Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error correction.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

A verification regime for the spatial discretization of the SN transport equations

The order-of-accuracy test in conjunction with the method of manufactured solutions is the current state of the art in computer code verification. In this work we investigate the application of a verification procedure including the order-of-accuracy test on a generic SN transport solver that implements the AHOTN spatial discretization. Different types of semantic errors, e.g. removal of a line of code or changing a single character, are introduced randomly into the previously verified S{sub N} code and the proposed verification procedure is used to identify the coding mistakes (if possible) and classify them. Itemized by error type we record the stage of the verification procedure where the error is detected and report the frequency with which the errors are correctly identified at various stages of the verification. Errors that remain undetected by the verification procedure are further scrutinized to determine the reason why the introduced coding mistake eluded the verification procedure. The result of this work is that the verification procedure based on an order-of-accuracy test finds almost all detectable coding mistakes but rarely, 1.44% of the time, and under certain circumstances can fail. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Detailed Characterization of CZT Detector Response for Improved Coded-Aperture Imaging Performance

Gamma-ray imaging is a powerful method for locating and quantifying sources of radiation. The coded-aperture technique demonstrates superior angular resolution in comparison to other methods (e.g., Compton reconstruction). In this method, a mask constructed of highly attenuating material encodes the scene as a shadow pattern on a position-sensitive detector; this pattern can then be used to recreate the origin(s) of incident radiation. This is typically done through convolution of the mask and shadow patterns. Iterative methods which attempt to reconstruct the observed shadow pattern using a weighted combination of simulated patterns may also be employed. In either case, errors in event position reconstruction due to detector imperfections alter the shadow pattern and will therefore degrade system performance and may introduce imaging artifacts. These effects can be mitigated with a detailed understanding of such errors – allowing for the generation of representative simulations that include the errors and/or correction of raw imager data to remove the errors. We present a calibration process for a commercially available cadmium zinc telluride (CZT) gamma imager which provides a comprehensive characterization of the spatial and energy dependence of event reconstruction. By illuminating a mask featuring a regular grid of pinholes with a calibration source, the localized response of the detector can be measured with fine granularity. These local responses are combined to generate a full detector response map which can be used to distort simulations in a manner that is representative of the observed detector data. Details of the calibration procedure and an assessment of the impact of its end products on the performance of iterative imaging methods will be presented.

Ziock, Klaus-Peter↗

Effective empirical corrections for basis set superposition error in the def2-SVPD basis: gCP and DFT-C

With the aim of mitigating the basis set error in density functional theory (DFT) calculations employing local basis sets, we herein develop two empirical corrections for basis set superposition error (BSSE) in the def2-SVPD basis, a basis which - when stripped of BSSE - is capable of providing near-complete-basis DFT results for non-covalent interactions. Specifically, we adapt the existing pairwise geometrical counterpoise (gCP) approach to the def2-SVPD basis, and we develop a beyond-pairwise approach, DFT-C, which we parameterize across a small set of intermolecular interactions. Both gCP and DFT-C are evaluated against the traditional Boys-Bernardi counterpoise correction across a set of 3402 non-covalent binding energies and isomerization energies. We find that the DFT-C method represents a significant improvement over gCP, particularly for non-covalently-interacting molecular clusters. Furthermore, DFT-C is transferable among density functionals and can be combined with existing functionals - such as B97M-V - to recover large-basis results at a fraction of the cost.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-F-I-03: Correction of Intra-Fractional Set-Up Errors and Target Coverage Based On Cone-Beam Computed Tomography for Cervical Cancer Patients

Purpose: The purpose of this study is to investigate the patient set-up error and interfraction target coverage in cervical cancer using image-guided adaptive radiotherapy (IGART) with cone-beam computed tomography (CBCT). Methods: Twenty cervical cancer patients undergoing intensity modulated radiotherapy (IMRT) were randomly selected. All patients were matched to the isocenter using laser with the skin markers. Three dimensional CBCT projections were acquired by the Varian Truebeam treatment system. Set-up errors were evaluated by radiation oncologists, after CBCT correction. The clinical target volume (CTV) was delineated on each CBCT, and the planning target volume (PTV) coverage of each CBCT-CTVs was analyzed. Results: A total of 152 CBCT scans were acquired from twenty cervical cancer patients, the mean set-up errors in the longitudinal, vertical, and lateral direction were 3.57, 2.74 and 2.5mm respectively, without CBCT corrections. After corrections, these were decreased to 1.83, 1.44 and 0.97mm. For the target coverage, CBCT-CTV coverage without CBCT correction was 94% (143/152), and 98% (149/152) with correction. Conclusion: Use of CBCT verfication to measure patient setup errors could be applied to improve the treatment accuracy. In addition, the set-up error corrections significantly improve the CTV coverage for cervical cancer patients.

