Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid integration study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

3-D Geological Modeling for Numerical Flow Simulation Studies of Gas Hydrate Reservoirs at the Kuparuk State 7-11-12 Pad in the Prudhoe Bay Unit on the Alaska North Slope

Accurate reservoir evaluation requires reliable three-dimensional (3-D) geological models. Here, this study conducted 3-D geological modeling for numerical flow simulation of the B1 sand gas hydrate reservoir at the Kuparuk State 7-11-12 pad, Prudhoe Bay Unit, Alaska North Slope. The model integrates well logs, core, and seismic data to address spatial heterogeneity in geological structures and reservoir properties. Two modeling types were performed: structural framework modeling and petrophysical property modeling. For structural framework modeling, seismic data and well log markers were used to reproduce subsurface structures characterized by a normal fault system. A volume-based modeling algorithm and stair-stepping grid were applied. The resulting 3-D model comprised 2,640,000 grid cells across 264 layers, including seven fault grids. For petrophysical property modeling, total porosity was initially modeled using sequential Gaussian simulation with collocated cokriging. To reproduce the upward coarsening of the B1 sand, upscaled log-derived total porosity and a three-dimensional (3-D) trend depicting total porosity variation were used as primary and secondary data, respectively. Gas hydrate saturation distribution was modeled similarly, with secondary data from estimated porosity distribution and seismic-derived acoustic impedance map enhancing accuracy. Results indicate higher gas hydrate saturation in the upper part of the B1 sand and areas with higher acoustic impedance. Intrinsic permeability was modeled from the total porosity and clay-bound water volume, and effective permeability was derived from the gas hydrate saturation and intrinsic permeability distributions based on the “Tokyo model”. Effective permeability distributions were influenced by the total porosity, gas hydrate saturation, and intrinsic permeability. Within the same layer, higher gas hydrate saturation leads to decreased effective permeability. In total, 100 sets of multiple scenarios were prepared, providing input data for dynamic flow simulations to evaluate the effects of lateral heterogeneity in reservoir properties and the hydraulic characteristics of faults on production behavior for preassessment before the long-term production test.

58 GEOSCIENCES↗

Model Predictive Voltage Control of Large-Scale PV or Hybrid PV-BESS Plants

Increased penetration level of inverter-based resources (IBRs) and renewable energy in the power grid has called for more requirements from the control of IBRs. In this paper, the voltage-reactive power control of a photovoltaic (PV) power plant or hybrid PV-battery energy storage system (BESS) plant connected to a bulk power grid, whilst meeting the grid requirements, is studied. In this paper, a continuous-set model predictive control (MPC) formulation is proposed for voltage-reactive power control. For the same, an aggregated dynamic PV plant model is developed based on the recursive system equivalencing method. The formulation is then implemented in PSCAD simulation on a 125 MW PV plant or hybrid PV-BESS plant. The MPC implementation achieves 10.13% voltage improvement based on PSCAD simulation results in a balanced fault case study. Simulation results further demonstrate that MPC provides improved voltage support over the conventional proportional-integral (PI) controller post-fault occurrence.

Abu rub, Omar↗

Robust Disturbance Rejection Rotor Current Control of Doubly-Fed Induction Generators

This article proposes a robust transient disturbance rejection current controller (TDRCC) to improve the transient performance of doubly-fed induction generators (DFIGs) in wind turbines during grid disturbances, such as short circuits. Here, the proposed robust TDRCC replaces the proportional-integral-derivative (PID) current controllers conventionally used in the vector control scheme of the DFIG rotor side converter (RSC). The TDRCC estimates the transient disturbances caused by grid faults or other external disturbances and provides compensation to the DFIG rotor voltage in the current control loops of the RSC to improve the robustness of the controller to disturbance. A sliding-mode current controller (SMCC) is also designed to highlight the transient performance improvement of the DFIG using the TDRCC over the state-of-the-art control methods during grid short circuit faults. Simulation studies are conducted in PSCAD/EMTDC for a 3.6-MW DFIG wind turbine with the proposed TDRCC, the conventional PI controller, and the SMCC, respectively during the most severe balanced three-phase grid short circuit fault specified by the U.S. grid code as well as an unbalance single-phase grid short circuit fault. Hardware experiments are conducted on a 200-W DFIG wind turbine emulator with the three different controllers for the same three-phase short circuit fault. Simulation and hardware experiment results show that the TDRCC reduces the peak rotor current significantly when compared with the PI and SMCC controlled DFIG system and, therefore, would help prolong the lifespan of the DFIG's power electronics and reduce maintenance costs.

