Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric currents”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

TASTI-GRID: Overview of the State of Oregon’s Resilience and Reliability [Slides]

This report is intended to help your state identify the most effective investments to improve grid resilience and reliability, based on analysis of outage data, weather events, and the current state of the electric grid. The information presented is derived from the best available data. The discussions and recommendations included provide context and valuable insights into potential high returns on investment (ROI). Specifically, the report offers an overview of electric grid resilience in Oregon, covering outage information, reasons for outages, calculated "resilience scores" across the state, and recommendations for both immediate and long-term investments in grid infrastructure. The document provides a concise overview of the analytical capabilities of the TASTI-GRID team. By utilizing additional data and resources, it synthesizes insights from the platform to present a distinct perspective on investing in grid resilience throughout Oregon. This document is not intended to influence or direct state-level decisions related to investments in grid resilience and reliability. TASTI-GRID should not be used for real-time monitoring, supporting the ESF #12 emergency response functions, or predicting the restoration times for outages.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluations of Connectors, Inlets, and Adapters on Side-Load and Withstand Force

This report examines the mechanical forces that direct current fast charging (DCFC) electric vehicle supply equipment (EVSE) connectors and electric vehicle (EV) inlet ports experience during normal usage. As we witness the fast and growing variety of EVs, charge port locations, and bigger and more powerful EVSE configurations including the SAE J3400 North American Charging Standard (NACS), which has increased the use of adapters with J3400 and J1772 compatibility. These new conditions contribute to increased mechanical forces due to their size, weight and lever arm effect, which creates the need to study and compare these forces to the limits on UL2251 and IEC 62196-1 standards. This report focuses solely on high power DC charging EVSE connectors, EV inlets and adapters for the specific compatibility cases on J3400 with J1772. We first describe the details of the 100N and the 750N side-load evaluations as described in the standards, then present the data obtained by replicating these tests to finally go into more detail on the findings and our recommendations.

100N↗

Systemic Drivers of Electric-Grid-Caused Catastrophic Wildfires: Implications for Resilience in the United States

Wildfires are projected to increase in severity and frequency due to climate change, and the electric grid is both a cause of wildfires and is vulnerable to wildfires. Equipment from the electric grid accounts for 10% of fires burned in California and 3% of fires nationally. Recent catastrophic wildfires, such as the Lahaina Fire, Camp Fire, Marshall Fire, and Smokehouse Creek fires, were all started by electrical equipment and show how devastating these events can be because they threaten lives and structures. Vegetation structure, weather and winds, climate and vegetation response, land use, and human activities all impact the likelihood of severe wildfires. We explore the relationship between the built environment, electric grid infrastructure specifically, and its role in causing catastrophic wildfires to find lessons learned for increasing resilience. Electric grid utility companies currently employ multiple methods to mitigate fire, including (1) early detection, (2) grid hardening, (3) vegetation management, and (4) pre-emptive shutoffs. Utility companies need to consider the conditions for wildfire and the impact that each mitigation strategy has on drivers of wildfire behavior, as a single solution will not be adequate. Utility companies need to work with stakeholders to develop a holistic strategy to reduce ignition likelihood and spread likelihood to reduce catastrophic wildfires and improve resiliency.

Eagleston, Holly (ORCID:0000000178175116)↗

Second-order microscopic nonlinear susceptibility in a centrosymmetric material: application to imaging valence electron motion

We report measurements of phase-matched nonlinear x-ray and optical sum-frequency generation from single-crystal silicon using sub-resonant 0.95 eV laser pulses and 9.5 keV hard x-ray pulses from the LCLS free-electron laser. The sum-frequency signal appears as energy and momentum sidebands to the elastic Bragg peak. It is proportional to the magnitude squared of the relevant temporal and spatial Fourier components of the optically induced microscopic charges/currents. We measure the first- and second-order sideband to the 220 Bragg peak and find that the efficiency is maximized when the applied field is along the reciprocal lattice vector. For an optical intensity of $\sim10^{12} \text{W}/\text{cm}^2$, we measure peak efficiencies of $3\times 10^{-7}$ and $3\times 10^{-10}$ for the first and second-order sideband respectively (relative to the elastic Bragg peak). The first-order sideband is consistent with induced microscopic currents along the applied electric field (consistent with an isotropic response). The second-order sideband depends nontrivially on the optical field orientation and is consistent with an anisotropic response originating from induced charges along the bonds with C$_{3v}$ site symmetry. The results agree well with first-principles Bloch-Floquet calculations.

