Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image charge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Charge-Injection-Device Performance in the High-Energy-Neutron Environment of Laser-Fusion Experiments

Charge-injection devices (CIDs) are being used to image x rays in laser-fusion experiments on the University of Rochester’s OMEGA Laser System. The CID cameras are routinely used up to the maximum neutron yields generated (~10^14 DT). The detectors are deployed in x-ray pinhole cameras and Kirkpatrick–Baez microscopes. The neutron fluences ranged from ~10^7 to ~10^9 neutrons/cm^2 and useful x-ray images were obtained even at the highest fluences. It is intended to use CID cameras at the National Ignition Facility (NIF) as a supporting means of recording x-ray images. The results of this work predict that x-ray images should be obtainable on the NIF at yields up to ~10^15, depending on distance and shielding.

Marshall, F J↗

The National Ignition Facility Neutron Imaging System

The National Ignition Facility (NIF) is scheduled to begin deuterium-tritium (DT) shots possibly in the next several years. One of the important diagnostics in understanding capsule behavior and to guide changes in Hohlraum illumination, capsule design, and geometry will be neutron imaging of both the primary 14 MeV neutrons and the lower-energy downscattered neutrons in the 6-13 MeV range. The neutron imaging system (NIS) described here, which we are currently building for use on NIF, uses a precisely aligned set of apertures near the target to form the neutron images on a segmented scintillator. The images are recorded on a gated, intensified charge coupled device. Although the aperture set may be as close as 20 cm to the target, the imaging camera system will be located at a distance of 28 m from the target. At 28 m the camera system is outside the NIF building. Because of the distance and shielding, the imager will be able to obtain images with little background noise. The imager will be capable of imaging downscattered neutrons from failed capsules with yields Y{sub n}>10{sup 14} neutrons. The shielding will also permit the NIS to function at neutron yields >10{sup 18}, which is in contrast to most other diagnostics that may not work at high neutron yields. The following describes the current NIF NIS design and compares the predicted performance with the NIF specifications that must be satisfied to generate images that can be interpreted to understand results of a particular shot. The current design, including the aperture, scintillator, camera system, and reconstruction methods, is briefly described. System modeling of the existing Omega NIS and comparison with the Omega data that guided the NIF design based on our Omega results is described. We will show NIS model calculations of the expected NIF images based on component evaluations at Omega. We will also compare the calculated NIF input images with those unfolded from the NIS images generated from our NIS numerical modeling code.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Next-Generation Photon Sources for Grand Challenges in Science and Energy

