Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fire effects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Portable convertible blast effects shield

A rapidly deployable portable convertible blast effects shield/ballistic shield includes a set two or more frusto-conically-tapered telescoping rings operably connected to each other to convert between a telescopically-collapsed configuration for storage and transport, and a telescopically-extended upright configuration forming an expanded inner volume. In a first embodiment, the upright configuration provides blast effects shielding, such as against blast pressures, shrapnel, and/or fire balls. And in a second embodiment, the upright configuration provides ballistic shielding, such as against incoming weapons fire, shrapnel, etc. Each ring has a high-strength material construction, such as a composite fiber and matrix material, capable of substantially inhibiting blast effects and impinging projectiles from passing through the shield. And the set of rings are releasably securable to each other in the telescopically-extended upright configuration by the friction fit of adjacent pairs of frusto-conically-tapered rings to each other.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Study of Plume Impingement Effects in the Lunar Lander Environment

Plume impingement effects from the descent and ascent engine firings of the Lunar Lander were analyzed in support of the Lunar Architecture Team under the Constellation Program. The descent stage analysis was performed to obtain shear and pressure forces on the lunar surface as well as velocity and density profiles in the flow field in an effort to understand lunar soil erosion and ejected soil impact damage which was analyzed as part of a separate study. A CFD/DSMC decoupled methodology was used with the Bird continuum breakdown parameter to distinguish the continuum flow from the rarefied flow. The ascent stage analysis was performed to ascertain the forces and moments acting on the Lunar Lander Ascent Module due to the firing of the main engine on take-off. The Reacting and Multiphase Program (RAMP) method of characteristics (MOC) code was used to model the continuum region of the nozzle plume, and the Direct Simulation Monte Carlo (DSMC) Analysis Code (DAC) was used to model the impingement results in the rarefied region. The ascent module (AM) was analyzed for various pitch and yaw rotations and for various heights in relation to the descent module (DM). For the ascent stage analysis, the plume inflow boundary was located near the nozzle exit plane in a region where the flow number density was large enough to make the DSMC solution computationally expensive. Therefore, a scaling coefficient was used to make the DSMC solution more computationally manageable. An analysis of the effectiveness of this scaling technique was performed by investigating various scaling parameters for a single height and rotation of the AM. Because the inflow boundary was near the nozzle exit plane, another analysis was performed investigating three different inflow contours to determine the effects of the flow expansion around the nozzle lip on the final plume impingement results.

Marichalar, Jeremiah↗

Characterization of Particulate Matter Profiling and Alveolar Deposition from Biomass Burning in Northern Thailand: The 7-SEAS Study

Biomass burning (BB) frequently occurs in SouthEast Asia (SEA), which significantly affects the air quality and could consequently lead to adverse health effects. The aim of this study was to characterize particulate matter (PM) and black carbon (BC) emitted from BB source regions in SEA and their potential of deposition in the alveolar region of human lungs. A 31-day characterization of PM profiling was conducted at the Doi Ang Khang (DAK) meteorology station in northern Thailand in March 2013. Substantial numbers of PM (10147 +/- 5800 # per cubic centimeter) with a geometric mean diameter (GMD) of 114.4 +/- 9.2 nm were found at the study site. The PM of less than 2.5 micron in aerodynamic diameter (PM sub 2.5) hourly-average mass concentration was 78.0 +/- 34.5 per cubic microgram whereas the black carbon (BC) mass concentration was 4.4 +/- 2.6 micrograms per cubic meter. Notably, high concentrations of nanoparticle surface area (100.5 +/- 54.6 square micrometers per cubic centimeter) emitted from biomass burning can be inhaled into the human alveolar region. Significant correlations with fire counts within different ranges around DAK were found for particle number, the surface area concentration of alveolar deposition, and BC. In conclusion, biomass burning is an important PM source in SEA, particularly nanoparticles, which has high potency to be inhaled into the lung environment and interact with alveolar cells, leading to adverse respiratory effects. The fire counts within 100 to 150 km shows the highest Pearson's r for particle number and surface area concentration. It suggests 12 to 24 hr could be a fair time scale for initial aging process of BB aerosols. Importantly, the people lives in this region could have higher risk for PM exposure.

