Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gas capture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

HDG-1 Experiment Irradiation Monitoring Data Qualification Final Report

SUMMARY The U.S. Department of Energy (DOE) Advanced Reactor Technologies (ART) Graphite Research and Development (GRD) Program is conducting a series of six experiments to quantify the effects of irradiation on nuclear-grade graphite. This report documents the qualification of irradiation monitoring data for the fifth experiment, High Dose Graphite-1 (HDG-1). Qualified monitoring data are required by the ART program to support the design and licensing of the first high-temperature reactor (HTR) nuclear plant. Data are classified as Qualified if they meet the usage requirements described in the experiment planning and quality assurance (QA) documents, Failed if they do not meet those requirements and provide no usable information, or Trend if they do not fully meet all requirements but still provide useful information subject to an assessment of how any deficiencies may affect a particular use of the data. HDG-1 irradiation began with Advanced Test Reactor (ATR) Cycle 168B on August 24, 2020, and concluded after Cycle 173C on January 27, 2025. The HDG-1 capsule was removed from the reactor core twice—during core internal change (CIC) Cycle 170A and powered axial locator mechanism (PALM) Cycle 172A—to prevent overheating of the graphite specimens during high-power PALM cycles. The capsule was therefore irradiated during a total of seven normal ATR cycles: 168B, 169A, 171A, 171B, 173A, 173B, and 173C. Irradiation monitoring data evaluated in this report include thermocouple (TC) temperature, gas flow rate, gas moisture, gas pressure, specimen load, and graphite stack displacement. Temperature. A total of 14,508,065 TC temperature records were captured. Of these, 13,901,785 (95.8%) are Qualified and 606,280 (4.2%) are Failed. The principal source of failed temperature data was the instrument failure of TC-9 (Zone 2) on June 24, 2024, and TC-10 (Zone 1) on July 5, 2024, near the end of Cycle 173A, which resulted in 595,554 Failed readings. An additional 379 missing values and 10,347 slightly negative values from TC-13 during ATR outages are also Failed. Neither TC-9 nor TC-10 was used as a temperature-control TC, and their failures did not compromise capsule condition monitoring. Correlation analysis of all 13 TCs found no evidence of virtual junction formation. Control chart analysis revealed clear downward drift of approximately 80°C for TC-6 (Zone 3) relative to other stable TCs, and possible downward drift of approximately 60°C for TC-13 relative to the Zone 5 control TC (TC-1), though TC-13 remained consistent with the Zone 2 control TC (TC-12). Gas flow. A total of 20,088,090 gas flow rate records were captured. Of these, 19,941,463 (99.3%) are Qualified and 146,627 (0.7%) are Failed due to missing values. All argon, helium, and total gas flow data were within expected ranges throughout the irradiation. Gas moisture. A total of 1,116,005 outlet gas moisture values were captured. Of these, 1,101,421 (98.7%) are Qualified and 14,584 (1.3%) are Failed, comprising 14,556 out-of-range values and 28 missing values. The out-of-range moisture values exceeded 22,000 ppmv for approximately 1 week at the beginning of Cycle 173A, when accumulated moisture evaporated after the capsule was retrieved from water storage during PALM Cycle 172A and reinserted into the east flux trap. Moisture levels returned to below 25 ppmv for the remaining three cycles, and the transient high-moisture event did not affect the integrity of specimen irradiation. Gas pressure. A total of 7,812,035 gas pressure values were captured. Of these, 6,642,048 (85.0%) are Qualified and 1,169,987 (15.0%) outlet pressure values are Failed, comprising 718,537 zero outlet pressure values due to sensor failure from Cycle 168B through Cycle 171B, 54,550 missing values, and 396,900 too-low outlet pressure values, ranging from 1.1 to 1.6 psia after sensor replacement during Cycle 173A. Load. A total of 6,696,030 load values were captured. Of these, 6,694,580 (99.98%) are Qualified and 1,450 (0.02%) are Failed due to missing values. Applied loads to the six specimen stacks were stable throughout the irradiation. Stack displacement. A total of 6,696,030 displacement values were captured. Of these, 5,713,297 (85.32%) are Qualified and 3,781 (0.06%) are Failed due to missing values. Stack displacement increased consistently throughout the irradiation, reaching approximately 3.08 in. for Channels 5 and 6 by the end of irradiation. 978,952 (14.62%) substantially elevated displacements observed for Channel 6 beginning in Cycle 171A and for Channel 5 beginning in Cycle 173A are assigned Trend status. Raising pressure. A total of 1,115,999 raising pressure values were captured. Of these, 1,115,430 (99.95%) are Qualified and 569 (0.05%) are Failed due to missing values. Ram pressure. A total of 6,696,030 ram pressure values were captured. Of these, 6,692,249 (99.95%) are Qualified and 3,484 (0.05%) are Failed due to missing values. Stack raising was perf