The next generation of sustainable energy technologies will revolve around transformational new materials and chemical processes that convert energy efficiently among photons, electrons, and chemical bonds. New materials that tap sunlight, store electricity, or make fuel from splitting water or recycling carbon dioxide will need to be much smarter and more functional than today's commodity-based energy materials. To control and catalyze chemical reactions or to convert a solar photon to an electron requires coordination of multiple steps, each carried out by customized materials and interfaces with designed nanoscale structures. Such advanced materials are not found in nature the way we find fossil fuels; they must be designed and fabricated to exacting standards, using principles revealed by basic science. Success in this endeavor requires probing, and ultimately controlling, the interactions among photons, electrons, and chemical bonds on their natural length and time scales. Control science - the application of knowledge at the frontier of science to control phenomena and create new functionality - realized through the next generation of ultraviolet and X-ray photon sources, has the potential to be transformational for the life sciences and information technology, as well as for sustainable energy. Current synchrotron-based light sources have revolutionized macromolecular crystallography. The insights thus obtained are largely in the domain of static structure. The opportunity is for next generation light sources to extend these insights to the control of dynamic phenomena through ultrafast pump-probe experiments, time-resolved coherent imaging, and high-resolution spectroscopic imaging. Similarly, control of spin and charge degrees of freedom in complex functional materials has the potential not only to reveal the fundamental mechanisms of high-temperature superconductivity, but also to lay the foundation for future generations of information science. This report identifies two aspects of energy science in which next-generation ultraviolet and X-ray light sources will have the deepest and broadest impact: (1) The temporal evolution of electrons, spins, atoms, and chemical reactions, down to the femtosecond time scale. (2) Spectroscopic and structural imaging of nano objects (or nanoscale regions of inhomogeneous materials) with nanometer spatial resolution and ultimate spectral resolution. The dual advances of temporal and spatial resolution promised by fourth-generation light sources ideally match the challenges of control science. Femtosecond time resolution has opened completely new territory where atomic motion can be followed in real time and electronic excitations and decay processes can be followed over time. Coherent imaging with short-wavelength radiation will make it possible to access the nanometer length scale, where intrinsic quantum behavior becomes dominant. Performing spectroscopy on individual nanometer-scale objects rather than on conglomerates will eliminate the blurring of the energy levels induced by particle size and shape distributions and reveal the energetics of single functional units. Energy resolution limited only by the uncertainty relation is enabled by these advances. Current storage-ring-based light sources and their incremental enhancements cannot meet the need for femtosecond time resolution, nanometer spatial resolution, intrinsic energy resolution, full coherence over energy ranges up to hard X-rays, and peak brilliance required to enable the new science outlined in this report. In fact, the new, unexplored territory is so expansive that no single currently imagined light source technology can fulfill the whole potential. Both technological and economic challenges require resolution as we move forward. For example, femtosecond time resolution and high peak brilliance are required for following chemical reactions in real time, but lower peak brilliance and high repetition rate are needed to avoid radiation damage in high-resolution spatial imaging and to avoid space-charge broadening in photoelectron spectroscopy and microscopy. But light sources alone are not enough. The photons produced by next-generation light sources must be measured by state-of-the-art experiments installed at fully equipped end stations. Sophisticated detectors with unprecedented spatial, temporal, and spectral resolution must be designed and created. The theory of ultrafast phenomena that have never before been observed must be developed and implemented. Enormous data sets of diffracted signals in reciprocal space and across wide energy ranges must be collected and analyzed in real time so that they can guide the ongoing experiments. These experimental challenges - end stations, detectors, sophisticated experiments, theory, and data handling - must be planned and provided for as part of the photon source.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Average charge and its structure dependence of fragment ions under irradiation of a thin carbon foil with a 1-MeV/atom C{sub 3}{sup +} cluster ion

The charge states of fragment ions were measured for 1-MeV/atom C{sub 3}{sup +} cluster ions penetrating a carbon foil of 2.4-{mu}g/cm{sup 2} thickness. Those ions were detected by event-by-event mode with a fluorescent screen detector monitored by a charge-coupled device camera. The detected ion signals were traced by Coulomb explosion imaging technique, which enables us to classify charge states of each fragment ion and spatial arrangements of aligned cluster ions after emerging from the foil. Using this technique, we found the reduction of the average charge per ion. We also found that (i) the measured average charges of the aligned fragment ions in a linear-chain arrangement are larger than those in a triangular arrangement, and (ii) the edge-position ions in a linear-chain arrangement have the average charges greater than the middle-position ion. These experimental results are well supported by a recent refined theory on the cluster average charge.

74 ATOMIC AND MOLECULAR PHYSICS↗

braggedgemodeling

braggedgemodeling (bem) is an open-source Python package for modeling neutron Bragg-edge imaging. It computes the wavelength-dependent total neutron cross-section of a material (coherent and incoherent elastic, coherent and incoherent inelastic scattering, and absorption) from its crystal structure, and implements the March-Dollase texture model and the Jorgensen peak profile, supporting quantitative analysis of energy-resolved neutron imaging data (phase, stress/strain, and texture). Published in the Journal of Open Source Software (2018).

Lin, Jiao [Oak Ridge National Laboratory (ORNL), O↗

Lateral Diffusion Estimation in Fully Depleted Thick CCD Using Flat Field Image Analysis

In thick fully depleted CCDs charge carrier transport from the back window to the gates is accompanied by charge diffusion. Lateral diffusion smooths out density variations of the incoming photon flux by redistributing charges spatially. This creates short range positive correlations in recorded amplitudes. Pixel-to-pixel amplitude variations can also be caused by pixel size and quantum efficiency variations. Pixel size variations result in short range negative correlations. Our study shows that the characteristic diffusion width can be extracted from flat field data. The study was performed on fully depleted, thick CCDs produced in a technology study for the Large Synoptic Survey Telescope (LSST). Data were taken in the laboratory at bias voltages between -5 and -40 V. To increase statistical accuracy, images taken in identical conditions were co-added after base line subtraction and master files were produced. A flat field image simulator was developed for statistical comparison of simulated and measured images. Results on diffusion, pixel response variations, data features, analysis and modeling techniques are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An imaging evaluation of the simultaneously integrated boost breast radiotherapy technique

