Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fan efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Co 2 Mo 6 S 8 Catalyzes Nearly Exclusive Electrochemical Nitrate Conversion to Ammonia with Enzyme-like Activity

Electrocatalytic nitrate to ammonia conversion is a key reaction for energy and environmental sustainability. This reaction involves complex multi electron and proton transfer steps, and is impeded by the lack of catalyst for promoting both reactivity and ammonia selectivity. Here, we demonstrate active motifs based on the Chevrel phase Co 2 Mo 6 S 8 exhibit an enzyme-like high turnover frequency of ~95.1 s –1 for nitrate electroreduction to ammonia. We reveal strong synergy of multiple binding sites on this catalyst, such that the ligand effect of Co steers H ad* toward hydrogenation other than hydrogen evolution, the ensemble effect of Co, and the spatial confinement effect that promote the full hydrogenation of NO x to ammonia without N–N coupling. The catalyst exhibits almost exclusive ammonia conversion with a Faradaic efficiency of 97.1% and ammonia yielding rate of 115.5 mmol·g cat –1 ·h –1 in neutral electrolytes. The high activity was also confirmed in electrolytes with dilute nitrate and high chloride concentrations.

36 MATERIALS SCIENCE↗

Decoding Active Sites for Highly Efficient Semihydrogenation of Acetylene in Palladium–Copper Nanoalloys

Accurately decoding the three-dimensional atomic structure of surface active sites is essential yet challenging for a rational catalyst design. Here, we used comprehensive techniques combining the pair distribution function and reverse Monte Carlo simulation to reveal the surficial distribution of Pd active sites and adjacent coordination environment in palladium-copper nanoalloys. After the fine-tuning of the atomic arrangement, excellent catalytic performance with 98% ethylene selectivity at complete acetylene conversion was obtained in the Pd 34 Cu 66 nanocatalysts, outperforming most of the reported advanced catalysts. Further, t he quantitative deciphering shows a large number of active sites with a Pd-Pd coordination number of 3 distributed on the surface of Pd 34 Cu 66 nanoalloys, which play a decisive role in highly efficient semihydrogenation. This finding not only opens the way for guiding the precise design of bimetal nanocatalysts from atomic-level insight but also provides a method to resolve the spatial structure of active sites.

36 MATERIALS SCIENCE↗

Development of near-optimal advanced control sequences for chiller plants with water-side economizers in U.S. Climates (ASHRAE RP-1661)

Various advanced control sequences for chiller plants with water-side economizers (WSE) have been proposed in literature, but the evaluation and optimization of those controls is limited. It is possible to maximize energy savings by selecting different sequences and related parameters based on the plant configuration, load, and climate. This paper addresses this gap by developing near-optimal advanced control sequences for chiller plants with WSEs. First, advanced control sequences for chiller plants with WSEs are categorized into condenser water, chilled water, and hybrid controls and representative sequences from each category are identified. Next, 504 different scenarios are optimized. These scenarios represent all possible combinations of two plant configurations, a constant or variable load profile, three advanced control sequences, and seven optimization parameter combinations in six climate zones. The results show the recommended near-optimal sequences can reduce energy consumption by up to 15% relative to the baseline depending on the configuration, load profile, and climate. Specifically, the CW-CHW sequence is recommended for the majority of systems because it is often the most energy efficient and/or reduces the runtime of chillers. The methodology in this paper provides practical guidance for achieving energy savings through near-optimal control of chiller plants with WSEs.

42 ENGINEERING↗

Improved components for engine fuel savings

NASA programs for developing fuel saving technology include the Engine Component Improvement Project for short term improvements in existing air engines. The Performance Improvement section is to define component technologies for improving fuel efficiency for CF6, JT9D and JT8D turbofan engines. Sixteen concepts were developed and nine were tested while four are already in use by airlines. If all sixteen concepts are successfully introduced the gain will be fuel savings of more than 6 billion gallons over the lifetime of the engines. The improvements include modifications in fans, mounts, exhaust nozzles, turbine clearance and turbine blades.

