Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “functional performance testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Operation of a Giant Magnetoresistive (GMR) Digital Isolator, Type IL510, Under Extreme Temperatures

A relatively new type of signal isolation based on Giant Magnetoresistive (GMR) technology was investigated for potential use in harsh temperature environments. Operational characteristics of the 2Mbps single channel, IL510-Series commercial-off-the-shelf (COTS) digital isolator chip was obtained under extreme temperature exposure and thermal cycling in the range of -190 C to +120 C. The isolator was evaluated in terms of its output signal delivery and stability, output rise (t(sub r)) and fall times (t(sub f)), and propagation delays at 50% level between input and output during low to high (t(sub PLH)) and high to low (t(sub PHL)) transitions. The device performed very well throughout the entire test temperature range as no significant changes occurred either in its function or in its output signal timing characteristics. The limited thermal cycling, which comprised of 12 cycles between -190 C and +120 C, also had no influence on its performance. In addition, the device packaging underwent no structural damage due to the extreme temperature exposure. These preliminary results indicate that this semiconductor chip has the potential for use in a temperature range that extends beyond its specified regime. Additional and more comprehensive testing, however, is required to establish its operation and reliability and to determine its suitability for long-term use in space exploration missions.

Patterson, Richard↗

The MSFC space station/space operations mechanism test bed

The Space Station/Space Operations Mechanism Test Bed consists of the following: a hydraulically driven, computer controlled Six Degree-of-Freedom Motion System (6DOF); a six degree-of-freedom force and moment sensor; remote driving stations with computer generated or live TV graphics; and a parallel digital processor that performs calculations to support the real time simulation. The function of the Mechanism Test Bed is to test docking and berthing mechanisms for Space Station Freedom and other orbiting space vehicles in a real time, hardware-in-the-loop simulation environment. Typically, the docking and berthing mechanisms are composed of two mating components, one for each vehicle. In the facility, one component is attached to the motion system, while the other component is mounted to the force/moment sensor fixed in the support structure above the 6DOF. The six components of the contact forces/moments acting on the test article and its mating component are measured by the force/moment sensor.

Sutton, William G.↗

Aeronautic Instruments. Section V : Power Plant Instruments

Part 1 gives a general discussion of the uses, principles, construction, and operation of airplane tachometers. Detailed description of all available instruments, both foreign and domestic, are given. Part 2 describes methods of tests and effect of various conditions encountered in airplane flight such as change of temperature, vibration, tilting, and reduced air pressure. Part 3 describes the principal types of distance reading thermometers for aircraft engines, including an explanation of the physical principles involved in the functioning of the instruments and proper filling of the bulbs. Performance requirements and testing methods are given and a discussion of the source of error and results of tests. Part 4 gives methods of tests and calibration, also requirements of gauges of this type for the pressure measurement of the air pressure in gasoline tanks and the engine oil pressure on airplanes. Part 5 describes two types of gasoline gauges, the float type and the pressure type. Methods of testing and calibrating gasoline depth gauges are given. The Schroeder, R. A. E., and the Mark II flowmeters are described.

Washburn, G E↗

Space Shuttle Orbiter carbon-carbon oxidation performance

Reusable, oxidation protected reinforced carbon carbon (RCC) has been successfully flown on forty Shuttle Orbiter flights. Thermal testing of the silicon carbide coated, reinforced carbon-carbon to determine its oxidation characteristics has been performed in both radiant and convective (plasma arc jet) heating test facilities. Subsurface oxidation of the RCC substrate as a result of oxygen penetrating micro cracks (fizzures) in the coating was characterized as a function of temperature and pressure for both convective and radiant environments. High temperature testing was performed to establish coating recession for over-temperature flight conditions experienced on abort trajectories. Suggested methods for using these test data to establish multi-mission reuse (i.e., mission life) and single mission limits are presented.

