Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Theranostic Radiopnictogens: 71 As, 72 As, and 119 Sb (Final Technical Report)

This project has developed new methods for the cyclotron production of medically relevant radionuclides 71 As and 119 Sb. Arsenic and antimony are chemically homologous elements (group 5A, also known as the pnictogens) that have radionuclides that are of considerable interest within nuclear medicine. Such radiopnictogens include the potentially therapeutic radionuclides 119 Sb (t 1/2 = 38 h) that decays with the emission of 24.5 low energy, high potency electrons per decay with little concomitant photon radiation and 77 As (t 1/2 = 39 h) that decays with average beta energy of 230 keV and diagnostic nuclides 71 As (t 1/2 = 65 h, 28% β+) and 72 As (t 1/2 = 26 h, 80% β+) for positron emission tomography (PET). This work has had major success developing new methods for the cyclotron production and radiochemical isolation of 71 As, supporting parallel developments for 119 Sb, and assessing the chemical similarities between these two homologous radionuclides. This project brought into collaboration two universities with complimentary skill sets, proficiencies, expertise, and facilities: the University of Wisconsin (UWisc) and the University of Missouri (Mizzou). Professors Ellison and Engle have experience in the small cyclotron production and radiochemical isolation of radionuclides, including 72 As and 119 Sb. Their recently developed metallurgic methods for fabricating cyclotron targets have great potential to expand and allow for the biomedical cyclotron production of long- lived, lower positron energy 71 As. Professors Hennkens and Jurisson have significant experience in the reactor production, radiochemical isolation, and biological functionalization of radioarsenic. Recent development of trithiol-based chelator molecules for functionalizing radioarsenic provide a platform for the investigation of the fundamental challenges of the promising low-energy-electron emitter, 119 Sb. Through their positions within their respective University’s graduate schools, the PIs and Co-Is effectively trained of graduate students and postdoctoral researchers in nuclear and radiochemistry, sub-specialties specifically identified in the Department of Energy (DOE) Office of Science Isotope Program long-range plan. Annual laboratory research visits for students between UWisc and Mizzou provided essential broad-field experience and scientific networking that is critical for maintaining their path along the training pipeline to productive careers in isotope production. This research collaboration has provided significant benefits to the DOE University Isotope Network and radionuclide-using researchers around the country.

07 ISOTOPE AND RADIATION SOURCES↗

Metalorganic chemical vapor deposition of ZnGeN 2 films on GaN: effects of cation stoichiometry on surface morphology and crystallinity

Novel optoelectronic device designs based on the heterostructures of III-N and II-IV-N 2 are promising to advance device performance significantly. For example, by utilizing InGaN-ZnGeN 2 quantum well (QW) structures instead of pure InGaN, the band structure engineering in the QW active region can lead to improved electron-hole wavefunction overlap, and thus enhance the radiative efficiency for photon generation. These novel heterostructures have great potential to address the current challenge of low quantum efficiency in InGaN QW based light emitting diodes emitting in green and beyond. The materials development of ZnGeN 2 is still at an early stage as compared to the much matured GaN material system. In an ideal octet rule preserving ordered structure of ZnGeN 2 , every N atom is coordinated by exactly two Zn and two Ge atoms. However, local violation of octet rule can be caused by non-ideal coordination of N by the cations. The disordered structure is thermodynamically less favorable but can still be achieved, for example, in kinetics-limited growth regime. The ordered ZnGeN 2 has a bandgap very close to that of GaN (~3.4 eV) and a lattice mismatch of <0.1% with GaN. Interestingly, the valence band of ZnGeN 2 has been predicted to be ~1 eV above that of GaN, which has inspired novel designs for high efficiency light emitters. In this work, we investigated the metalorganic chemical vapor deposition (MOCVD) of ZnGeN 2 films on GaN/c-sapphire templates. Diethylzinc (DEZn), germane (GeH4) and ammonia were used as the precursors for Zn, Ge and N, respectively. A systematic study was conducted to investigate the cation stoichiometry as a function of growth temperature (TG), total reactor pressure (P) and DEZn/GeH 4 molar flow rate ratio (RII/IV). Under the investigated growth window, the Zn/(Zn+Ge) composition in the films, determined from energy dispersive X-ray spectroscopy, decreased monotonically with increase in TG but increased with increase in P and RII/IV. Atom probe tomography data did not indicate the presence of any secondary phases such as Zn 3 N 2 or Ge 3 N 4 . The surface morphology and crystallinity of the grown films had strong correlation with the Zn/(Zn+Ge) composition. The scanning electron microscopy images showed that the near-stoichiometric films have planar surfaces whereas Zn-rich films had crystallites on their surface and the Zn-poor films had faceted surface. Scanning transmission electron microscopy (STEM) imaging revealed that the Zn-rich and Zn-poor films have columnar and filament-like morphology, respectively, whereas the near-stoichiometric films have continuous film-like cross-sectional morphology. TEM nano-diffraction patterns as well as X-ray diffraction 2θ-ω scan profiles indicate that the near stoichiometric films are single crystalline. Nano-diffraction pattern of the stoichiometric films resembled that of a disordered ZnGeN 2 structure. Room temperature Raman spectra of near-stoichiometric films showed only the phonon density of states like features of a cation disordered ZnGeN 2 . Cathodoluminescence and photoluminescence spectra measured at different temperatures had similar features with peak emission wavelength at ~ 2 eV. In conclusion, the stoichiometry of ZnGeN 2 films can be widely tuned by tuning the MOCVD growth parameters. The surface morphology and the crystallinity of the films were found to have strong correlation with the Zn/(Zn+Ge) composition. The stoichiometric ZnGeN 2 films grown on GaN were demonstrated with uniform surface morphology and high crystalline quality. The results from this work will provide pathway to implement ZnGeN 2 in device structures.