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantifying Climate Change Effects of Bioenergy and BECCS: Critical Considerations and Guidance on Methodology

Bioenergy is a critical element in many national and international climate change mitigation efforts, including as a carbon dioxide removal strategy combined with the capture and durable geological storage of flue gas emissions (BECCS). However, divergent results on the effectiveness of bioenergy as a climate change mitigation measure are reported in the scientific literature. Climate impacts of bioenergy depend on case-specific factors, primarily biophysical features of the biomass production system, and the design and efficiency of conversion and capture processes. Estimates of climate impacts are also strongly affected by methodological choices and assumptions, and much of the divergence between studies derives from differences in the assumed alternate use of the land or feedstock, the alternate energy source and the system boundaries applied. We present a methodology to support robust estimates of the climate change effects of bioenergy systems, updating the standard methodology developed by the International Energy Agency's Technology Collaboration Program on Bioenergy. We provide guidance on the key choices including the reference land use and energy system that bioenergy is assumed to displace, spatial and temporal system boundaries, co-product handling, climate forcers considered, metrics applied and time horizon of impact assessment. Researchers should consider the whole bioenergy system including all life cycle stages, and choose system boundaries, reference systems and treatment of co-products that are consistent with the intended application of the results. The assessment should be normalised to a functional unit that can be compared with other systems delivering an equivalent quantity of the same function. All significant climate forcers should be included, and climate effects should be quantified using appropriate impact assessment methods that distinguish the impact of time. Consistency in methodology and interpretation will facilitate comparison between studies of different bioenergy systems.

09 BIOMASS FUELS↗

Prioritizing Off-gas Metrics

Off-gas research within the Material Recovery and Waste Form Development (MRWFD) team is dispersed among four national laboratories and multiple universities and small businesses. Ensuring research is conducted consistently and in a manner conducive to direct comparison is a nontrivial task. The team assembled to realign goals and expectations by identifying distinct R&D phases, prioritizing crucial metrics, and outlining standardized tests specifically associated with Kr, Xe, and I capture.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Monitoring Xenon Capture in a Metal Organic Framework Using Laser-Induced Breakdown Spectroscopy

Molten salt reactor operation will necessitate circulation of a cover gas to remove certain evolved fission products and maintain an inert atmosphere. The cover gas leaving the reactor core is expected to contain both noble and non-noble gases, aerosols, volatile species, tritium, and radionuclides and their daughters. To remove these radioactive gases, it is necessary to develop a robust off-gas system, along with novel sensors to monitor the gas stream and the treatment system performance. In this study, a metal organic framework (MOF) was engineered for the capture of Xe, a major contributor to the off-gas source term. The engineered MOF column was tested with a laser-induced breakdown spectroscopy (LIBS) sensor for noble gas monitoring. The LIBS sensor was used to monitor breakthrough tests with various Xe, Kr, and Ar mixtures to determine the Xe selectivity of the MOF column. This study offers an initial demonstration of the feasibility of monitoring off-gas treatment systems using a LIBS sensor to aid in the development of new capture systems for molten salt reactors.

47 OTHER INSTRUMENTATION↗

Assessment of the Fluid Dynamics Boundary Condition in Ablating or Blowing Flows

Improved models of ablative thermal protection systems have enabled the treatment of materials and fluid behavior in a coupled manner. This paper reports a new approach to modeling the interface between fluid and material, with attention to the conservation of species mass flux and energy on the fluid side of the interface. The general equation is presented and is shown to recover the traditional uncoupled fluid/materials response interface. Including the chemical reaction terms on the CFD side of the interface makes the heat flux exchange independent of the thermodynamic reference state and, therefore, a measurable quantity. Doing so allows the material response solver to take as input the surface heat flux rather than a film coefficient. Removing the film coefficient approximation enables more direct solution of vehicle thermal response but requires consistency in the wall state. The mixing of the shock layer and pyrolysis gas is then computed with finite rate chemistry within the fluid solver. The boundary conditions described have been implemented in the DPLR v4.05.1 code. Char removal is captured using finite rate chemistry in DPLR’s gas surface interaction module. Aspects of coupling these solutions to material response are discussed.