Antl, R. J.↗

Rotor redesign for a highly loaded 1800 ft/sec tip speed fan. 3: Laser Doppler velocimeter report

Laser Doppler velocimeter (LDV) techniques were employed for testing a highly loaded, 550 m/sec (1800 ft/sec) tip speed, test fan stage, the objective to provide detailed mapping of the upstream, intrablade, and downstream flowfields of the rotor. Intrablade LDV measurements of velocity and flow angle were obtained along four streamlines passing through the leading edge at 45%, 69%, 85%, and 95% span measured from hub to tip, at 100% of design speed, peak efficiency; 100% speed, near surge; and 95% speed, peak efficiency. At the design point, most passages appeared to have a strong leading edge shock, which moved forward with increasing strength near surge and at part speeds. The flow behind the shock was of a complex mixed subsonic and supersonic form. The intrablade flowfields were found to be significantly nonperiodic at 100% design speed, peak efficiency.

Harvey, W. B.↗

The future of high efficiency solar cells

Research approaches to obtain solar cell modules with 1 sun efficiencies of 20-30 percent at air mass 1 are now well understood. Such high efficiency modules should become available in the near future. It can be expected that these modules will be extensively used in terrestrial power generation, space power generation, and consumer electronics. To achieve practical module efficiencies significantly above 30 percent, it will be necessary to employ concepts other than spectral splitting, such as spectral compression and broad band detection. A major breakthrough in these areas is not anticipated at this time.

Fan, J. C. C.↗

Measurements of the unsteady flow field within the stator row of a transonic axial-flow fan. Part 2: Results and discussion

Unsteady velocity field measurements made within the stator row of a transonic axial-flow fan are presented. Measurements were obtained at midspan for two different stator blade rows using a laser anemometer. The first stator row consists of double circular-arc airfoils with a solidity of 1.68. The second features controlled-diffusion airfoils with a solidity of 0.85. Both were tested at design-speed peak efficiency conditions. In addition, the controlled-diffusion stator was also tested at near stall conditions. The procedures developed here are used to identify the rotor wake generated and unresolved unsteadiness from the velocity measurements (rotor wake generated unsteadiness refers to the unsteadiness generated by the rotor wake velocity deficit and unresolved unsteadiness refers to all remaining unsteadiness which contributes to the spread in the distribution of velocities such as vortex shedding, turbulence, etc.). Auto and cross correlations of these unsteady velocity fluctuations are presented to show their relative magnitude and spatial distributions. Amplification and attenuation of both rotor wake generated and unresolved unsteadiness are shown to occur within the stator blade passage.

Hathaway, M. D.↗

Measurements of the unsteady flow field within the stator row of a transonic axial-flow fan. II - Results and discussion

Unsteady velocity field measurements made within the stator row of a transonic axial-flow fan are presented. Measurements were obtained at midspan for two different stator blade rows using a laser anemometer. The first stator row consists of double circular-arc airfoils with a solidity of 1.68. The second features controlled-diffusion airfoils with a solidity of 0.85. Both were tested at design-speed peak efficiency conditions. In addition, the controlled-diffusion stator was also tested at near stall conditions. The procedures developed here are used to identify the rotor wake generated and unresolved unsteadiness from the velocity measurements (rotor wake generated unsteadiness refers to the unsteadiness generated by the rotor wake velocity deficit and unresolved unsteadiness refers to all remaining unsteadiness which contributes to the spread in the distribution of velocities such as vortex shedding, turbulence, etc.). Auto and cross correlations of these unsteady velocity fluctuations are presented to show their relative magnitude and spatial distributions. Amplification and attenuation of both rotor wake generated and unresolved unsteadiness are shown to occur within the stator blade passage.

Hathaway, M. D.↗

Motor Configuration Selection for A New Technical Challenge to Develop A 5 MW Cryogenic Motor and Drive