biomass burning↗

Determination of Realistic Fire Scenarios in Spacecraft

This paper expands on previous work that examined how large a fire a crew member could successfully survive and extinguish in the confines of a spacecraft. The hazards to the crew and equipment during an accidental fire include excessive pressure rise resulting in a catastrophic rupture of the vehicle skin, excessive temperatures that burn or incapacitate the crew (due to hyperthermia), carbon dioxide build-up or accumulation of other combustion products (e.g. carbon monoxide). The previous work introduced a simplified model that treated the fire primarily as a source of heat and combustion products and sink for oxygen prescribed (input to the model) based on terrestrial standards. The model further treated the spacecraft as a closed system with no capability to vent to the vacuum of space. The model in the present work extends this analysis to more realistically treat the pressure relief system(s) of the spacecraft, include more combustion products (e.g. HF) in the analysis and attempt to predict the fire spread and limiting fire size (based on knowledge of terrestrial fires and the known characteristics of microgravity fires) rather than prescribe them in the analysis. Including the characteristics of vehicle pressure relief systems has a dramatic mitigating effect by eliminating vehicle overpressure for all but very large fires and reducing average gas-phase temperatures.

combustion↗

Camp Fire processed Landsat 8 images, pre-fire, during-fire, post-fire

The Camp Fire rapidly spread across a landscape in Butte County, California, toward the city of Paradise in the early morning hours of 8 November 2018. GEE acquires L8 data products from USGS that include Real-Time Tier 1 DN values, representing scaled, calibrated at-sensor radiance, and Level-1 Precision Terrain (L1TP) processing. We carried out additional processing on the pre- and post-fire images, including an illumination correction to account for effects of steep topography, and radiometric normalization to ensure homogeneity between images. We also identified and processed high-quality images for both the pre-fire condition(25 Oct 2013), and the post-fire burn scar (26 Dec 2018). Using the tools we provided in the paper, we estimate that, over the first hour, the Camp Fire was consuming ~200 ha/minute of vegetation with a linear spread rate of 14 km over the fire’s first 25 minutes, or ~33km/hr. We briefly discuss broader use of remote sensing and geospatial analysis for fire research and risk management. A visualization app (sliderApp) that includes pre-fire, active fire, and post-fire images: https://caralyngorman.users.earthengine.app/view/camp-fire-sliding-map-3-9-19

54 ENVIRONMENTAL SCIENCES↗

Impingement effect of service module reaction control system engine plumes. Results of service module reaction control system plume model force field application to an inflight Skylab mission proximity operation situation with the inflight Skylab response

Plume impingement effects of the service module reaction control system thruster firings were studied to determine if previous flight experience would support the current plume impingement model for the orbiter reaction control system engines. The orbiter reaction control system is used for rotational and translational maneuvers such as those required during rendezvous, braking, docking, and station keeping. Therefore, an understanding of the characteristics and effects of the plume force fields generated by the reaction control system thruster firings were examined to develop the procedures for orbiter/payload proximity operations.

Lobb, J. D., Jr.↗

Regional patterns of postwildfire streamflow response in the Western United States: The importance of scale‐specific connectivity

Abstract Wildfires can impact streamflow by modifying net precipitation, infiltration, evapotranspiration, snowmelt, and hillslope run‐off pathways. Regional differences in fire trends and postwildfire streamflow responses across the conterminous United States have spurred concerns about the impact on streamflow in forests that serve as water resource areas. This is notably the case for the Western United States, where fire activity and burn severity have increased in conjunction with climate change and increased forest density due to human fire suppression. In this review, we discuss the effects of wildfire on hydrological processes with a special focus on regional differences in postwildfire streamflow responses in forests. Postwildfire peak flows and annual water yields are generally higher in regions with a Mediterranean or semi‐arid climate (Southern California and the Southwest) compared to the highlands (Rocky Mountains and the Pacific Northwest), where fire‐induced changes in hydraulic connectivity along the hillslope results in the delivery of more water, more rapidly to streams. No clear streamflow response patterns have been identified in the humid subtropical Southeastern United States, where most fires are prescribed fires with a low burn severity, and more research is needed in that region. Improved assessment of postwildfire streamflow relies on quantitative spatial knowledge of landscape variables such as prestorm soil moisture, burn severity and correlations with soil surface sealing, water repellency, and ash deposition. The latest studies furthermore emphasize that understanding the effects of hydrological processes on postwildfire dynamic hydraulic connectivity, notably at the hillslope and watershed scales, and the relationship between overlapping disturbances including those other than wildfire is necessary for the development of risk assessment tools.

