Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diffraction tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

568 records · Page 32

On the high-temperature stability of the Al 8 Cu 3 Ce intermetallic in an additively manufactured Al-Cu-Ce-Zr alloy

High-temperature resistant eutectic Al alloys are crucial materials for lightweight and energy efficient design in the automotive and aviation industries. Additive manufacturing offers a pathway to refine eutectic microstructures and develop novel alloys with superior high-temperature strength. High-volume fraction intermetallic Al-Cu-Ce alloys have been developed to deliver high-temperature strength in combination with reduced hot-tearing susceptibility. Zr is added to provide additional strengthening via nanoscale Al 3 Zr precipitation, and to stabilize and avoid coarsening of the Al 8 Cu 3 Ce phase. However, the detailed interaction between Zr and Al 8 Cu 3 Ce remains unexplored. In this work, we show with synchrotron X-ray diffraction that laser powder bed fusion fabricated Al-Cu-Ce and Al-Cu-Ce-Zr alloys contain predominantly the Al 8 Cu 3 Ce intermetallic in the as-fabricated condition. Heat treatment of the Al-Cu-Ce alloy results in the Al 8 Cu 3 Ce → Al 8 Cu 4 Ce phase transformation. In the Al-Cu-Ce-Zr alloy, minor fractions of (Al,Cu,Si) 4 Ce and Al 2 Cu-θ are found in the as-fabricated condition, while Al 8 Cu 3 Ce remains stable during heat treatment. Atom probe microscopy quantifies intermetallic stoichiometries and reveals how Zr is enriched at the Al-matrix/Al 8 Cu 3 Ce interface acting as a diffusion barrier against solute exchange. Calibrated thermodynamic modeling underpins this as a kinetic effect. Here, a qualitative microstructural model summarizes, how Zr stabilizes Al 8 Cu 3 Ce against phase transformations and coarsening.

36 MATERIALS SCIENCE↗

Imaging in 3D under pressure: a decade of high-pressure X-ray microtomography development at GSECARS

The high-pressure X-ray microtomography (HPXMT) apparatus has been operating at the GeoSoilEnviroCARS (GSECARS) bending magnet beamline at the Advanced Photon Source since 2005. By combining the powerful synchrotron X-ray source and fast switching between white (for X-ray diffraction) and monochromatic (for absorption imaging) modes, this technique provides the high-pressure community with a unique opportunity to image the three-dimensional volume, texture, and microstructure of materials under high pressure and temperature. The ability to shear the sample with unlimited strain by twisting the two opposed anvils in the apparatus allows shear deformation studies under extreme pressure and temperature to be performed. HPXMT is a powerful tool for studying the physical properties of both crystalline and non-crystalline materials under high pressure and high temperature. Over the past 10 years, continuous effort has been put into technical development, modifications to improve the overall performance, and additional probing techniques to meet users’ needs. Here in this paper, we present an up-to-date report on the HPXMT system, a brief review of some of its many exciting scientific applications, and a discussion of future developments.

47 OTHER INSTRUMENTATION↗

Second Annual Progress Report on Correlation Between Microstructure and Mechanical Properties of Neutron-Irradiated Ferritic-Martensitic and Austenitic Steels