To evaluate in-field megavoltage (MV) imaging of simultaneously integrated boost (SIB) breast fields to determine its feasibility in treatment verification for the SIB breast radiotherapy technique, and to assess whether the current-imaging protocol and treatment margins are sufficient. For nine patients undergoing SIB breast radiotherapy, in-field MV images of the SIB fields were acquired on days that regular treatment verification imaging was performed. The in-field images were matched offline according to the scar wire on digitally reconstructed radiographs. The offline image correction results were then applied to a margin recipe formula to calculate safe margins that account for random and systematic uncertainties in the position of the boost volume when an offline correction protocol has been applied. After offline assessment of the acquired images, 96% were within the tolerance set in the current department-imaging protocol. Retrospectively performing the maximum position deviations on the Eclipse™ treatment planning system demonstrated that the clinical target volume (CTV) boost received a minimum dose difference of 0.4% and a maximum dose difference of 1.4% less than planned. Furthermore, applying our results to the Van Herk margin formula to ensure that 90% of patients receive 95% of the prescribed dose, the calculated CTV margins were comparable to the current departmental procedure used. Based on the in-field boost images acquired and the feasible application of these results to the margin formula the current CTV-planning target volume margins used are appropriate for the accurate treatment of the SIB boost volume without additional imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Charge collection microscopy of in-situ switchable PRAM line cells in a scanning electron microscope: Technique development and unique observations

An imaging method has been developed based on charge collection in a scanning electron microscope (SEM) that allows discrimination between the amorphous and crystalline states of Phase-change Random Access Memory (PRAM) line cells. During imaging, the cells are electrically connected and can be switched between the states and the resistance can be measured. This allows for electrical characterization of the line cells in-situ in the SEM. Details on sample and measurement system requirements are provided which turned out to be crucial for the successful development of this method. Results show that the amorphous or crystalline state of the line cells can be readily discerned, but the spatial resolution is relatively poor. Nevertheless, it is still possible to estimate the length of the amorphous mark, and also for the first time, we could directly observe the shift of the amorphous mark from one side of the line cell to the other side when the polarity of the applied (50 ns) RESET pulse was reversed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge changing cross-sections for 300 A MeV Fe{sup 26+} ion beam in Al target

In the present study, total and partial charge changing cross-sections of 300 A MeV Fe{sup 26+} ion beam in Al target were measured. The CR39 nuclear track detectors were used to identify the incident charged particles and their fragments using an automated image analyzer system installed with Leica QWin Plus software. The measured value of the total charge changing cross-section is {sigma}{sub tot}= (1663 {+-} 236) mb.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Energetic neutral atom image of a storm-time ring current

Energetic neutral atom (ENA) images of a storm-time ring current produced from direct measurements and model simulations are presented and analyzed. An ENA image of the storm-time ring current was obtained with the Medium Energy Particles Instrument (MEPI) mounted on ISEE 1 on September 29, 1978, and a zero-order model of the ring current ion was employed to simulate the ENA image. The simulated instrument response is compared with actual ENA measurements. It is observed that the spatial distribution of singly charged ions detected from the ENA images displays equatorial midnight/noon asymmetry in differential ion intensity with a midnight/noon ratio of greater than or equal to 20:1; peak ion fluxs, H(+) and O(+), in the midnight sector are greater than 10 to the 6th/(sq cm s sr keV); and ENA fluxes from the brighter areas of the image exceed greater than 1000/(sq cm s sr keV). It is noted that the ENA image from MEPI data correlates with the morphology of the simulated response of MEPI calculated from the model.