Hallema, Dennis W.↗

Annealing Temperature and Initial Iron Valence Ratio Effects on the Structural Characteristics of Nanoscale Nickel Zinc Ferrite

Nickel zinc ferrite (NZFO) nanoparticles were synthesized via a reverse micelle method with a nonionic surfactant. Three different initial Fe{sup 3+}/Fe{sup 2+} ratios were employed along with three different firing temperatures (200, 500, 1000 C) to investigate the effects on the NZFO system. Extended x-ray absorption fine structure (EXAFS) results reveal zinc loss at high annealing temperatures; at 1000 C, the loss is nearly total for Fe{sup 3+}/Fe{sup 2+} ratios other than 10:90. Annealing at 500 C, however, appears necessary for fully incorporating the zinc and nickel into the spinel phase. The best nanoferrite was thus obtained using an initial Fe{sup 3+}/Fe{sup 2+} ratio of 10:90 and a moderate firing temperature of 500 C. This sample exhibits a room temperature saturation magnetization of 58 emu/g as measured via vibrating sample magnetometry, comparable with bulk values and greater than that of confirmed nano-NZFOs found in the literature. EXAFS also indicates that in all cases in which the elements adopted a spinel structure, the nickel occupies only octahedral sites and the zinc primarily tetrahedral sites.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MSL-2 accelerometer data results

The Materials Science Laboratory-2 (MSL-2) mission flew the Marshall Space Flight Center-developed Linear Triaxial Accelerometer (LTA) on the Space Transportation System (STS) 61-C Shuttle mission launched January 21, 1986. Flight data were analyzed to verify the quietness of the MSL carrier and to characterize the acceleration environment for future MSL users. The MSL was found to introduce no significant experiment acceleration; and the effects of crew treadmill exercise, Orbiter vernier engine firings, and other routine flight occurrences were established. The LTA was found to be well suited for measuring nominal to very quiet STS acceleration levels at frequencies below 50 Hz. Special processing was used to examine the low-frequency spectrum and to establish the effective rms amplitude associated with dominant frequencies.

Henderson, Fred↗

Effects of a Layered Morphology on Drip Suppression in Burning Polymers

Fire safety in polymers is critically important with products such as textiles and consumer goods, as well as materials used in construction, aerospace, transportation, and furniture. Additives used as anti-dripping and flame-retardant agents impose acute human health issues and have negative environmental impacts. With a focus on developing additive-free solutions, here we used multilayer coextrusion to fabricate layered polyethylene/polypropylene (PE/PP) films and investigated the effect of a layered morphology on dripping and burning rates. The experimental results for multilayered PE/PP samples were compared to control groups of melt blended PE/PP samples. The multilayer configuration provides two significant advantages: 154% delay in the time to the first drip and up to 87% reduction in the number of drips compared to the value for the melt blended samples with no additives. PE/PP blends with up to 2 wt % polytetrafluoroethylene, a commonly used anti-dripping agent in the industry, showed only 85% delay in the time to the first drip and about 60% reduction in the number of drips. We discovered a linear relationship between film thickness and burning rate, which allows for the use of the volumetric burning rate to normalize the effect of film thickness. No benefit in the burning rate was observed when comparing multilayered structures and conventional melt blended architectures or blends with PTFE. Annealing studies and transmission electron microscopy at areas close to the combustion zones confirmed that higher extensional viscosities induced by the layered structures and morphological changes due to the layer breakup play an important role in reducing dripping. By combining the first drip time and overall drip numbers, a parameter, “dripping index”, was defined to establish a fire safety map to simplify material comparisons. This study demonstrates that a multilayer film geometry can provide an additive-free solution to yield control over fire safety parameters in polymers.