42 ENGINEERING↗

Dataset of Generative AI Workload Power Profiles

This dataset provides a collection of high-resolution (5/10 Hz or every 0.2/0.1 seconds) power consumption profiles for generative artificial intelligence (GenAI) workloads executed on NLR's High Performance Computing (HPC) platform Kestrel. The dataset also includes examples of representative whole-facility power profiles generated using a bottom-up, event-driven, data center energy model . This dataset is designed to support research in energy modeling, infrastructure planning, energy system integration, and sustainability analysis for AI-driven computing systems. The dataset captures time-resolved electrical power measurements across a diverse set of configurations, including variations in job type (inference vs. training), workload (LLM vs. image generation), datasets, and number of compute nodes. Power traces are provided in a standardized format and include both raw/instantaneous and aggregated files. Each profile is accompanied by metadata describing workload parameters, enabling reproducibility and cross-study comparison. The dataset is intended for use in applications such as data center infrastructure planning, energy modeling, demand response and grid impact studies, and development and validation of system-level simulation tools. By making these workload-specific power profiles publicly available, this dataset aims to address the current lack of open, empirical energy data for generative AI systems and to facilitate transparent, reproducible research on the energy and environmental impacts of large-scale AI deployment. If you use this dataset, please cite the associated publication: Vercellino et al., “Measurement of Generative AI Workload Power Profiles for Whole-Facility Data Center Infrastructure Planning,” arXiv:2604.07345 (2026).

97 MATHEMATICS AND COMPUTING↗

Control Oriented Models for Co-Design: Technical Overview of MT HVDC, MVDC, and Solid State Transformer Building Blocks

The electric power system is shifting toward a power electronics–enabled grid, where converter based “building blocks” (e.g., high voltage direct current (HVDC) links, multi terminal HVDC (MT HVDC) networks, medium voltage DC (MVDC) links, and solid state transformers (SSTs)) provide fast, precise control of power flows, voltage, and frequency. This report develops and applies publicly shareable electromagnetic transient (EMT) and phasor models to examine how such building blocks can be composed and coordinated to support offshore wind integration, inter area transfers, feeder support, and resilience. Section 2 documents a modular multilevel converter (MMC)–based MT HVDC modeling framework and two use cases: a compact WSCC/IEEE 9 bus test system and a 240 bus “mini WECC” case with five offshore wind plants (OWFs). Phasor to EMT transfer, initialization, and sanity checks are summarized, and neutral demonstrations of normal and contingency operation are reported. Section 3 frames the problem of wind plant inertial frequency response (IFR): shaping energy release and recovery to improve nadir while avoiding aerodynamic stall; representative simulations illustrate the issues without disclosing proprietary control. Section 4 develops MVDC concepts through an IEEE 16 bus loop and an Olympic Peninsula case study that compares AC vs. MVDC corridors and shows how feeder headroom can be pooled via DC couplers. Section 5 surveys SST architectures and identifies a gap: scalable, communication free coordination of multiple SSTs for islanded feeder networks. Across the report, novel methods and configurations under separate publication and IP review are not disclosed; only topic oriented, replicable setups and non proprietary results are shown. These models and use cases are intended as foundations for future publications and co design studies on architecture, control, and coordination of PE enabled grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enabling Realistic Communications Evaluations for ADMS