Ferritic-martensitic steels G92-2b (an optimized Grade 92 heat), NF616 and T91, and austenitic stainless steel 800H and its Grain Boundary Engineering (GBE)-treated version 800H-TMP (ThermoMechanical Processing) were irradiated in the High Flux Isotope Reactor (HFIR) of Oak Ridge National Laboratory (ORNL) and the Advanced Test Reactor (ATR) of Idaho National Laboratory (INL). Selected G92-2b samples were irradiated up to 14.66 dpa in the HFIR at two temperature ranges: 400–496.7°C and 683.3– 720°C. NF616 and T91 were irradiated in the ATR up to 8.16 dpa with the irradiation temperatures ranged from 241°C to 447.5°C. Alloy 800H and 800H-TMP samples were irradiated in both the HFIR and the ATR. Selected 800H and 800H-TMP samples had HFIR irradiation to 1.28 dpa at 580°C and ATR irradiation up to 9.12 dpa at 359°C to 431°C. Vickers hardness measurements, fractography, and microstructural characterization were performed on the selected samples in the Low Activation Materials Design and Analysis (LAMDA) laboratory. Radiation-hardening of G92-2b was observed at the lower doses and lower irradiation temperatures (400- 496.7°C), with GB03 (0.52 dpa at 400°C) and GB04 (7.44 dpa at ~490°C) showing ~12% and ~8% hardening, respectively. Softening by ~14% was observed for GB05 (14.66 dpa at 496.7°C). Radiationsoftening of G92-2b was more prevalent at the higher irradiation temperatures (683.3-~720°C), with GB10 (0.46 dpa at 683.3°C), GB11 (7.44 dpa at ~720°C), and GB12 (14.63 dpa at ~720°C) showing ~8%, ~8%, and ~40% softening, respectively. Radiation-hardening of NF616 and T91 was observed with the hardness increased by ~37% to ~65% depending on the irradiation doses and irradiation temperatures. Within the studied irradiation conditions of NF616 and T91, samples with a higher dose had a larger hardness after irradiation. All the tested alloy 800H and 800H-TMP samples in this work showed radiation-hardening by ~96±7% to ~152±10%. Alloy 800H-TMP tended to have slightly smaller radiation-hardening than alloy 800H. The fractography results of G92-2b sample GB03, GB10, and GB11, together with the previously characterized fractography of GB04, GB05, and GB12, indicated that the ductility of G92-2b was maintained up to 14.66 dpa at the lower irradiation temperatures of 400-496.7°C, while some loss of ductility (less necking) was observed for higher doses at the higher irradiation temperatures of 683.3-720°C. This agrees with the previously reported tensile test results of G92-2b, where the elongation of G92-2b was reduced at higher doses at the higher irradiation temperatures. Dimple sizes increased at higher doses, which are more evident at the higher irradiation temperatures of 683.3-~720°C. The fractography of NF616 sample D2 (2.96 dpa at 291.5°C), D4 (5.91 dpa at 359°C), and D6 (8.16 dpa at 431°C) indicated loss of ductility with negligible necking for sample D2, while ductile failure for samples D4 and D6. Fractography of alloy 800H and 800H-TMP samples in various irradiation conditions showed ductile failure with obvious necking. Dimples were observed, with some of them containing large Ti-rich particles, in all the 800H/800H-TMP samples. Electron backscatter diffraction characterization of GB12 indicated the recovery of the lath structure, which was generally replaced by an equiaxed grain structure. Transmission electron microscopy (TEM) characterization showed the presence of frequent M 23 C 6 (M = primarily Cr), MX (M = primarily V), spherical Nb(C,N) precipitates, and occasional Laves phase precipitates in the G92-2b samples. MX precipitates with sizes of 20-30 nm were observed at boundaries of smaller grains, indicating the pinning effect of the V-rich precipitates. The lath structure recovery was more evident at the higher irradiation temperatures (683.3-~720°C), with decreased densities of line dislocations and M23C6 precipitates. The irradiated T91 (TA04) showed the growth of M23C6 precipitates to 101 ± 40 nm from the initial 68 ± 22 nm in the unirradiated condition. Dislocation loops of both {100} and {111} types were present in TA04. TEM characterization was also performed on the irradiated 800H (N4, N5, N6, and AR2) and 800H-TMP (P4, P5, P6, and HG1). Accumulation of M 23 C 6 precipitates at grain boundaries was observed in all the xii 800H/800H-TMP samples, and the presence of Ti(C,N) precipitates at grain boundaries and in the matrix was observed in the irradiated 800H-TMP. Some Ti(C,N) precipitates are embedded in the M 23 C 6 precipitates, maintaining specific orientation relationships between the precipitates and between the precipitate and matrix. In addition, nanoscale Si-rich clusters were observed in the matrix of all the 800H/800H-TMP samples, with EDS Si maps tending to have a lower contrast in 800H-TMP samples. Atom probe tomography was conducted on the same samples, supported by a Rapid Turnaround Examination project under Nuclear Science User Facilities. The results are being analyzed to be integrated with the TEM results for a confident description of the γ’ precipitates. Dislocation loops also formed in all the 800H/800H-TMP samples. The density and the average size of dislocation loops were quantified to be in the order of 10 22 – 10 23 m -3 and 11.7 – 15.9 nm, respectively, in the ATR-irradiated 800H/800H-TMP samples. The loop densities in irradiated 800H were higher than that in irradiated 800H-TMP under the same irradiation conditions. Further systematic data analyses, together with some complementary experiments, will be pursued for these samples to foster peer-reviewed journal article publications.