36 MATERIALS SCIENCE↗

Effects of boron and glass hybrid epoxy-composites on graphite-fiber release in an aircraft fire

Recent studies have shown that the benefits gained by using graphite-epoxy composite structures may not be realized without some risk. The graphite fibers are very good electrical conductors and fibers released into the environment during a fire create a possible hazard to electrical equipment. Several graphite-epoxy hybrids were exposed to a fire and simulated explosion and their graphite fiber retention characteristics were examined. Several low melting-temperature glasses which wet and clump graphite-fibers and a glass/graphite fabric which reduced impact damage were identified as promising hybridizing components to minimize graphite fiber release.

Tompkins, S. S.↗

Recovery of a Charred Painting Using Atomic Oxygen Treatment

A noncontact method is described which uses atomic oxygen to remove soot and char from the surface of a painting. The atomic oxygen was generated by the dissociation of oxygen in low pressure air using radio frequency energy. The treatment, which is an oxidation process, allows control of the amount of material to be removed. The effectiveness of char removal from half of a fire-damaged oil painting was studied using reflected light measurements from selected areas of the painting and by visual and photographic observation. The atomic oxygen was able to effectively remove char and soot from the treated half of the painting. The remaining loosely bound pigment was lightly sprayed with a mist to replace the binder and then varnish was reapplied. Caution should he used when treating an untested paint medium using atomic oxygen. A representative edge or corner should he tested first in order to determine if the process would be safe for the pigments present. As more testing occurs, a greater knowledge base will be developed as to what types of paints and varnishes can or cannot be treated using this technique. With the proper precautions, atomic oxygen treatment does appear to be a technique with great potential for allowing very charred, previously unrestorable art to be salvaged.

Rutledge, Sharon K.↗

Analysis of the Shattered Pellet Injection Fragment Plumes Generated by Machine Specific Shatter Tube Designs

Shattered pellet injector systems have been installed on DIII-D, JET, and KSTAR and used to experimentally determine the effectiveness of the shattered pellet injection (SPI) process in mitigating the deleterious effects of a tokamak plasma disruption. Pellets are fired, and before entering the plasma, strike a bent tube known as a shatter tube causing the pellet to shatter. The process of pellet fragmentation is a chaotic process that can be described in terms of fragment size distribution through a statistical model that incorporates the effects of the pellet material and impact characteristics. In addition to the fragment size distribution, the shatter plume has other characteristics of interest, such as a fragment velocity distribution and temporal mass evolution. The fragment velocity distribution is important because it is needed to accurately model the spread and location of the ablation and the deposition of impurities in the plasma over time. The temporal mass evolution is necessary to determine the time-resolved delivery of mass to the plasma.Due to installation constraints, the shatter tube currently installed on JET has a unique geometry with a modest S-bend followed by a 20-deg bend at the end of the tube. The DIII-D and KSTAR shatter tube design is a simple tube bent through an angle of 20 deg followed by a straight section. The resulting shatter sprays from the JET shatter tube and a 20-deg miter bend shatter tube were experimentally characterized for various pellet materials and speeds. Laboratory testing of these shatter tubes allows for the use of fast cameras to capture the fragment spray traveling through a large vacuum chamber. These high-speed videos of the shatter plumes allow the fragment size distribution, temporal mass evolution, and velocity distribution of the fragments within the plume to be determined. Overall, this paper presents a comparison of the unique geometry of the JET shatter tube to the miter bend geometries used for shattering and some insight into the variables that may be adjusted to produce the optimal shatter spray. The impact of entrained propellant gas on the resulting shatter spray was examined during testing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Energy Improvements of Fire Station 71

