Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Image plate multi-scan response to fusion protons in the range of 1–14 MeV

Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.

Instruments & Instrumentation↗

Neutrino Interactions observed with Large Area Picosecond Photodetectors in ANNIE

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton water-based neutrino detector located at Fermilab, approximately 110 m downstream of the Booster Neutrino Beam (BNB). ANNIE utilizes both photomultiplier tubes (PMTs) and advanced photodetectors, specifically Large Area Picosecond Photodetectors (LAPPDs), to detect Cherenkov light emitted by leptons produced in neutrino interactions within ANNIE. LAPPDs are a novel technology designed to detect photons with picosecond-level temporal resolution and sub-millimetre spatial precision. Multiple LAPPDs have been deployed in the ANNIE detector. This is the first use of this technology in a running particle physics experiment and has yielded the first detection of light from neutrino interactions in water with LAPPDs. In this poster, I will showcase the operational performance and functionality of LAPPDs in the ANNIE experiment. Neutrino beam data from the BNB is used to evaluate the timing precision, hit reconstruction performance, and beam response of deployed LAPPDs, demonstrating how this novel picosecond-resolution technology performs in a running neutrino water Cherenkov detector. This work highlights the successful integration of LAPPDs in ANNIE and provides quantitative benchmarks that inform their application in future neutrino experiments requiring high-resolution photon detection.

Aman, Mohammad Adil [Florida State U.] (ORCID:0009↗

A Review of the Multiple-Readout Concept and Its Application in an Integrally Active Calorimeter

A comprehensive multi-jet physics program is anticipated for experiments at future colliders. Key physics processes necessitate detectors that can distinguish signals from W and Z bosons and the Higgs boson. Typical examples include channels with or pairs and processes involving new physics in those cases where neutral particles must be disentangled from charged ones due to the presence of W or Z bosons in their final states. Such a physics program demands calorimetric energy resolution at or beyond the limits of traditional calorimetric techniques. Multiple-readout calorimetry, which aims to reduce fluctuations in energy measurements of hadronic showers, is a promising approach. The first part of this article reviews dual- and triple-readout calorimetry within a mathematical framework describing the underlying compensating mechanism. The second part proposes a potential implementation using an integrally active and total absorption detector. This model serves as the basis for several Monte Carlo studies, illustrating how the response of a multiple-readout calorimeter depends on construction parameters. Among the layouts considered, one configuration operating in triple-readout mode shows the potential to achieve an energy resolution approaching .

47 OTHER INSTRUMENTATION↗

System and methods for deploying payloads

Embodiments of the present invention include systems for launching primary or secondary payloads or actuating other launch vehicle or payload or instrumentation devices. The system includes an adapter assembly and at least one sequencer mounted to the adapter assembly. The sequencer includes: controller boards, each of the controller boards having a controller for controlling deployment of the payloads and data files; output ports coupled to the controller boards and configured to transmit signals from the controller boards to dispensers therethrough, deployment mechanisms containing the payloads, the adapter assembly having channels for accommodating the dispensers; and a detector coupled to the controller boards and adapted to detect an external signal and, in response to the external signal, to send an initiation signal to the controller boards. The system also includes at least one power supply coupled to the sequencer and adapted to provide an electrical power to the sequencer.

42 ENGINEERING↗

Luminosity measurement for lead-lead collisions at $\sqrt{s_{\mathrm{NN}}}$ = 5.02 TeV in 2015 and 2018 at CMS

Measurements of the luminosity delivered to the CMS experiment during the lead-lead data-taking periods in 2015 and 2018 are presented for the first time. The collisions were recorded at a nucleon-nucleon center-of-mass energy of 5.02 TeV; the 2018 data sample is three times larger than the 2015 data sample. Three subdetectors are used: the pixel luminosity telescope, the forward hadron calorimeters, and the fast beam conditions monitor. The absolute luminosity calibration is determined using the van der Meer technique that relies on transverse beam separation scans. The dominant sources of uncertainty are the transverse factorizability of the bunch density profiles and, in 2015, the difference between the results obtained using various detectors. The total uncertainty in the integrated luminosity, including the stability of the calibrated subdetector response over time, amounts to 3.0% for 2015, 1.7% for 2018, and 1.6% for the combined data sample.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The KIPM Detector Consortium

