Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error localization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Cosmological parameters degeneracies and non-Gaussian halo bias

We study the impact of the cosmological parameters uncertainties on the measurements of primordial non-Gaussianity through the large-scale non-Gaussian halo bias effect. While this is not expected to be an issue for the standard ΛCDM model, it may not be the case for more general models that modify the large-scale shape of the power spectrum. We consider the so-called local non-Gaussianity model, parametrized by the f{sub NL} non-Gaussianity parameter which is zero for a Gaussian case, and make forecasts on f{sub NL} from planned surveys, alone and combined with a Planck CMB prior. In particular, we consider EUCLID- and LSST-like surveys and forecast the correlations among f{sub NL} and the running of the spectral index α{sub s}, the dark energy equation of state w, the effective sound speed of dark energy perturbations c{sup 2}{sub s}, the total mass of massive neutrinos M{sub ν} = Σm{sub ν}, and the number of extra relativistic degrees of freedom N{sub ν}{sup rel}. Neglecting CMB information on f{sub NL} and scales k > 0.03h/Mpc, we find that, if N{sub ν}{sup rel} is assumed to be known, the uncertainty on cosmological parameters increases the error on f{sub NL} by 10 to 30% depending on the survey. Thus the f{sub NL} constraint is remarkable robust to cosmological model uncertainties. On the other hand, if N{sub ν}{sup rel} is simultaneously constrained from the data, the f{sub NL} error increases by ∼ 80%. Finally, future surveys which provide a large sample of galaxies or galaxy clusters over a volume comparable to the Hubble volume can measure primordial non-Gaussianity of the local form with a marginalized 1-σ error of the order Δf{sub NL} ∼ 2−5, after combination with CMB priors for the remaining cosmological parameters. These results are competitive with CMB bispectrum constraints achievable with an ideal CMB experiment.

79 ASTRONOMY AND ASTROPHYSICS↗

Stochastic tensor contraction for quantum chemistry

Many computational methods in ab initio quantum chemistry are formulated in terms of high-order tensor contractions, whose cost determines the size of system that can be studied. We introduce stochastic tensor contraction to perform such operations with greatly reduced cost, and present its application to the gold-standard quantum chemistry method, coupled cluster theory with up to perturbative triples. For total energy errors more stringent than chemical accuracy, we reduce the computational scaling to that of mean-field theory, while starting to approach the mean-field absolute cost, thereby challenging the existing cost-to-accuracy landscape. Benchmarks against state-of-the-art local correlation approximations further show that we achieve an order-of-magnitude improvement in both total computation time and error, with significantly reduced sensitivity to system dimensionality and electron delocalization. We conclude that stochastic tensor contraction is a powerful computational primitive to accelerate a wide range of quantum chemistry.

Chemical Physics (physics.chem-ph)↗

Electronic structure calculations with the Tran-Blaha modified Becke-Johnson Density Functional

We report a series of calculations testing the predictions of the Tran-Blaha functional for the electronic structure and magnetic properties of condensed systems. We find a general improvement in the properties of semiconducting and insulating systems, relative to calculations with standard generalized gradient approximations, although this is not always by the same mechanism as other approaches such as the quasiparticle GW method. In ZnO the valence bands are narrowed and the band gap is increased to a value in much better agreement with experiment. The Zn d states do not move to higher binding energy as they do in local-density approximation+U calculations. The functional is effective for systems with hydride anions, where correcting self-interaction errors in the 1s state is important. Similarly, it correctly opens semiconducting gaps in the alkaline-earth hexaborides. It correctly stabilizes an antiferromagnetic insulating ground state for the undoped cuprate parent CaCuO{sub 2}, but seriously degrades the agreement with experiment for ferromagnetic Gd relative to the standard local-spin-density approximation and generalized gradient approximations. This is due to positioning of the minority-spin 4f states at too low an energy. Conversely, the position of the La 4f conduction bands of La{sub 2}O{sub 3} is in reasonable accord with experiment as it is with standard functionals. The functional narrows the Fe d bands of the parent compound LaFeAsO of the iron high-temperature superconductors while maintaining the high Fe spectral weight near the Fermi energy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effective Local Geometry Descriptor for 29Si NMR Q4 Anisotropy