36 MATERIALS SCIENCE↗

Particle shape inhomogeneity and plasmon-band broadening of solar-control LaB{sub 6} nanoparticles

An ensemble inhomogeneity of non-spherical LaB{sub 6} nanoparticles dispersion has been analyzed with Mie theory to account for the observed broad plasmon band. LaB{sub 6} particle shape has been characterized using small-angle X-ray scattering (SAXS) and electron tomography (ET). SAXS scattering intensity is found to vary exponentially with exponent −3.10, indicating the particle shape of disk toward sphere. ET analysis disclosed dually grouped distribution of nanoparticle dispersion; one is large-sized at small aspect ratio and the other is small-sized with scattered high aspect ratio, reflecting the dual fragmentation modes during the milling process. Mie extinction calculations have been integrated for 100 000 particles of varying aspect ratio, which were produced randomly by using the Box-Muller method. The Mie integration method has produced a broad and smooth absorption band expanded towards low energy, in remarkable agreement with experimental profiles by assuming a SAXS- and ET-derived shape distribution, i.e., a majority of disks with a little incorporation of rods and spheres for the ensemble. The analysis envisages a high potential of LaB{sub 6} with further-increased visible transparency and plasmon peak upon controlled particle-shape and its distribution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

First Examination of Irradiated Fuel with Pulsed Neutrons at LANSCE (Preliminary Results)

We present preliminary results on the characterization of an irradiated U-lOZr-lPd fuel sample that was prepared from the irradiated AFC-3A-R5A sample. U-lOZr metallic fuels are researched as host materials for potential transmutation fuels and the addition of palladium strives to bind lanthanides, thus preventing fuel-cladding chemical interactions (FCCI). These interactions limit the lifetime of metallic fuels and are caused by migration of lanthanide fission products to the periphery of the fuel slug, where they start to interact with the D9 or HT9 steel cladding, ultimately leading to failure of the mechanical integrity of the cladding. Neutrons offer bulk characterization of irradiated materials for which X-ray tomography methods are not suitable due to the immense gamma background emitted from the samples. In particular pulsed neutrons provide information from the ability to resolve the neutron energy using their time-of-flight and thus the potential to utilize neutron absorption resonance to characterize the spatial distribution of isotopes. This, in turn, may allow to characterize the distribution of fission and neutron capture products non-destructively and may ultimately be applied to the bulk of an irradiation capsule prior to destructive post-irradiation examination to identify regions of interest. To allow the characterization of entire irradiation capsules, a cask is under development in the advanced post-irradiation work package at LANL and progress on this development was reported elsewhere. In parallel, an irradiated U-lOZr-lPd sample cut from the AFC-3AR5A irradiation was shipped to LANL and will be fully characterized with an NSUF funded rapid turnaround experiment (RTE) in the 2020 LANSCE run cycle. The sample emits at a dose rate of ~3R/hr on contact and is therefore manageable with remote handling, without requiring a cask. The disk-shaped material is larger than samples prepared for analysis using electron or X-ray methods and is therefore an intermediate step towards characterization of bulk samples at LANSCE. However, since it covers the full diameter of the irradiated fuel slug, some insight on redistribution of elements, spatially resolved information on microstructure, e.g. phase composition and texture, will be possible using the pulsed neutron-based methods developed for fuel characterization at LANSCE. This report describes the development of procedures to handle the sample at LANSCE as well as preliminary data and results from tests conducted in December 2019 on the energy-resolved neutron imaging (ERNI) beam line at flight path 5 and the high pressure-preferred orientation diffractometer (HIPPO) at LANSCE. This effort is a collaboration between LANL, INL, and ORNL. To compare our capabilities with prior work, we present an overview of previously reported bulk characterization of irradiated or spent fuels. The overview addresses neutron diffraction and neutron absorption resonance spectroscopy, both of which have only few reported applications on irradiated or spent nuclear fuel, as well as neutron radiography. This literature review was already described in a previous report but is repeated here to put our current efforts in context of previous work.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Subgrain geometrically necessary dislocation density mapping in spalled Ta in three dimensions