Ablation↗

Assessment of the Fluid Dynamics Boundary Condition in Ablating or Blowing Flows

Improved models of ablative thermal protection systems have enabled the treatment of materials and fluid behavior in a coupled manner. This paper reports a new approach to modeling the interface between fluid and material, with attention to the conservation of species mass flux and energy on the fluid side of the interface. The general equation is presented and is shown to recover the traditional uncoupled fluid/materials response interface. Including the chemical reaction terms on the CFD side of the interface makes the heat flux exchange independent of the thermodynamic reference state and, therefore, a measurable quantity. Doing so allows the material response solver to take as input the surface heat flux rather than a film coefficient. Removing the film coefficient approximation enables more direct solution of vehicle thermal response but requires consistency in the wall state. The mixing of the shock layer and pyrolysis gas is then computed with finite rate chemistry within the fluid solver. The boundary conditions described have been implemented in the DPLR v4.05.1 code. Char removal is captured using finite rate chemistry in DPLR’s gas surface interaction module. Aspects of coupling these solutions to material response are discussed.

Ablation↗

Water as a gas separation membrane

Efficient gas separation membranes are essential for carbon capture, biogas upgrading, and hydrogen purification. Inspired by how plants absorb CO 2 through water, we present a membrane platform that uses liquid water as the selective layer. Hydrophilic sub-100-nm pores stabilize water through strong capillary forces, enabling operation at feed pressures above 72 bar under dry and humid conditions. Selectivity is governed by gas solubility in water, while permeance is tuned by adjusting the water layer thickness. Reducing this thickness below 200 nm yields CO 2 permeances up to 11,600 gas permeation units with CO 2 :N 2 , CO 2 :CH 4 , and CO 2 :H 2 selectivities of 40, 26, and 31, respectively, surpassing the performance of state-of-the-art membranes. Operation is sustained for over a week without water loss, and performance scales using commercially available porous polymer supports under mixed-gas crossflow conditions. Water’s dissolution-based transport avoids saturation and reaction-rate limits, enabling a robust, high-performance, and environmentally benign gas separation platform.

08 HYDROGEN↗

Effect of Viscosity of a Deep Eutectic Solvent on CO 2 Capture Performance in an Energy-Efficient Membrane Contactor-Based Process

Greenhouse gas contributions to climate change have driven intense interest in the separation of CO 2 from wet flue gas streams. Deep eutectic solvents (DESs) are an emerging class of highly selective CO 2 absorbents. A prototypical DES, reline, is a mixture of choline chloride and urea. Reline is a thermally stable, nontoxic, and biodegradable solvent with negligible volatility and is inexpensive. We demonstrate a scalable and energy-efficient hollow fiber membrane contactor (HFMC)-based process using a green solvent for CO 2 capture. This process uses reline in HFMC to provide close interfacial interactions and contact between DES and CO 2 . This approach overcomes the disadvantages associated with direct absorption in DES and could potentially be applied to a variety of solvent-based CO 2 capture methods. Commercial, low-cost polymer hollow fiber membranes were evaluated for the capture of CO 2 with reline. From a mixed gas containing N 2 and CO 2 , the DES-based HFMC separated CO 2 with a purity of 97 mol %. The effect of the viscosity of reline on the CO 2 capture performance was investigated by adding water to the reline. The addition of water to reline significantly reduced its viscosity, which led to a permeate flux of 170 mmol/(m 2 ·h) at 35 °C, 4 bar, and 60 wt % water in solvent, which was approximately 8 times higher than that of the pure reline in the membrane contactor system. In situ Fourier transform infrared spectroscopy and nuclear magnetic resonance (NMR) revealed that reline absorbs CO 2 by physical absorption without forming new chemical compounds and that CO 2 separation by reline occurs via the pressure swing mechanism. This research provides fundamental insights about green physical solvent-based separation processes and a pathway toward industrial deployment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Control-Oriented Modeling of Cycle-to-Cycle Combustion Variability at the Misfire Limit in SI Engines

