Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Flow boiling with enhancement devices for cold plate coolant channel design

Future space exploration and commercialization will require more efficient heat rejection systems. For the required heat transfer rates, such systems must use advanced heat transfer techniques. Forced two phase flow boiling heat transfer with enhancements falls in this category. However, moderate to high quality two phase systems tend to require higher pressure losses. This report is divided into two major parts: (1) Multidimensional wall temperature measurement and heat transfer enhancement for top heated horizontal channels with flow boiling; and (2) Improved analytical heat transfer data reduction for a single side heated coolant channel. Part 1 summarizes over forty experiments which involve both single phase convection and flow boiling in a horizontal channel heated externally from the top side. Part 2 contains parametric dimensionless curves with parameters such as the coolant channel radius ratio, the Biot number, and the circumferential coordinate.

Boyd, Ronald D.↗

Operations manual: On Site Monitor (OSM), solar heating and cooling systems

The on-site monitor is a portable device which, when connected to a solar system site data acquisition subsystem; allows readouts of clock and sensor data in voltage or engineering units at instrumented solar heating and cooling sites. The unit is described and procedures for its proper operation are presented.

Source record↗

Self-contained constant-temperature heat absorber

System maintains precise thermal control of heat producing component, is not affected by changes in external pressure, ambient thermal environment, or gravity, and operates in both static and spinning attitudes. Size of device's spin axis-oriented orifice determines container pressure which establishes boiling temperature of heat absorption medium.

Lopez, R. W.↗

Solar heating and hot water system installed at Cherry Hill, New Jersey

The solar heating and hot water system installed in existing buildings at the Cherry Hill Inn in Cherry Hill, New Jersey is described in detail. The system is expected to furnish 31.5% of the overall heating load and 29.8% of the hot water load. The collectors are liquid evacuated tube type. The storage system is an above ground insulated steel water tank with a capacity of 7,500 gallons.

Source record↗

Solar heating and hot water system installed at Saint Louis, Missouri

The solar heating and hot water system installed at the William Tao & Associates, Inc., office building in St. Louis, Missouri is described, including maintenance and construction problems, final drawings, system requirements, and manufacturer's component data. The solar system was designed to provide 50 percent of the hot water requirements and 45 percent of the space heating needs for a 900 sq ft office space and drafting room. The solar facility has 252 sq ft of glass tube concentrator collectors and a 1000 gallon steel storage tank buried below a concrete slab floor. Freeze protection is provided by a propylene glycol/water mixture in the collector loop. The collectors are roof mounted on a variable tilt array which is adjusted seasonally and is connected to the solar thermal storage tank by a tube-in-shell heat exchanger. Incoming city water is preheated through the solar energy thermal storage tank.

Source record↗

Phase-Change Heat-Storage Module

Heat-storage module accommodates momentary heating or cooling overload in pumped-liquid heat-transfer system. Large heat-storage capacity of module provided by heat of fusion of material that freezes at or near temperature desired to maintain object to be heated or cooled. Module involves relatively small penalties in weight, cost, and size and more than compensates by enabling design of rest of system to handle only average load. Latent heat of fusion of phase-change material provides large heat-storage capacity in small volume.

Mulligan, James C.↗

Heat pipe thermal control system concept for the space station.

A program was undertaken to design and evaluate a high reliability, long life thermal control system for Space Station application. The program consisted of three sequential steps including the investigation of many thermal control elements to select the most reliable. The elements are combined into several system concepts. The most desirable approach is then selected and its characteristics are determined. The result of this project is a conceptual thermal control system design that employs heat pipes as primary components, both for heat transport and variable temperature control.

Scollon, T. R., Jr.↗

Analysis of data user's needs for performance evaluation of solar heating and cooling systems

In a successful data acquisition program, the information needs must be evaluated, the design and cost factors of the program must be determined, and a data management loop must be organized and operated in order to collect, process, and disseminate the needed information in useable formats. This paper describes each of these program elements in detail as an aid for the solar heating and cooling data manager and user to implement effective data acquisition and monitoring systems. Consideration is given to the development of evaluation techniques which will aid in the determination of solar energy systems performances.