Here, in this work, the intragranular distributions of the densities of geometrically necessary dislocations (GNDs) generated in a polycrystalline tantalum (Ta) sample loaded in shock compression to spall are investigated. The sample studied is a highly resolved three-dimensional (3D) map of the orientations, grain boundary morphology, and voids across a 0.276mm 3 (with sample dimensions of 688.5µm x 669µm x 600µm) region of the microstructure about the spall plane obtained by TriBeam tomography. We present a formulation for calculating the crystallographic screw and edge character GND densities at a material point within body centered cubic (BCC) crystals when provided any number of potential slip systems or modes. Combining the 3D characterization, GND formulation, and a sample containing ≈ 6000 grains, we sought statistically relevant correlations between GND density per grain with grain size, grain orientation, void formation, and proximity from the spall plane. We show that GND density per grain increases with decreasing distance from the spall plane. Most grains had heterogeneously distributed GND densities but were free of any detectable voids, at least within the ≈ 1.5µm resolution of the characterization technique. It is found that the GND density for most grains is insensitive to grain size and grain orientation. Only the fraction of grains with the highest GND densities tended to have a [001] parallel to shock-direction orientation. Intragranular 3D maps of GNDs reveals that grains that contain voids have high GND density concentrations in the intragranular region immediately surrounding the void. The local intragranular GND mapping also showed voids that are connected to grain boundaries preferred to grow into the grain with the larger size, regardless of orientation.

36 MATERIALS SCIENCE↗

A high-resolution analytical scanning transmission electron microscopy study of the early stages of spinodal decomposition in binary Fe–Cr

Spinodal decomposition (SD) is an important phenomenon in materials science and engineering. For example, it is considered to be responsible for the 475 °C embrittlement of stainless steels comprising the bcc (ferrite) or bct (martensite) phases. Structural characterization of the evolving minute nano-scale concentration fluctuations during SD in the Fe–Cr system is, however, a notable challenge, and has mainly been considered accessible via atom probe tomography (APT) and small-angle neutron scattering. The standard tool for nanostructure characterization, viz. transmission electron microscopy (TEM), has only been successfully applied to late stages of SD when embrittlement is already severe. However, we here demonstrate that the structural evolution in the early stages of SD in binary Fe–Cr, and alloys based on the binary, are accessible via analytical scanning TEM. An Fe–36 wt% Cr alloy aged at 500 °C for 1, 10 and 100 h is investigated using an aberration-corrected microscope and it is found that highly coherent and interconnected Cr-rich regions develop. The wavelength of decomposition is rather insensitive to the sample thickness and it is quantified to 2, 3 and 6 nm after ageing for 1, 10 and 100 h, which is in reasonable agreement with prior APT analysis. The concentration amplitude is more sensitive to the sample thickness and acquisition parameters but the TEM analysis is in good agreement with APT analysis for the longest ageing time. These findings open up for combinatorial TEM studies where both local crystallography and chemistry is required. - Highlights: • STEM-EELS analysis was successfully applied to resolve early stage SD in Fe–Cr. • Compositional wavelength measured with STEM-EELS compares well to previous ATP studies. • Compositional amplitude measured with STEM-EELS is a function of experimental parameters. • STEM-EELS allows for combinatorial studies of SD using complementary techniques.