Curry, D. M.↗

Dark Energy Survey year 1 results: Joint analysis of galaxy clustering, galaxy lensing, and CMB lensing two-point functions

We perform a joint analysis of the auto and cross-correlations between three cosmic fields: the galaxy density field, the galaxy weak lensing shear field, and the cosmic microwave background (CMB) weak lensing convergence field. These three fields are measured using roughly 1300 sq. deg. of overlapping optical imaging data from first year observations of the Dark Energy Survey (DES) and millimeter-wave observations of the CMB from both the South Pole Telescope Sunyaev-Zel’dovich survey and Planck. We present cosmological constraints from the joint analysis of the two-point correlation functions between galaxy density and galaxy shear with CMB lensing. We test for consistency between these measurements and the DES-only two-point function measurements, finding no evidence for inconsistency in the context of flat Λ CDM cosmological models. Performing a joint analysis of five of the possible correlation functions between these fields (excluding only the CMB lensing autospectrum) yields S 8 ≡ σ 8 $\sqrt{Ω_{m}}/0.3$ = 0.782$^{+0.019}_{-0.025}$ and Ω m = 0.260$^{+0.029}_{-0.019}$. We test for consistency between these five correlation function measurements and the Planck -only measurement of the CMB lensing autospectrum, again finding no evidence for inconsistency in the context of flat Λ CDM models. Combining constraints from all six two-point functions yields S 8 = 0.776$^{+0.014}_{-0.021}$ and Ω m = 0.271$^{+0.022}_{-0.016}$. These results provide a powerful test and confirmation of the results from the first year DES joint-probes analysis.

Abbott, T. M. C.↗

Effect of design selection on response surface performance

Artificial neural nets and polynomial approximations were used to develop response surfaces for several test problems. Based on the number of functional evaluations required to build the approximations and the number of undetermined parameters associated with the approximations, the performance of the two types of approximations was found to be comparable. A rule of thumb is developed for determining the number of nodes to be used on a hidden layer of an artificial neural net and the number of designs needed to train an approximation is discussed.

Carpenter, William C.↗

Customizing Countermeasure Prescriptions using Predictive Measures of Sensorimotor Adaptability

Astronauts experience sensorimotor disturbances during the initial exposure to microgravity and during the readapation phase following a return to a gravitational environment. These alterations may lead to disruption in the ability to perform mission critical functional tasks during and after these gravitational transitions. Astronauts show significant inter-subject variation in adaptive capability following gravitational transitions. The ability to predict the manner and degree to which each individual astronaut will be affected would improve the effectiveness of a countermeasure comprised of a training program designed to enhance sensorimotor adaptability. Due to this inherent individual variability we need to develop predictive measures of sensorimotor adaptability that will allow us to predict, before actual space flight, which crewmember will experience challenges in adaptive capacity. Thus, obtaining this information will allow us to design and implement better sensorimotor adaptability training countermeasures that will be customized for each crewmember's unique adaptive capabilities. Therefore the goals of this project are to: 1) develop a set of predictive measures capable of identifying individual differences in sensorimotor adaptability, and 2) use this information to design sensorimotor adaptability training countermeasures that are customized for each crewmember's individual sensorimotor adaptive characteristics. To achieve these goals we are currently pursuing the following specific aims: Aim 1: Determine whether behavioral metrics of individual sensory bias predict sensorimotor adaptability. For this aim, subjects perform tests that delineate individual sensory biases in tests of visual, vestibular, and proprioceptive function. Aim 2: Determine if individual capability for strategic and plastic-adaptive responses predicts sensorimotor adaptability. For this aim, each subject's strategic and plastic-adaptive motor learning abilities are assessed using a test of locomotor function designed specifically to delineate both mechanisms. Aim 3: Develop predictors of sensorimotor adaptability using brain structural and functional metrics. We will measure individual differences in regional brain volumes (structural MRI), white matter integrity (diffusion tensor imaging, or DTI), functional network integrity (resting state functional connectivity MRI), and sensorimotor adaptation task-related functional brain activation (functional MRI). We decided to complete the data collection for Specific Aims 1, 2 and 3 simultaneously on the same subjects to increase data capture. By having the same subjects perform all three specific aims we can enhance our ability to detect how a wider range of factors can predict adaptability in a specific individual. This provides a much richer database and potentially a better understanding of the predictive power of the selected factors. In this presentation I will discuss preliminary data obtained to date.