Karim, Md Rezaul↗

Microstructural features and deuterium diffusion in lithium penta-aluminate pellets under He + and D + ion irradiation

Lithium (Li) penta-aluminate (LiAl 5 O 8 ) is investigated as a potential tritium (T) breeding material, with a focus on microstructural response to ion irradiation and deuterium (D) diffusion behavior. Under high-fluence ion irradiation (2 x 10 17 (He + +D + )/cm 2 ) at 773 K, LiAl 5 O 8 exhibits significant disorder on the Li sublattice, as revealed by atomic-resolution scanning transmission electron microscopy, while the Al and O sublattices remain stable, demonstrating strong resistance to structural amorphization. Irradiation induces the formation of platelet-shaped antiphase boundaries (APBs), which may serve as effective D trapping sites. Atom probe tomography suggests the presence of 6 LiD clusters in the mass spectra, though definite conclusions regarding APB composition are hindered by signal overlap and limited data statistics. Time-of-flight secondary ion mass spectrometry reveals that D retention approaches to saturation at 3 x 10 17 (He + +D + )/cm 2 . Isothermal and isochronal annealing studies determine an average diffusivity of 1.6 x 10 -13 at 773 K and an effective activation energy of 0.8 ± 0.1 eV for D migration. Compared to γ-LiAlO 2 , LiAl 5 O 8 demonstrates superior irradiation resistance, minimal Li loss, and enhanced D retention, underscoring its potential as a durable breeder material for T production. In conclusion, these findings provide key insights into the microstructural evolution, defect dynamics, and D retention mechanisms in LiAl 5 O 8 under reactor-relevant conditions.

42 ENGINEERING↗

Characterization of Incremental Markings in the Sagittal Otolith of the Pacific Sardine ( Sardinops sagax ) Using Different Imaging Modalities

Teleost fish possess calcium carbonate otoliths located in separate chambers (utriculus, sacculus, and lagena) of their membranous labyrinth. This study analyzed the surface topography of the sagittal otolith of the Pacific sardine (Sardinops sagax) and the daily and annual increments in these otoliths. The otolith surface, characterized by laser scanning confocal microscopy for the first time, consisted of a system of prominent ridges and valleys (grooves), but it is unclear whether these structures are functional or represent time-resolving markings reflecting growth periodicity. Within the first-year volume, daily increments, each consisting of an incremental (more mineralized) and a discontinuous (less mineralized) zone, were resolved by optical microscopy and backscattered electron (BSE) imaging in the scanning electron microscope (SEM). Daily growth increments could, however, not be resolved in volumes formed after the first year, presumably because otolith growth markedly slows down and spacing of incremental markings narrows in older fish. Throughout otolith growth, the crystalline network continues across the discontinuous zones. Fluorochrome labeling provides additional information on growth after the first year. Compared with optical and BSE imaging, synchrotron microComputed Tomography of intact otoliths (with 0.69 µm volume elements) was less able to resolve daily increments; X-ray phase contrast reconstructions provided more detail than reconstructions with absorption contrast. Future research directions are proposed.