Since 2018, the City of Shawnee, Kansas has completed two phases of the State of Kansas Facility Conservation Improvement Program (FCIP), an initiative that guarantees operational cost and energy savings through targeted construction improvements on City facilities and infrastructure. The City is currently in the third phase of this FCIP, where one of the projects included an investment in energy improvements for Fire Station 71 (FS 71). The City partnered with Navitas, an Energy Service Company (ESCO), to implement a Photovoltaic Solar Array on FS71. The purpose of this project was to invest in sustainable building improvements with Energy Conservation Measures (ECM) to bring cost savings to the City and to provide sustainable benefits to the residents of Shawnee. In the first task of the project, Navitas collaborated with the City of Shawnee and the Community Development Department to determine the optimal layout and schedule for the installation of the solar array on FS 71. In the second task of the project, Navitas installed the 99.8 kW DC Photovoltaic solar array system. This system installation comprised of racking, inverters, optimizers, load center, and disconnect, which were all installed at a total ECM price of $\$$247,948. The third task focused on start-up and commissioning of the array. Navitas installed a real-time data analytics information management system integrated with utility meters, which evaluates the operations of the utility system and verifies operation of equipment and ensures optimum operation for energy efficiency. In the final task of this project, this analytics system was used for monitoring and verification, which will continue to be used to evaluate the success of the project for the coming years. The primary goal of the project was to install the 99.8 kW DC PV solar array at FS 71 to demonstrate the viability of solar energy systems in essential municipal facilities. Fire stations are energy demanding structures, as they require a constant intake of power and have a high baseline energy usage. The success of solar arrays on a fire station exemplifies their energy efficiency and effectiveness and displays their potential for application on other city facilities. By installing a solar array at such a facility, the City sought not only to offset electricity usage but also to serve as a model for ECMs in other municipal facilities and infrastructure projects. From an economic standpoint, this project demonstrates the feasibility of renewable energy at the municipal level. The total project cost of $\$$247,948 was split evenly between city funds and award funding, minimizing financial risk while ensuring guaranteed long-term savings. Any excess savings that are beyond the guaranteed minimums remain with the city, which enables future investment in sustainable energy initiatives. This project provides many benefits to the public. In addition to reducing the environmental footprint of city operations, it lowers taxpayer-funded utility spending and improves the energy security of a critical facility. The knowledge gained from this implementation motivates the City to focus on similar efforts across other public facilities in future FCIP phases and other City projects.

14 SOLAR ENERGY↗

Hanford Site Post-Fire Vegetation Monitoring Report for Calendar Year 2025

The Hanford Site and the surrounding greater Columbia Basin is comprised of an expanse of shrub-steppe habitats that provides exceptional ecological value to plants and animals. The U.S. Department of Energy, Hanford Field Office (HFO)-managed portion of the Hanford Site, referred to from herein as Central Hanford, has experienced repeated wildfires resulting in profound, often adverse, effects on the landscape. This report summarizes these fires and fire monitoring efforts that occurred in calendar year (CY) 2025 and analyzes the post-fire vegetation recovery in restored areas to inform future post-fire response actions.

54 ENVIRONMENTAL SCIENCES↗

TA-54 (Area G) Risk Assessment from Extreme Wildfire Scenarios

Los Alamos National Laboratory (LANL) and surrounding areas have been exposed to at least four significant wildfires since 1977 and there have been numerous others within 50 miles of LANL. Based on this history, wildfires are considered a risk to LANL facilities and their contents. While many LANL facilities are at risk to wildfire to some degree, they are found in a wide variety of conditions, thus they have varying sensitivities to wildfires. Additionally, LANL facilities have various functions and different assets, so they have a wide range of values or consequences if compromised. Therefore, determining the risks and precautions that are warranted to mitigate these risks must be done on a case-by-case basis. In an effort to assess possible wildfire risks to sensitive materials stored in a Perma-Con ® in dome TA-54-0375, a conventional fire risk analysis was performed. This conventional risk analysis is documented in Engineering Evaluation Form AP-FIRE-001-FM1, which is dated 9/28/2015 and was titled ‘Wildland Fire Exposure Evaluation for Building TA-54-0375’ (Hall 2015). This analysis acknowledged that there was significant chance of wildfire in the vicinity of TA-54-0375, but the amount of combustible material surrounding the building was deemed low. The wildland fuels that were closest to the building were largely fine fuels and were not expected to have significant duration of heat release. The prevailing winds at this location are from the south and southwest and the nearest significant upwind fuels (tree crowns or unmown grasses) are at least 300 feet away. Based on these factors the conventional wildland fire risk to TA-54-0375 was deemed minimal, “Acceptable As Is, No Action Required.” This risk evaluation was based on a combined assessment of low probability of wildfires arriving at the site from other directions (where higher fuel loadings might be present) as well as the effective setback of fuels in the direction that fire is expected to arrive from.

