Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

DEVELOPMENT OF GLASS COMPOSITIONS TO IMMOBILIZE ALKALI, ALKALINE EARTH, LANTHANIDE AND TRANSITION METAL FISSION PRODUCTS FROM NUCLEAR FUEL REPROCESSING

The Advanced Fuel Cycle Initiative (AFCI) waste management strategy revolves around specific treatment of individual or groups of separated waste streams. A goal for the separations processes is to efficiently manage the waste to be dispositioned as high level radioactive waste. The Advanced Fuel Cycle Initiative (AFCI) baseline technology for immobilization of the lanthanide (Ln) and transition metal fission product (TM) wastes is vitrification into a borosilicate glass. A current interest is to evaluate the feasibility of vitrifying combined waste streams to most cost effectively immobilize the wastes resulting from aqueous fuel reprocessing. Studies showed that high waste loadings are achievable for the Ln only (Option 1) stream. Waste loadings in excess of 60 wt % (on a calcined oxide basis) were demonstrated via a lanthanide borosilicate (LaBS) glass. The resulting glasses had excellent relative durability as determined by the Product Consistency Test (PCT). For a combined Ln and TM waste stream glass (Option 2), noble metal solubility was found to limit waste loading. However, the measured PCT normalized elemental releases for this glass were at least an order of magnitude below that of Environmental Assessment (EA) glass. Current efforts to evaluate the feasibility of vitrifying combined Ln, TM, alkali (Cs is the primary radionuclide of concern) and alkaline earth (Sr is the primary radionuclide of concern) wastes (Option 3) have shown that these approaches are feasible. However, waste loading limitations with respect to heat load (Cs/Sr loading), molybdenum solubility and/or noble metal solubility will likely be realized and must be considered in determining the cost effectiveness of these approaches.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Helical muon beam cooling channel engineering design

The Helical Cooling Channel (HCC) achieves effective ionization cooling of the six-dimensional (6d) phase space of a muon beam by means of a series of 21st century inventions. In the HCC, hydrogen-pressurized RF cavities enable high RF gradients in strong external magnetic fields. The theory of the HCC, which requires a magnetic field with solenoid, helical dipole, and helical quadrupole components, demonstrates that dispersion in the gaseous hydrogen energy absorber provides effective emittance exchange to enable longitudinal ionization cooling. The 10-year development of a practical implementation of a muon-beam cooling device has involved a series of technical innovations and experiments that imply that an HCC of less than 300 m length can cool the 6d emittance of a muon beam by six orders of magnitude. We describe the design and construction plans for a prototype HCC module based on oxygen-doped hydrogen-pressurized RF cavities that are loaded with dielectric, fed by magnetrons, and operate in a superconducting helical solenoid magnet. The first phase of this project saw the development of a conceptual design for the integration of 805 MHz RF cavities into a 10 T Nb 3 Sn-based HS test section. Two very novel ideas are required to realize the design. The first idea is the use of dielectric inserts in the RF cavities to make them smaller for a given frequency so that the cavities and associated plumbing easily fit inside the magnet cryostat. Calculations indicate that heat loads will be tolerable, while RF breakdown of the dielectric inserts will be suppressed by the pressurized hydrogen gas. The second new idea is the use of a multi-layer Nb 3 Sn helical solenoid. The technology demonstrations for the two aforementioned key components of a 10T, 805 MHz HCC were begun in this project. The work load in the Fermilab Technical Division made it difficult to test a multi-layer Nb 3 Sn solenoid as originally planned. Instead, a complementary project was approved by the DOE Technical Topic Manager to develop magnets for the Mu2e experiment that fit well into the Fermilab Technical Division availability. The difference between the MCC helical solenoid and the Mu2e bent solenoid described in Appendix I is that the helical solenoid is made of coils that are in parallel planes with offset centers, while the coils in the bent solenoid follow the central particle trajectory and look much like a “slinky” toy. The muon-beam cooling-channel technologies developed in this project will enable a muon collider, the next step toward the energy frontier, Higgs/neutrino/Z-factories, and rare muon decay experiments. Commercial uses of the beams made possible by the cooling techniques developed in this project include scanning for nuclear contraband, studies of material properties with spin resonance techniques, and muon-catalyzed fusion.

