Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron tubes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Laboratory test data on the stability of the STIS MAMAs

STIS has two MAMA detectors systems with distinctly different tube configurations. The first (designated BAND 1) has an opaque CsI photocathode deposited on the microchannel plate (MCP) providing wavelength coverage from 1150A to 1700A. The other MAMA (designated BAND 2) has a semitransparent CS2Te photocathode deposited on the faceplate in close proximity to the input of the MCP. It covers the 1650A to 3100A bandpass and serves as a backup for the short wavelength detector. Laboratory test data indicate that both of these detectors have good sensitivity, have good uniformity and provide stable response, making each capable of collecting data with a signal-to-noise ratio in excess of 100 per Space Telescope Imaging Spectrograph (STIS) optical resolution element. Over a multiyear development effort, a substantial body of laboratory test data (more than 6 GBytes spanning more than 6 years of collection) has accumulated on more than a dozen fabricated tubes. These tests even included a few destructive evaluations to examine the limitations and operating life. In addition, analyses where conducted regarding impact caused by the specified electronic tolerances and expected changes in the Hubble Space Telescope (HST) thermal environment. Perhaps the simplest test of stability is to collect a sequence of images, each with a uniform illumination, and use these individual "flat fields" to remove the pixel-to-pixel sensitivity in the other flat fields. These sequences typically spanned 3-5 weeks of time. The detectors are very stable, allowing the pixel-to-pixel sensitivity to be removed with good precision. The STIS specification for stability is 1% (sufficient for data with a S/N = 100) over a 1 week period and 2% over 30 days. All Engineering Model Units as well as Flight Detectors tested exceeded this specification.

Joseph, Charles L.↗

Leak Mitigation in Mechanically Pumped Fluid Loops for Long Duration Space Missions

Mechanically pumped fluid loops (MPFLs) are increasingly considered for spacecraft thermal control. A concern for long duration space missions is the leak of fluid leading to performance degradation or potential loop failure. An understanding of leak rate through analysis, as well as destructive and non-destructive testing, provides a verifiable means to quantify leak rates. The system can be appropriately designed to maintain safe operating pressures and temperatures throughout the mission. Two MPFLs on the Mars Science Laboratory Spacecraft, launched November 26, 2011, maintain the temperature of sensitive electronics and science instruments within a -40 deg C to 50 deg C range during launch, cruise, and Mars surface operations. With over 100 meters of complex tubing, fittings, joints, flex lines, and pumps, the system must maintain a minimum pressure through all phases of the mission to provide appropriate performance. This paper describes the process of design, qualification, test, verification, and validation of the components and assemblies employed to minimize risks associated with excessive fluid leaks from pumped fluid loop systems.

thermal controls↗

Mineralogical, Elemental, and Tomographic Reconnaissance Investigation for CLPS (METRIC)