36 MATERIALS SCIENCE↗

Cathode Upcycling for Direct Recycling of Lithium‐Ion Batteries Using a Precipitation Approach

With the increased production of electric vehicles to reduce carbon emissions, the lithium-ion battery market to supply those vehicles has grown dramatically. To enhance battery sustainability and circularity, direct recycling methods aim to recover intact cathode materials. However, end-of-life cathode materials are typically 15–20 years old and often have lower energy density compared to current cathode materials. To address this challenge, a rapid precipitation process is developed to boost energy density by converting low Ni-compositions, LiNi 0.33 Co 0.33 Mn 0.33 O 2 (NMC111), into higher Ni-compositions (NMC622). This process forms a Ni-rich coating on cathode particles that diffuses into the core upon high-temperature relithiation, increasing compositional homogeneity. The upcycling process leverages existing infrastructure, offering low capital cost and minimal additional chemical input. Through ex situ tomographic transmission X-ray microscopy (TXM), 3D Ni:Co elemental mixing is quantified, confirming that elemental content evens at the secondary particle level with a mean NMC622 composition upon relithiation. However, elemental gradients remain in the single crystalline primary particles. Ex situ high-resolution and in situ wide-angle X-ray diffraction reveals concurrent structural changes during the relithiation process. These findings provide key insights into the structural and chemical mechanisms of elemental diffusion to obtain further improvements of increased capacity and retention through compositional conversion of cathode materials.

Cathode Upcycling↗

LOW SCATTER, HIGH KILOVOLT, A-SI FLAT PANEL X-RAY DETECTOR

We have been using amorphous silicon (a-Si) flat panel detectors in high energy (>400 kV) cone beam computed tomography (CT) applications for a number of years. We have found that these detectors have a significant amount of internal scatter that degrades the accuracy of attenuation images. The scatter errors cause cupping and streaking artifacts that are practically indistinguishable from beam hardening artifacts. Residual artifacts remain after beam hardening correction and over correction increases noise in CT reconstructions. Another important limitation of existing detectors is that they have a high failure rate, especially when operating at megavolt x-ray energies even with a well collimated beam. Due to the limitations of the current detectors, we decided to design a detector specifically for high energies that has significantly reduced scatter. In collaboration with IMTEC, we have built a prototype amorphous silicon flat panel detector that has both improved imaging response and increased lifetime. LANL's contribution is the ''transparent panel concept''(patent pending), in which structures in the x-ray beam path are either eliminated or made as transparent to x-rays as practical (low atomic number and low areal density). This reduces scatter, makes attenuation measurements more accurate, improves the ability to make corrections for beam hardening, and increases signal to noise ratio in DR images and CT reconstructions. IMTEC's contribution is an improved shielding design that will increase the lifetime of the panel. Preliminary results showing the dramatic reduction in self scatter from the panel will be presented as well as the effect of this improvement on CT images.

36 MATERIALS SCIENCE↗

TH-AB-209-07: High Resolution X-Ray-Induced Acoustic Computed Tomography

Purpose: X-ray radiographic absorption imaging is an invaluable tool in medical diagnostics, biology and materials science. However, the use of conventional CT is limited by two factors: the detection sensitivity to weak absorption material and the radiation dose from CT scanning. The purpose of this study is to explore X-ray induced acoustic computed tomography (XACT), a new imaging modality, which combines X-ray absorption contrast and high ultrasonic resolution to address these challenges. Methods: First, theoretical models was built to analyze the XACT sensitivity to X-ray absorption and calculate the minimal radiation dose in XACT imaging. Then, an XACT system comprised of an ultrashort X-ray pulse, a low noise ultrasound detector and a signal acquisition system was built to evaluate the X-ray induced acoustic signal generation. A piece of chicken bone and a phantom with two golden fiducial markers were exposed to 270 kVp X-ray source with 60 ns exposure time, and the X-ray induced acoustic signal was received by a 2.25MHz ultrasound transducer in 200 positions. XACT images were reconstructed by a filtered back-projection algorithm. Results: The theoretical analysis shows that X-ray induced acoustic signals have 100% relative sensitivity to X-ray absorption, but not to X-ray scattering. Applying this innovative technology to breast imaging, we can reduce radiation dose by a factor of 50 compared with newly FDA approved breast CT. The reconstructed images of chicken bone and golden fiducial marker phantom reveal that the spatial resolution of the built XACT system is 350µm. Conclusion: In XACT, the imaging sensitivity to X-ray absorption is improved and the imaging dose is dramatically reduced by using ultrashort pulsed X-ray. Taking advantage of the high ultrasonic resolution, we can also perform 3D imaging with a single X-ray pulse. This new modality has the potential to revolutionize x-ray imaging applications in medicine and biology.

60 APPLIED LIFE SCIENCES↗