Bloomberg, J. J.↗

Hydrogen Mitigation Process Installation at Nevada Solar One

The National Renewable Energy Laboratory (NREL) and Acciona Solar Power (ASP) have developed and are implementing a process that addresses the issue of hydrogen buildup in parabolic trough power plants. Our method selectively removes hydrogen from the expansion tanks of the power plant to control hydrogen levels in the circulating heat-transfer fluid (HTF). During previous work, we developed a sensor that measures hydrogen partial pressure in the expansion-tank headspace gas. We demonstrated that our sensor measures hydrogen levels over a wide range of partial pressure—from 1.33 mbar down to 0.003 mbar. More recently, we conceived and developed an integrated process module that performs both hydrogen sensing and separating functions. The sensor/separator measures hydrogen partial pressure in the headspace gas in the same way as our original sensor design. Additionally, the integrated module separates hydrogen from the headspace gas to reduce hydrogen to the level needed to maintain the performance of receivers in the collector field. We demonstrated the performance of a laboratory-scale version of this module. Testing showed that the module performed as expected: the accuracy of the sensing function was ±7%, and the hydrogen extraction rate for the separating mode was consistent with our modeling predictions. The primary benefit of this module is its simple design, both in terms of function and incorporation into the HTF subsystem of the power plant. Most recently, NREL and ASP planned, specified, and designed a mitigation process that is based on the integrated module. We are currently completing installation of this process at ASP's Nevada Solar One power plant in Boulder City, Nevada, USA. The mitigation process is being installed at ground level below the HTF expansion tanks, where it draws headspace gas from the tanks, removes hydrogen, and returns the treated gas back to the tanks. In this paper, we report progress on the installation and describe some of the many design details and challenges that we addressed during the past year. We will generate initial performance data from the Nevada Solar One mitigation process in early 2020.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Cartridge output testing - Methods to overcome closed-bomb shortcomings

Although the closed-bomb test has achieved virtually universal acceptance for measuring the output performance of pyrotechnic cartridges, there are serious shortcomings in its ability to quantify the performance of cartridges used as energy sources for pyrotechnic-activated mechanical devices. This paper presents several examples of cartridges (including the NASA Standard Initiator NSI) that successfully met closed-bomb performance requirements, but resulted in functional failures in mechanisms. To resolve these failures, test methods were developed to demonstrate a functional margin, based on comparing energy required to accomplish the function to energy deliverable by the cartridge.

Bement, Laurence J.↗

Automated Activation and Deactivation of a System Under Test

The MPLM Automated Activation/Deactivation application (MPLM means Multi-Purpose Logistic Module) was created with a three-fold purpose in mind: 1. To reduce the possibility of human error in issuing commands to, or interpreting telemetry from, the MPLM power, computer, and environmental control systems; 2. To reduce the amount of test time required for the repetitive activation/deactivation processes; and 3. To reduce the number of on-console personnel required for activation/ deactivation. All of these have been demonstrated with the release of the software. While some degree of automated end-item commanding had previously been performed for space-station hardware in the test environment, none approached the functionality and flexibility of this application. For MPLM activation, it provides mouse-click selection of the hardware complement to be activated, activates the desired hardware and verifies proper feedbacks, and alerts the user when telemetry indicates an error condition or manual intervention is required. For MPLM deactivation, the product senses which end items are active and deactivates them in the proper sequence. For historical purposes, an on-line log is maintained of commands issued and telemetry points monitored. The benefits of the MPLM Automated Activation/ Deactivation application were demonstrated with its first use in December 2002, when it flawlessly performed MPLM activation in 8 minutes (versus as much as 2.4 hours for previous manual activations), and performed MPLM deactivation in 3 minutes (versus 66 minutes for previous manual deactivations). The number of test team members required has dropped from eight to four, and in actuality the software can be operated by a sole (knowledgeable) system engineer.