METRIC is a robotic science laboratory that can determine the mineralogy, elemental chemistry, micromorphology, and thermophysical properties of planetary regolith. The METRIC suite comprises METRIC XRD/F, an X-ray diffraction/X-ray fluorescence instrument that can determine the mineralogy and elemental chemistry of regolith samples; METRIC XCT, a micro X-ray computed tomography instrument that can be used to evaluate grain/crystallite sizes and textures; METRIC IRS, an imaging spectrometer mounted on a rover that can determine mineralogy and thermophysical properties at the landing site; and a pneumatic sample collection, processing, distribution system developed by Honeybee Robotics. The payload elements could be deployed on a static lander or a rover. Data returned from the METRIC payload would inform origin, formation, and evolution of rocky planetary bodies. METRIC XRD/F draws on heritage from the CheMin instrument on the Mars Science Laboratory (MSL) Curiosity rover [1], with a few important improvements. Like CheMin, METRIC XRD/F operates in transmission geometry and uses piezoelectric actuators on sample cells in a tuning fork geometry to induce convective grain motion of the regolith to create a randomly oriented powder. MSL CheMin uses an energy-sensitive CCD to collect XRD patterns and XRF spectra simultaneously from the same sample cell, resulting in qualitative XRF data. METRIC XRD/F uses two different sample cells, one optimized for XRD and one optimized for XRF, and a silicon drift detector to detect fluoresced X-rays. This improvement to the XRF capabilities provides quantitative geochemical data of major elements down to Z = 11 and allows for the detection of minor and trace elements that are critical for evaluating geologic evolution of the Moon (e.g., P and Th). Modest improvements to the XRD geometry and hardware allow for better angular resolution and the ability to distinguish between members of the pyroxene group. METRIC XCT uses the same geometry and much of the same hardware as METRIC XRD/F, where a CCD would capture images of a regolith sample in a 3 mm diameter sample tube that is rotated 360° in steps <1°. Image brightness can be used to infer compositional data, where brighter materials indicate a higher Z, much like scanning electron microscopy. Data from METRIC XCT complement those from METRIC XRD/F. Particle size, shape, and texture can provide petrologic and provenance information, whereas vesicle size and morphology in volcanic or impact melt lithologies can inform cooling rates. METRIC IRS is a hyperspectral thermal imager that can be mounted to a lander or rover to provide mineralogical data from the broader landing site and help determine whether the samples analyzed by METRIC XRD/F and XCT are representative. The METRIC IRS spectral range (8–14 μm) and resolution (10.8 cm-1) allow for quantitative mineralogy from modelling Reststrahlen bands of major rock-forming minerals (e.g., silicates, phosphates). Radiance cubes can be processed and modelled with an onboard high-performance computer to determine mineral abundances of plagioclase, high-Ca pyroxene, pigeonite, orthopyroxene, olivine, and glass. Regolith samples can be acquired, processed, and delivered to the X-ray instruments via multiple sample handling systems, but the pneumatic sampling systems developed by Honeybee Robotics [e.g., 2] are best suited for relatively low-cost missions that are being competed for the Moon (e.g., NASA’s Payloads and Research Investigations for the Surface of the Moon program). There are pneumatic sampling systems that collect surface material and other systems that pneumatically drill up to ~1 m below the surface, providing material that has not been space weathered and has not been affected by the lander’s exhaust. [1] Blake, D. F., Vaniman, D., Achilles, C., Anderson, R., Bish, D., et al. (2012). Space Sci. Rev. 170, 341-478. https://doi.org/10.1007/s11214-012-9905-1. [2] Zacny, K., Betts, B., Hedlund, M., Long, P., Gramlich, M., Tura, K., Chu, P., Jacob, A., Garcia, A. (2014). IEEE Aerospace Conference, 3-7 March 2014, Big Sky, MT, U.S.A.

X-ray diffraction↗

Vacuum microelectronics for beam power and rectennas

Vacuum Microelectronic devices can be described as vacuum transistors or micro-miniature vacuum tubes, as one chooses. The fundamental reason behind this new technology is the very large current densities available from field emitters, namely as high as 10(8) A/sq cm. Array current densities as high as 1000 A/sq cm have been measured. Total electron transit times from source to drain for 1 micron feature size devices have been predicted to be about 150fs. This very short transit time implies the possibility of submillimeter wave transmitters and rectennas in devices which can operate with reasonably high voltages and which are small in size and are lightweight. In addition, they are expected to be extremely radiation hard and very temperature insensitive. That is, they are expected to have radiation hardness characteristics similar to vacuum tubes, and both the high temperature and low temperature limits should be determined by the package. That is, there should be no practical intrinsic temperature or carrier freezeout problems for devices based on metals or composites. But the technology is difficult to implement at the present time because it is based on 300 to 500 angstrom radius field emitters which must be relatively uniform. There is also the need to understand the non-equilibrium transport physics in the near-surface regions of the field emitters.

Gray, Henry F.↗

High-dynamic-range MCP structures

We report on the development of a new high-dynamic-range two-stage Multi-Anode Microchannel Array (MAMA) imaging tube designed for improved high count rate performance at FUV and EUV wavelengths. The new two-stage MAMA tube employs two 25-mm-diameter format MCPs placed in tandem with a small gap between the plates. The front (input) MCP is designed to be a low-gain converter plate that supports an opaque photocathode and converts the detected photons to electrons, while the second (output) MCP is of higher conductivity and thus maintains the overall gain of the multiplier at high count rates. The second MCP is mounted in proximity focus with a (224 x 960)-pixel fine-fine coincidence MAMA array for high-spatial-resolution imaging studies. The applied voltage across each MCP can be controlled independently. We report on the gain and dynamic range performance characteristics of the two-stage MAMA tube in two different configurations: first, with the output MCP having moderate conductivity (about 100 MOhm); and second, with the output MCP having very high conductivity (about 2 MOhm). These results are compared and contrasted with those of the more conventional MAMA tube configuration which employs a single high-gain curved-channel MCP.

Slater, David C.↗

Application of a dedicated micro-processor for automatic data acquisition of load strain and acoustic-emission data

This paper describes an automatic system for acquisition, logging and analysis of stress, strain and acoustic emission data. The complete system is a combination of several standard items of equipment and a newly developed intelligent data logger which has the capability to send data directly to a large scale computer for reduction and plotting. The data logging and all interfacing with peripheral equipment are accomplished using digital electronics. The heart of the system is a four-bit microprocessor and digital cassette tape unit. The system, which is controlled by instructions from a cathode ray tube terminal, has the capability to transmit data from the cassette unit to a large computer via a time sharing option. Typical results are presented for acoustic emission count rate and total count curves superimposed on stress-strain diagrams for boron/epoxy advanced composites.

