradient region inside the separatrix, and (iii) amplified islands in the core of a low-rotation L-mode plasma. In this study, these measurements are used to test and to validate plasma response models, which are crucial for providing predictive capability of edge-localized mode control. In particular, vacuum and two-fluid resistive magnetohydrodynamic(MHD) responses are tested in the regions of these measurements. At the plasma boundary in H-mode discharges with n = 3 RMPs applied, measurements compare well to vacuum-field calculations that predict lobe structures. Yet in the steep-gradient region, measurements agree better with calculations from the linear resistive two-fluid MHD code, M3D-C1. Relative to the vacuum fields, the resistive two-fluid MHD calculations show a reduction in the pitch-resonant components of the normal magnetic field (screening), and amplification of non-resonant components associated with ideal kink modes. However, the calculations still over-predict the amplitude of the measuredperturbation by a factor of 4. In a slowly rotating L-mode plasma with n = 1 RMPs, core islands are observed amplified from vacuum predictions. Finally, these results indicate that while the vacuum approach describes measurements in the edge region well, it is important to include effects of extended MHD in the pedestal and deeper in the plasma core.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Web-based, GPU-accelerated, Monte Carlo simulation and visualization of indirect radiation imaging detector performance

Purpose: Monte Carlo simulations play a vital role in the understanding of the fundamental limitations, design, and optimization of existing and emerging medical imaging systems. Efforts in this area have resulted in the development of a wide variety of open-source software packages. One such package, hybridMANTIS, uses a novel hybrid concept to model indirect scintillator detectors by balancing the computational load using dual CPU and graphics processing unit (GPU) processors, obtaining computational efficiency with reasonable accuracy. In this work, the authors describe two open-source visualization interfaces, webMANTIS and visualMANTIS to facilitate the setup of computational experiments via hybridMANTIS. Methods: The visualization tools visualMANTIS and webMANTIS enable the user to control simulation properties through a user interface. In the case of webMANTIS, control via a web browser allows access through mobile devices such as smartphones or tablets. webMANTIS acts as a server back-end and communicates with an NVIDIA GPU computing cluster that can support multiuser environments where users can execute different experiments in parallel. Results: The output consists of point response and pulse-height spectrum, and optical transport statistics generated by hybridMANTIS. The users can download the output images and statistics through a zip file for future reference. In addition, webMANTIS provides a visualization window that displays a few selected optical photon path as they get transported through the detector columns and allows the user to trace the history of the optical photons. Conclusions: The visualization tools visualMANTIS and webMANTIS provide features such as on the fly generation of pulse-height spectra and response functions for microcolumnar x-ray imagers while allowing users to save simulation parameters and results from prior experiments. The graphical interfaces simplify the simulation setup and allow the user to go directly from specifying input parameters to receiving visual feedback for the model predictions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical Navigation Algorithm Performance

There is a wide variety of optical navigation (OpNav) techniques that can be used to extract observables from images of natural bodies. Each of these techniques has a number of strengths and weaknesses and domains where they are most applicable. In this paper, we compare the performance of some of the most commonly used OpNav techniques across a variety of orbital regimes and a variety of body types through the use of synthetic images. Specifically, we consider the techniques of analytic model fitting, phase corrected moment estimation, limb-scanning, ellipsoid matching, and cross correlation using synthetic images of a tri-axial ellipsoid, the asteroid Bennu, and the comet 67P/Churyumov-Gerasimenko. For each technique, regime, and body, we examine the overall accuracy and the type of information available. The resulting information provides a useful tool for understanding which techniques are best suited for a given image, as well as for understanding the relative performance of each technique.

Wright, Cinnamon A.↗

EIC in the US: Status of the Project and Outlook of the 3D Nucleon Structure Program

The interior landscape of nucleons includes a strong-force driven sea of quarks, antiquarks and gluons, with a net surplus of a few ever-present valence quarks. In order to understand how the properties and structure of all forms of nuclear matter emerge from the dynamics of QCD, it is essential to precisely image the gluons and quarks, and to understand the role they and their interactions play in nucleons and nuclei. For this, a new accelerator facility is required, the Electron-Ion Collider, to match the valence quark studies of the upgraded Jefferson Lab. Such a future facility would be the world's first polarized electron-proton collider, and the world's first e-A collider. The science foreseen at and the status of such a future US-based polarized Electron-Ion Collider will be presented.