FOS: Physical sciences↗

The Evolving Nature of Grid Energy

Current trends in the electricity sector, including more variable renewable energy, electrification of transportation and other end-uses, and city and state-level clean electricity goals, impact our expectations for grid costs and emission rates out into the future. This talk provides an overview of where the grid is and where it is heading, and introduces new data sets under development at NREL that are aimed at enabling conversation between grid and built-environment planning and design.

24 POWER TRANSMISSION AND DISTRIBUTION↗

System and method for using ultramicroporous carbon for the selective removal of nitrate with capacitive deionization

The present disclosure relates to a flow through electrode, capacitive deionization (FTE-CDI) system which is able to adsorb nitrates from water being treated using the system. The system makes use of a pair of electrodes arranged generally parallel to one another, with a water permeable dielectric sandwiched between the electrodes. The electrodes receive a direct current voltage from an electrical circuit. At least one of the electrodes is formed from a carbon material having a hierarchical pore size distribution which includes a first plurality of pores having a width of no more than about 1 nm, and a second plurality of micro-sized pores. The micron-sized pores enable a flow of water to be pushed through the electrodes while the first plurality of pores form adsorption sites for nitrate molecules carried in the water flowing through the electrodes.

Campbell, Patrick↗

Electrical Analysis of Pulsed Laser Annealed Poly-Si:Ga/SiOx Passivating Contacts

High-efficiency single crystalline silicon (c-Si) solar cells require precise control of dopant diffusion profiles and highly active doping concentrations through thermal annealing. Conventional furnace annealing has been successfully employed for dopant diffusion in aluminum back-surface field (Al-BSF), passivated emitter and rear contact (PERC), and Topcon cells. However, furnace annealing limits some next-generation polycrystalline silicon (poly-Si) on SiOx passivating contacts. This limitation largely affects p-type passivating contacts by not being able to: 1) control the dopant diffusion accurately to prevent B segregation at the SiOx and c-Si interface; and 2) provide highly activated doping concentrations for low contact resistivity. In this contribution, we use a nanosecond excimer laser to examine the passivation quality and electrical performance of both B- and Ga-doped poly-Si/SiOx passivating contacts. The core of this method is to take advantage of the nonequilibrium nature of the anneal through rapid melting and recrystallizing the poly-Si in a short timescale and to achieve doping concentrations above the solid solubility limit. Simulations were performed on polished surfaces to visualize the doping diffusion profiles under different laser conditions, and secondary ion mass spectrometry (SIMS) was used to verify the experimental diffusion profiles post pulsed laser melting (PLM). The results show the dopant diffusion profiles can be tuned precisely through PLM. The electrical analysis using VdP-Hall measurements reveals that the active doping concentration reached 10^21 cm-3 for B and ~2×10^21 cm-3 for Ga in poly-Si, far exceeding their solid solubility limit in Si, with a nearly 100% dopant activation achieved for B, and 20% for Ga. This highly activated dopant profile results in a low contact resistivity of <15 mO·cm^2 for B-doped contacts and <40 mO·cm^2 for Ga-doped contacts. We demonstrate that the passivation quality of the laser annealed contacts shows a linear dependency with the laser energy density and the number of pulses. PLM was also performed on random pyramid textured samples, and we found that preferential melting exists for the tips of pyramids, which can be pursued further for selective pinhole opening. Additionally, we perform thermal stability tests of these hyperdoped passivating contacts and show that under certain laser conditions, the B-doped samples exhibit good thermal stability with near full activation for temperatures up to 800°C. Lastly, we transfer this technique to a larger area by overlapping laser spots and show uniform passivation quality and electrical performance. We are currently implementing this PLM annealed p-type passivating contacts into double-side back-junction poly-Si/SiOx passivating contact devices. Our results show that PLM can not only enable the next generation of high-efficiency c-Si photovoltaics technology but can also benefit the c-Si integrated circuit industry through hyperdoping other semiconductors with atoms that may otherwise have a low solubility.

doping diffusion profile↗

Hourly Load Profile Dataset for Electric Airport Ground Support Equipment in the United States

Currently, there are limited data on the magnitude and timing of electricity demand from electric ground support equipment (eGSE) across U.S. airports. To address this gap, this study presents a modeling approach for estimating hourly annual electricity demand from eGSE at the 50 largest U.S. commercial airports. These datasets, accessible at data.nrel.gov/submissions/279, provide critical insights into the potential grid impacts and electricity demand associated with eGSE adoption.