Wilson, G. H.↗

Numerical simulations of counterstreaming plasmas and their relevance to interhemispheric flows

The collisionless expansion of counterstreaming plasmas has been studied in order to elucidate the basic physical processes that may be operating during the initial refilling of depleted flux tubes after a magnetic storm. The numerical technique applied is briefly described, and simulation results are presented. The simulation geometry consisted of two high-density H(+)-O(+) electron plasmas separated by a low-density H(+)-electron plasma. The temporal evolution of the expanding plasmas and the electostatic potential in the region between the two sources is described. The main interacting streams are found to be stable with respect to both the ion acoustic and ion cyclotron modes and only the suprathermal forerunner ions are unstable with respect to the ion cyclotron mode. The results also suggest that a localized potential hill can form at the equator and that this potential hill can play an important role in the subsequent trapping and thermalization of the ion streams.

Singh, N.↗

Calculation of pressure-broadened linewidths for CO in Ar

Calculations of the pressure-broadening cross sections of CO in Ar have been made within the infinite-order sudden (IOS) and coupled states (CS) quantum scattering approximations. Two intermolecular potentials were used, a pairwise additive atom-atom potential which has been employed previously in semiclassical (modified Anderson theory) studies of this system and one calculated ab initio within an electron gas formalism. Predictions from the two potentials generally agree within about 25 percent and bracket experimental values (except for some recent high temperature data obtained in shock tube experiments). The CS approximation appears to be quite accurate although computationally expensive. The much cheaper IOS approximation is accurate for the J = 0-1 line but does not properly predict the dependence on line number. The quantum results are also compared with earlier semiclassical values.

Green, S.↗

Studies on counterstreaming plasma expansion

Recent studies on counterstreaming plasma expansions are summarized. The basic phenomenon of plasma expansion is reviewed, and results from one-dimensional simulations of counterstreaming plasma expansion are discussed. Results from simulations based on an electrostatic particle-in-cell code, in which the dynamics of both the electrons and ions are exactly followed, are discussed. The formation of electrostatic shocks is addressed. Finally, results are presented on the ionospheric plasma expansion along the geomagnetic flux tubes by solving the hydrodynamic equations.

Singh, N.↗

On the Use of 3dB Qualification Margin for Structural Parts on Expendable Launch Vehicles

The standard random vibration qualification test used for Expendable Launch Vehicle components is Maximum Predicted Environment (MPE) + 6dB for a duration of 4 times the service life of the part. This can be a severe qualification test for these fatigue-sensitive structures. This paper uses flight data from several launch vehicles to establish that reducing the qualification approach to MPE+3dB for the duration of the peak environment (1x life) is valid for fatigue-sensitive structural components. Items that can be classified as fatigue-sensitive are probes, ducts, tubing, bellows, hoses, and any non-functional structure. Non-functional structure may be flight critical or carry fluid, but it cannot include any moving parts or electronics. This reduced qualification approach does not include primary or secondary structure which would be exclusively designed by peak loads, either transient or quasi-static, that are so large and of so few cycles as to make fatigue a moot point.

Yunis, Isam↗

Vibrational relaxation in expanding N2 and air

New N2 vibrational temperature data, obtained in expanding N2 and air using the electron beam technique, are analyzed permitting the vibrational relaxation times to be determined as a function of temperature. In addition, the effects on N2 vibrational relaxation times of direct vibrational energy transfer between N2 and H2O, between N2 and O2, and between N2 and free electrons introduced from arc contaminants are analyzed. The vibrational relaxation times determined from the present measurements agree with those measured in the expanding flows of shock tunnels and impact tubes. These expanding data also agree with relaxation times observed in acoustical resonant cavities where alternating compressions and expansions take place. The relaxation times in expanding flows (vib-tran exchange process) are found to be approximately 50 times faster than those measured in the compressing flow of shock tubes (tran-vib exchange process). This evidence strongly supports the concept that one relaxation time distribution cannot be applied to both exchange processes.

