Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high frequency testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Robust Optimization Design Algorithm for High-Frequency TWTs

Traveling-wave tubes (TWTs), such as the Ka-band (26-GHz) model recently developed for the Lunar Reconnaissance Orbiter, are essential as communication amplifiers in spacecraft for virtually all near- and deep-space missions. This innovation is a computational design algorithm that, for the first time, optimizes the efficiency and output power of a TWT while taking into account the effects of dimensional tolerance variations. Because they are primary power consumers and power generation is very expensive in space, much effort has been exerted over the last 30 years to increase the power efficiency of TWTs. However, at frequencies higher than about 60 GHz, efficiencies of TWTs are still quite low. A major reason is that at higher frequencies, dimensional tolerance variations from conventional micromachining techniques become relatively large with respect to the circuit dimensions. When this is the case, conventional design- optimization procedures, which ignore dimensional variations, provide inaccurate designs for which the actual amplifier performance substantially under-performs that of the design. Thus, this new, robust TWT optimization design algorithm was created to take account of and ameliorate the deleterious effects of dimensional variations and to increase efficiency, power, and yield of high-frequency TWTs. This design algorithm can help extend the use of TWTs into the terahertz frequency regime of 300-3000 GHz. Currently, these frequencies are under-utilized because of the lack of efficient amplifiers, thus this regime is known as the "terahertz gap." The development of an efficient terahertz TWT amplifier could enable breakthrough applications in space science molecular spectroscopy, remote sensing, nondestructive testing, high-resolution "through-the-wall" imaging, biomedical imaging, and detection of explosives and toxic biochemical agents.

Wilson, Jeffrey D.↗

A 96% Alumina based Packaging System for 500°C Test of SiC Integrated Circuits

With the development of silicon carbide (SiC) sensors and electronic devices for operation at 500°C, compatible packaging technologies are needed for long term high temperature test and deployment of these sensors and electronic devices. 96% Al2O3 ceramic is an excellent electrically insulating material with acceptable dielectric constant and low dielectric loss over wide temperature and frequency ranges. This paper presents a packaging system for low power integrated circuits including a prototype 8-I/O chip-level package and printed circuit board (PCB) based on 96% Al2O3 ceramic substrates and Au thick-film metallization for 500°C applications. The details related to designs of packages and PCBs, packaging materials, and specific packaging step recipes including wire - bonding and die-attach, are presented. Some test results of this prototype packaging approach applied to SiC integrated circuits at 500oC are reviewed.

high temperature↗

VHF Ranging and Position Fixing Experiment Using ATS Satellites: Final Report on Phases 1 and 2, 25 November 1968 - 1 May 1971

The testing program with the ATS-1 and ATS-3 spacecraft showed that geostationary satellites can provide superior communications and position surveillance for mobile craft. Inexpensive modifications to conventional mobile communications equipment aboard the craft can provide reliable, high quality voice and digital communications with distant ground stations and other vehicles, and automatic surveillance of the positions of all the craft by a ground facility. The tests also demonstrated the location and automatic readout of remote data collection platforms. Frequency modulation signals with the narrow audio and radio frequency bandwidths of terrestrial mobile radio communications were relayed through the VHF transponders of the geostationary satellites. The voice and digital communications were far superior in reliability and quality to long-distance mobile communications by other means. It was shown that one satellite can provide nearly uniform high quality performance over approximately one-third of the earth's surface. Position fixes by range measurement from the two satellites were accurate to approximately one nautical mile, except near the equator and the poles.

Source record↗

A New Forced Oscillation Capability for the Transonic Dynamics Tunnel

A new forced oscillation system has been installed and tested at NASA Langley Research Center's Transonic Dynamics Tunnel (TDT). The system is known as the Oscillating Turntable (OTT) and has been designed for the purpose of oscillating, large semispan models in pitch at frequencies up to 40 Hz to acquire high-quality unsteady pressure and loads data. Precisely controlled motions of a wind-tunnel model on the OTT can yield unsteady aerodynamic phenomena associated with flutter, limit cycle oscillations, shock dynamics, and non-linear aerodynamic effects on many vehicle configurations. This paper will discuss general design and components of the OTT and will present test data from performance testing and from research tests on two rigid semispan wind-tunnel models. The research tests were designed to challenge the OTT over a wide range of operating conditions while acquiring unsteady pressure data on a small rectangular supercritical wing and a large supersonic transport wing. These results will be presented to illustrate the performance capabilities, consistency of oscillations, and usefulness of the OTT as a research tool.