The nuclear shielding anisotropy, ζ, is a useful nuclear magnetic resonance (NMR) shielding tensor parameter in describing the extent of electron cloud distortion about an atom. Despite the advantages afforded by NMR in structural characterization, the relationship between ζ and local structure of an atom in high-symmetry environments, such as Si-Q 4 sites, is poorly understood. Here, we use a data-driven approach combining random forest feature ranking and the Sure Independence Screening and Sparsifying Operator (SISSO) approach to derive a simple and accurate geometric descriptor for ζ with a root-mean-squared prediction error of 6.77 ppm and an R 2 of 0.761. We then apply this descriptor to describe the local geometric distortion of zeolites Sigma-2 and silica-ZSM-5 whose chemical shift anisotropy tensor has been reported. We envision that this geometric descriptor will allow for structural description and refinement in previously difficult-to-describe materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of CT on Rails With Electronic Portal Imaging for Positioning of Prostate Cancer Patients With Implanted Fiducial Markers

Purpose: The objective of this investigation was to measure the agreement between in-room computed tomography (CT) on rails and electronic portal image (EPI) radiography. Methods and Materials: Agreement between the location of the center of gravity (COG) of fiducial markers (FMs) on CT and EPI images was determined in phantom studies and a patient cohort. A secondary analysis between the center of volume (COV) of the prostate on CT and the COG of FMs on CT and EPI was performed. Agreement was defined as the 95% probability of a difference of {<=}3.0 mm between images. Systematic and random errors from CT and EPI are reported. Results: From 8 patients, 254 CT and EPI pairs were analyzed. FMs were localized to within 3 mm on CT and EPI images 96.9% of the time in the left-right (LR) plane, 85.8% superior-inferior (SI), and 89% anterior-posterior (AP). The differences between the COV on CT and the COG on EPI were not within 3 mm in any plane: 87.8% (LR), 64.2% (SI), and 70.9% (AP). The systematic error varied from 1.2 to 2.9 mm (SI) and 1.8-2.9 mm (AP) between the COG on EPI and COV on CT. Conclusions: Considerable differences between in-room CT and EPI exist. The phantom measurements showed slice thickness affected the accuracy of localization in the SI plane, and couch sag that occurs at the CT on rails gantry could not be totally corrected for in the AP plane. Other confounding factors are the action of rotating the couch and associated time lag between image acquisitions (prostate motion), EPI image quality, and outlining uncertainties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Immobilization and Performance Status on Intrafraction Motion for Stereotactic Lung Radiotherapy: Analysis of 133 Patients

Purpose: To assess intrafractional geometric accuracy of lung stereotactic body radiation therapy (SBRT) patients treated with volumetric image guidance. Methods and Materials: Treatment setup accuracy was analyzed in 133 SBRT patients treated via research ethics board-approved protocols. For each fraction, a localization cone-beam computed tomography (CBCT) scan was acquired for soft-tissue registration to the internal target volume, followed by a couch adjustment for positional discrepancies greater than 3 mm, verified with a second CBCT scan. CBCT scans were also performed at intrafraction and end fraction. Patient positioning data from 2047 CBCT scans were recorded to determine systematic ({Sigma}) and random ({sigma}) uncertainties, as well as planning target volume margins. Data were further stratified and analyzed by immobilization method (evacuated cushion [n = 75], evacuated cushion plus abdominal compression [n = 33], or chest board [n = 25]) and by patients' Eastern Cooperative Oncology Group performance status (PS): 0 (n = 31), 1 (n = 70), or 2 (n = 32). Results: Using CBCT internal target volume was matched within {+-}3 mm in 16% of all fractions at localization, 89% at verification, 72% during treatment, and 69% after treatment. Planning target volume margins required to encompass residual setup errors after couch corrections (verification CBCT scans) were 4 mm, and they increased to 5 mm with target intrafraction motion (post-treatment CBCT scans). Small differences (<1 mm) in the cranial-caudal direction of target position were observed between the immobilization cohorts in the localization, verification, intrafraction, and post-treatment CBCT scans (p < 0.01). Positional drift varied according to patient PS, with the PS 1 and 2 cohorts drifting out of position by mid treatment more than the PS 0 cohort in the cranial-caudal direction (p = 0.04). Conclusions: Image guidance ensures high geometric accuracy for lung SBRT irrespective of immobilization method or PS. A 5-mm setup margin suffices to address intrafraction motion. This setup margin may be further reduced by strategies such as frequent image guidance or volumetric arc therapy to correct or limit intrafraction motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Particle-in-Cell Method for Plasmas with a Generalized Momentum Formulation, Part II: Enforcing the Lorenz Gauge Condition