Ent, Rolf↗

Application of STEM characterization for investigating radiation effects in BCC Fe-based alloys

This paper provides a general overview of advanced scanning transmission electron microscopy (STEM) techniques used for characterization of irradiated BCC Fe-based alloys. Advanced STEM methods provide the high-resolution imaging and chemical analysis necessary to understand the irradiation response of BCC Fe-based alloys. The use of STEM with energy dispersive x-ray spectroscopy (EDX) for measurement of radiation-induced segregation (RIS) is described, with an illustrated example of RIS in proton- and self-ion irradiated T91. Aberration-corrected STEM-EDX for nanocluster/nanoparticle imaging and chemical analysis is also discussed, and examples are provided from ion-irradiated oxide dispersion strengthened (ODS) alloys. In conclusion, STEM techniques for void, cavity, and dislocation loop imaging are described, with examples from various BCC Fe-based alloys.

36 MATERIALS SCIENCE↗

Insight into 3D micro-CT data: exploring segmentation algorithms through performance metrics

Three-dimensional (3D) micro-tomography (µ-CT) has proven to be an important imaging modality in industry and scientific domains. Understanding the properties of material structure and behavior has produced many scientific advances. An important component of the 3D µ-CT pipeline is image partitioning (or image segmentation), a step that is used to separate various phases or components in an image. Image partitioning schemes require specific rules for different scientific fields, but a common strategy consists of devising metrics to quantify performance and accuracy. The present article proposes a set of protocols to systematically analyze and compare the results of unsupervised classification methods used for segmentation of synchrotron-based data. Additionally, the proposed dataflow for Materials Segmentation and Metrics (MSM) provides 3D micro-tomography image segmentation algorithms, such as statistical region merging (SRM), k-means algorithm and parallel Markov random field (PMRF), while offering different metrics to evaluate segmentation quality, confidence and conformity with standards. Both experimental and synthetic data are assessed, illustrating quantitative results through the MSM dashboard, which can return sample information such as media porosity and permeability. The main contributions of this work are: (i) to deliver tools to improve material design and quality control; (ii) to provide datasets for benchmarking and reproducibility; (iii) to yield good practices in the absence of standards or ground-truth for ceramic composite analysis.

97 MATHEMATICS AND COMPUTING↗

Dust aerosol retrieval results from MISR (multi-angle imaging spectro-radiometer)

Satellite measurements provide important tools for understanding the effect of mineral dust aerosols on past and present climate and climate predictions. Multi-angle instruments such as Multi-angle Imaging Spectro- Radiometer (MISR) provide independent constraints on aerosol properties based on their sensitivity to the shape of aerosol scattering phase functions. The current MISR operational retrieval algorithm (version 16 and higher) was modified by incorporating new non-spherical dust models that account for naturally occurring dust shapes and compositions. We present selected examples of MISR version 16 retrievals over AERONET sunphotometer land and ocean sites during the passage of dust fronts. Our analysis shows that during such events MISR retrieves Angstrom exponents characteristic of large particles, having little spectral variation in extinction over the MISR wavelength range (442, 550, 672 and 866 nm channels), as expected. The retrieved fraction of non-spherical particles is also very high. This quantity is not retrieved by satellite instruments having only nadir-viewing cameras. Our comparison of current (version 16) MISR-retrieved aerosol optical thickness (AOT) with AERONET instantaneous AOT shows better coverage and stronger correlations than when making identical comparisons with previous AOT retrievals (version 15). The MISR algorithm successful mixtures include a non-spherical dust component with high frequency in retrievals over dark water and slightly lower frequency over land. Selection frequencies of non-spherical dust models also decrease in dusty regions affected by pollution.

Multiangle Imaging Spectroradiometer (MISR)↗

A Deep Look Into the Future of Quantitative Imaging in Oncology: A Statement of Working Principles and Proposal for Change