43 PARTICLE ACCELERATORS↗

On the possible cycles via the unified perspective of cryocoolers. Part A: The Joule-Thomson cryocooler

Joule-Thomson (JT) cryocoolers possess a self adjusting effect, which preserves the state of the returning stream from the evaporator as a saturated vapor. The heat load can be entirely absorbed at constant temperature by evaporation even for different sized heat exchangers. It is not possible for the steady state flow resulting from a gradual cool down to penetrate 'deeper' into the two-phase dome, and produce a two phase return flow even with a heat exchanger of unlimited size. Such behavior was implicitly taken for granted in the literature but never clearly stated nor questioned and therefore never systematically proven. The discussion provided below provides such a proof via the unified model of cryocoolers. This model portrays all cryocoolers as magnifiers of their respective elementary temperature reducing mechanism through the process of 'interchanging'.

42 ENGINEERING↗

Steady state thermal-hydraulic analyses of the MITICA cooling circuits

Megavolt ITER Injector Concept Advancement is the full scale prototype of the heating and current drive neutral beam injectors for ITER, to be built at Consorzio RFX (Padova). The engineering design of its components is challenging: the total heat loads they will be subjected to (expected between 2 and 19 MW), the high heat fluxes (up to 20 MW/m{sup 2}), and the beam pulse duration up to 1 h, set demanding requirements for reliable active cooling circuits. In support of the design, the thermo-hydraulic behavior of each cooling circuit under steady state condition has been investigated by using one-dimensional models. The final results, obtained considering a number of optimizations for the cooling circuits, show that all the requirements in terms of flow rate, temperature, and pressure drop are properly fulfilled.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radio-frequency sheaths physics: Experimental characterization on Tore Supra and related self-consistent modeling

During the 2011 experimental campaign, one of the three ion cyclotron resonance heating (ICRH) antennas in the Tore Supra tokamak was equipped with a new type of Faraday screen (FS). The new design aimed at minimizing the integrated parallel electric field over long field lines as well as increasing the heat exhaust capability of the actively cooled screen. It proved to be inefficient for attenuating the radio-frequency (RF)-sheaths on the screen itself on the contrary to the heat exhaust concept that allowed operation despite higher heat fluxes on the antenna. In parallel, a new approach has been proposed to model self-consistently RF sheaths: the SSWICH (Self-consistent Sheaths and Waves for IC Heating) code. Simulations results from SSWICH coupled with the TOPICA antenna code were able to reproduce the difference between the two FS designs and part of the spatial pattern of heat loads and Langmuir probe floating potential. The poloidal pattern is a reliable result that mainly depends on the electrical design of the antenna while the radial pattern is on the contrary highly sensitive to loosely constrained parameters such as perpendicular conductivity that generates a DC current circulation from the private region inside the antenna limiters to the free scrape off layer outside these limiters. Moreover, the cantilevered bars seem to be the element in the screen design that enhanced the plasma potential.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gas Contamination Effects on Pulse Tube Performance

Experiments were performed to quantify the effect of contamination in the helium working gas of a typical pulse tube cryocooler operating at 60 K with 1 W of applied heating load.

Gas Contamination helium gas heating load↗

Reentry

Major problems in reentry deceleration loads, corridor width, range control, and heating loads

RANGE CONTROL↗

Lunar Base Heat Pump

The objective of this project was to investigate the feasibility of constructing a heat pump suitable for use as a heat rejection device in applications such as a lunar base. In this situation, direct heat rejection through the use of radiators is not possible at a temperature suitable for lde support systems. Initial analysis of a heat pump of this type called for a temperature lift of approximately 378 deg. K, which is considerably higher than is commonly called for in HVAC and refrigeration applications where heat pumps are most often employed. Also because of the variation of the rejection temperature (from 100 to 381 deg. K), extreme flexibility in the configuration and operation of the heat pump is required. A three-stage compression cycle using a refrigerant such as CFC-11 or HCFC-123 was formulated with operation possible with one, two or three stages of compression. Also, to meet the redundancy requirements, compression was divided up over multiple compressors in each stage. A control scheme was devised that allowed these multiple compressors to be operated as required so that the heat pump could perform with variable heat loads and rejection conditions. A prototype heat pump was designed and constructed to investigate the key elements of the high-lift heat pump concept. Control software was written and implemented in the prototype to allow fully automatic operation. The heat pump was capable of operation over a wide range of rejection temperatures and cooling loads, while maintaining cooling water temperature well within the required specification of 40 deg. C +/- 1.7 deg. C. This performance was verified through testing.