Piatak, David J.↗

Application of the Pseudo Wigner-Ville Distribution to the Measurement of the Dispersion of Lamb Modes in Graphite/Epoxy Plates

Acoustic waves propagate in thin plates as guided or Lamb modes. The velocities of these modes are dispersive in that they depend not only on the material elastic properties and density, but also on the frequency. Accurate characterization of Lamb wave dispersion is important in many acoustic based nondestructive evaluation techniques. It is necessary for ultrasonic measurements in thin plates to determine elastic properties and for flaw detection and localization. In acoustic emission (AE) testing, if not taken into account, highly dispersive Lamb mode propagation can lead to large errors in source location. In this study, the pseudo Wigner-Ville distribution (PWVD) was used for measurement of group velocity dispersion of Lamb waves in a unidirectional graphite/epoxy (AS4/3502) laminate. The PWVD is one of a number of transforms which provide a time-frequency representation of a digitized time series. Broad band acoustic waves were generated by a pencil lead fracture (Hsu-Neilsen source) and were detected with broad band ultrasonic transducers. The arrival times for the lowest order symmetric (S(sub 0)) and antisymmetric (A(sub 0)) Lamb modes were determined from measurements of the time at which the respective peak amplitudes occurred in the PWVD. Measurements were made at several source-to-detector distances and a least squares fit used to calculate the velocity. Results are presented for propagation along, and perpendicular to, the fiber direction. Theoretical dispersion curves were also calculated and a comparison between theory and experiment demonstrates good agreement.

Prosser, W. H.↗

Design considerations for a Space Shuttle Main Engine turbine blade made of single crystal material

Nonlinear finite-element structural analyses were performed on the first stage high-pressure fuel turbopump blade of the Space Shuttle Main Engine. The analyses examined the structural response and the dynamic characteristics at typical operating conditions. Single crystal material PWA-1480 was considered for the analyses. Structural response and the blade natural frequencies with respect to the crystal orientation were investigated. The analyses were conducted based on typical test stand engine cycle. Influence of combined thermal, aerodynamic, and centrifugal loadings was considered. Results obtained showed that the single crystal secondary orientation effects on the maximum principal stresses are not highly significant.

Abdul-Aziz, A.↗

The Dielectric Constant at P-Band for Salinity from 0 to 150 pss

Measurements have been made at P-band (0.707 GHz) to construct a model for the dielectric constant of sea water and extend the model for the dielectric constant to high salinity (50-150 pss). The measurements are part of research to develop a model for the dielectric constant suitable for future wide-bandwidth remote sensing of salinity and for application to water bodies such as the Great Salt Lake with salinity significantly above that found in the open ocean. Measurements have been made at temperatures from 2 to 30 °C and salinity from 0 to 138 pss. The data have been fit to a Debye model for the dielectric constant with a single resonance as has been employed at L-band (1.413 GHz) where remote sensing of salinity is currently done. Comparison with contemporary models developed from data at L-band indicates that the L-band model and new P-band model do well at both frequencies for salinity less than 50 pss but at higher values of salinity the L-band models diverge from the data. The data has also been used to test at high salinity the mathematical relationship between salinity and conductivity which is the basis for the practical salinity scale (pss).

Dielectric Constant↗

Effects of head-down bed rest on complex heart rate variability: Response to LBNP testing

Head-down bed rest is used to model physiological changes during spaceflight. We postulated that bed rest would decrease the degree of complex physiological heart rate variability. We analyzed continuous heart rate data from digitized Holter recordings in eight healthy female volunteers (age 28-34 yr) who underwent a 13-day 6 deg head-down bed rest study with serial lower body negative pressure (LBNP) trials. Heart rate variability was measured on a 4-min data sets using conventional time and frequency domain measures as well as with a new measure of signal 'complexity' (approximate entropy). Data were obtained pre-bed rest (control), during bed rest (day 4 and day 9 or 11), and 2 days post-bed rest (recovery). Tolerance to LBNP was significantly reduced on both bed rest days vs. pre-bed rest. Heart rate variability was assessed at peak LBNP. Heart rate approximate entropy was significantly decreased at day 4 and day 9 or 11, returning toward normal during recovery. Heart rate standard deviation and the ratio of high- to low-power frequency did not change significantly. We conclude that short-term bed rest is associated with a decrease in the complex variability of heart rate during LBNP testing in healthy young adult women. Measurement of heart rate complexity, using a method derived from nonlinear dynamics ('chaos theory'), may provide a sensitive marker of this loss of physiological variability, complementing conventional time and frequency domain statistical measures.