60 APPLIED LIFE SCIENCES↗

Sensitivity Analysis of Kinetic Rate-Law Parameters Used to Simulate Long-Term Weathering of ILAW Glass. Erratum

This report refers to or contains K g values for glasses LAWA44, LAWB45 and LAWC22 affected by calculations errors as identified by Papathanassiu et al. (2011). The corrected K g values are reported in an erratum included in the revised version of the original report. The revised report can be referenced as follows: Pierce E. M. et al. (2004) Waste Form Release Data Package for the 2005 Integrated Disposal Facility Performance Assessment. PNNL-14805 Rev. 0 Erratum. Pacific Northwest National Laboratory, Richland, WA, USA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Waste Form Release Calculations for the 2005 Integrated Disposal Facility Performance Assessment. Erratum

This report refers to or contains K g values for glasses LAWA44, LAWB45 and LAWC22 affected by calculations errors as identified by Papathanassiu et al. (2011). The corrected K g values are reported in an erratum included in the revised version of the original report. The revised report can be referenced as follows: Pierce E. M. et al. (2004) Waste Form Release Data Package for the 2005 Integrated Disposal Facility Performance Assessment. PNNL-14805 Rev. 0 Erratum. Pacific Northwest National Laboratory, Richland, WA, USA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Author Correction: US oil and gas system emissions from nearly one million aerial site measurements

Correction to: Naturehttps://doi.org/10.1038/s41586-024-07117-5 Published online 13 March 2024 In the version of the article initially published, several errors were present and have been corrected in the HTML and PDF versions of the article and Supplementary Information. The main results, conclusions, and our interpretations of the data remain unchanged. See the new Supplementary Information Section S15 for a more detailed description of the errors corrected and the resulting effects on the analysis. Data processing and methods corrections Overflight count correction: We previously used pre-computed source coverage data for some Carbon Mapper campaigns that was computed differently than was required for our analysis. We have re-computed Carbon Mapper source coverage based on flightline polygons and source coordinates. Transition point computation, well sites: The updated version now correctly compares the cumulative emissions distribution of simulated well site emissions with that of aerially detected sources (rather than plumes) when computing the transition point. Transition point computation, midstream: Additionally, the transition point calculation has been corrected to exclude aerially detected midstream emissions below the transition point, which was previously leading to double counting of these emissions. This error was not present for upstream (well site) emissions. Calculation errors Unit error: We corrected a specific unit conversion error affecting well site emissions in the Kairos Fort Worth dataset. Across all datasets, we also correct the conversion factor for converting from standard volume to mass for midstream emissions. Sorting error: We correct code that was applying incorrect sorting when computing correction factors to account for partial detection at well sites. Small typographical corrections were made in Fig. 1b and SI Section S4.1. Data processing and methods corrections Overflight count correction: We previously used pre-computed source coverage data for some Carbon Mapper campaigns that was computed differently than was required for our analysis. We have re-computed Carbon Mapper source coverage based on flightline polygons and source coordinates. Transition point computation, well sites: The updated version now correctly compares the cumulative emissions distribution of simulated well site emissions with that of aerially detected sources (rather than plumes) when computing the transition point. Transition point computation, midstream: Additionally, the transition point calculation has been corrected to exclude aerially detected midstream emissions below the transition point, which was previously leading to double counting of these emissions. This error was not present for upstream (well site) emissions. Calculation errors Unit error: We corrected a specific unit conversion error affecting well site emissions in the Kairos Fort Worth dataset. Across all datasets, we also correct the conversion factor for converting from standard volume to mass for midstream emissions. Sorting error: We correct code that was applying incorrect sorting when computing correction factors to account for partial detection at well sites. Small typographical corrections were made in Fig. 1b and SI Section S4.1. The following practices may help researchers conducting similar analyses avoid making similar errors: 1, Clear, accessible documentation explaining the interpretation of all columns in data input tables and all internal variables within the model, 2, Simple cross-check calculations computed before and after unit conversions.