Due to aviation’s appreciable and growing share of humanity’s impact on our environment and estimates that CO2emissions only account for 34% of aviation’s total effective radiative forcing [1], there is a need to reach beyond climate goals that focus only on CO2emissions, such as the US Aviation Climate Action Plan’s [3] goal to reach net-zero carbon emissions by 2050.There is motivation to develop technology that pushes toward future large transport aircraft with net zero climate impact that are highly electrified (i.e., have higher power electrical propulsion system components). This paper describes a new, 6-year technical challenge to address this need by developing a 5 MW superconducting motor and cryogenic drive. Section 1 will detail the motivation for this work. Section 2 will describe the technical challenge and the selected specifications for the motor. Section 3 will present the results of a motor configuration trade study and the down selection of one configuration to develop a detailed design for. The technical challenge focuses on the design of a5 MW superconducting motor and cryogenic drive and demonstration of it at a 2+ MW scale to achieve TRL 3. Both fully superconducting (superconducting stator and rotor) and fully cryogenic (superconducting rotor and cryogenic stator) machine configurations will be explored. An emphasis will be placed on addressing the key tall poles for high power superconducting machines. Further details will be included in the full paper. The requirements and goals of the motor will be detailed. The rated speed (2,000 to 3,000 rpm) is defined to be appropriate for directly driving multi-MW fans or propellers. A range of rated speed is permitted because the motor is not designed for a specific aircraft and to provide design flexibility if AC losses in the stator winding are found to be a significant constraint (i.e., a lower speed can be selected to reduce electrical frequency). Relatively conservative requirements for efficiency (99%) and specific power (20 kW/kg) are defined, because TRL advancement and pushing toward flight readiness is emphasized over performance optimization. However, more aggressive efficiency and specific power goals are specified (99.9% and 40 kW/kg). The 3rd section will present the results of a motor configuration trade study. The study started with a qualitative assessment of sixteen motor configurations based on geometric, mechanical, thermal, and electromagnetic criteria. This assessment has been completed with three evaluators scoring all nine criteria. A configuration down select was made by prioritizing the sixteen configurations into four tiers based on each configuration’s total score and consideration of manufacturability, complexity, and support hardware (e.g., rotary vacuum seals, bearings). Configurations in priority A and B will be further evaluated through quantitative assessments, whereas those in priority C will only be further evaluated if time permits and priority D will not be further evaluated. Eight of the sixteen configurations were down selected for quantitative assessment, which will include analytical calculations and low-to moderate-fidelity finite element analysis to produce a preliminary Pareto front of efficiency versus specific power for each configuration. This assessment emphasizes the calculation of AC losses in the stator winding and an exploration of thermal management approaches to remove that heat and maintain cryogenic temperature. The final paper will include a description of each motor configuration that was considered. The quantitative assessments are underway, and an assessment of one configuration is complete for multiple stator conductor options. The remaining assessments are scheduled to be completed by late March so that the final down select to one configuration can be included in this paper.

Net Zero↗

A fan pressure ratio correlation in terms of Mach number and Reynolds number for the Langley 0.3 meter transonic cryogenic tunnel

Calibration data for the two dimensional test section of the Langley 0.3 Meter Transonic Cryogenic Tunnel were used to develop a Mach number-Reynolds number correlation for the fan pressure ratio in terms of test section conditions. Well established engineering relationships combined to form an equation which is functionally analogous to the correlation. A geometric loss coefficient which is independent of Reynolds number or Mach number was determined. Present and anticipated uses of this concept include improvement of tunnel control schemes, comparison of efficiencies for operationally similar wind tunnels, prediction of tunnel test conditions and associated energy usage, and determination of Reynolds number scaling laws for similar fluid flow systems.

Lawing, P. L.↗

The Cascade Effectiveness of 3-Terminal Tandem Photocathode Architectures as Applied to CO 2 Reduction

Cascade catalysis for photoelectrochemical CO 2 reduction (CO 2 R) decouples the overall reaction into sequential steps occurring on separately optimized catalysts (for example, Ag and Cu) between which an intermediate species such as CO is transferred. A 3-terminal tandem (3TT) photovoltaic architecture advantageously holds two different catalytic regions at different potentials under a single illumination source, but its overall efficiency is low. Using a stochastic reaction-diffusion model, we have examined 3TT photocathode design principles, focusing on the coupling of surface chemistry and transport of CO both inside the boundary layer and outward, into the bulk electrolyte. We find that ensuring that the lateral diffusion distance within the boundary layer is short compared to the boundary layer thickness and controlling bulk flow are key, with interdigitated designs showing an overall conversion efficiency improvement by 2 orders of magnitude compared to the side-by-side case without flow. These findings can be adapted for other cascaded architectures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct Observation of Ammonia Storage in UiO-66 Incorporating Cu(II) Binding Sites