59 BASIC BIOLOGICAL SCIENCES↗

Effects of cation stoichiometry on surface morphology and crystallinity of ZnGeN 2 films grown on GaN by metalorganic chemical vapor deposition

ZnGeN 2 films were grown on GaN-on-sapphire templates via metalorganic chemical vapor deposition. Energy dispersive X-ray spectroscopy was used to estimate the Zn/(Zn+Ge) composition ratio in the films. This ratio decreased with increase in growth temperature but increased with increase in total reactor pressure or Zn/Ge precursor flow rate ratio. Systematic mapping of these key growth parameters has allowed us to identify the growth window to achieve ZnGeN 2 with stoichiometric cation composition. Compositional and statistical analyses performed on data acquired from atom probe tomography provided insight into the local compositional homogeneity. The cations Zn and Ge did not demonstrate segregation or clustering at the sub-nanometer level. Based on X-ray diffraction 2θ-ω scan profiles and transmission electron microscope nano-diffraction patterns, the films with near-stoichiometric cation ratios were single crystalline with planar surfaces, whereas zinc-rich or zinc-poor films were polycrystalline with nonplanar surfaces. The growth direction of the single crystalline ZnGeN 2 films on GaN templates was along the c-axis. Room temperature Raman spectra showed features associated with the phonon density of states, indicating the presence of cation disorder in the lattice. A cathodoluminescence peak associated with transitions involving deep level defects was observed around 640 nm. The intensity of this peak increased by almost 2.5 times as the temperature was reduced to 77 K from room temperature. A similar peak was observed in photoluminescence spectra collected at 80 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Initial results from electron microscopy from AGR 5/6/7 Capsule 1 fuel and

Initial results from electron microscopy from AGR 5/6/7 Capsule 1 fuel and applications of other microanalysis techniques to irradiated TRISO fuel. Includes detail on characterization of particles from AGR 5/6/7 Capsule 1, which include background and motivation, x-ray computed tomography on four particles from compact 1-7-9, SEM/EDS of particles from compacts 1-7-9 and 1-7-4, and Summary. Local thermal conductivity measurement on AGR-2 particles also discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Lpp positions peptidoglycan at the AcrA-TolC interface in the AcrAB-TolC multidrug efflux pump

The multidrug efflux pumps of Gram-negative bacteria are a class of complexes that span the periplasm, coupling both the inner and outer membranes to expel toxic molecules. The best-characterized example of these tripartite pumps is the AcrAB-TolC complex of Escherichia coli. However, how the complex interacts with the peptidoglycan (PG) cell wall, which is anchored to the outer membrane (OM) by Braun’s lipoprotein (Lpp), is still largely unknown. In this work, we present molecular dynamics simulations of a complete, atomistic model of the AcrAB-TolC complex with the inner membrane, OM, and PG layers all present. We find that the PG localizes to the junction of AcrA and TolC, in agreement with recent cryo-tomography data. Free-energy calculations reveal that the positioning of PG is determined by the length and conformation of multiple Lpp copies anchoring it to the OM. The distance between the PG and OM measured in cryo-electron microscopy images of wild-type E. coli also agrees with the simulation-derived spacing. Finally, sequence analysis of AcrA suggests a conserved role for interactions with PG in the assembly and stabilization of efflux pumps, one that may extend to other trans-envelope complexes as well.