Sherwin, Evan D↗

Radiation-Induced Error Mitigation by Read-Retry Technique for MLC 3-D NAND Flash Memory

Here, we have evaluated the Read-Retry (RR) functionality of the 3-D NAND chip of multilevel-cell (MLC) configuration after total ionization dose (TID) exposure. The RR function is typically offered in the high-density state-of-the-art NAND memory chips to recover data once the default memory read method fails to correct data with error correction codes (ECCs). In this work, we have applied the RR method on the irradiated 3-D NAND chip that was exposed with a Co-60 gamma-ray source for TID up to 50 krad (Si). Based on our experimental evaluation results, we have proposed an algorithm to efficiently implement the RR method to extend the radiation tolerance of the NAND memory chip. Our experimental evaluation shows that the RR method coupled with ECC can ensure data integrity of MLC 3-D NAND for TID up to 50 krad (Si).

3-D NAND↗

Third-order elastic constants of diamond determined from experimental data

The pressure derivatives of the second-order elastic constants (SOECs) of diamond were determined by analyzing previous sound velocity measurements under hydrostatic stress [McSkimin and Andreatch, J. Appl. Phys. 43, 294 (1972)]. Furthermore, our analysis corrects an error in the previously reported results.We present a complete and corrected set of third-order elastic constants (TOECs) using the corrected pressure derivatives, together with published data for the nonlinear elastic response of shock compressed diamond [Lang and Gupta, Phys. Rev. Lett. 106, 125502 (2011)] and it differs significantly from TOECs published previously.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structure and composition of zirconium carbide thin-film grown by ion beam sputtering for optical applications

Thin film of compound material ZrC was deposited on Si (100) wafer using ion beam sputtering method. The deposition was carried out at room temperature and at base pressure of 3×10{sup −5} Pa. X-ray photoelectron spectroscopy (XPS) measurements were performed for determining the surface chemical compositions. Grazing incidence x-ray reflectivity (GIXRR) measurements were performed to study the film thickness, roughness and density. From GIXRR curve roughness value of the film was found less than 1 nm indicating smooth surface morphology. Films density was found 6.51 g/cm{sup 3}, which is close to bulk density. Atomic force microscopy (AFM) measurements were performed to check the surface morphology. AFM investigation showed that the film surface is smooth, which corroborate the GIXRR data. Figure 2 of the original article PDF file, as supplied to AIP Publishing, contained a PDF processing error. This article was updated on 12 May 2014 to correct that error.

36 MATERIALS SCIENCE↗

A robust dynamic state estimation approach against model errors caused by load changes

Dynamic state estimation (DSE) plays an important role in power system security monitoring and online control. In practice, there are two approaches to implementing DSE. The first approach is distributed DSE, which is based on the assumption that the terminal bus of each generator can be measured by PMUs (phasor measurement units). The assumption cannot be satisfied currently, however, because PMUs usually are installed at important high-voltage buses such as 500-kV buses installed in portions of the grid overseen by the Western Electricity Coordinating Council. Another issue of this approach is that performance of DSE is vulnerable to bad measurement data. The reason for this vulnerability is that DSE is performed separately through measurements at each terminal bus, and measurements at terminal buses are the only measurement upon which DSE can rely. Therefore, important redundant measurements are not included in this approach. The second approach is centralized DSE. This approach does not have the requirement for PMU location, and redundant measurements can be considered fully. However, load changes and grid topology changes impact centralized DSE. In this paper, we propose a new approach for handling the impact of load changes on DSE. We have developed a new algorithm that includes two sequential steps. In the first step, errors caused by load changes are detected by analyzing the difference between prediction results and measured results. In the second step, once model error is detected, a model optimization procedure is run to correct the error so the state estimation error can be mitigated. Simulation results from the IEEE 68 bus system show that the proposed approach can effectively handle model errors caused by load changes.

robust dynamic state estimation, load change, powe↗

Extraction, Scrub, and Strip Test Results for the Salt Waste Processing Facility Caustic Side Solvent Extraction Solvent Sample

An Extraction, Scrub, and Strip (ESS) test was performed on a sample of Salt Waste Processing Facility (SWPF) Caustic-Side Solvent Extraction (CSSX) solvent and salt simulant to determine cesium distribution ratios (D( Cs )), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Parsons to help determine if the solvent is qualified for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D( Cs ) measured 12.5, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges. This revision was created to correct an error. The previous revision used an incorrect set of temperature correction coefficients which resulted in slight deviations from the correct D( Cs ) results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rephasing spectral diffusion in time-bin spin-spin entanglement protocols