Poff, Mark A.↗

Sensorimotor Predictors: Examining the Relationship Between Measures of Post-Landing Sensorimotor Functional Task Performance

Spaceflight drives adaptive changes in healthy individuals appropriate for sensorimotor function in a microgravity environment. These changes are maladaptive for return to Earth's gravity. The inter-individual variability of sensorimotor decrements is striking, although poorly understood. The goal of this study is to identify a set of behavioral, neuroimaging and genetic measures that can be used to predict early post-flight performance on sensorimotor functional tasks. To date, we have recruited fifteen astronauts who returned from the International Space Station on Soyuz and participated in sensorimotor field tests and/or posturography within one day following long-duration spaceflight. We are specifically utilizing a combination of three quantitative post-flight functional task outcomes(relative to pre-flight baselines): tandem walk, recovery from fall and dynamic posturography, along with a subjective self-rating of post-flight decrements and recovery. The recovery from fall is performed with eyes open on a stable support, allowing the use of vestibular, visual and proprioceptive feedback for task performance. In contrast, the dynamic posturography measures are performed with eyes closed on asway-referenced unstable support, requiring reliance on vestibular feedback for task performance. Tandem walk is performed on a stable surface with eyes open and eyes closed. Fourteen of the 15 subjects performed the field tests. These were nominally performed during three timepoints on the first postflight day, while posturography was performed only once during the third time point after direct return to JSC. More than 20% were unable to complete the initial field testing in the medical tent, while all participants completed testing during the third time point at JSC. As expected, there was considerable variability among all performance outcome measures, with more variability post-flight relative to preflight. Given the variability in all post-flight outcomes, we have been examining the relationships in performance across tasks. While there is a strong association within tests obtained at different landing daytime points, our preliminary findings suggest that by R+24 hrs performance on one post-flight test does not necessarily correlate with performance on other post-flight tests. This underscores the importance of a comprehensive post-flight test battery including different types of tasks with varying sensory feedback. We expect that further examining specific behavioral, neuroimaging and genetic sensorimotor biomarkers with post-flight functional task performance will improve both our understanding of the individual variability and our strategy to optimize sensorimotor countermeasures.

S J Wood↗

Sensorimotor Predictors: Examining the Relationship Between Measures of Post-Landing Sensorimotor Functional Task Performance

Spaceflight drives adaptive changes in healthy individuals appropriate for sensorimotor function in a microgravity environment. These changes are maladaptive for return to Earth's gravity. The inter-individual variability of sensorimotor decrements is striking, although poorly understood. The goal of this study is to identify a set of behavioral, neuroimaging and genetic measures that can be used to predict early post-flight performance on sensorimotor functional tasks. To date, we have recruited fifteen astronauts who returned from the International Space Station on Soyuz and participated in sensorimotor field tests and/or posturography within one day following long-duration spaceflight. We are specifically utilizing a combination of three quantitative post-flight functional task outcomes(relative to pre-flight baselines): tandem walk, recovery from fall and dynamic posturography, along with a subjective self-rating of post-flight decrements and recovery. The recovery from fall is performed with eyes open on a stable support, allowing the use of vestibular, visual and proprioceptive feedback for task performance. In contrast, the dynamic posturography measures are performed with eyes closed on asway-referenced unstable support, requiring reliance on vestibular feedback for task performance. Tandem walk is performed on a stable surface with eyes open and eyes closed. Fourteen of the 15 subjects performed the field tests. These were nominally performed during three timepoints on the first post flight day, while posturography was performed only once during the third time point after direct return to JSC. More than 20% were unable to complete the initial field testing in the medical tent, while all participants completed testing during the third time point at JSC. As expected, there was considerable variability among all performance outcome measures, with more variability post-flight relative to preflight. Given the variability in all post-flight outcomes, we have been examining the relationships in performance across tasks. While there is a strong association with in tests obtained at different landing daytime points, our preliminary findings suggest that by R+24 hrs performance on one post-flight test does not necessarily correlate with performance on other post-flight tests. This underscores the importance of a comprehensive post-flight test battery including different types of tasks with varying sensory feedback. We expect that further examining specific behavioral, neuroimaging and genetic sensorimotor biomarkers with post-flight functional task performance will improve both our understanding of the individual variability and our strategy to optimize sensorimotor countermeasures.