In a previous paper Christlieb et al. (A particle-in-cell method for plasmas with a generalized momentum formulation, part I: Model formulation, 2024), we developed a new particle-in-cell (PIC) method for the relativistic Vlasov–Maxwell system in which the electromagnetic fields and the equations of motion for the particles were cast in terms of scalar and vector potentials through a Hamiltonian formulation. This new method evolved the potentials under the Lorenz gauge using integral equation methods. New methods to construct spatial derivatives of the potentials that converge at the same rates as the fields were also presented. The new particle method was compared against standard explicit discretizations, including the well-known FDTD-PIC method, for a range of applications involving sheaths and particle beams. Here, this paper extends this new class of methods by focusing on the enforcement the Lorenz gauge condition in both exact and approximate forms using co-located meshes. A time-consistency property of the proposed field solver for the vector potential form of Maxwell’s equations is established, which is shown to preserve the equivalence between the semi-discrete Lorenz gauge condition and the analogous semi-discrete continuity equation. Using this property, we present three methods to enforce a semi-discrete gauge condition. The first method introduces an update for the continuity equation that is consistent with the discretization of the Lorenz gauge condition. Both the finite difference and spectral implementations satisfy this discrete gauge condition to machine precision. The second approach we propose enforces a semi-discrete continuity equation using the boundary integral solution to the field equations. The potential benefit of this approach is that it eliminates spatial derivatives that appear on the particle data, namely the current density, which is often calculated by linear combinations of low-order spline basis functions. This method is ideally suited to boundary integral equation methods that invert multi-dimensional operators without dimensional splitting techniques and will be the subject of future work. The third approach introduces a gauge correcting method that makes direct use of the gauge condition to modify the scalar potential and uses local maps for both the charge and current densities. This results in a gauge error, as the maps do not enforce the continuity equation. The vector potential coming from the current density is taken to be exact, and using the Lorenz gauge, we compute a correction to the scalar potential that makes the two potentials satisfy the gauge condition. This method also enforces the gauge condition to machine precision. We demonstrate two of the proposed methods in the context of periodic domains. Problems defined on bounded domains, including those with complex geometric features remain an ongoing effort. However, this work shows that it is possible to design computationally efficient methods that can effectively enforce the Lorenz gauge condition in a non-staggered PIC formulation.

97 MATHEMATICS AND COMPUTING↗

How Accurate Is Density Functional Theory at Predicting Dipole Moments? An Assessment Using a New Database of 200 Benchmark Values

We present that dipole moments are a simple, global measure of the accuracy of the electron density of a polar molecule. Dipole moments also affect the interactions of a molecule with other molecules as well as electric fields. To directly assess the accuracy of modern density functionals for calculating dipole moments, we have developed a database of 200 benchmark dipole moments, using coupled cluster theory through triple excitations, extrapolated to the complete basis set limit. This new database is used to assess the performance of 88 popular or recently developed density functionals. The results suggest that double hybrid functionals perform the best, yielding dipole moments within about 3.6-4.5% regularized RMS error versus the reference values - which is not very different from the 4% regularized RMS error produced by coupled cluster singles and doubles. Many hybrid functionals also perform quite well, generating regularized RMS errors in the 5-6% range. Lastly, some functionals, however, exhibit large outliers, and local functionals in general perform less well than hybrids or double hybrids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Commissioning Procedures for Mechanical Precision and Accuracy in a Dedicated LINAC

Mechanical precision measurements are fundamental procedures for the commissioning of a dedicated LINAC. At our Radioneurosurgery Unit, these procedures can be suitable as quality assurance routines that allow the verification of the equipment geometrical accuracy and precision. In this work mechanical tests were performed for gantry and table rotation, obtaining mean associated uncertainties of 0.3 mm and 0.71 mm, respectively. Using an anthropomorphic phantom and a series of localized surface markers, isocenter accuracy showed to be smaller than 0.86 mm for radiosurgery procedures and 0.95 mm for fractionated treatments with mask. All uncertainties were below tolerances. The highest contribution to mechanical variations is due to table rotation, so it is important to correct variations using a localization frame with printed overlays. Mechanical precision knowledge would allow to consider the statistical errors in the treatment planning volume margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