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. As demand for the seamless integration of distributed energy resources (DERs) continues to increase, proper networking and communications systems are becoming important to support the DER infrastructure. This report summarizes validation of a private wireless LTE network in a laboratory environment. The purpose of this work is to 1) demonstrate the effectiveness of private wireless LTE communication for grid applications and 2) provide a means of evaluating latency and overall performance of wireless communication in grid applications. First, private wireless LTE communication was validated in a direct transfer trip relaying scenario as an example of one-way communications using grid equipment. This study provided a baseline understanding of the variation in latency for seven different kinds of wireless scenarios shown in Figure A below. As expected, weak (attenuated) wireless signal-based communication yielded the widest ranges in latency. When higher priority was set for the trip signal communication, this resulted in lower latency in communication timing. In the final phase of this project, the private wireless LTE network was validated using two-way communications in an advanced distribution management system (ADMS) testbed which was developed in the ESIF at NREL. The purpose of this was to study the impact of wireless communication on grid performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrification Futures Study: Impact of Electric Vehicles on Bulk Power Systems

This presentation builds on work presented at IEW2019 on "Transportation Scenarios of Electric Technology Adoption and Power Consumption" by providing insights on the impact of demand-side electrification, and electric vehicles in particular, on electricity supply and bulk power systems. This talk summarizes some results from the multi-year and multi-stakeholder Electrification Futures Study (EFS) series of reports. In particular, this work leverages integrated demand and supply modelling of future energy systems to provide insights on system design and operations focusing on demand flexibility and integration of variable renewables.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Electrical Fault Detection, Power Quality, Distributed Energy Resource Use Cases, and Cyber Event Applications with the Cyber Grid Guard System Using Distributed Ledger Technology

Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substation and are associated with distributed energy resources (DERs). The integrity and confidentiality of data from IEDs is crucial, and distributed ledger technology (DLT) could improve the resilience of microgrids by helping to make these data more secure. The most popular applications using blockchain technology for electrical utilities is in the field is based on energy trading. However, the dynamism of the penetration of customer owned DERs and the deployment of sensors with IEDs have led to the identification of new applications using DLT that are focused on other areas, such as monitoring, operation and management of the grid and its assets. In addition, the majority of studies on electrical grid applications with blockchain were validated with software simulations. Although general monitoring of power systems for using DLT could be evaluated in operational electric grids, other DLT research applications such as defense against cyber-attacks and/or electrical fault detection are not likely to be performed in a real infrastructure because of possible risks to the network/equipment security. This report summarizes the application of power system applications using distributed ledger technology (DLT), providing a secure DLT framework for collecting data from IEDs like power meters and protective relays inside and outside of an electrical substation and/or between two different electrical utilities. In this study, the use case scenarios were created and assessed for different power system application by using DLT. The electrical fault detection for faulted phases (1), power quality monitoring of phase voltage magnitudes, frequency levels and load power factor (2), DERs use case monitoring (3), and cyber-event applications (4) were performed in a test bed with a Cyber-Grid Guard (CGG) system using DLT. It had a real-time simulator with power meters and protective relays in-the-loop. The first section of this report presents a literature review of power system applications using blockchain at research level. The second section shows the theory and equations used on this report. The third section shows the description of the test bed, equipment, architecture, and electrical grid diagrams. The fourth section shows the experimental models and use case scenarios that were performed for the electrical fault detection, power quality, DERs use case, and cyber event applications with the CGG system using DLT. The fifth section shows the results collected from the tests based on comparing the time stamped events of the analog signals from the IEDs, DLT computer and real time simulator. The sixth section performed the discussion of the results for the use case scenarios. Finally, section seven presents the conclusions for this report were presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Techno-Economic Analysis of a Cryogenic Flux Capacitor for Grid Storage

Abstract The Cryogenic Flux Capacitor (CFC) is a cold, dense fluid storage core with integrated design features that afford the designer flexibility and provide new possibilities for the storage and discharge of energy. The stored energy, in this case, is represented by hydrogen physically bonded within the nanoscale pores within the aerogel composite blanket material, and the process of bonding or debonding is governed by principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (∼1,000 m2/g) allows for storage densities close to, or in some cases exceeding, that of normal boiling point liquids. Its performance easily exceeds what can be achieved via ambient temperature, high-pressure gas storage for an equivalent volume. CFC storage is predicted to be easily scalable, is constructed from readily available commercial materials, lends itself to a range of pressure applications, and is geometry insensitive. The high energy density of CFC-stored hydrogen allows long durations of storage, such as daily to monthly cycling, which corresponds to approximately 10 to 100 hours of duration, respectively. The techno-economic analysis examines different types of hydrogen storage for commercial viability. The assessment includes the use of hydrogen blended with natural gas in a combined cycle gas turbine. The study provides results for a range of blends from 100% natural gas to 100% hydrogen. The required fuel usages are estimated for the intended application in a grid scenario that features large amounts of renewable penetration, 10 hours, and as a baseload, 100 hours. The study presents preliminary estimates of the capital cost of storage and operating cost of storage. In addition, the cost of firing natural gas and capturing the carbon dioxide (CO2) in a carbon capture and sequestration (CCS) system is assessed. Based on the study, it is shown that CFC can competitively meet performance and cost needs for grid-based energy storage.