Yiri De Dios↗

Full-Scale Hollow Fiber Spacesuit Water Membrane Evaporator Prototype Development and Testing for Advanced Spacesuits

The spacesuit water membrane evaporator (SWME) is being developed to perform the thermal control function for advanced spacesuits to take advantage of recent advances in micropore membrane technology in providing a robust heat-rejection device that is potentially less sensitive to contamination than is the sublimator. Principles of a sheet membrane SWME design were demonstrated using a prototypic test article that was tested in a vacuum chamber at JSC in July 1999. The Membrana Celgard X50-215 microporous hollow fiber (HoFi) membrane was selected after recent contamination tests as the superior candidate among commercial alternatives for HoFi SWME prototype development. Although a number of design variants were considered, one that grouped the fiber layers into stacks, which were separated by small spaces and packaged into a cylindrical shape, was deemed best for further development. An analysis of test data showed that eight layer stacks of the HoFi sheets that had good exposure on each side of the stack would evaporate water with high efficiency. A design that has 15,000 tubes, with 18 cm of exposed tubes between headers has been built and tested that meets the size, weight, and performance requirements of the SWME. This full-scale prototype consists of 30 stacks, each of which are formed into a chevron shape and separated by spacers and organized into three sectors of ten nested stacks. Testing has been performed to show contamination resistance to the constituents expected to be found in potable water produced by the distillation processes. Other tests showed the sensitivity to surfactants.

Bue, Grant↗

High‐order symmetric cubature rules for tetrahedra and pyramids

Abstract In this article, we present an algorithm to construct high‐order fully symmetric cubature rules for tetrahedral and pyramidal elements, with positive weights and integration points that are in the interior of the domain. Cubature rules are fully symmetric if they are invariant to affine transformations of the domain. We divide the integration points into symmetry orbits where each orbit contains all the points generated by the permutation stars. These relations are represented by equality constraints. The construction of symmetric cubature rules require the solution of nonlinear polynomial equations with both inequality and equality constraints. For higher orders, we use an algorithm that consists of five sequential phases to produce the cubature rules. In the literature, symmetric numerical integration rules are available for the tetrahedron for orders p = 1 – 10, 14 , and for the pyramid up to p = 10 . We have obtained fully symmetric cubature rules for both of these elements up to order p = 20 . Numerical tests are presented that verify the polynomial‐precision of the cubature rules. Convergence studies are performed for the integration of exponential, weakly singular, and trigonometric test functions over both elements with flat and curved faces. With increase in p , improvements in accuracy is realized, though nonmonotonic convergence is observed.

Jaśkowiec, Jan↗

Methods for diagnosing and quantifying double pulsing in a Uranium Neutron Collar system using shift register logic

Double pulsing in neutron coincidence counters is the result of a pulse processing chain-3He proportional counter timing incompatibility known to nondestructive assay system designers. It is not currently widely acknowledged, or accounted for, in the user community. However, it is gaining attention as list mode data acquisition and analysis becomes more commonly used for system diagnostics, revealing features that have been overlooked by historic timing gate selection using traditional shift register data acquisition methods. Double pulsing increases the apparent number of measured neutron events from a source. Therefore, it may contribute to a falsely increased count rate if present at the operational high voltage used when assaying samples, even with set predelays. The authors have previously studied the effects of double pulsing, using list mode data acquisition and analysis on neutron pulse trains in three common neutron coincidence counting systems used in routine measurements for international safeguards: a Canberra Industries JCC-71 Neutron Coincidence Collar, a variant on the Canberra Industries JCC-51 Active Well Neutron Coincidence Counter (the Large Volume Active Well Neutron Coincidence Counter), and an AnTech Inc. N2071 Neutron Coincidence Collar. We find that this non-ideal behavior was isolated to the Amptek A111 Charge Sensitive Preamplifier & Discriminator chip used in both the Canberra Industries and Antech systems. The double pulsing fraction was calculated in post-analysis for various high voltage settings in these A111-based systems, assuming no predelay settings. In this work, the authors expand upon this identification and analysis to make it more translatable between list mode data acquisition and analysis and shift register-based analysis. By investigating the double pulsing fractions in a JCC-71 Uranium Neutron Collar as a function of predelay settings, as well as describing and performing alternative tests and analyses to diagnose and quantify the double pulsing using shift register logic, this work hopes to complete the picture of double pulsing identification and analysis.