Walker, D.↗

Progress in preparing scenarios for operation of the International Thermonuclear Experimental Reactor

The development of operating scenarios is one of the key issues in the research for ITER which aims to achieve a fusion gain (Q) of ∼10, while producing 500 MW of fusion power for ≥300 s. The ITER Research plan proposes a success oriented schedule starting in hydrogen and helium, to be followed by a nuclear operation phase with a rapid development towards Q ∼ 10 in deuterium/tritium. The Integrated Operation Scenarios Topical Group of the International Tokamak Physics Activity initiates joint activities among worldwide institutions and experiments to prepare ITER operation. Plasma formation studies report robust plasma breakdown in devices with metal walls over a wide range of conditions, while other experiments use an inclined EC launch angle at plasma formation to mimic the conditions in ITER. Simulations of the plasma burn-through predict that at least 4 MW of Electron Cyclotron heating (EC) assist would be required in ITER. For H-modes at q{sub 95} ∼ 3, many experiments have demonstrated operation with scaled parameters for the ITER baseline scenario at n{sub e}/n{sub GW} ∼ 0.85. Most experiments, however, obtain stable discharges at H{sub 98(y,2)} ∼ 1.0 only for β{sub N} = 2.0–2.2. For the rampup in ITER, early X-point formation is recommended, allowing auxiliary heating to reduce the flux consumption. A range of plasma inductance (l{sub i}(3)) can be obtained from 0.65 to 1.0, with the lowest values obtained in H-mode operation. For the rampdown, the plasma should stay diverted maintaining H-mode together with a reduction of the elongation from 1.85 to 1.4. Simulations show that the proposed rampup and rampdown schemes developed since 2007 are compatible with the present ITER design for the poloidal field coils. At 13–15 MA and densities down to n{sub e}/n{sub GW} ∼ 0.5, long pulse operation (>1000 s) in ITER is possible at Q ∼ 5, useful to provide neutron fluence for Test Blanket Module assessments. ITER scenario preparation in hydrogen and helium requires high input power (>50 MW). H-mode operation in helium may be possible at input powers above 35 MW at a toroidal field of 2.65 T, for studying H-modes and ELM mitigation. In hydrogen, H-mode operation is expected to be marginal, even at 2.65 T with 60 MW of input power. Simulation code benchmark studies using hybrid and steady state scenario parameters have proved to be a very challenging and lengthy task of testing suites of codes, consisting of tens of sophisticated modules. Nevertheless, the general basis of the modelling appears sound, with substantial consistency among codes developed by different groups. For a hybrid scenario at 12 MA, the code simulations give a range for Q = 6.5–8.3, using 30 MW neutral beam injection and 20 MW ICRH. For non-inductive operation at 7–9 MA, the simulation results show more variation. At high edge pedestal pressure (T{sub ped} ∼ 7 keV), the codes predict Q = 3.3–3.8 using 33 MW NB, 20 MW EC, and 20 MW ion cyclotron to demonstrate the feasibility of steady-state operation with the day-1 heating systems in ITER. Simulations using a lower edge pedestal temperature (∼3 keV) but improved core confinement obtain Q = 5–6.5, when ECCD is concentrated at mid-radius and ∼20 MW off-axis current drive (ECCD or LHCD) is added. Several issues remain to be studied, including plasmas with dominant electron heating, mitigation of transient heat loads integrated in scenario demonstrations and (burn) control simulations in ITER scenarios.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PERFORMANCE OF NB{sub 3}SN QUADRUPOLE MAGNETS UNDER LOCALIZED THERMAL LOAD

This paper describes the results of design and analyses performed on 120-mm Nb{sub 3}Sn and NbTi quadrupole magnets with parameters relevant for the LHC IR upgrade. A realistic radiation heat load is evaluated in a wide luminosity range and translated into the magnet quench performance. The simulation results are supported by thermal measurements on a 90-mm Nb{sub 3}Sn quadrupole coil.