Kinetic Inductance Phonon-Mediated (KIPM) Detectors, microcalorimeters that leverage kinetic inductance detectors (KIDs) to read out phonon signals from the device substrate, are an attractive architecture for low-threshold rare-event searches due to their large response to small changes in quasiparticle density and native multiplexability, enabling scalability. We have established a consortium comprising university and national lab groups dedicated to advancing the state-of-the-art in these detectors, with the ultimate goal of designing a detector with a kg-scale target mass and sub-eV threshold on energy deposited in the substrate, enabling searches for both light dark matter and low-energy neutrino interactions. This consortium brings together experts in KID design, phonon and quasiparticle dynamics, and noise modeling, along with specialized fabrication facilities, test platforms, and unique calibration capabilities. Recently, our consortium has demonstrated a sensor resolution (i.e., resolution in the quasiparticle channel) of 2.1 eV, the current record for such devices. The current focus of the consortium is modeling and improving the phonon collection efficiency and implementing low-Tc superconductors, both of which serve to improve the overall energy resolution and threshold of the detectors. In this talk, I will provide an overview of the consortium and its capabilities, highlight some recent results from its member groups, and discuss near term plans toward reaching the ultimate goal.

Temples, Dylan J. [Fermilab]↗

Thermal and radiation response of 4H–SiC Schottky diodes with direct-write electrical contacts

In this work, a high-sensitivity 4H–SiC temperature sensor and an alpha detector have been fabricated using additively printed metal contacts. The surface morphology and electrical conductivity of the printed electrodes were established prior to Schottky diode development. 4H–SiC Schottky diodes with direct-write printed silver contacts on the 5 μ m-thick epilayer on 4H–SiC were characterized electrically in terms of the forward and reverse current–voltage and high-frequency capacitance–voltage characteristics. Furthermore, the turn-on voltage of the Schottky diodes, as established from the forward current–voltage characteristics measured up to a temperature of 400 °C, showed a linear temperature dependence. Schottky diodes with direct-write printed Ag electrodes were able to measure alpha particles emitted from Americium-241. The high temperature and radiation response of the Schottky diodes show their suitability for multi-modal sensor fusion on the 4H–SiC platform for harsh environment applications.

42 ENGINEERING↗

Adaptive spectra-to-exposure conversion using ridge regularized polynomial response models

Real-time gamma spectra-to-exposure conversion in aerial and ground monitoring commonly relies on calibration-derived, detector- or system-specific conversion coefficients that are assumed to generalize across operational environments. In practice, deployment specific differences in spectral composition and transport conditions can introduce systematic bias relative to reference instruments, motivating methods that adapt coefficients using minimal field supervision while explicitly limiting overfitting. In this work, we present a conservative coefficient adaptation framework that updates a baseline polynomial energy-weighting function using ridge-regularized regression, with leave-one-out cross-validation (LOOCV) used to select the regularization strength. The findings support ridge-constrained minimal-supervision adaptation as a practical mechanism to suppress site-specific bias without destabilizing a calibration-derived baseline.

61 RADIATION PROTECTION AND DOSIMETRY↗

Nuclear Recoil Calibration at Sub-keV Energies in LUX and Its Impact on Dark Matter Search Sensitivity

Dual-phase xenon time projection chamber (TPC) detectors offer heightened sensitivities for dark matter detection across a spectrum of particle masses. To broaden their capability to low-mass dark matter interactions, we investigated the light and charge responses of liquid xenon (LXe) to sub-keV nuclear recoils. Using neutron events from a pulsed Adelphi Deuterium-Deuterium neutron generator, an in situ calibration was conducted on the LUX detector. We demonstrate direct measurements of light and charge yields down to 0.45 keV and 0.27 keV, respectively, both approaching single quanta production, the physical limit of LXe detectors. Furthermore, these results hold significant implications for the future of dual-phase xenon TPCs in detecting low-mass dark matter via nuclear recoils.