59 BASIC BIOLOGICAL SCIENCES↗

An automated fast neutron computed tomography instrument with on-line focusing for non-destructive evaluation

A fast neutron tomography imaging instrument has been designed, built, and tested at The Ohio State University 500 kW Research Reactor on a fast neutron beamline with a peak neutron flux ≈5.4 × 107 n·cm−2·s−1 at 1.6 MeV median neutron energy. The instrument and beamline are also configurable for thermal neutron imaging. The imaging apparatus is composed of a lens coupled, water-cooled Electron Multiplying Charge Coupled Device camera, a front-surface mirror, and a high light yield plastic Polyvinyl toluene scintillator. The instrument sits on a mobile cart. A total of 5 motion-control stages are built into the system for XYZ and rotational degrees of freedom for sample positioning; the fifth stage fine tunes the focal distance between the camera and the scintillator to achieve on-line focusing. A Python code with a user-friendly graphical user interface controls the fully automated image acquisition, not requiring user interaction, yet facilitating tracking of the image acquisition. A complete fast neutron computed tomography dataset with 360 projections requires less than 3 h, with 30 s per projection. On-line focusing is accomplished with a commercial, off-the-shelf, dielectrically actuated liquid lens. Finally, tomographic reconstructions are visualized using the Livermore Tomography Tools software package. The effective pixel size (width and height) is ≈0.1058 mm, yielding a minimum voxel size of 0.1058 × 0.1058 × 0.1058 mm3, and produces a spatial resolution of 231 μm when calculated from knife-edge measurements.

Bisbee, M. G. (ORCID:0000000313466697)↗

Nondestructive In Operando Imaging of Thin Film Composite Membrane Compaction Enhanced by AI-Based Segmentation

Reverse osmosis (RO) membranes are essential for desalination and water reuse, yet their permeability declines in high-pressure applications due to membrane compaction. This study investigates the structural and functional responses of commercial brackish, seawater, and high-pressure RO membranes at applied pressures up to 120 bar using a multiscale, nondestructive in operando scanning electron microscopy (iSEM) imaging platform. The iSEM technique reveals progressive densification across the composite membrane structure, which correlates with observed declines in water and solute permeance. To quantify these structural changes with greater fidelity, we combined X-ray computed tomography with AI-based segmentation enabling precise analysis of pore size distribution and thickness of the polysulfone support layer. Compared to traditional thresholding, AI segmentation accurately delineates material phases and void spaces, enhancing the reproducibility and resolution of morphological assessments. The results demonstrate that compaction-induced reductions in porosity and thickness strongly impact membrane transport properties. These findings provide mechanistic insights into the compaction behavior of RO membranes and underscore the potential for advanced imaging and AI-driven data analysis to guide the design of next-generation membranes with improved mechanical resilience and operational longevity.

13 HYDRO ENERGY↗

Three-dimensional imaging of grain boundaries via quantitative fluorescence X-ray tomography analysis

Abstract Three-dimensional visualization of material composition within multiple grains and across complex networks of grain boundaries at nanoscales can provide new insight into the structure evolution and emerging functional properties of the material for diverse applications. Here, using nanoscale scanning X-ray fluorescence tomography, coupled with an advanced self-absorption correction algorithm developed in this work, we analyze the three-dimensional gain distributions and compositions in a Ce 0.8 Gd 0.2 O 2-δ -CoFe 2 O 4 mixed ionic-electronic conductor system with high accuracy and statistical significance. Our systematic investigation reveals an additional emergent phase and uncovers highly intriguing composition stability ranges for the multiple material phases within this system. The presented visualization of composition variations across complex interfaces, supported by our quantitative composition analysis, discloses mechanistic pathways of the diverse phase transformations occurring in the material synthesis, providing insights for the optimization of transport properties in the mixed ionic-electronic conductor system.

36 MATERIALS SCIENCE↗

Photovoltaic Cable Connectors: A Comparative Assessment of the Present State of the Industry [Slides]

The consequences of failure for balance of systems (BoS) components (such as PV cable connectors) include offline module string(s); low system voltage; arc, ground, insulation, and over-temperature faults; triggered fuse(s); system shutdown; and fire. The degradation modes for connectors are studied here through an industry survey and its subsequent examination, which are compared to field-degraded specimens. 117 specimens were obtained from a variety of locations and climates or accelerated tests. A failure analysis for connectors from PV installations was developed (and applied to 54 specimens) including nondestructive examinations (photography, a custom resistance-current scan, and X-ray computed tomography) and destructive examinations (featuring milling of the external plastic, extraction of the internal convolute spring, and potting and polishing in cross-section). Surface and through-thickness composition of the metal pins and springs was quantified using scanning electron microscopy with energy-dispersive X-ray spectroscopy. Fourier-transform infrared spectroscopy was used to verify the base polymer materials and compare the chemical structure of the connector body, bushing, end nut, and o-ring. Thermogravimetric analysis and differential scanning calorimetry were used to further verify the degradation of the same polymeric components. Updated from 2023 NIST/UL Workshop on Photovoltaic Materials Durability (website: https://events.ul.com/WPMogn?rt=aAuoWsl4E0KaORLCMeOgfA) and 2024 PVRW workshop (https://pvrw.nrel.gov/past-proceedings).