33 ADVANCED PROPULSION SYSTEMS↗

Simultaneous Energy Generation and Flow Enhancement (Electroslippage Effect) in Polyelectrolyte Brush Functionalized Nanochannels

Energy generation through nanofluidics is a topic of great nanotechnological relevance. In this work, we conduct all-atom molecular dynamics (MD) simulations of the transport of water and ions in a pressure-driven flow in nanochannels grafted with charged polyelectrolyte (PE) brushes and discover the possibility of simultaneous electrokinetic energy generation and flow enhancement (henceforth denoted as the electroslippage effect). Such PE-brush-functionalized nanochannels have been recently shown to demonstrate an overscreening (OS) effect (characterized by the presence of a greater number of screening counterions within the PE brush layer than needed to screen the PE brush charges), a consequent presence of excess coions within the PE brush-free bulk, and a coion-driven electroosmotic (EOS) transport in the presence of small to moderate applied axial electric fields. Here, however, we find that the streaming current, which represents the current generated by the flow-driven downstream advection of the charge imbalance present within the electric double layer (EDL) that screen the PE brush charges, is governed by the migration of the counterions. This stems from the fact that the highest contribution to the overall streaming current arises from the region near the PE brush-water interface (where there is an excess of counterions), while the brush-free bulk yields a hitherto unreported, but small, coion-dictated streaming current. This downstream advection of the charge imbalance (and the resultant counterion-driven streaming current) eventually leads to the development of an electric field (streaming electric field) in the direction that is opposite to the direction of the counterion-driven streaming current. The streaming current and the streaming electric field interact to generate the electrokinetic energy. Equally importantly, this streaming electric field induces an EOS transport, which becomes coion-driven, due to the presence of excess coions in the brush-free bulk. For the case of nanochannels grafted with negatively charged PE brushes, the streaming electric field will be in a direction that is opposite to the pressure-driven transport, and hence the coion (or anion) driven EOS flow, will be in the same direction as the pressure-driven transport. On the other hand, for the case of nanochannels grafted with positively charged PE brushes, the streaming electric field will be in the same direction as the pressure-driven flow, and hence the coion (or cation) driven EOS flow, will again be in the same direction as the pressure-driven flow. Therefore, whenever there occurs the presence of the OS and the resulting coion-driven EOS transport in PE brush grafted nanochannels, regardless of the sign of the charges of the PE brushes, this EOS transport will always aid the pressure-driven transport and will cause the most fascinating increase in the net volume flow rate across the nanochannel cross section, which is the electroslippage effect.

overscreening↗

Current rectification by nanoparticles in bipolar nanopores

Bipolar nanochannels comprising two domains of positively and negatively charged walls along the pore axis are known to rectify current when exposed to an electric potential bias. We find that addition of charged nanoparticles can increase rectification considerably, by approximately one order of magnitude. Two bipolar channel geometries are considered here; their behavior is examined at rest and under the influence of a negative bias and a positive bias, respectively. We do so by relying on a molecular-level model of the electrolyte solution in the channels. The large increase in current rectification can be explained by the inherent electric field that charged nanoparticles generate within the channel. This effect is found to be largely dependent on the pore's geometry, its charge distribution, and the sign of the nanoparticles' charge, thereby offering new opportunities for design of engineered nanopore membrane-nanoparticle systems for energy storage.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

In-situ tunable giant electrical anisotropy in a grating gated AlGaN/GaN two-dimensional electron gas.

Materials with in-plane electrical anisotropy have great potential for designing artificial synaptic devices. However, natural materials with strong intrinsic in-plane electrical anisotropy are rare. We introduce a simple strategy to produce extremely large electrical anisotropy via grating gating of a semiconductor two-dimensional electron gas (2DEG) of AlGaN/GaN. We show that periodically modulated electric potential in the 2DEG induces in-plane electrical anisotropy, which is significantly enhanced in a magnetic field, leading to an ultra large electrical anisotropy. This is induced by a giant positive magnetoresistance and a giant negative magnetoresistance under two orthogonally oriented in-plane current flows, respectively. This giant electrical anisotropy is in situ tunable by tailoring both the grating gate voltage and the magnetic field. Our semiconductor device with controllable giant electrical anisotropy will stimulate new device applications, such as multi-terminal memtransistors and bionic synapses.