59 BASIC BIOLOGICAL SCIENCES↗

Removing Arsenic from Contaminated Drinking Water in Rural Bangladesh: Recent Fieldwork Results and Policy Implications

ARUBA (Arsenic Removal Using Bottom Ash) has proven effective at removing high concentrations of arsenic from drinking water in Bangladesh. During fieldwork in four sub-districts of the country, ARUBA reduced arsenic levels ranging from 200 to 900 ppb to below the Bangladesh standard of 50 ppb. The technology is cost-effective because the substrate--bottom ash from coal fired power plants--is a waste material readily available in South Asia. In comparison to similar technologies, ARUBA uses less media for arsenic removal due to its high surface area to volume ratio. Hence, less waste is produced. A number of experiments were conducted in Bangladesh to determine the effectiveness of various water treatment protocols. It was found that (1) ARUBA removes more than half of the arsenic from water within five minutes of treatment, (2) ARUBA, that has settled at the bottom of a treatment vessel, continues to remove arsenic for 2-3 days, (3) ARUBA's arsenic removal efficiency can be improved through sequential partial dosing (adding a given amount of ARUBA in fractions versus all at once), and (4) allowing water to first stand for two to three days followed by treatment with ARUBA produced final arsenic levels ten times lower than treating water directly out of the well. Our findings imply a number of tradeoffs between ARUBA's effective arsenic removal capacity, treatment system costs, and waste output. These tradeoffs, some a function of arsenic-related policies in Bangladesh (e.g., waste disposal regulations), must be considered when designing an arsenic removal system. We propose that the most attractive option is to use ARUBA in communityscale water treatment centers, installed as public-private partnerships, in Bangladeshi villages.

54 ENVIRONMENTAL SCIENCES↗

Grand Valley Ecological Forecasting : Assessing Trends in Pinyon-Juniper Habitat Relative to Drought, Beetle Infestation, Wildland Fires, and Treatment to Plan Future Management Strategies

Drought, beetle infestation, and more frequent wildfires are changing the composition and distribution of the pinyon-juniper woodland and sagebrush ecosystems of the Grand Valley in western Colorado. Land managers must consider short- and long-term goals for restoration as well as budgetary and personnel limitations after such disturbances. Satellite remote sensing can provide long-term and continuous vegetation monitoring to assess where restoration is needed most and where treatment practices are most likely to succeed. Harnessing Earth observation data, our team set out to observe trends in disturbances and the distribution of pinyon-juniper woodlands and sagebrush communities of National Park Service (NPS) and Bureau of Land Management (BLM) lands within the Grand Valley. We used imagery from the Moderate Resolution Imaging Spectroradiometer (MODIS) aboard the Aqua and Terra satellites, and Landsat sensors to map landcover change within these ecosystems from 1984-2021. Additionally, we analyzed disturbed areas and treatment sites to understand their effect on long-term vegetation health and recovery. Results showed that pinyon-juniper woodland has expanded in extent more than other landcover types, indicating woody encroachment into sagebrush ecosystems. We also found that wildfire disturbances had lasting impacts up to 20 years post-disturbance. Pre-fire treatment practices showed mixed results regarding their effectiveness at stopping fires and promoting post-fire recovery. These results will provide context to public land managers in the Grand Valley when developing management plans, ecological monitoring locations, and implementing treatment practices for future disturbances.

Garrett Powers↗