Goldberger, Ary L.↗

A sophisticated, multi-channel data acquisition and processing system for high frequency noise research

A sophisticated, multi-channel computerized data acquisition and processing system was developed at the NASA LeRC for use in noise experiments. This technology, which is available for transfer to industry, provides a convenient, cost-effective alternative to analog tape recording for high frequency acoustic measurements. This system provides 32-channel acquisition of microphone signals with an analysis bandwidth up to 100 kHz per channel. Cost was minimized through the use of off-the-shelf components. Requirements to allow for future expansion were met by choosing equipment which adheres to established industry standards for hardware and software. Data processing capabilities include narrow band and 1/3 octave spectral analysis, compensation for microphone frequency response/directivity, and correction of acoustic data to standard day conditions. The system was used successfully in a major wind tunnel test program at NASA LeRC to acquire and analyze jet noise data in support of the High Speed Civil Transport (HSCT) program.

Hall, David G.↗

Three-Dimensional Application of DAMAS Methodology for Aeroacoustic Noise Source Definition

At the 2004 AIAA/CEAS Aeroacoustic Conference, a breakthrough in acoustic microphone array technology was reported by the authors. A Deconvolution Approach for the Mapping of Acoustic Sources (DAMAS) was developed which decouples the array design and processing influence from the noise being measured, using a simple and robust algorithm. For several prior airframe noise studies, it was shown to permit an unambiguous and accurate determination of acoustic source position and strength. As a follow-on effort, this paper examines the technique for three-dimensional (3D) applications. First, the beamforming ability for arrays, of different size and design, to focus longitudinally and laterally is examined for a range of source positions and frequency. Advantage is found for larger array designs with higher density microphone distributions towards the center. After defining a 3D grid generalized with respect to the array s beamforming characteristics, DAMAS is employed in simulated and experimental noise test cases. It is found that spatial resolution is much less sharp in the longitudinal direction in front of the array compared to side-to-side lateral resolution. 3D DAMAS becomes useful for sufficiently large arrays at sufficiently high frequency. But, such can be a challenge to computational capabilities, with regard to the required expanse and number of grid points. Also, larger arrays can strain basic physical modeling assumptions that DAMAS and all traditional array methodologies use. An important experimental result is that turbulent shear layers can negatively impact attainable beamforming resolution. Still, the usefulness of 3D DAMAS is demonstrated by the measurement of landing gear noise source distributions in a difficult hard-wall wind tunnel environment.

Brooks, Thomas F.↗

Non-Intrusive Cable Tester

A cable tester is described for low frequency testing of a cable for faults. The tester allows for testing a cable beyond a point where a signal conditioner is installed, minimizing the number of connections which have to be disconnected. A magnetic pickup coil is described for detecting a test signal injected into the cable. A narrow bandpass filter is described for increasing detection of the test signal. The bandpass filter reduces noise so that a high gain amplifier provided for detecting a test signal is not completely saturate by noise. To further increase the accuracy of the cable tester, processing gain is achieved by comparing the signal from the amplifier with at least one reference signal emulating the low frequency input signal injected into the cable. Different processing techniques are described evaluating a detected signal.

Medelius, Pedro J.↗

Evaluation of a stall-flutter spring-damper pushrod in the rotating control system of a CH-54B helicopter

Results of a design and flight test program conducted to define the effect of rotating pushrod damping on stall-flutter induced control loads are presented. The CH-54B helicopter was chosen as the test aircraft because it exhibited stall induced control loads. Damping was introduced into the CH-54B control system by replacing the standard pushrod with spring-damper assemblies. Design features of the spring-damper are described and the results of a dynamic analysis are shown which define the pushrod stiffness and damping requirements. Flight test measurements taken at 47,000 lb gross weight with and without the damper are presented. The results indicate that the spring-damper pushrods reduced high frequency, stall-induced rotating control loads by almost 50%. Fixed system control loads were reduced by 40%. Handling qualities in stall were unchanged, as expected.

Nettles, W. E.↗

Some experimental results on the L-star instability of metallized composite propellants

Experimental results are reported on the L-star instability characteristics of three AP/composite propellants. The metal content of the propellants is 2, 16, and 16%. Chuffing, bulk mode oscillations, and time-independent combustion are observed with all three of these propellants. The stability boundary, defined as the boundary between time-independent and unstable combustion, is found to be well defined for two of the propellants in agreement with recognized trends available in the literature on other propellants. The frequency of bulk mode oscillations is presented as a function of the chamber characteristic length. One of the propellants tested has shown bulk mode instability at as high a pressure as 217 psia.