36 MATERIALS SCIENCE↗

Fault-tolerant grid frequency measurement algorithm during transients

A system determines the frequency of grid signals corresponding to an electrical grid in real time. The system includes a transient detector that monitors a grid signal from a voltage meter or a current meter connected to the electrical grid. The system produces, in real time and at a sampling rate, a deviation signal indicative of a periodicity of the monitored grid signal. The system determines, over one or more cycles of the monitored grid signal, a measurement signal corresponding to the deviation signal. The system determines a frequency signal that corresponds a frequency estimation of the monitored signal by applying a frequency estimation when values of the measurement signal are less than a deviation threshold and maintaining the frequency signal at a constant value when values of the measured signal equal or exceeds the deviation threshold.

Zhan, Lingwei↗

A study on sub-bandgap photoexcitation in nitrogen- and boron-doped diamond with interdigitated device structure

Diamond is an ultrawide-bandgap semiconductor suitable for high power devices that require high current carrying capacity, high blocking voltages, and smaller form factors. We investigated various diamond structures for extrinsic photoconductive semiconductor switches, including an insulating high-pressure high-temperature type Ib (highly nitrogen-doped) substrate, a chemical vapor deposited (CVD) type IIa (unintentionally doped) substrate, a CVD grown semiconducting boron-doped epilayer on a type IIa substrate, and boron-implanted type Ib and IIa substrates. Using these samples, we fabricated and characterized planar interdigitated photoconductive switches with 30 μm, electrode gaps. 532 and 1064 nm Nd:YAG laser pulses with energies up to 3.5 mJ/pulse were used to trigger the switches. Photoresponses were measured at bias voltages ranging from 10 to 100 V, corresponding to electric fields of 3.3–33 kV/cm. In this field range, the type Ib device exhibited the highest average on/off-state current ratio, on the order of 10 11 , when triggered with 0.8 mJ/pulse, 532 nm laser pulses. However, only the CVD grown boron-doped epilayer and boron implanted IIa devices showed decent sensitivity to 1064 nm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cyber Resilient Flexible Alternating Current Transmission Systems (XFACTS)

This report summarizes the activities conducted under the DOE-OE funded project DEOE0000897, Cyber Attack Resilient Flexible AC Systems – XFACTS. Hitachi Energy (HE), in collaboration with ABB Inc. (ABB), Bonneville Power Administration (BPA), University of Illinois at Urbana-Champaign (UIUC), Iowa State University (ISU), and University of Idaho (UI) pursued the development of a system of defense for Flexible Alternating current Transmission Systems against cyber-attacks (XFACTS). A FACTS substation enhanced with XFACTS defense mechanisms will be capable of mitigating cyberattacks especially those that seek to control electrical parameters like voltage or current and interrupt the power flow in AC lines. It empowers existing FACTS controllers and associated intelligent electronic devices to detect and mitigate malicious intents to depress system voltages, destabilize power flows, trip AC circuit breakers, corrupt currents, and voltages, even if the malicious commands and the measurements have correct syntax. The XFACTS functions utilize the physics of active power electronic systems, control and protection, electric power engineering principles, and state estimation to bring more in-depth cyber defense closer to the protected FACTS substation devices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Forming Inverter With Increased Short-Circuit Contribution to Address Inverter-Based Microgrid Protection Challenges

Substantial differences in fault levels between grid-tied and islanded modes is one of the primary challenges of microgrid protection. During grid-tied mode, the bulk grid provides significant short-circuit, while during islanded operation the short-circuit magnitude is small due to inverter-based resources limiting their current output close to nominal ratings. Consequently, conventional distribution protection strategies based on overcurrent cannot reliably protect microgrids when operating in islanded mode. Fuses and circuit breakers are particularly affected because of their inverse characteristics. Presently, the absence of affordable solutions for protecting microgrids in islanded mode leads to microgrids shutting down during electrical faults. The contribution of this article is two-fold. The first innovation proposes specific hardware modifications to grid-forming inverters to increase their short-circuit current during electrical faults. The second innovation introduces a novel control strategy designed to preserve control stability margins even when the grid-filter saturates, ensuring sinusoidal output currents under normal and fault conditions. Through experimental results, the inverter with the proposed modifications can provide more than three-times its nominal current during electrical faults. For the prototype testbed, this was sufficient to enable the use of traditional legacy overcurrent protection, achieving the fuse-to-relay and relay-to-relay minimum coordination time for the line-to-ground, line-to-line to ground, and three-phase electrical faults.