A control-oriented model is presented that can capture the prior-cycle correlation of combustion cycles during conditions with high levels of exhaust gas recirculation (EGR). Combustion events are modeled in discrete time and the dynamic evolution is captured by the residual air, fuel, and inert gas trapped in the combustion chamber. The mathematical formulation of the model is presented together with the calibration procedure to emulate a particular engine operating condition. A cycle-to-cycle system identification methodology is described which allows regressing model parameters from experimental data. Simulations are presented and compared to real engine measurements to show the modeling potential for analysis and control of combustion events.

Maldonado Puente, Bryan↗

Hydrogen Production from Polyethylene Pyrolysis

Hydrogen is anticipated to play a pivotal role in the future of clean energy and decarbonization efforts, serving as an energy storage medium, a power generation source, and a clean fuel for transportation. While most hydrogen is produced from carbonaceous fossil feedstocks like natural gas, petroleum, and coal, there is growing interest in using refuse-derived fuels such as waste plastics and municipal solid waste (MSW) as alternative feedstocks. Thermochemical processes such as pyrolysis and catalytic cracking can convert nonrecyclable plastics and organic MSW components to produce hydrogen with lower life cycle greenhouse gas emissions when coupled with CO 2 capture. Such approaches not only address waste-management challenges but also reduce methane emissions from landfills. Furthermore, waste feedstocks are low cost and can support meeting demands for hydrogen across various industries. In this work we examined production of hydrogen from high-density polyethylene (HDPE) as a model polymer using pyrolysis. Analytical studies of pyrolysis utilizing gas chromatography–mass spectrometry (GC/MS) provide insights into conversion pathways for plastic waste, potentially reducing the environmental footprint of traditional hydrogen production methods. This work generates a baseline methodology for hydrogen production from plastic pyrolysis with and without a catalyst and the necessary product distribution baseline from key single plastics. The effect of pyrolysis temperature on the conversion of HDPE was evaluated both with and without a catalyst(s), and the product distributions measured via GC/MS were identified and hydrogen formation was quantified. These results will help guide future research efforts to optimize catalysts and processes for more efficient hydrogen production and mixed plastic waste management.

Catalysts↗

Enhanced Depolarized Electro-Membrane System (EDEMS) for Direct Capture of Carbon Dioxide from Ambient Air (Final Report)

The goal of this final project report is to summarize the work conducted on project DE-FE0031962. In accordance with the Statement of Project Objectives (SOPO), the University of Kentucky Center for Applied Energy Research (UK CAER) (Recipient) developed an intensified process to capture CO2 from ambient conditions (400 ppm CO2). The process combines low-temperature solvent-aided membrane capture with electrochemically-mediated solvent regeneration to simultaneously capture ambient CO2 while regenerating the solvent. The technology employs only two primary units (regenerator and absorber/contactor) while generating high purity hydrogen as a co-product that can be sold, used for energy storage, or cost-saving depolarization of the direct air capture (DAC) system during the grid peak demand, allowing for flexible operation. When depolarization is employed, the operating voltage is reduced by more than 1 V. Since the technology is powered directly by DC electricity, it can seamlessly tie in with power sources like solar cells without the need for AC/DC converters, therefore allowing for a remote operation to further mitigate greenhouse gas generation toward deploying a negative carbon emissions technology that is completely decoupled from the carbon emissions from the power source for the DAC unit. The project results verified that UK CAER’s integrated approach addressed the complexities of incumbent DAC systems by demonstrating at ambient conditions, including (1) low gas-side pressure-drop facile CO2 capture via a membrane contactor with in-situ generated hydroxide as capture solvent, (2) multi-functional electrochemical regenerator for hydroxide regeneration, CO2 concentration and hydrogen production, and (3) depolarization using cathode-produced hydrogen to reduce energy requirement. The EH&S Assessment of the process did not identify any obvious concern for the bench-scale operation and no apparent barriers to implementing UK CAER’s carbon capture and solvent regeneration system at a larger scale.