RESIDUAL HUBBLE-BUBBLE EFFECTS ON SUPERNOVA COSMOLOGY

Even in a universe that is homogeneous on large scales, local density fluctuations can imprint a systematic signature on the cosmological inferences we make from distant sources. One example is the effect of a local underdensity on supernova cosmology. Also known as a Hubble-bubble, it has been suggested that a large enough underdensity could account for the supernova magnitude-redshift relation without the need for dark energy or acceleration. Although the size and depth of the underdensity required for such an extreme result is extremely unlikely to be a random fluctuation in an on-average homogeneous universe, even a small underdensity can leave residual effects on our cosmological inferences. It is these small underdensities that we consider here. In this paper, we show that there remain systematic shifts in our cosmological parameter measurements, even after excluding local supernovae that are likely to be within any small Hubble-bubble. We study theoretically the low-redshift cutoff typically imposed by supernova cosmology analyses and show that a low-redshift cut of z {sub 0} {approx} 0.02 may be too low based on the observed inhomogeneity in our local universe. Neglecting to impose any low-redshift cutoff can have a significant effect on the cosmological parameters derived from supernova data. A slight local underdensity, just 30% underdense with scale 70 h {sup -1} Mpc, causes an error in the inferred cosmological constant density {Omega}{sub {Lambda}} of {approx}4%. Imposing a low-redshift cutoff reduces this systematic error but does not remove it entirely. A residual systematic shift of 0.99% remains in the inferred value {Omega}{sub {Lambda}} even when neglecting all data within the currently preferred low-redshift cutoff of 0.02. Given current measurement uncertainties, this shift is not negligible and will need to be accounted for when future measurements yield higher precision.

79 ASTRONOMY AND ASTROPHYSICS↗

Entanglement phases in large- N hybrid Brownian circuits with long-range couplings

Here, we develop solvable models of large-N hybrid quantum circuits on qubits and fermions with tunable long-range power-law interactions and continuous local monitoring. These models provide analytical access to the entanglement phase diagram and error-correcting properties of many-body entangled nonequilibrium states generated by such dynamics. In one dimension, the long-range couplings are irrelevant for α > 3/2, where α is the power-law exponent, and the models exhibit a conventional measurement-induced phase transition between volume- and area-law entangled phases. For 1/2 < α < 3/2, the long-range couplings become relevant, leading to a nontrivial dynamical exponent at the measurement-induced phase transition. More interestingly, for α < 1, the entanglement pattern receives a subvolume correction for both area-law and volume-law phases, indicating that the phase realizes a quantum error correcting code whose code distance scales as L 2–2α . While the entanglement phase diagram is the same for both the interacting qubit and fermionic hybrid Brownian circuits, we find that long-range free-fermionic circuits exhibit a distinct phase diagram with two different fractal entangled phases.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ab initio calculation of the β-decay spectrum of 6 He

Here, we calculate the β spectrum in the decay of 6 He using quantum Monte Carlo methods with nuclear interactions derived from chiral effective field theory and consistent weak vector and axial currents. We work at second order in the multipole expansion, retaining terms suppressed by O(q 2 /m$^{2}_{π}$), where q denotes low-energy scales such as the reaction’s Q value or the electron energy, and m π is the pion mass. We go beyond the impulse approximation by including the effects of two-body vector and axial currents. We estimate the theoretical error on the spectrum by using four potential models in the Norfolk family of local two- and three-nucleon interactions, which have different cutoffs, fit two-nucleon data up to different energies, and use different observables to determine the couplings in the three-body force. We find the theoretical uncertainty on the β spectrum, normalized by the total rate, to be well below the permille level, and to receive contributions of comparable size from first- and second-order corrections in the multipole expansion. We consider corrections to the β decay spectrum induced by beyond-standard-model charged-current interactions in the standard model effective field theory, with and without sterile neutrinos, and discuss the sensitivity of the next generation of experiments to these interactions.

6 ≤ A ≤ 19↗

Casimir scaling and string breaking in G{sub 2} gluodynamics

We study the potential energy between static charges in G{sub 2} gluodynamics in three and four dimensions. Our work is based on an efficient local hybrid Monte Carlo algorithm and a multilevel Luescher-Weisz algorithm with exponential error reduction to accurately measure expectation values of Wilson and Polyakov loops. Both in three and four dimensions we show that at intermediate scales the string tensions for charges in various G{sub 2} representations scale with the second order Casimir. In three dimensions Casimir scaling is confirmed within 4% for charges in representations of dimensions 7, 14, 27, 64, 77, 77{sup '}, 182, and 189 and in four dimensions within 5% for charges in representations of dimensions 7, 14, 27, and 64. In three dimensions we detect string breaking for charges in the two fundamental representations. The scale for string breaking agrees very well with the mass of the created pair of glue lumps. Close to the string breaking distance Casimir scaling between adjoint and defining representation is violated by 2.5%. The analytical prediction for the continuum string tension is confirmed for the defining representation in three dimensions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Hybrid Data-Driven and Model-Based Anomaly Detection Scheme for DER Operation