Christensen, D. L.↗

Solar heating and hot water system installed at office building, One Solar Place, Dallas, Texas

A solar heating on cooling system is described which is designed to provide 87 percent of the space heating needs, 100 percent of the potable hot water needs and is sized for future absorption cooling. The collection subsystem consists of 28 solargenics, series 76, flat plate collectors with a total area of 1,596 square feet. The solar loop circulates an ethylene glyco water solution through the collectors into a hot water system exchanger. The water storage subsystem consists of a heat exchanger, two 2,300 gallon concrete hot water storage tanks with built in heat exchangers and a back-up electric boiler. The domestic hot water subsystem sends hot water to the 10,200 square feet floor area office building hot water water fixtures. The building cold water system provides make up to the solar loop, the heating loop, and the hot water concrete storage tanks. The design, construction, cost analysis, operation and maintenance of the solar system are described.

Source record↗

Technical Risks Associated with Heat Melt Compaction Systems

The processing of trash and waste is a welcome and valuable addition to humans living and working in space. Besides the obvious desire to have a pleasant and productive habitation environment, trash management has many practicalbenefits for crew health, resource recovery, and volume reclamation through garbage compaction. The Trash Compaction and Processing System (TCPS), which is a NASA project to develop a trash processing system for long-duration spaceflight, is currently undergoing concept development with engineering prototype validation through two contracted efforts. The development efforts are being supported with activities associated with the NASA Generation 2 Heat Melt Compactor (HMC). The HMC is a facility that compacts trash, recovers water, heats the trash to eliminate biological activity, and manages gas and vapor effluents. The resulting residual processed trash is a compact tile that is free of biological growth and that can be used for augmenting radiation shields. The work being conducted with the HMC focuses on high risk technical areas with respect to operations, subsystem performance, and ISS effluent management interface requirements. This paper gives an overview of the technical risks and the current use of the HMC as a facility for reducing risk.

HMC↗

A heat receiver design for solar dynamic space power systems

An advanced heat pipe receiver designed for a solar dynamic space power system is described. The power system consists of a solar concentrator, solar heat receiver, Stirling heat engine, linear alternator and waste heat radiator. The solar concentrator focuses the sun's energy into a heat receiver. The engine and alternator convert a portion of this energy to electric power and the remaining heat is rejected by a waste heat radiator. Primary liquid metal heat pipes transport heat energy to the Stirling engine. Thermal energy storage allows this power system to operate during the shade portion of an orbit. Lithium fluoride/calcium fluoride eutectic is the thermal energy storage material. Thermal energy storage canisters are attached to the midsection of each heat pipe. The primary heat pipes pass through a secondary vapor cavity heat pipe near the engine and receiver interface. The secondary vapor cavity heat pipe serves three important functions. First, it smooths out hot spots in the solar cavity and provides even distribution of heat to the engine. Second, the event of a heat pipe failure, the secondary heat pipe cavity can efficiently transfer heat from other operating primary heat pipes to the engine heat exchanger of the defunct heat pipe. Third, the secondary heat pipe vapor cavity reduces temperature drops caused by heat flow into the engine. This unique design provides a high level of reliability and performance.

Baker, Karl W.↗

Pumped Fluid Loop Heat Rejection and Recovery Systems for Thermal Control of the Mars Science Laboratory

This viewgraph presentation reviews the heat rejection and heat recovery system for thermal control of the Mars Science Laboratory (MSL). The MSL mission will use mechanically pumped fluid loop based architecture for thermal control of the spacecraft and rover. The architecture is designed to harness waste heat from an Multi Mission Radioisotope Thermo-electric Generator (MMRTG) during Mars surface operations for thermal control during cold conditions and also reject heat during the cruise aspect of the mission. There are several test that are being conducted that will insure the safety of this concept. This architecture can be used during any future interplanetary missions utilizing radioisotope power systems for power generation.

mechanical pump fluid loop↗