20 FOSSIL-FUELED POWER PLANTS↗

Engineering-Scale Test of a Water-Lean Solvent for Post-Combustion Capture

EPRI, Pacific Northwest National Laboratory, RTI International, and their project collaborators developed an engineering-scale test of a new water-lean solvent, N-(2-ethoxyethyl)-3-morpholinopropan-1-amine (EEMPA or 2-EEMPA) as a post-combustion CO 2 capture solvent for power plant applications. This test was conducted using the Pilot Solvent Test Unit at the National Carbon Capture Center. The primary objective of this test was to collect long-term data operating EEMPA with both coal- and natural gas-representative flue gases at the approximately 0.5 MW e -equivalent scale (5–10 metric tons CO 2 /day captured). This report details the activities preparing for that test, data collected during the test campaign, and analyses and interpretations of that data.

20 FOSSIL-FUELED POWER PLANTS↗

Bismuth-Functionalized Silica Aerogels for Iodine Capture

The U.S. Department of Energy is looking into alternative sorbents for the removal of radioiodine from off-gas streams in a used nuclear fuel reprocessing plant. One class of sorbents considered are bismuth-functionalized silica aerogels which offer an efficient capture of iodine from off-gas streams and are environmentally friendly and lower cost when compared to silver-functionalized sorbents. Two types of bismuth-functionalized silica aerogels were successfully manufactured using a hierarchical synthesis approach:1) The Bi 3+ -aerogel with bismuth oxide nitrate hydroxide hydrate particles and 2) Bi-aerogel with bismuth metal and bismuth sulfide nanoparticles. Both sorbents exhibited high sorption capacity for iodine. However, presence of particles of different composition, size, and distribution on aerogel support resulted in different iodine loadings. The Bi 3+ -aerogel exhibited sorption capacity of 289 mg/g. In contrast, Bi-aerogel exhibited more that 20% higher sorption capacity. The heat-treatment of Bi 3+ -aerogel at 225? under hydrogen atmosphere increased iodine loading capacity to 351 mg/g.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Buffer Gas Acquisition and Storage

The acquisition and storage of buffer gases (primarily argon and nitrogen) from the Mars atmosphere provides a valuable resource for blanketing and pressurizing fuel tanks and as a buffer gas for breathing air for manned missions. During the acquisition of carbon dioxide (CO2), whether by sorption bed or cryo-freezer, the accompanying buffer gases build up in the carbon dioxide acquisition system, reduce the flow of CO2 to the bed, and lower system efficiency. It is this build up of buffer gases that provide a convenient source, which must be removed, for efficient capture Of CO2 Removal of this buffer gas barrier greatly improves the charging rate of the CO2 acquisition bed and, thereby, maintains the fuel production rates required for a successful mission. Consequently, the acquisition, purification, and storage of these buffer gases are important goals of ISRU plans. Purity of the buffer gases is a concern e.g., if the CO, freezer operates at 140 K, the composition of the inert gas would be approximately 21 percent CO2, 50 percent nitrogen, and 29 percent argon. Although there are several approaches that could be used, this effort focused on a hollow-fiber membrane (HFM) separation method. This study measured the permeation rates of CO2, nitrogen (ND, and argon (Ar) through a multiple-membrane system and the individual membranes from room temperature to 193K and 10 kpa to 300 kPa. Concentrations were measured with a gas chromatograph that used a thermoconductivity (TCD) detector with helium (He) as the carrier gas. The general trend as the temperature was lowered was for the membranes to become more selective, In addition, the relative permeation rates between the three gases changed with temperature. The end result was to provide design parameters that could be used to separate CO2 from N2 and Ar.