Sebacher, D. I.↗

High resolution spectral analysis of the Jovian decametric radiation. II - The band-like emissions

Analysis of the bandlike Jovian decametric emission is presented. A model for the active region that accounts for the observed radiation characteristics is described using the measured parameters of the bandlike emission and a model of the Jovian magnetic field. The active region is characterized not only by the fact that an upward-flowing electron stream is caused to radiate in this region, but the stream itself is broken into radiating electron bunches within the active region. Observed undulations of the emission band on the time-frequency plane are interpreted as motions of the active region along a flux tube. The instantaneous location of the active region along the flux tube shows a dependence on the density of the stream entering the active region. The mechanism responsible for density modulation of the stream appears to be common to both the bandlike and simple-S-burst emission types.

Flagg, R. S.↗

The low-energy plasma in the Jovian magnetosphere

Burke and Franklin (1955) discovered radio emissions from Jupiter at 22.2 MHz. Subsequent observations established the strong control of the decametric emissions by the satellite Io. The Voyager encounters with Jupiter in 1979 have resulted in a dramatic increase in detailed knowledge of the plasma properties of the Jovian magnetosphere. The Io plasma torus is discussed, taking into account the Voyager plasma science experiment, positive-ion temperatures in the torus, electron distribution functions in the torus, elementary-charge concentrations in the torus, positive-ion composition in the torus, and plasma velocities in the torus. The Io flux tube is considered along with the middle magnetosphere and the outer magnetosphere. Attention is given to the sources of plasma, aspects of diffusive transport, questions of inertial loading, and the existence of nonazimuthal flow velocities in the middle magnetosphere.

Belcher, J. W.↗

Apparatus analysis and preliminary design of low gravity porous solids experiment for STS Orbiter mid-deck

The apparatus analysis laboratory equipment design and fabrication and the preliminary design of the Combustion of Porous Solids Experiment for operation in the mid-deck area of the Shuttle are described. The apparatus analysis indicated that the mid-deck region of the STS was a feasible region of the Shuttle for operation. A sixteen tube concept was developed with tubes of 75 cm length and up to 5.6 cm accommodated. The experiment is viewed by IR sensors and a 16 mm camera. Laboratory equipment was designed and fabricated to test the parible injection, mixing and venting concepts. This equipment was delivered to NASA/LeRC. A preliminary design was made for the experiment based upon the apparatus analysis. The design incorporated results from the Phase ""O'' Safety Review. This design utilizes a closed tube concept in which the particles are stored, injected and burned with no coupling to the Shuttle environment. Drawings of the major components and an assembly are given. The electronics are described for the experiment. An equipment list is presented and an experiment weight estimate is determined. The mission operation requirements are outlined.

Fleeter, R. D.↗

Development of a radiation-hard photomultiplier tube

In a radiation-hard photomultiplier tube (PMT) such as has been developed for stabilization of the Galileo spacecraft as it goes through the Jovian high energy radiation belts, the primary effects of high energy electron and proton radiation that must be resisted are the production of fluorescence and Cerenkov emission. The present PMT envelope is ceramic rather than glass, and employs a special, electron-focusing design which will collect, accelerate and amplify electrons only from desired photocathode areas. Tests in a Co-60 radiation facility have shown that the radiation-hard PMT produces less than 2.5 percent of the radiation noise of a standard PMT.

Birnbaum, M. M.↗

Gravity Effects in Carbon Nanotube Growth by Thermal Chemical Vapor Deposition

Carbon nanotubes are synthesized using thermal chemical vapor deposition. The sizes of these carbon nanotubes (CNT) are quite uniform and the length of the tube is up to several tens of micrometers. With the substrate surface normal either along or against the gravity vector, different growth orientations of CNT are observed by scanning electron microscopy although the Raman spectra are similar for samples synthesized at different locations. These results suggest the gravitation effects in the growth of long and small diameter CNT.

Zhu, S.↗

Characterization Testing of Lockheed Martin Standard Micro Pulse Tube Cryocooler

This paper describes the thermal performance, exported vibration, and magnetics testing and results of a Lockheed Martin standard micro pulse tube cryocooler. The thermal performance of the microcooler was measured in vacuum for heat reject temperatures between 150 and 300 K. The cooler was driven with Thales XPCDE4865 drive electronics for input powers ranging from 4 to 20 W and drive frequency between 84 and 98 Hz. The optimal drive frequency was dependent on both input power and heat reject temperature. In addition, the exported forces and torques of the cooler were measured with the cooler driven by Thales CDE7232 drive electronics for input powers ranging from 4 to 20 W and drive frequency between 88 and 96 Hz. The exported forces were dependent on both input power and drive frequency. Moreover, the automatic vibration reduction function of the drive electronics was able to decrease the force in the compressor axis to below 10 mN 0-peak. Finally, the DC and AC magnetic fields around the cooler were measured at various locations.

McKinley, I. M.↗