Roelof, Edmond C.↗

The Dark Side of Pluto

During its departure from Pluto, New Horizons used its LORRI camera to image a portion of Pluto's southern hemisphere that was in a decades-long seasonal winter darkness, but still very faintly illuminated by sunlight reflected by Charon. Recovery of this faint signal was technically challenging. The bright ring of sunlight forward-scattered by haze in the Plutonian atmosphere encircling the nightside hemisphere was severely overexposed, defeating the standard smeared-charge removal required for LORRI images. Reconstruction of the overexposed portions of the raw images, however, allowed adequate corrections to be accomplished. The small solar elongation of Pluto during the departure phase also generated a complex scattered-sunlight background in the images that was three orders of magnitude stronger than the estimated Charon-light flux (the Charon-light flux is similar to the flux of moonlight on Earth a few days before first quarter). A model background image was constructed for each Pluto image based on principal component analysis applied to an ensemble of scattered-sunlight images taken at identical Sun−spacecraft geometry to the Pluto images. The recovered Charon-light image revealed a high-albedo region in the southern hemisphere. We argue that this may be a regional deposit of N2 or CH4 ice. The Charon-light image also shows that the south polar region currently has markedly lower albedo than the north polar region of Pluto, which may reflect the sublimation of N2 ice or the deposition of haze particulates during the recent southern summer.

Pluto↗

Study of the surface heterogeneity of topographic and electric nature by atomic force microscopy by the example of triglycine sulfate

Triglycine sulfate crystals with an ideal (010) cleavage plane are used as model objects to reveal problems in interpreting atomic force microscopy (AFM) images of surfaces with nonuniform charge distribution. Specific microrelief features of two types are found: lenslike formations with different contrast and rounded protrusions/valleys of different size but fixed height. An analysis of their evolution with a change in temperature and under an electric field and mechanical impacts has made it possible to separate relief elements from the crystal domain structure. The interpretation proposed is confirmed by the multimode AFM data. The specific features of the images of dynamic domains and aged domains (which cannot undergo polarization reversal) are studied. The domain-wall width found in the AFM measurements depends on the technique used and the specificity of probe-surface interaction; it varies from 9 to 2000 nm. The most reliable data on the domain-wall width in triglycine sulfate crystals are provided by piezoelectric force microscopy, according to which the wall width does not exceed 30 nm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On the system stability and calibration of the image plate/scanner system for plasma diagnosis at the National Ignition Facility

At the National Ignition Facility (NIF), storage phosphor image plates (IP) are used extensively for recording x-rays, charged particles, and neutrons. For x-ray imaging and spectroscopy, absolute and relative calibrations are important for extracting plasma information from the diagnostics. We use Fuji MS, SR, and TR image plates that have been cut to fit custom diagnostic envelopes. The image plates are scanned on a General Electric FLA 7000 IP flying spot scanner. Calibrations for sensitivity, spatial scale, and temperature dependent fade are applied. During a set of recent calibrations, we noticed large shifts in the absolute calibration of the image plate system. The possible source of these shifts is discussed. We discuss scanner stability and a method for calibration. We discuss the fade and temperature effects of the image plates and how this correction is applied within the NIF environment. Here, we also compare our NIF GE FLA 7000 IP scanner with a new General Electric Amersham Typhoon IP scanner.

47 OTHER INSTRUMENTATION↗

Imaging viscous flow of the Dirac fluid in graphene

The electron–hole plasma in charge-neutral graphene is predicted to realize a quantum critical system in which electrical transport features a universal hydrodynamic description, even at room temperature. This quantum critical ‘Dirac fluid’ is expected to have a shear viscosity close to a minimum bound, with an interparticle scattering rate saturating1 at the Planckian time, the shortest possible timescale for particles to relax. Although electrical transport measurements at finite carrier density are consistent with hydrodynamic electron flow in graphene a clear demonstration of viscous flow at the charge-neutrality point remains elusive. In this work, we directly image viscous Dirac fluid flow in graphene at room temperature by measuring the associated stray magnetic field. Nanoscale magnetic imaging is performed using quantum spin magnetometers realized with nitrogen vacancy centres in diamond. Scanning single-spin and wide-field magnetometry reveal a parabolic Poiseuille profile for electron flow in a high-mobility graphene channel near the charge-neutrality point, establishing the viscous transport of the Dirac fluid. This measurement is in contrast to the conventional uniform flow profile imaged in a metallic conductor and also in a low-mobility graphene channel. Furthermore, via combined imaging and transport measurements, we obtain viscosity and scattering rates, and observe that these quantities are comparable to the universal values expected at quantum criticality. This finding establishes a nearly ideal electron fluid in charge-neutral, high-mobility graphene at room temperature4. Our results will enable the study of hydrodynamic transport in quantum critical fluids relevant to strongly correlated electrons in high-temperature superconductors9. This work also highlights the capability of quantum spin magnetometers to probe correlated electronic phenomena at the nanoscale.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Virtual anode effect in the propagation of positive streamers