The presence of active sites in metal–organic framework (MOF) materials can control and affect their performance significantly in adsorption and catalysis. However, revealing the interactions between the substrate and active sites in MOFs at atomic precision remains a challenging task. Here, we report the direct observation of binding of NH 3 in a series of UiO-66 materials containing atomically dispersed defects and open Cu(I) and Cu(II) sites. While all MOFs in this series exhibit similar surface areas (1111–1135 m 2 g –1 ), decoration of the -OH site in UiO-66-defect with Cu(II) results in a 43% enhancement of the isothermal uptake of NH 3 at 273 K and 1.0 bar from 11.8 in UiO-66-defect to 16.9 mmol g –1 in UiO-66-Cu II . A 100% enhancement of dynamic adsorption of NH 3 at a concentration level of 630 ppm from 2.07 mmol g –1 in UiO-66-defect to 4.15 mmol g –1 in UiO-66-Cu II at 298 K is observed. In situ neutron powder diffraction, inelastic neutron scattering, and electron paramagnetic resonance, solid-state nuclear magnetic resonance, and infrared spectroscopies, coupled with modeling reveal that the enhanced NH 3 uptake in UiO-66-Cu II originates from a {Cu(II)···NH 3 } interaction, with a reversible change in geometry at Cu(II) from near-linear to trigonal coordination. This work represents the first example of structural elucidation of NH 3 binding in MOFs containing open metal sites and will inform the design of new efficient MOF sorbents by targeted control of active sites for NH 3 capture and storage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atmosphere-biosphere exchange of CO2 and O3 in the Central Amazon Forest

An eddy correlation measurement of O3 deposition and CO2 exchange at a level 10 m above the canopy of the Amazon forest, conducted as part of the NASA/INPE ABLE2b mission during the wet season of 1987, is presented. It was found that the ecosystem exchange of CO2 undergoes a well-defined diurnal variation driven by the input of solar radiation. A curvilinear relationship was found between solar irradiance and uptake of CO2, with net CO2 uptake at a given solar irradiance equal to rates observed over forests in other climate zones. The carbon balance of the system appeared sensitive to cloud cover on the time scale of the experiment, suggesting that global carbon storage might be affected by changes in insolation associated with tropical climate fluctuations. The forest was found to be an efficient sink for O3 during the day, and evidence indicates that the Amazon forests could be a significant sink for global ozone during the nine-month wet period and that deforestation could dramatically alter O3 budgets.