08 HYDROGEN↗

Development of Tailored Hydrocarbon-Based Pentablock Copolymer Membranes for Sodium-Polysulfide Flow Batteries

Long-duration energy storage (LDES) technologies are pivotal for the adoption of renewables like wind and solar. Non-aqueous redox flow batteries (NARFBs) with a sodium-polysulfide hybrid system feature high energy density independent of power density, yet face challenges with polysulfide shuttling. This study investigates a hydrocarbon-based penta-block copolymer membrane, Nexar, to mitigate crossover effects by balancing TFSI conversion and their crosslink density. The membranes are annealed to induce crosslinking for reducing electrolyte uptake and enhancing mechanical stability while demonstrating excellent ionic conductivity. The hydrocarbon-based membranes address environmental concerns associated with perfluoroalkyl substances and improve the performance and durability of NARFBs. In conclusion, our findings suggest that annealed Nexar membranes with tailored TFSI functionality offer a scalable, cost-effective solution for enhancing the efficiency of high-capacity energy storage systems, pivotal for grid integration of renewable sources.

25 ENERGY STORAGE↗

Enabling kilometer-scale E3SM land model simulation over North America: A new integrated framework solution

This study introduces a novel framework designed to enhance the performance, scalability, and portability of the kilometer-scale E3SM Land Model (km-ELM) within the E3SM modeling infrastructure. By seamlessly integrating cutting-edge data tools, we address existing challenges such as slow performance, limited scalability, and difficulties in software integration in current data-driven ELM simulation over large geographic areas. Our innovative approach leverages the KiloCraft data toolkit to generate unified inputs for simulations ranging from a single-cite case, to a 72,083-cell regional case to a continental configuration encompassing 21.6 million land grid cells at a 1 km × 1 km resolution. We conduct extensive strong- and weak-scaling experiments on three state-of-the-art supercomputers, utilizing up to 100,800 CPU cores across 2400 compute nodes to evaluate end-to-end metrics including wall-clock time, simulation-years-per-day (SYPD), initialization costs, and I/O throughput. Our results reveal the land (LND) component’s efficient scaling, demonstrating near-ideal weak scaling and strong-scaling parallel efficiencies reaching up to 87% at 50,400 cores. We confirm portability and reproducibility through bitwise-equivalent outputs across different machines using identical inputs over supported machines. Notably, at extreme scales, we identify I/O as a critical bottleneck and that leads to effective solution with the SCORPIO/ADIOS stack. Collectively, these findings validate the deployment of km-ELM at a continental scale with high parallel efficiency and provide essential guidance on configuration, decomposition, and I/O settings for optimized kilometer-scale land simulations in E3SM. This work emphasizes the innovative design and practical solutions that enhance the operational capabilities of km-ELM, focusing on software performance and scalability while leaving detailed scientific evaluations of simulated land processes for future investigations.

E3SM land model (ELM), km-ELM, scalability, perfor↗

Nanoscale Hybrid Electrolytes with Viscosity Controlled Using Ionic Stimulus for Electrochemical Energy Conversion and Storage