Experiments made in a parallel-plate arrangement, where one of the plates is the ground plane and the other a positively charged dielectric sheet, show that at low air pressure the dielectric injects streamers onto the surrounding air. The similarities and differences between the streamers thus produced and those emitted from electrodes are discussed. The streamers here obtained were found to have diameters and speeds that are clearly dependent on pressure. Often the streamers were seen to decelerate markedly to the point of coming to a complete stop and on occasions even returning back to the dielectric they came from. The deceleration and the reflection of the streamers are attributed to a virtual anode created by the electrostatic image of the head's charge behind the ground plane. Field calculations performed corroborate this hypothesis. Through the use of an equation of motion of the positive head, it is then possible to obtain an estimate of the magnitude of its charge. The charge thus obtained was found to be in the 2.5–26 nC range.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cell-Detection Technique for Automated Patch Clamping

A unique and customizable machinevision and image-data-processing technique has been developed for use in automated identification of cells that are optimal for patch clamping. [Patch clamping (in which patch electrodes are pressed against cell membranes) is an electrophysiological technique widely applied for the study of ion channels, and of membrane proteins that regulate the flow of ions across the membranes. Patch clamping is used in many biological research fields such as neurobiology, pharmacology, and molecular biology.] While there exist several hardware techniques for automated patch clamping of cells, very few of those techniques incorporate machine vision for locating cells that are ideal subjects for patch clamping. In contrast, the present technique is embodied in a machine-vision algorithm that, in practical application, enables the user to identify good and bad cells for patch clamping in an image captured by a charge-coupled-device (CCD) camera attached to a microscope, within a processing time of one second. Hence, the present technique can save time, thereby increasing efficiency and reducing cost. The present technique involves the utilization of cell-feature metrics to accurately make decisions on the degree to which individual cells are "good" or "bad" candidates for patch clamping. These metrics include position coordinates (x,y) in the image plane, major-axis length, minor-axis length, area, elongation, roundness, smoothness, angle of orientation, and degree of inclusion in the field of view. The present technique does not require any special hardware beyond commercially available, off-the-shelf patch-clamping hardware: A standard patchclamping microscope system with an attached CCD camera, a personal computer with an imagedata- processing board, and some experience in utilizing imagedata- processing software are all that are needed. A cell image is first captured by the microscope CCD camera and image-data-processing board, then the image data are analyzed by software that implements the present machine-vision technique. This analysis results in the identification of cells that are "good" candidates for patch clamping (see figure). Once a "good" cell is identified, a patch clamp can be effected by an automated patchclamping apparatus or by a human operator. This technique has been shown to enable reliable identification of "good" and "bad" candidate cells for patch clamping. The ultimate goal in further development of this technique is to combine artificial-intelligence processing with instrumentation and controls in order to produce a complete "turnkey" automated patch-clamping system capable of accurately and reliably patch clamping cells with a minimum intervention by a human operator. Moreover, this technique can be adapted to virtually any cellular-analysis procedure that includes repetitive operation of microscope hardware by a human.

McDowell, Mark↗

Optical Recognition And Tracking Of Objects

Separate objects moving independently tracked simultaneously. System uses coherent optical techniques to obtain correlation between each object and reference image. Moving objects monitored by charge-coupled-device television camera, output fed to liquid-crystal television (LCTV) display. Acting as spatial light modulator, LCTV impresses images of moving objects on collimated laser beam. Beam spatially low-pass filtered to remove high-spatial-frequency television grid pattern.

Chao, Tien-Hsin↗

Development of a cold-neutron imaging detector based on thick gaseous electron multiplier

We present the results of our recent studies on a cold-neutron imaging detector prototype based on THick Gaseous Electron Multiplier (THGEM). The detector consists of a thin Boron layer, for neutron-to-charged particle conversion, coupled to two THGEM electrodes in cascade for charge amplification and a position-sensitive charge-readout anode. The detector operates in Ne/(5%)CF{sub 4}, at atmospheric pressure, in a stable condition at a gain of around 10{sup 4}. Due to the geometrical structure of the detector elements (THGEM geometry and charge read-out anode), the image of detector active area shows a large inhomogeneity, corrected using a dedicated flat-filed correction algorithm. The prototype provides a detection efficiency of 5% and an effective spatial resolution of the order of 1.3 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