Generating high-fidelity spin-spin entanglement is an essential task of quantum repeater networks for the distribution of quantum information across long distances. Solid-state-based spin-photon interfaces are promising candidates to realize nodes of a quantum network, but are often limited by spectral diffusion of the optical transition, which results in phase errors on the entangled states. Here, we introduce a method to correct phase errors from quasi-static frequency fluctuations after the entangled state is generated, by shelving the emitters in the excited state to refocus the unknown phase. For quasi-static frequency fluctuations, the fidelity is determined only by the lifetime of the excited state used for shelving, making it particularly suitable for systems with a long-lived shelving state with correlated spectral diffusion. Such a shelving state may be found in Kramers doublet systems such as rare-earth emitters and color centers in Si or SiC interfaced with nanophotonic cavities with a strongly frequency-dependent Purcell enhancement. Furthermore, the protocol can be used to generate high-fidelity entangled spin pairs without reducing the rate of entanglement generation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Checking Questionable Entry of Personally Identifiable Information Encrypted by One-Way Hash Transformation

Background: As one of the several effective solutions for personal privacy protection, a global unique identifier (GUID) is linked with hash codes that are generated from combinations of personally identifiable information (PII) by a one-way hash algorithm. On the GUID server, no PII is permitted to be stored, and only GUID and hash codes are allowed. The quality of PII entry is critical to the GUID system. Objective: The goal of our study was to explore a method of checking questionable entry of PII in this context without using or sending any portion of PII while registering a subject. Methods: According to the principle of GUID system, all possible combination patterns of PII fields were analyzed and used to generate hash codes, which were stored on the GUID server. Based on the matching rules of the GUID system, an error-checking algorithm was developed using set theory to check PII entry errors. We selected 200,000 simulated individuals with randomly-planted errors to evaluate the proposed algorithm. These errors were placed in the required PII fields or optional PII fields. The performance of the proposed algorithm was also tested in the registering system of study subjects. Results: There are 127,700 error-planted subjects, of which 114,464 (89.64%) can still be identified as the previous one and remaining 13,236 (10.36%, 13,236/127,700) are discriminated as new subjects. As expected, 100% of nonidentified subjects had errors within the required PII fields. The possibility that a subject is identified is related to the count and the type of incorrect PII field. For all identified subjects, their errors can be found by the proposed algorithm. The scope of questionable PII fields is also associated with the count and the type of the incorrect PII field. The best situation is to precisely find the exact incorrect PII fields, and the worst situation is to shrink the questionable scope only to a set of 13 PII fields. In the application, the proposed algorithm can give a hint of questionable PII entry and perform as an effective tool. Conclusions: The GUID system has high error tolerance and may correctly identify and associate a subject even with few PII field errors. Correct data entry, especially required PII fields, is critical to avoiding false splits. In the context of one-way hash transformation, the questionable input of PII may be identified by applying set theory operators based on the hash codes. The count and the type of incorrect PII fields play an important role in identifying a subject and locating questionable PII fields.

59 BASIC BIOLOGICAL SCIENCES↗

Publisher's Note: “Differential voltage amplification from ferroelectric negative capacitance” [Appl. Phys. Lett. 111, 253501 (2017)]

This article was originally published online on 18 December 2017. Due to a production error, the initially-published version contained several typographical errors not corrected during proof revisions, none of which affected the substance of the article. AIP Publishing apologizes for this error. All online versions of the article were corrected on 21 December 2017, and it now appears correctly in print.

99 GENERAL AND MISCELLANEOUS↗

Sources of Conservatism in Making Corrective Action Decisions at the NNSS - 20477