42 ENGINEERING↗

The Global Technical, Economic, and Feasible Potential of Renewable Electricity

Renewable electricity generation will need to be rapidly scaled to address climate change and other environmental challenges. Doing so effectively will require an understanding of resource availability. We review estimates for renewable electricity of the global technical potential, defined as the amount of electricity that could be produced with current technologies when accounting for geographical and technical limitations as well as conversion efficiencies; economic potential, which also includes cost; and feasible potential, which accounts for societal and environmental constraints. We consider utility-scale and rooftop solar photovoltaics, concentrated solar power, onshore and offshore wind, hydropower, geothermal electricity, and ocean (wave, tidal, ocean thermal energy conversion, and salinity gradient energy) technologies. We find that the reported technical potential for each energy resource ranges over several orders of magnitude across and often within technologies. Therefore, we also discuss the main factors explaining why authors find such different results. According to this review and on the basis of the most robust studies, we find that technical potentials for utility-scale solar photovoltaic, concentrated solar power, onshore wind, and offshore wind are above 100 PWh/year. Hydropower, geothermal electricity, and ocean thermal energy conversion have technical potentials above 10 PWh/year. Rooftop solar photovoltaic, wave, and tidal have technical potentials above 1 PWh/year. Salinity gradient has a technical potential above 0.1 PWh/year. The literature assessing the global economic potential of renewables, which considers the cost of each renewable resource, shows that the economic potential is higher than current and near-future electricity demand. Fewer studies have calculated the global feasible potential, which considers societal and environmental constraints. While these ranges are useful for assessing the magnitude of available energy sources, they may omit challenges for large-scale renewable portfolios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Townsend to glow discharge transition for a nanosecond pulse plasma in helium: space charge formation and resulting electric field dynamics

Stark polarization spectroscopy is used to investigate the temporal evolution of the electric field distribution in the cathode region of a nanosecond pulsed discharge in helium at 120 Torr. The measurements are performed on the He I transition at 492.19 nm, during the early stages of the discharge formation. The experimental results are compared with the predictions of a 1D fluid model. Time-resolved ICCD images show that the discharge develops as a diffuse, cathode-directed ionization wave with a Townsend-like feature before transitioning into a glow-like structure. Near anode instabilities characterized by filament formation were observed near the high voltage electrode. Within 30 ns, a reduction of the sheath thickness to about 250 μm is observed, coinciding with a gradual increase of the discharge current and proportional increase in electric field at the cathode. Additionally, the cathode electric field corresponding to this sheath with a thickness of 250 μm is about 40 kV cm -1 . A subsequent steep increase of the discharge current leads to a further reduction of the sheath width. The electric field evolution as obtained by the fluid model is in excellent agreement with the measurements and shows that an enhanced ionization near the cathode is causing the space charge formation responsible for the increase in electric field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Transformational Natural Gas Fueled Dynamic SOFC for Data Center in-Rack Power (Final Technical Report)

Data centers consume 250TWh or 1% of global electricity use in 2019. This electricity demand is expected to grow exponentially in the future. The current data center power supply relies on electric grids with diesel engines and batteries as backup; the latter is critically important because a sudden loss of power could erase crucial data, causing catastrophic economic loss. However, such a double protection architecture is costly, inefficient and polluting. In search for better in-rack power system, fuel-cell based generators have recently emerged as a promising alternative to diesel engines and batteries because of its potential to be more cost-effective, more efficient and less polluting. Among many types of fuel cells, solid oxide fuel cells stand out to be a front runner because of their ability to directly operate on natural gas that has an existing infrastructure. However, there are several critical challenges facing SOFC generators to meet the rigorous power requirements of data centers: high cost, poor reliability and more importantly, slow response to the datacenters’ dynamic load change. The unexpected overload conditions in data centers can cause fuel starvation; the latter can initiate microcracks in the anode structure, thus jeopardizing the lifetime of the SOFC generator. The current efforts to increase transient power capabilities of traditional SOFCs and therefore protect SOFC stacks from internal damage during transient loading, rely primarily upon mathematical algorithms. One of the challenges to these control methodologies is the physical limitations of the fuel delivery system such as slow response of mass flow controllers to fast power demand.

30 DIRECT ENERGY CONVERSION↗