Kumar, R. N.↗

A study of the use of vibration and stress wave sensing for the detection of bearing failure

Results from an experimental study of vibrations and stress waves emitted from ball bearings are presented. Fatique tests were run with both high quality bearings and man faulted bearings, all of one size. Tests were instrumented with different sensors to detect the noises from 10 Hz to 1 MHz. Frequency spectrum plots are presented. The modulation characteristics of the ultrasonic noises were analyzed, and acoustic emission type measurements were conducted. Results are presented which show that there are usable acoustic signal levels even beyond 500 KHz. These signal levels are modulated by a low frequency carrier which is a function of the stress loading and acoustic transmissibility. The results were correlated to fault size in the bearings. The correlation shows that the sensor used for signals from 100 KHz to 1 MHz gave the best sensitivity and detected the generation of very small spalls or pits.

Ensor, L. C.↗

Pulse-width-modulated attenuator for AGC

Automatic-gain-control (AGC) circuit regulates gain of intermediate-frequency and radio-frequency signals over wide dynamic range with high linearity and very low phase shift. Device has potential uses in radio and television receivers, signal distribution systems, and test and measurement instruments.

Macconnell, J. W.↗

Plume RF interference calculations for space shuttle

During a static ground test of a full-scale SRM, measurements of attenuation of the UHF 416.5 MHz Range Safety Signal, the VHF voice link (230 MHz), and of S-band (c. 2.2. GHz) communications links were undertaken. Analyses of these results indicate that measurable attenuation did occur at all test frequencies. The measured attenuation levels are compared with a simple model in which the received signal is identified as that diffracted about the edge of the highly absorbing plume and the signal level in the shadow zone is evaluated using the formula for diffraction at a straight edge. The comparison is satisfactory at VHF and UHF frequencies, and slightly less so at S-band. Reasons for the discrepancies found at higher frequencies are discussed. A revised procedure which appears to relieve the accuracy problem was developed. This procedure is discussed along with applications to high altitude SRM plume attenuation.

Boynton, F. P.↗

A 6 degree-of-freedom Lorentz force vibration isolator with nonlinear controller

This program demonstrated the technical feasibility of constructing large-stroke magnetic suspensions that can meet the active vibration isolation requirements of Space Station. These requirements include: (1) strokes over 1 cm in all directions, (2) actuator bandwidths over 100 Hz, (3) isolator roll-off frequencies below 10(exp -2) Hertz, and (4) force capability over 1 Newton in all axes. The 100 Hz actuator bandwidth allows the suspension to reject any direct force disturbances that act on the microgravity experiment, for example forces created by cable connections. The low isolator roll-off frequency and large stroke allow the magnetic suspension to isolate the microgravity experiment from Space Station vibrations above the roll-off frequency. The capability to meet these requirements was demonstrated by designing, constructing and testing a six-degree-of-freedom, prototype magnetic suspension system that featured high-performance, Lorentz-force actuators and full multi-input, multi-output control. This prototype suspension is designed to isolate large orbiter locker experiments under typical spacecraft constraints of size, weight, and power. Suspension in the full six-degrees-of-freedom was successfully demonstrated in this program while using a gravity-force unload mechanism to simulate a space environment. The prototype isolator is capable of space-based isolation service with relatively minor modification. The use of advanced, nonlinear control algorithms were investigated on a specially designed single-degree-of-freedom testbed. This low acceleration test facility simulates the Space Station vibration isolation problem in a single horizontal axis with low-friction, air-slide support. This allowed testing at the desired microgravity levels, without the gravity bias effects that are seen in a full six-degrees-of-freedom suspension. Precision components were used to reduce residual accelerations to microgravity levels so that the effects of sensor, actuator, and electronic noise could be evaluated. During the Phase 2 program, this testbed was used to demonstrate the advantages of nonlinear control algorithms to provide increased vibration isolation performance.

Fenn, Ralph↗

On the stability analysis of approximate factorization methods for 3D Euler and Navier-Stokes equations

The convergence characteristics of various approximate factorizations for the 3D Euler and Navier-Stokes equations are examined using the von-Neumann stability analysis method. Three upwind-difference based factorizations and several central-difference based factorizations are considered for the Euler equations. In the upwind factorizations both the flux-vector splitting methods of Steger and Warming and van Leer are considered. Analysis of the Navier-Stokes equations is performed only on the Beam and Warming central-difference scheme. The range of CFL numbers over which each factorization is stable is presented for one-, two-, and three-dimensional flow. Also presented for each factorization is the CFL number at which the maximum eigenvalue is minimized, for all Fourier components, as well as for the high frequency range only. The latter is useful for predicting the effectiveness of multigrid procedures with these schemes as smoothers. Further, local mode analysis is performed to test the suitability of using a uniform flow field in the stability analysis. Some inconsistencies in the results from previous analyses are resolved.

Demuren, A. O.↗