As renewable energy is rapidly integrated into the grid, the challenge has become storing intermittent renewable electricity. Technologies including flow batteries and CO 2 conversion to dense energy carriers are promising storage options for renewable electricity. To achieve this technological advancement, the development of next generation electrolyte materials that can increase the energy density of flow batteries and combine CO 2 capture and conversion is desired. Liquidlike nanoparticle organic hybrid materials (NOHMs) composed of an inorganic core with a tethered polymeric canopy (e.g., polyetheramine (HPE)) have a capability to bind chemical species of interest including CO 2 and redox-active species. In this study, the unique response of NOHM-I-HPE-based electrolytes to salt addition was investigated, including the effects on solution viscosity and structural configurations of the polymeric canopy, impacting transport behaviors. The addition of 0.1 M NaCl drastically lowered the viscosity of NOHM-based electrolytes by up to 90%, reduced the hydrodynamic diameter of NOHM-I-HPE, and increased its self-diffusion coefficient, while the ionic strength did not alter the behaviors of untethered HPE. This study is the first to fundamentally discern the changes in polymer configurations of NOHMs induced by salt addition and provides a comprehensive understanding of the effect of ionic stimulus on their bulk transport properties and local dynamics. These insights could be ultimately employed to tailor transport properties for a range of electrochemical applications.

25 ENERGY STORAGE↗

Sliding Mode Network Perimeter Control

Urban traffic congestion is a chronic problem faced by many cities in the US and worldwide. It results in inefficient infrastructure use as well as increased vehicle fuel consumption and emission levels. Congestion is intertwined with delay, as road users waste precious hours on the road, which in turn reduces productivity. Researchers have developed, and continue to design, tools and systems to alleviate this problem. Network perimeter control is one such tool that has been studied extensively. It attempts to control the flow of vehicles entering a protected area to ensure that the congested regime predetermined by the Network Fundamental Diagram (NFD) is not reached. In this paper, a method derived from sliding mode control theory is presented. Its main advantages over proportional-integral controllers include (1) minimal tuning, (2) no linearization of the governing equations, (3) no assumptions with regard to the shape of the NFD, and (4) ability to handle various demand profiles without the need to retune the controller. A sliding mode controller was implemented and tested on a congested grid network. The results show that the proposed controller produces network-wide delay savings and disperses congestion effectively.

42 ENGINEERING↗

A geo-visual analysis for exploring the socioeconomic benefits of the heating electrification using geothermal energy

In parallel to population growth and climate change, the rapid pace of urbanization worldwide has led to an enormous increase in energy demand and costs in urban areas. The subsequent energy burden has become an increasing concern for many households in the U.S. Previous studies have revealed that geothermal resources can effectively lower the electricity demand and carbon emissions in large cities. In this paper, we focus on the socioeconomic impacts of geothermal energy on urban systems by presenting an interactive visual analytics dashboard. The dashboard allows urban planners to spatially examine geothermal energy's practical benefits on energy affordability, urban livability, and resilience across the U.S. We compiled a list of socioeconomic metrics by integrating the simulation results from multiple geothermal and building models with multi-domain urban datasets (socioeconomic, demographic, and electricity utility). These metrics are created to characterize the benefits of the heating electrification of buildings using Geothermal Heat Pumps (GHP) for lowering the energy burden of middle-and low-income households nationwide. The visual dashboard employs a combination of multivariate, glyph-based, and geospatial visualization to reveal the variability and patterns in our metrics. We present a pilot study to demonstrate the GHPs' potential as a renewable and affordable solution for increasing the economic and energy grid resilience in U.S cities.

Xu, Haowen↗

Cyber-Physical Dynamic System (CPDS) Modeling for Frequency Regulation and AGC Services of Distributed Energy Resources