Safeguards↗

Pyomo: Accidentally outrunning the bear

Pyomo is an open-source optimization modeling software that has undergone significant evolution since its inception in 2008. Pyomo has evolved to enhance flexibility, solver integration, and community engagement. Modern collaborative tools for open-source software have facilitated the development of new Pyomo functionality and improved our development process through automated testing and performance-tracking pipelines. However, Pyomo faces challenges typical of research software, including resource limitations and knowledge retention. The Pyomo team’s commitment to better development practices and community engagement reflects a proactive approach to these issues. We describe Pyomo’s development journey, highlighting both successes and failures, in the hopes that other open-source research software packages may benefit from our experiences.

automation↗

A Simple Correction for Nonadditive Dispersion within Extended Symmetry-Adapted Perturbation Theory (XSAPT)

Extended symmetry-adapted perturbation theory (XSAPT), in conjunction with empirical “+aiD” potentials fit to ab initio dispersion data, is a low-scaling approach to compute intermolecular interaction energies in noncovalent clusters. One shortcoming is that the aiD atom–atom dispersion potentials are independent of the chemical environment of the atoms in question and therefore neglect nonadditive dispersion effects. These can be significant in large systems, so to account for them we test a simple correction to XSAPT(KS)+aiD, where “KS” indicates the use of Kohn–Sham orbitals. This correction, which can be evaluated at fourth-order cost using double-ζ basis sets, is based on comparing second-order SAPT dispersion with and without a self-consistent charge embedding for the monomer wave functions. The correction amounts to ~1.4 kcal/mol in (H 2 O) 6 but ~5.5 kcal/mol in (H 2 O) 20 . With the nonadditive dispersion correction, XSAPT(KS)+aiD affords errors of ~1 kcal/mol for isomers of F–(H 2 O) 10 and (H 2 O) 20 , where the benchmarks are complete-basis CCSD(T) energies, as well as for ion–water clusters X(H 2 O)n where n ≤ 6 and X = F – , Cl – , SO 4 2– , Li + , Na + , or K + . We also test the MP2 method and a variety of density-functional methods that have been specifically recommended for noncovalent interactions. Among the latter, only ωB97X-V and ωB97M-V can be recommended for ion–water clusters, as mean errors for other popular approaches (including ωB97X-D3 and several Minnesota functionals) exceed 1 kcal/mol. Lastly, we examine clathrate-hydrate host/guest complexes whose mixture of hydrogen bonding and dispersion make them challenging tests for noncovalent quantum chemistry. Although the B97-D2 functional performs best for clathrate hydrates and has been previously recommended in other studies of these inclusion complexes, its performance for other systems examined here is quite poor. We are unable to find a functional whose accuracy is ≲1 kcal/mol accuracy for both clathrate hydrates and ion–water clusters. However, the XSAPT(KS)+aiD method with the nonadditive dispersion correction can achieve this, with a mean error for the clathrate hydrates of 0.3 kcal/mol.

74 ATOMIC AND MOLECULAR PHYSICS↗

HDTS 2017.1 Testing and Verification Document

This report is a continuation of the series of Hunter Dose Tracking System (HDTS) Quality Assurance documents including (Foley and Powell, 2010; Dixon, 2012; Whiteside, 2017b). In this report we have created a suite of automated test cases and a system to analyze the results of those tests as well as documented the methodology to ensure the field system performs within specifications. The software test cases cover all of the functions and interactions of functions that are practical to test. With the developed framework, if software defects are discovered, it will be easy to create one or more test cases to reproduce the defect and ensure that code changes correct the defect.

97 MATHEMATICS AND COMPUTING↗