14 SOLAR ENERGY↗

A study of the effects of prolonged simulated microgravity on the musculature of the lower extremities in man - An introduction

The experimental approach and the protocol are described for a study designed to investigate the effect of prolonged microgravity (simulated by a continuous exposure of subjects to 30-d-long 6-deg headdown tilt) on the musculature of the lower extremities in humans. The objectives of this study are as follows: (1) to determine changes in the functional characteristics of knee joint flexor and extensor muscle group; (2) to examine changes in the histochemical, biochemical, electron microscopic, and computed tomographic characteristics of skeletal muscle; (3) to determine if functional characteristics of skeletal muscle would be normalized four weeks after the bedrest; and (4) to compare these results to those of spaceflight. Percutaneous muscle biopsy, computed tomography, anthropometry, and in vivo muscle strength measurements are to be used to assess mechanical, structural, and metabolic characteristics of skeletal muscle.

Buchanan, Paul↗

Analysis of rocket beacon transmissions for computerized reconstruction of ionospheric densities

Three methods are described to obtain ionospheric electron densities from transionospheric, rocket-beacon TEC data. First, when the line-of-sight from a ground receiver to the rocket beacon is tangent to the flight trajectory, the electron concentration can be obtained by differentiating the TEC with respect to the distance to the rocket. A similar method may be used to obtain the electron-density profile if the layer is horizontally stratified. Second, TEC data obtained during chemical release experiments may be interpreted with the aid of physical models of the disturbed ionosphere to yield spatial maps of the modified regions. Third, computerized tomography (CT) can be used to analyze TEC data obtained along a chain of ground-based receivers aligned along the plane of the rocket trajectory. CT analysis of TEC data is used to reconstruct a 2D image of a simulated equatorial plume. TEC data is computed for a linear chain of nine receivers with adjacent spacings of either 100 or 200 km. The simulation data are analyzed to provide an F region reconstruction on a grid with 15 x 15 km pixels. Ionospheric rocket tomography may also be applied to rocket-assisted measurements of amplitude and phase scintillations and airglow intensities.

Bernhardt, P. A.↗

Three-dimensional reconstruction of coronal mass ejections

Computer assisted tomography (CAT) techniques are used to reconstruct the three dimensional shape of coronal mass ejections in the interplanetary medium. Both the Helios 2 spacecraft zodiacal-light photometers and the Solwind coronograph measure changes in Thomson scattering of sunlight from electrons. The technique from near-perpendicular Solwind and Helios views are applied to determine the density of a mass ejection which left the solar surface on 24 May 1979. The coronograph and the Helios perspective views are not simultaneous; the Solwind observations extend outward to sky plane distances of only 10 of the solar radius, whereas the Helios 16 photometer observes to as close as 17 of the solar radius from the sun. The solution is obtained by assuming outward radial expansion and that the coronal mass ejections (CME's) have the same speed everywhere at the same height. The analyses show that CME's are extensive three dimensional structures (the CME of 24 May appears approximately shell) like in three dimensions.

Jackson, Bernard V.↗

Magnetospheric Constellation and Tomography Mission Concept

We describe the basic principles, instrumentation, and feasibility of a multi-satellite mission that combines in situ observations of plasma and electromagnetic fields with radio tomography imaging. We show that a 16-satellite radio tomography experiment can produce two-dimensional images of plasma density in the earth's magnetosphere at sufficient spatial (1/2 R(sub E)) and temporal (approximately 10s) resolution to address key problems of magnetospheric physics. The same mission can incorporate electron and ion analyzers, magnetometers, and electric field instruments on the same spacecraft. We suggest that the large-scale images are more valuable when combined with in situ observations, supporting an unambiguous interpretation of the in situ data and an investigation of the interdependence of small- and large-scale plasma processes.