Fan, Song-Miao↗

Incompressible Turbulent Wing-Body Junction Flow

The overall objective of this study is to contribute to the optimized design of fan bypass systems in advanced turbofan engines. Increasing the engine bypass ratios have provided a major boost in engine performance improvement over the last fifty years. An engine with high bypass ratio (11-16:1) such as the Advanced Ducted Propulsion (ADP) is being developed and is expected to provide an additional 25% improvement in overall efficiency over the early turbofans. Such significant improvements in overall efficiency would reduce the cost per seat mile, which is a major government and Industry challenge for the 21th century. The research is part of the Advanced Subsonic Technology (AST) program that involves a NASA, U.S. Industry and FAA partnership with the goal of a safe and highly productive global air transportation system. The immediate objective of the study is to perform numerical simulation of duct-strut interactions to elucidate the loss mechanisms associated with this configuration that is typical of advanced turbofan engines such as ADP. However, at present experimental data for a duct-strut configuration are not available. Thus, as a first step a wing-body junction flow would be studied and is the specific objective of the present study. At the outset it is to be recognized that while duct-strut interaction flow is similar to that of wing-body junction flows, there are some differences owing to the presence of a wall at both ends of the strut. Likewise, some differences are due to the sheared inflow (as opposed to a uniform inflow) velocity profile. It is however expected that some features of a wing-body junction flow would persist. Next, some of the salient aspects of the complex flow near a wing-body junction, as revealed by various studies reported in the literature will be reviewed. One of the principle characteristics of the juncture flow, is the presence of the mean flow components in a plane perpendicular to the direction of the oncoming free-stream flow. The lateral curvature of the wing/strat causes the oncoming turbulent layer to skew about am axis (x-axis) parallel to the plane (xz-plane) of the mean shear. This is the principle mechanism for the generation of secondary flow. Such skew-induced secondary flows are slow to be attenuated by Reynolds stresses. Additional contribution to the generation of secondary flow comes from anisotropies in Reynolds stresses. Upstream of the strut, the mean-vorticity is directed span wise (along the y-direction). The presence of secondary flow in the vicinity of the strut causes the vorticity to stretch around the obstacle in a horse-shoe shape, with each leg having a vorticity of the opposite sense. The blockage effect of the strut imposes a severe adverse pressure gradient on the oncoming turbulent shear layer, causing boundary layer separation ahead of the leading edge, resulting in a vortex that rolls up and flows downstream into the juncture region. The separation vortices trailing in the wake of the wing can alter the lift or drag characteristics of the surfaces downstream of the wing-body juncture. Likewise, on submarines, the wake flow behind the appendage can degrade the performance of the propeller located downstream. The complex nature of this flow is caused by the presence of all six components of Reynolds stresses. Devenport and Simpson report that in the vicinity of the horse-shoe vortex there is intense recirculation with turbulent stresses being much larger than those normally observed in turbulent flows. These features contribute to making this flow a challenge to predict numerically. Some of the past studies provide useful insights into this flow that would guide our numerical efforts. In measurements reported by Shabaka and Bradshaw, the eddy viscosity tensor is seen to be non-isotropic and has negative components in certain regions. In an effort to evaluate the closure assumptions of various turbulence models, Devenport and Simpson used their own extensive measurements in juncture flows around the nose of a wing-body junction. Measured values of mean-velocity and/or turbulence kinetic energy was used to predict the magnitude of the shear stress vector. Algebraic stress models performed the best followed by Cebeci-Smith eddy viscosity model. The flow is reported to be dominated by a pressure field produced by the wing and the velocity field generated by the horseshoe vortex that is wrapped around the junction between the wing and wall. Kubendran et al. conclude from an experimental study that the shape of leading edge of the wing as characterized by its slenderness ratio is a major factor in determining the flow fields in the juncture region. The more thinner the leading edge of the juncture, the weaker the horseshoe vortex is. Also, with a slender leading edge, the secondary flow in the juncture would be due mainly to the cross-stream gradients of Reynolds stresses rather than due to a lateral skewing of the shear layer.

Krishnamurthy, R.↗

Superconductors Enable Lower Cost MRI Systems

The future looks bright, light, and green, especially where aircraft are concerned. The division of NASA s Fundamental Aeronautics Program called the Subsonic Fixed Wing Project is aiming to reach new heights by 2025-2035, improving the efficiency and environmental impact of air travel by developing new capabilities for cleaner, quieter, and more fuel efficient aircraft. One of the many ways NASA plans to reach its aviation goals is by combining new aircraft configurations with an advanced turboelectric distributed propulsion (TeDP) system. Jeff Trudell, an engineer at Glenn Research Center, says, "The TeDP system consists of gas turbines generating electricity to power a large number of distributed motor-driven fans embedded into the airframe." The combined effect increases the effective bypass ratio and reduces drag to meet future goals. "While room temperature components may help reduce emissions and noise in a TeDP system, cryogenic superconducting electric motors and generators are essential to reduce fuel burn," says Trudell. Superconductors provide significantly higher current densities and smaller and lighter designs than room temperature equivalents. Superconductors are also able to conduct direct current without resistance (loss of energy) below a critical temperature and applied field. Unfortunately, alternating current (AC) losses represent the major part of the heat load and depend on the frequency of the current and applied field. A refrigeration system is necessary to remove the losses and its weight increases with decreasing temperature. In 2001, a material called magnesium diboride (MgB2) was discovered to be superconducting. The challenge, however, has been learning to manufacture MgB2 inexpensively and in long lengths to wind into large coils while meeting the application requirements.