The adoption of enterprise digital imaging, along with the development of quantitative imaging methods and the re-emergence of statistical learning, has opened the opportunity for more personalized cancer treatments through transformative data science research. In the last 5 years, accumulating evidence has indicated that noninvasive advanced imaging analytics (i.e., radiomics) can reveal key components of tumor phenotype for multiple lesions at multiple time points over the course of treatment. Many groups using homegrown software have extracted engineered and deep quantitative features on 3-dimensional medical images for better spatial and longitudinal understanding of tumor biology and for the prediction of diverse outcomes. These developments could augment patient stratification and prognostication, buttressing emerging targeted therapeutic approaches. Unfortunately, the rapid growth in popularity of this immature scientific discipline has resulted in many early publications that miss key information or use underpowered patient data sets, without production of generalizable results. Quantitative imaging research is complex, and key principles should be followed to realize its full potential. The fields of quantitative imaging and radiomics in particular require a renewed focus on optimal study design and reporting practices, standardization, interpretability, data sharing, and clinical trials. Standardization of image acquisition, feature calculation, and statistical analysis (i.e., machine learning) are required for the field to move forward. A new data-sharing paradigm enacted among open and diverse participants (medical institutions, vendors and associations) should be embraced for faster development and comprehensive clinical validation of imaging biomarkers. In this review and critique of the field, we propose working principles and fundamental changes to the current scientific approach, with the goal of high-impact research and development of actionable prediction models that will yield more meaningful applications of precision cancer medicine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Locating the atoms at the hard-soft interface of gold nanoparticles

Surface structure affects the growth, shape and properties of nanoparticles. In wet chemical syntheses, metal additives and surfactants are used to modify surfaces and guide nanocrystal growth. To understand this process, it is critical to understand how the surface structure, and hence its energy, is modified. However, measuring the type and arrangement of atoms at hard-soft interfaces on nanoscale surfaces, especially in the presence of surfactants, is extremely challenging. Here, we determine the atomic structure of the hard-soft interface in a metallic nanoparticle by developing low-dose imaging conditions in four-dimensional scanning transmission electron microscopy that are preferentially sensitive to surface adatoms. By revealing experimentally the copper additives and bromide surfactant counterion at the surface of a gold nanocuboid and quantifying their interatomic distances, our direct, low-dose imaging method provides atomic-level understanding of chemically sophisticated nanomaterial surface structures. These measurements of the atomic structure of the hard-soft interface provide the information necessary to understand and quantify surface chemistries and energies and their pivotal role in nanocrystal growth.

Li, Weilun [Monash University, Melbourne, VIC (Aus↗

Evaluating the extent of cell death in 3D high frequency ultrasound by registration with whole-mount tumor histopathology

Purpose: High frequency ultrasound imaging, 10-30 MHz, has the capability to assess tumor response to radiotherapy in mouse tumors as early as 24 h after treatment administration. The advantage of this technique is that the image contrast is generated by changes in the physical properties of dying cells. Therefore, a subject can be imaged before and multiple times during the treatment without the requirement of injecting specialized contrast agents. This study is motivated by a need to provide metrics of comparison between the volume and localization of cell death, assessed from histology, with the volume and localization of cell death surrogate, assessed as regions with increased echogeneity from ultrasound images. Methods: The mice were exposed to radiation doses of 2, 4, and 8 Gy. Ultrasound images were collected from each tumor before and 24 h after exposure to radiation using a broadband 25 MHz center frequency transducer. After radiotherapy, tumors exhibited hyperechoic regions in ultrasound images that corresponded to areas of cell death in histology. The ultrasound and histological images were rigidly registered. The tumors and regions of cell death were manually outlined on histological images. Similarly, the tumors and hyperechoic regions were outlined on the ultrasound images. Each set of contours was converted to a volumetric mesh in order to compare the volumes and the localization of cell death in histological and ultrasound images. Results: A shrinkage factor of 17{+-}2% was calculated from the difference in the tumor volumes evaluated from histological and ultrasound images. This was used to correct the tumor and cell death volumes assessed from histology. After this correction, the average absolute difference between the volume of cell death assessed from ultrasound and histological images was 11{+-}14% and the volume overlap was 70{+-}12%. Conclusions: The method provided metrics of comparison between the volume of cell death assessed from histology and that assessed from ultrasound images. It was applied here to evaluate the capability of ultrasound imaging to assess early tumor response to radiotherapy in mouse tumors. Similarly, it can be applied in the future to evaluate the capability of ultrasound imaging to assess early tumor response to other modalities of cancer treatment. The study contributes to an understanding of the capabilities and limitation of ultrasound imaging at noninvasively detecting cell death. This provides a foundation for future developments regarding the use of ultrasound in preclinical and clinical applications to adapt treatments based on tumor response to cancer therapy.

60 APPLIED LIFE SCIENCES↗