Ergun, R. E.↗

Microgravity Electrical Capacitance Tomography Data Set

Propellants mass gauging technologies designed to work in an accelerated environment, where the propellant remains settled at one end of the propellant tank, do not work well in a microgravity environment because the propellant is not necessarily settled. While some microgravity mass gauging technologies exist at various TRLs, most of them have major disadvantages. Improvements in microgravity propellant mass gauging will result in improvements to many areas of propellant management, which influences performance and mission assurance. Electrical Capacitance Tomography (ECT) is a sensing technology that has been used in the oil/gas industry for decades to measure multi-phase flow rate in pipes. ECT, when installed in a tank, is able to reconstruct the liquid distribution inside of the tank, which can then be integrated to obtain mass. ECT mass gauging recently achieved high accuracy in laboratory testing on the ground, and while ECT mass gauging will theoretically work during all phases of flight, it had not yet been tested in microgravity. The NASA KSC Launch Services Program, with support from the Flight Opportunities Program, successfully flew an ECT tank liquid mass gauging system experiment on a Zero-G parabolic flight aircraft. The experiment hardware was rented from a company; NASA LSP did no technology development work for this project. This STRIVES entry is for the entire raw data set, which consists of approximately 25GB of csv files of capacitance and motion data from the ground and flight tests of the experiment. The data set will be available on the NASA LSP Electronic Slosh Data Catalog (ESDC), and the public may request the data set from the authors (POC: Jed Storey, jedediah.m.nasa.gov).

mass gauging↗

Heterogeneous fatigue damage in a nickel-based single-crystal superalloy unraveled using correlative 3D X-ray technology

Nickel-based single-crystal (Ni-SX) superalloys under cyclic stress are susceptible to cracking at stress-concentration sites, eventually leading to low-cycle fatigue (LCF) failure. LCF cracks typically originate from intrinsic defects (e.g., voids and carbides) within solidified dendrites. However, systematic quantitative experimental analyses of defect-mediated local damage remain limited. To thoroughly understand the microscopic origins and evolution of LCF damage, correlated 3D mapping of dendrites across various regions is essential. Here, in this study, macroscale micro-computed tomography (μ-CT) was initially used to capture internal interdendritic secondary cracks within bulk DD413 superalloy after LCF testing at 760 °C. Subsequently, a multimodal methodology combining synchrotron 3D microdiffraction (3D-μXRD), high-resolution μ-CT, and electron microscopy was established. This approach allowed precise localization of internal damage zones near interdendritic secondary cracks and detailed mapping of the 3D correlated distributions of dendrites, defects, and residual stress/strain fields within these zones at submicron spatial resolution. Finally, the same approach was applied to specimens subjected to interrupted loading at approximately 40 % of the fatigue life to uncover the early damage states of dendrites. The dendrite cores (DCs) and interdendritic regions (IDs) exhibit microscale heterogeneous mechanical responses: nearly defect-free DCs accumulate local irreversible slip along specific slip systems to generate slip bands, while the IDs containing various defects accommodate local microplasticity through the activation of multiple slip systems around these defects. The local tensile stress near defects in the IDs exceeds that in the DC slip band regions by more than threefold, leading to the generation of local damage zones within the IDs. Chain-like defect distributions facilitate the interconnection of these local zones into a continuous damage region, further elevating the overall tensile stress in the IDs. Additionally, geometrically necessary dislocations alone are insufficient as indicators of LCF damage; both the internal stress state and its magnitude must be considered. These experimental results provide critical data and insights for the development of multi-physics fatigue models.

Localized deformation↗

Aggregated nanoparticles: Sample preparation and analysis by atom probe tomography

Atom probe tomography (APT) allows measurement of the three-dimensional structure and composition of materials, but specific sample preparation procedures are required for challenging materials such as aggregates of nanoparticles. Indeed, the presence of porosity within the specimen affects both the stability of the sample and the accuracy of the data. In this work, aggregates of nanoparticles were transferred onto a micromanipulator tip and embedded via electron-beam-assisted deposition of Pt. Successive FIB-millings and Pt-depositions are needed to create suitable APT tips. The 3D reconstruction reveals the presence of 15–20 nm nanoparticles, and massspectral analysis shows the absence of trace elements within the catalyst, thus serving as quality control for the synthesis of nanoparticles with specific compositions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