42 ENGINEERING↗

Using solar availability factors to adjust cool-wall energy savings for shading and reflection by neighboring buildings

The extent to which a solar-reflective “cool” wall can reduce a building's cooling load in summer or increase its heating load in winter scales with the wall's incident solar radiation, or solar availability. We assess how the solar availability at the wall of a central (modeled) building is affected by a neighboring wall across an urban canyon by calculating the central wall's solar availability factor (SAF), defined as the ratio of sunlight incident on the central wall in the presence of the neighboring wall to that incident in the absence of the neighboring wall. Cool-wall heating, ventilation, and air conditioning (HVAC) energy savings simulated for an isolated central building (no neighbors) can be multiplied by SAFs to account for interactions with neighboring walls. Monthly values of SAF were evaluated in 17 climates across the United States, including three in California, for north, east, south, and west central walls, over a wide range of canyon aspect ratio (height/width). Results for four representative aspect ratios—0.2, 1, 2, and 10—are presented. In Fresno, CA, monthly SAF ranges from 0.90 to 0.96 for central walls facing north, east, south, or west when the aspect ratio is 0.2 (two-story single-family homes across a street) and both the central and neighboring walls are conventional (albedo 0.25). Monthly SAFs decrease as aspect ratio rises, falling to 0.06–0.24 at an aspect ratio of 10 (adjacent 10-story buildings on the same side of the street). An example worked for a two-story single-family home in Fresno on the west side of a residential street yields SAFs of 0.47 (north), 0.92 (east), 0.50 (south), and 0.63 (west) to apply to the cool-wall annual HVAC energy savings computed for an isolated central building. Shading and reflection reduce the home's annual HVAC energy cost savings by 31%.

14 SOLAR ENERGY↗

A high resolution IR/visible imaging system for the W7-X limiter

A high-resolution imaging system, consisting of megapixel mid-IR and visible cameras along the same line of sight, has been prepared for the new W7-X stellarator and was operated during Operational Period 1.1 to view one of the five inboard graphite limiters. The radial line of sight, through a large diameter (184 mm clear aperture) uncoated sapphire window, couples a direct viewing 1344 × 784 pixel FLIR SC8303HD camera. A germanium beam-splitter sends visible light to a 1024 × 1024 pixel Allied Vision Technologies Prosilica GX1050 color camera. Both achieve sub-millimeter resolution on the 161 mm wide, inertially cooled, segmented graphite tiles. The IR and visible cameras are controlled via optical fibers over full Camera Link and dual GigE Ethernet (2 Gbit/s data rates) interfaces, respectively. While they are mounted outside the cryostat at a distance of 3.2 m from the limiter, they are close to a large magnetic trim coil and require soft iron shielding. We have taken IR data at 125 Hz to 1.25 kHz frame rates and seen that surface temperature increases in excess of 350 °C, especially on leading edges or defect hot spots. The IR camera sees heat-load stripe patterns on the limiter and has been used to infer limiter power fluxes (∼1–4.5 MW/m{sup 2}), during the ECRH heating phase. IR images have also been used calorimetrically between shots to measure equilibrated bulk tile temperature, and hence tile energy inputs (in the range of 30 kJ/tile with 0.6 MW, 6 s heating pulses). Small UFO’s can be seen and tracked by the FLIR camera in some discharges. The calibrated visible color camera (100 Hz frame rate) has also been equipped with narrow band C-III and H-alpha filters, to compare with other diagnostics, and is used for absolute particle flux determination from the limiter surface. Sometimes, but not always, hot-spots in the IR are also seen to be bright in C-III light.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design study of a laser-cooled infrared sensor

The performance of a solid-state optical refrigerator is the result of a complex interplay of numerous optical and thermal parameters. We present a first preliminary study of an optical cryocooler using ray-tracing techniques. A numerical optimization identified a non-resonant cavity with astigmatism. This geometry offered more efficient pump absorption by the YLF:10%Yb laser-cooling crystal compared to non-resonant cavities without astigmatism that have been pursued experimentally so far. Ray tracing simulations indicate that ~80% of the incident pump light can absorbed for temperatures down to ~100 K. Calculations of heat loads, cooling power, and net payload heat lift are presented. They show that it is possible to cool a payload to a range of 90–100 K while producing a net payload heat lift of 80 mW and 300 mW when pumping a YLF:10%Yb crystal with 20 W and 50 W at 1020 nm, respectively. This performance is suited to cool HgCdTe infrared detectors that are used for sensing in the 8–12 μm atmospheric window. While the detector noise would be ~6× greater at 100 K than at 77 K, the laser refrigerator would introduce no vibrations and thus eliminate sources of microphonic noise that are limiting the performance of current systems.