The substantial integration of renewable energy brings significant challenges to balance the system in real time because of the variability and intermittency of renewable power. For the reliable system operation, the frequency regulation service is used to stabilize the system frequency through automatically balancing the system generation and load. On one hand, with the substantially increasing deployment of renewable energy in electricity system, the requirement of frequency regulation (FR) services increases significantly. On the other hand, the current main resource of FR services, the controllable conventional generation, is continuously decreasing in the system generation mix. This means that in the future high renewable penetration power system, additional and alternative reliable FR services providers such as distributed energy storage (DES) resources should be explored. Although the capability of utility-scale energy storage to provide FR services has been demonstrated, the integrated control and dynamic modeling of distributed energy resource (DER) providing frequency regulation grid services has been rarely explored. There are several challenges to adopt DERs to provide reliable grid services as illustrated in FERC 755. First, the distributed installation of DES requires a comprehensive cyber-physical dynamic system (CPDS) modeling to fully consider the impacts of the communication latency variability on its real time FR provision capability. Unlike the conventional generators, there are two-layer communication between DERs and system operators which increase the communication delay. Second, unlike the conventional generators whose dynamic models have been comprehensively studied, the difference among individual DER components' power-dynamic characteristic brings challenges in the accurate dynamic AGC modeling of its power-frequency relationship. Third, the temporal dependent state of charge uncertainty of DERs challenges DERs' power and frequency regulation capacities scheduling in the look-ahead generation scheduling. Therefore, the aggregator should optimize the frequency regulation provision from individual DER in real time. To overcome these challenges, this project proposes a cyber-physical dynamic system (CPDS) model to handle the uncertainty of DERs two-layer communication latency and power dynamics. The variability of DERs' communication delay and dynamic constraints will be comprehensively modeled. The DERs' AGC model with communication delay is designed to validate DESs' frequency regulation services. Like current performance-based frequency regulation evaluation, the delivery of DERs' frequency regulation will be assessed through post-analysis of the actual AGC response with respect to the AGC control signal from system operators. Consequently, the reliability improvement with DERs providing reliable frequency regulation services can be evaluated from a comprehensive perspective considering all the dynamics of communication and power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Discovery of False Data Injection Attacks on Power Grid Frequency Controllers with Reinforcement Learning [Poster]

While inverter-based DER (distributed energy resources) are instrumental to integrating renewable energy into the power grid, they reduce the grid's mechanical inertia, thereby increasing the risk of frequency instabilities. To compensate for frequency instability risks, the grid must also undergo a transformation to include digital technologies that allow for two-way communication between the utility and customers. The current and future state of the power grid allows for building a cleaner energy landscape. However, the grid may also become vulnerable to novel cyber threats. To preemptively protect the power grid against elaborate cyber-attacks, we propose to discover potential threats via reinforcement learning. In this work, the focus is on studying false data injection attacks that target the control logic of frequency controllers. We show that a reinforcement learning agent can successfully discover how to best inject false data into linear droop controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimizing design and dispatch of a renewable energy system

Renewable energy technologies are becoming increasingly important due to their cost-competitiveness, and because of enhanced climate concerns. We demonstrate the capabilities of an integer-programming optimization model that minimizes capital (investment) and operational costs, and utility charges, while adhering to system sizing constraints, demand requirements, and interoperability characteristics of the systems chosen. Furthermore, the model recommends an optimally sized mix of renewable energy, conventional generation, and energy storage technologies, while simultaneously optimizing the corresponding dispatch strategy. Our case studies explore several venues, i.e., a small campus and a local hospital, with complex utility rate tariffs, multi-technology integration opportunities, and incentives for renewable power production. Using an optimization model, versus applying rules of thumb, can produce millions of dollars in savings over a 25-year time horizon and result in thousands of kilowatts of installed renewable energy.

25 ENERGY STORAGE↗

Intrusion Detection for Cybersecurity of Power Electronics Dominated Grids: Inverters PQ Set-Points Manipulation

This work provides cybersecurity analytics for a high photovoltaic (PV) penetrated distribution network, representing future power electronics dominated grid (PEDG). Firstly, the impact of active and reactive power (PQ) set-points manipulation on the network is studied. Then, an intrusion detection system (IDS) is developed for identifying the potentially compromised PV inverters in the network. The proposed IDS is based on defining the normal, safe, and abnormal operation regions of the PV inverters from point of view of the steady state voltage stability of the network. These three-operation regions are identified by utilizing active power, reactive power, and voltage (PQV) limits of each specific grid-following inverter in the network. Each grid-following inverter's PQV contour includes the information of network topology, inverter ratings, and inverter controller. The developed PQ limits are integrated into the centralized secondary control layer for realization of the proposed IDS. Furthermore, the proposed secondary control layer is capable of providing remedial actions during an anomaly event to enhance the grid resiliency. The theoretical analyses are verified by several attack scenarios for a network of grid-following inverters.

41 EE - Solar Energy Technologies Office (EE-4S)↗