Source record↗

Critical Analysis of Replacements for R-410A in Heat Pump Applications

Using low-GWP refrigerants can reduce the Green House Gas (GHG) emission of HVAC systems. Research has shown that using heat exchangers with small diameter tubes is a promising solution to meet the performance goals of heat pump using low-GWP refrigerants due to reduced refrigerant charge, reduced flammable impact and environmental impact. However, application of small diameter tube requires in-depth component design optimization to make the new system adapt to low-GWP refrigerants.In this paper, multi-objective optimizations using Particle Swarm Optimization (PSO) algorithm on a R-410A residential 5-ton air source heat pump is performed for improved system performance and reduced material cost. Five R-410A alternatives, i.e., R-32, R-454A, R-454B, R-454C and R-455A are investigated. R-455A and R-454C have GWP lower than 150. As a result of optimization, 12.4%-19.1% Energy Efficiency Ratio (EER) improvement and up to 71% HXs material cost saving is achieved. Life Cycle Climate Performance (LCCP) analysis shows that optimized systems reduce total CO2 emission by 13%-33% depending on the choice of refrigerant and climate zone.The optimal heat exchangers resulting from this research can fit into the original R-410A fan-coil units. The proposed heat pump design method establishes a production and installation path to produce cost-effective low-GWP heat pumps easily accepted by end users.

Li, Zhenning↗

Structure and Interface Design Enable Stable Li-Rich Cathode

Li-rich layered-oxide cathodes have the highest theoretical energy density among all the intercalated cathodes, which have attracted intense interests for high energy Li-ion batteries. However, O3-structured layered-oxide cathodes suffer from a low initial Coulombic efficiency (CE), severe voltage fade, and poor cycling stability because of the continuous oxygen release, structural rearrangements due to irreversible transition-metal migration, and serious side reactions between the delithiated cathode and electrolyte. In this work, we report that these challenges are migrated by using a stable O2-structured Li 1.2 Ni 0.13 Co 0.13 Mn 0.54 O 2 (O2-LR-NCM) and all-fluorinated electrolyte. The O2-LR-NCM can restrict the transition metals migrating into the Li layer and the in situ formed fluorinated cathode electrolyte interphase (CEI) on the surface of the O2-LR-NCM from the decomposition of all-fluorinated electrolyte during initial cycles effectively restrains the structure transition, suppresses the O2 release, and thereby safeguards the transition metal redox couples, enabling a highly reversible and stable oxygen redox reaction. O2-LR-NCM in all fluorinated electrolytes achieves a high initial CE of 99.82 % and cycling CE of and cycling CE of >99.9%, high reversible capacity of 278 mAh/g, and high capacity retention of 83.3% after 100 cycles. The synergic design of electrolyte and cathode structure represents a promising direction to stabilize high-energy cathodes.

25 ENERGY STORAGE↗

Influence of the air-cooled supercritical carbon dioxide recompression cycle design-point on molten salt power tower techno-economic performance

Here, this paper investigates the techno-economic performance of a molten salt power tower integrated with an air-cooled supercritical carbon dioxide recompression cycle. Prior research into the cycle design point showed trade-offs between efficiency, cost, and temperature difference across the heat input, resulting in trade-offs between the design-point generation of the molten salt power tower system and the cost of sensible-heat thermal energy storage. Prior research into cycle off-design showed that colder ambient temperature designs have higher efficiencies on cold days but lower efficiency and capacity degradation on hot days. We present a framework to evaluate how cycle design, cost, and corresponding off-design performance affect the techno-economic performance of the molten salt power tower system. We use a steady-state off-design cycle model assuming fixed shaft speeds, inventory control, and air-cooler fan power control and integrate the cycle model with the molten salt power tower model from the National Renewable Energy Laboratory's System Advisor Model. First, we present a surrogate model that uses a heuristic approach to correct the interpolation when the cycle reaches capacity limitations at ambient temperatures hotter than design. Next, we evaluate how the recompression cycle design-point ambient temperature, air-cooler approach temperature, air-cooler fan power, and recuperator conductance influence cycle and system design metrics. Finally, we complete annual simulations using an hourly "duck curve" pricing schedule and present annual performance metrics to evaluate the cumulative effects of the cycle design parameters and corresponding off-design performance on molten salt power tower techno-economics.

14 SOLAR ENERGY↗