47 OTHER INSTRUMENTATION↗

Measure Guideline: Combination Forced-Air Space and Tankless Domestic Hot Water Heating Systems

This document describes design and application guidance for combination space and tankless domestic hot water heating systems (combination systems) used in residential buildings, based on field evaluation, testing, and industry meetings conducted by Building Science Corporation. As residential building enclosure improvements continue to drive heating loads down, using the same water heating equipment for both space heating and domestic water heating becomes attractive from an initial cost and space-saving perspective. This topic is applicable to single- and multi-family residential buildings, both new and retrofitted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Flight prototype CO2 and humidity control system

A regenerable CO2 and humidity control system is presently being developed for potential use on shuttle as an alternative to the baseline lithium hydroxide system. The system utilizes a sorbent material (designated HS-C) to adsorb CO2 and the latent heat load from the cabin atmosphere and desorb the CO2 and water vapor overboard when exposed to a space vacuum, thus reducing the overall vehicle heat rejection load. Continuous operation is achieved by utilizing two beds which are alternatively cycled between adsorption and desorption. The HS-C material process was verified. Design concepts for the auxiliary components for the HS-C prototype system were generated. Performance testing verified system effectiveness in controlling CO2 partial pressure and humidity.

Rudy, K. M.↗

Solar energy system performance evaluation. Seasonal report for SEECO Lincoln, Lincoln, Nebraska

The Solar Engineering and Equipment Company (SEECO) Lincoln solar energy system, designed for space heating only, is described and its operational performance for a 12 month period from April 1979 through March 1980 is evaluated. The system met 27 percent of the space heating load; however, system losses into the heated space from the storage bin and ductwork were significant. Reducing these losses would add appreciably to the system's efficiency. Net fossil energy savings were 11.31 million BTUs.

Source record↗

Solar energy system demonstration project at Wilmington Swim School, New Castle, Delaware

A solar energy system located at the Wilmington Swim School, New Castle, Delaware is described. The system was designed for a 40 percent heating and a 30 percent hot water solar contribution serving the heat loads in the following order: space heat - new addition, domestic water - entire facility, and pool heating - entire facility. On a cost basis for 2920 hours of operation, the heat reclaimed would cost $969.66 annually if provided by gas at 3.79 per million Btu's. At 5.5 centers per kwh, heat recovery costs of $481.80 percent a net savings of $487.86 annually.

Source record↗

Composite Pulse Tube

A modification of the design of the pulse tube in a pulse-tube cryocooler reduces axial thermal conductance while preserving radial thermal conductance. It is desirable to minimize axial thermal conductance in the pulse-tube wall to minimize leakage of heat between the warm and cold ends of the pulse tube. At the same time, it is desirable to maximize radial thermal conductance at the cold end of the pulse tube to ensure adequate thermal contact between (1) a heat exchanger in the form of a stack of copper screens inside the pulse tube at the cold end and (2) the remainder of the cold tip, which is the object to which the heat load is applied and from which heat must be removed. The modified design yields a low-heat-leak pulse tube that can be easily integrated with a cold tip. A typical pulse tube of prior design is either a thin-walled metal tube or a metal tube with a nonmetallic lining. It is desirable that the outer surface of a pulse tube be cylindrical (in contradistinction to tapered) to simplify the design of a regenerator that is also part of the cryocooler. Under some conditions, it is desirable to taper the inner surface of the pulse tube to reduce acoustic streaming. The combination of a cylindrical outer surface and a tapered inner surface can lead to unacceptably large axial conduction if the pulse tube is made entirely of metal. Making the pulse-tube wall of a nonmetallic, lowthermal- conductivity material would not solve the problem because the wall would not afford the needed thermal contact for the stack of screens in the cold end. The modified design calls for fabricating the pulse tube in two parts: a longer, nonmetallic part that is tapered on the inside and cylindrical on the outside and a shorter, metallic part that is cylindrical on both the inside and the outside. The nonmetallic part can be made from G-10 fiberglass-reinforced epoxy or other low-thermal-conductivity, cryogenically compatible material. The metallic part must have high thermal conductivity in the cryogenic temperature range and would typically be made of pure copper to satisfy this requirement. The metallic part is bonded to the nonmetallic part with epoxy. Copper screens are inserted in the metallic part to form the cold-end heat exchanger, then the assembled pulse tube is inserted in the cold tip.

Martin, Jerry L.↗