This paper proposes a hybrid data and model-based anomaly detection scheme to secure the operation of distributed energy resources (DERs) in distribution grids. Data-driven autoencoders are set up at the edge device level and they use local DER operational data as inputs. The abnormal statuses are detected by analyzing reconstruction errors. In parallel, modelbased state estimation (SE) is set up at the central level and it uses system-wide models and measurements as data inputs. The anomalies are identified by analyzing measurement residuals. The hybrid scheme preserves the benefits of both data-driven and model-based analyses and thus improves the robustness and the accuracy of anomaly detection. Numerical tests based on the model of a real distribution feeder in Southern California highlight the proposed scheme's effectiveness and benefits.

anomaly detection↗

The R-factor gap in macromolecular crystallography: an untapped potential for insights on accurate structures

In macromolecular crystallography, the agreement between observed and predicted structure factors (Rcryst and Rfree) is seldom better than 20%. This is much larger than the estimate of experimental error (Rmerge). The difference between Rcryst and Rmerge is the R-factor gap. There is no such gap in small-molecule crystallography, for which calculated structure factors are generally considered more accurate than the experimental measurements. Perhaps the true noise level of macromolecular data is higher than expected? Or is the gap caused by inaccurate phases that trap refined models in local minima? By generating simulated diffraction patterns using the program MLFSOM, and including every conceivable source of experimental error, we show that neither is the case. Processing our simulated data yielded values that were indistinguishable from those of real data for all crystallographic statistics except the final Rcryst and Rfree. These values decreased to 3.8% and 5.5% for simulated data, suggesting that the reason for high R-factors in macromolecular crystallography is neither experimental error nor phase bias, but rather an underlying inadequacy in the models used to explain our observations. The present inability to accurately represent the entire macromolecule with both its flexibility and its proteinsolvent interface may be improved by synergies between small-angle X-ray scattering, computational chemistry and crystallography. The exciting implication of our finding is that macromolecular data contain substantial hidden and untapped potential to resolve ambiguities in the true nature of the nanoscale, a task that the second century of crystallography promises to fulfill.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-381: Evaluation of Calculated Dose Accuracy for Organs-At-Risk Located at Out-Of-Field in a Commercial Treatment Planning System for High Energy Photon Beams Produced From TrueBeam Accelerators

Purpose: Dose calculation accuracy for the out-of-field dose is important for predicting the dose to the organs-at-risk when they are located outside primary beams. The investigations on evaluating the calculation accuracy of treatment planning systems (TPS) on out-of-field dose in existing publications have focused on low energy (6MV) photon. This study evaluates out-of-field dose calculation accuracy of AAA algorithm for 15MV high energy photon beams. Methods: We used the EGSnrc Monte Carlo (MC) codes to evaluate the AAA algorithm in Varian Eclipse TPS (v.11). The incident beams start with validated Varian phase-space sources for a TrueBeam linac equipped with Millennium 120 MLC. Dose comparisons between using AAA and MC for CT based realistic patient treatment plans using VMAT techniques for prostate and lung were performed and uncertainties of organ dose predicted by AAA at out-of-field location were evaluated. Results: The results show that AAA calculations under-estimate doses at the dose level of 1% (or less) of prescribed dose for CT based patient treatment plans using VMAT techniques. In regions where dose is only 1% of prescribed dose, although AAA under-estimates the out-of-field dose by 30% relative to the local dose, it is only about 0.3% of prescribed dose. For example, the uncertainties of calculated organ dose to liver or kidney that is located out-of-field is <0.3% of prescribed dose. Conclusion: For 15MV high energy photon beams, very good agreements (<1%) in calculating dose distributions were obtained between AAA and MC. The uncertainty of out-of-field dose calculations predicted by the AAA algorithm for realistic patient VMAT plans is <0.3% of prescribed dose in regions where the dose relative to the prescribed dose is <1%, although the uncertainties can be much larger relative to local doses. For organs-at-risk located at out-of-field, the error of dose predicted by Eclipse using AAA is negligible. This work was conducted in part using the resources of Varian research grant VUMC40590-R.

60 APPLIED LIFE SCIENCES↗

ADoSPSiQS (Automated Detection of Symmetry-Protected Subspaces in Quantum Simulations ) [SWR-23-55]

Symmetry-protected subspaces in quantum systems are subspaces demarcated by a conserved quantity of that quantum system. We introduce two classical algorithms, which efficiently compute and elucidate features of these subspaces. The first algorithm explores the entire symmetry-protected subspace of an initial state in time complexity linear to the size of the subspace by closing local basis state-to-basis state transitions. The second algorithm determines, with bounded error, if a given measurement outcome of a dynamically-generated state is within the symmetry-protected subspace of the state in which the dynamical system is initialized. This software is paired with the paper of the same name at https://arxiv.org/pdf/2302.08586.pdf.

Rotello, Caleb↗