During the course of closing nuclear testing release sites at the Nevada National Security Site (NNSS) under the Federal Facility Agreement and Consent Order (FFACO) using the Risk-Based Corrective Action (RBCA) evaluation process, conservative assumptions and estimates were used in many phases of the work. These assumptions and estimates were agreed to during Data Quality Objective (DQO) meetings and published in the FFACO documents. However, the potential cumulative effect of these multiple sources of conservatism was not evaluated. The RBCA process ensures that corrective action decisions minimize the risk of making Type I errors (not applying corrective action to areas that exceed action levels) at the expense of making Type II errors (applying corrective action to areas that do not exceed action levels). Rather than fully characterizing the spatial distribution of contaminants throughout each site, the RBCA process uses a bounding methodology that conservatively estimates spatial boundaries beyond which contamination is not present that exceed corrective action levels. This process accepts that these boundaries may encompass areas that do not exceed corrective action levels and, therefore, may be somewhat larger than for fully characterized sites. This is justified at sites where the reduction in investigation costs are more than any potential increase in corrective action costs. To minimize the risk of making Type I errors, conservatism was used throughout the process. This study documents the many sources of conservatism used in the RBCA process. Conservatism was used in the RBCA process in determining potential receptors, determining action levels, collecting samples, converting sample results into receptor dose, and accounting for uncertainty. This provides decision-makers with a high level of confidence that unacceptable risk to receptors will not result from exposure to residual contamination outside the corrective action boundaries. However, it does not provide an estimate of the actual extent of areas exceeding action levels. This study provides an evaluation of the effects of compounding conservatism on RBCA process decisions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

On readout of vibrational qubits using quantum beats

Readout of the final states of qubits is a crucial step towards implementing quantum computation in experiment. Although not scalable to large numbers of qubits per molecule, computational studies show that molecular vibrations could provide a significant (factor 2–5 in the literature) increase in the number of qubits compared to two-level systems. In this theoretical work, we explore the process of readout from vibrational qubits in thiophosgene molecule, SCCl{sub 2}, using quantum beat oscillations. The quantum beats are measured by first exciting the superposition of the qubit-encoding vibrational states to the electronically excited readout state with variable time-delay pulses. The resulting oscillation of population of the readout state is then detected as a function of time delay. In principle, fitting the quantum beat signal by an analytical expression should allow extracting the values of probability amplitudes and the relative phases of the vibrational qubit states. However, we found that if this procedure is implemented using the standard analytic expression for quantum beats, a non-negligible phase error is obtained. We discuss the origin and properties of this phase error, and propose a new analytical expression to correct the phase error. The corrected expression fits the quantum beat signal very accurately, which may permit reading out the final state of vibrational qubits in experiments by combining the analytic fitting expression with numerical modelling of the readout process. The new expression is also useful as a simple model for fitting any quantum beat experiments where more accurate phase information is desired.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-J-235: Varian Portal Dosimetry Accuracy at Detecting Simulated Delivery Errors

Purpose: To use receiver operating characteristic (ROC) analysis to quantify the Varian Portal Dosimetry (VPD) application's ability to detect delivery errors in IMRT fields. Methods: EPID and VPD were calibrated/commissioned using vendor-recommended procedures. Five clinical plans comprising 56 modulated fields were analyzed using VPD. Treatment sites were: pelvis, prostate, brain, orbit, and base of tongue. Delivery was on a Varian Trilogy linear accelerator at 6MV using a Millenium120 multi-leaf collimator. Image pairs (VPD-predicted and measured) were exported in dicom format. Each detection test imported an image pair into Matlab, optionally inserted a simulated error (rectangular region with intensity raised or lowered) into the measured image, performed 3%/3mm gamma analysis, and saved the gamma distribution. For a given error, 56 negative tests (without error) were performed, one per 56 image pairs. Also, 560 positive tests (with error) with randomly selected image pairs and randomly selected in-field error location. Images were classified as errored (or error-free) if percent pixels with γ<κ was < (or ≥) τ. (Conventionally, κ=1 and τ=90%.) A ROC curve was generated from the 616 tests by varying τ. For a range of κ and τ, true/false positive/negative rates were calculated. This procedure was repeated for inserted errors of different sizes. VPD was considered to reliably detect an error if images were correctly classified as errored or error-free at least 95% of the time, for some κ+τ combination. Results: 20mm{sup 2} errors with intensity altered by ≥20% could be reliably detected, as could 10mm{sup 2} errors with intensity was altered by ≥50%. Errors with smaller size or intensity change could not be reliably detected. Conclusion: Varian Portal Dosimetry using 3%/3mm gamma analysis is capable of reliably detecting only those fluence errors that exceed the stated sizes. Images containing smaller errors can pass mathematical analysis, though may be detected by visual inspection. This work was not funded by Varian Oncology Systems. Some authors have other work partly funded by Varian Oncology Systems.

60 APPLIED LIFE SCIENCES↗