Parrish, Clyde F.↗

Cooperative carbon capture and steam regeneration with tetraamine-appended metal–organic frameworks

Natural gas has become the dominant source of electricity in the United States, and technologies capable of efficiently removing carbon dioxide (CO 2 ) from the flue emissions of natural gas–fired power plants could reduce their carbon intensity. However, given the low partial pressure of CO 2 in the flue stream, separation of CO 2 is particularly challenging. Taking inspiration from the crystal structures of diamine-appended metal–organic frameworks exhibiting two-step cooperative CO 2 adsorption, we report a family of robust tetraamine-functionalized frameworks that retain cooperativity, leading to the potential for exceptional efficiency in capturing CO 2 under the extreme conditions relevant to natural gas flue emissions. The ordered, multimetal coordination of the tetraamines imparts the materials with extraordinary stability to adsorption-desorption cycling with simulated humid flue gas and enables regeneration using low-temperature steam in lieu of costly pressure or temperature swings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Techno-economic Analysis of the Cryogenic Flux Capacitor Compared to Other forms of Hydrogen Production and Storage

The Cryogenic Flux Capacitor (CFC) is a cold, dense energy storage core that is being studied in the cryo-compressed, about 300 bar and 80K, region of gaseous hydrogen (GH2) storage and liquid hydrogen (LH2) region near the normal boiling point. The hydrogens storage is improved by physically bonding the molecules within the nanoscale pores of the aerogel composite blanket material. The process of bonding or debonding is governed by principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (~1,000 m2/g) allows its storage performance to easily exceed capacities of high-pressure GH2 storage for an equivalent volume. With the integrated aerogel, subscale tests have shown that storage is increased by about 49% over a simple tank filled with GH2 at the same operating temperature and pressure. For LH2 conditions, the CFC is shown to operate at equivalent densities. For the techno-economic analysis (TEA), the source of hydrogen is compared between onsite steam methane reforming (SMR) and onsite solar photovoltaic (PV) panels providing power to electrolyzers to produce GH2. The TEA compares pure hydrogen burning in a combined cycle gas turbine (CCGT) to hydrogen fuel cells with an overall net power output of 650 MW. The SMR system uses natural gas as an input and includes a carbon capture and storage (CCS) system. The levelized cost of electricity is developed based on the capital cost and operating cost of the systems. Sensitivities are discussed around the cost of natural gas, ranging from 1.93 USD per MMBTU to 6.75 USD per MMBTU, and carbon dioxide disposal, ranging from 7 USD per tonne to 10 USD per tonne. For comparison to the conventional CCGT baseline, a baseload scenario is adopted with 85% capacity factor. The results of the study show that onsite hydrogen generation from SMR is about 1 to 3 USD per kg over the life of the plant and the PV hydrogen production produces at 4 to 5 USD per kg. The cost of storage for CFC is compared to other systems, including high-pressure GH2 and atmospheric LH2. The system is shown to provide the lowest costs for all these options at the grid scale, due to its higher capacity than high-pressure GH2 and ability to operate at 80K, receiving refrigeration from liquid nitrogen systems reducing capital and operating costs when compared LH2 storage systems. SMR is competitive with CCGT at the gas prices, both of which have lower LCOE than the PV system. When accounting for variability in gas prices, the PV and electrolyzer system is less sensitive to these changes and provides the lowest LCOE across the whole range.

08 HYDROGEN↗

Mathematical Optimization of NGCC Solvent-based Carbon Capture Processes to Explore High Capture Designs

For point-source capture, much of the work to date has focused on achieving 90% capture – a somewhat arbitrary target above which parasitic losses to drive carbon capture and compression systems were believed to be too great to be economically justifiable. The recent push for deep decarbonization has caused this target to be revisited, and existing literature is of limited usefulness as most published studies have focused on carbon capture percentages of 90%. In this work, numerous mathematical optimizations were performed between carbon capture targets between 90%-99.8% of a Natural Gas Combined Cycle (NGCC) plant to better understand incremental cost of these systems so they may be compared to other decarbonization technologies, and to inform technical risk associated with targeting higher capture performance for these types of systems.

carbon capture↗

Removal of water vapor from streams containing carbon dioxide and/or carbon monoxide

Methods and systems for removing water vapor from a feed gas prior to further processing the feed gas according to a downstream PSA process are described. The feed gas can include CO2 and/or CO and/or H2 and the PSA process can be used to separate components of the feed gas from one another, for instance, for CO2 capture. Light product off of the PSA process is utilized to regenerate desiccant of a dryer used in the water vapor removal process that is carried out prior to the feed gas entering the PSA process. The water vapor removal process can be heated by providing thermal energy directly to the dryer and/or to a regenerating stream that regenerates the desiccant of the dryer. The thermal energy can be low cost energy—for instance, waste heat off of a system that provides the feed gas.

Ritter, James A.↗