Dark matter detectors↗

Development of a Neutron List Mode Collar (LMCL) and a List Mode Response Matrix Analysis Concept

This report was prepared for the Safeguards Program of the US Department of Energy’s (DOE’s) National Nuclear Security Administration (NNSA), Office of Defense Nuclear Nonproliferation Research and Development (DNN R&D). The report presents the development of the neutron nondestructive assay system, the List Mode Collar (LMCL) for the project OR16-List Mode for Collar-PD1La “List Mode Response Matrix for Advanced Correlated Neutron Analysis for Nuclear Safeguards.” The new list mode electronics developed under this project, and a spatial analysis concept called the List Mode Response Matrix are also described in this report. Analysis algorithms based on classification methods are published in a separate report. This research addresses the need to expand the capabilities of current nondestructive assay systems used for nuclear safeguards applications and considers the sustainability of safeguards technologies by the development of a “retrofit” concept using electronics based on modern standards. Furthermore, employing list mode data acquisition enabled the development of a spatial analysis concept and empirical measurement of a spatial response not previously used for safeguards neutron counting applications or measured in a traditional neutron collar detector and, therefore, provides new capability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PbE (E = S, Se) Colloidal Quantum Dot-Layered 2D Material Hybrid Photodetectors

Hybrid lead chalcogenide (PbE) (E = S, Se) quantum dot (QD)-layered 2D systems are an emerging class of photodetectors with unique potential to expand the range of current technologies and easily integrate into current complementary metal-oxide-semiconductor (CMOS)-compatible architectures. Herein, we review recent advancements in hybrid PbE QD-layered 2D photodetectors and place them in the context of key findings from studies of charge transport in layered 2D materials and QD films that provide lessons to be applied to the hybrid system. Photodetectors utilizing a range of layered 2D materials including graphene and transition metal dichalcogenides sensitized with PbE QDs in various device architectures are presented. Figures of merit such as responsivity (R) and detectivity (D*) are reviewed for a multitude of devices in order to compare detector performance. Finally, a look to the future considers possible avenues for future device development, including potential new materials and device treatment/fabrication options.

36 MATERIALS SCIENCE↗

X-ray spectrometer

An x-ray spectrometer includes: an x-ray plasma source that produces first x-rays; an x-ray optic in optical communication with the x-ray plasma source and that: receives the first x-rays from the x-ray plasma source; focuses the first x-rays to produce second x-rays; and communicates the second x-rays to a sample that produces product x-rays in response to receipt of the second x-rays and second light; and a microcalorimeter array detector in optical communication with the sample and that receives the product x-rays from the sample.

Ullom, Joel↗

Reconstruction framework advancements to support streaming for the ePIC detector at the EIC

The ePIC collaboration adopted the JANA2 framework to manage its reconstruction algorithms. This framework has since evolved substantially in response to ePIC’s needs. There have been three main design drivers: integrating cleanly with the Podio-based data models and other layers of the key4hep stack, enabling external configuration of existing components, and supporting timeframe splitting for streaming readout. The result is a unified component model featuring a new declarative interface for specifying inputs, outputs, parameters, services, and resources. This interface enables the user to instantiate, configure, and wire components via an external file. One critical new addition to the component model is a hierarchical decomposition of data boundaries into levels such as Run, Timeframe, PhysicsEvent, and Subevent. Two new component abstractions, Folder and Unfolder, are introduced in order to traverse this hierarchy, e.g. by splitting or merging. The pre-existing components can now operate at different event levels, and JANA2 will automatically construct the corresponding parallel processing topology. This means that a user may write an algorithm once, and configure it at runtime to operate on timeframes or on physics events. Overall, these changes mean that the user requires less knowledge about the framework internals, obtains greater flexibility with configuration, and gains the ability to reuse the existing abstractions in new streaming contexts.

Brei, Nathan [Thomas Jefferson National Accelerato↗

Time Resolution Characterization of 4H-SiC LGADs with a 90 Sr Source

This work presents timing measurements of 4H-SiC Low Gain Avalanche Detectors (4H-SiC LGADs) using beta particles from a 90Sr source. The 4H-SiC LGADs exhibit fast signal responses, and a time resolution of 61 ps was achieved, comparable to that of standard Si LGADs. The present limitation in the time resolution of 4H-SiC LGADs appears to stem from limited charge generation. Nevertheless, their higher voltage tolerance and faster carrier drift suggest that, with increased charge collection, their timing performance could approach or even surpass that of Si LGADs. Furthermore, these results demonstrate the strong potential of 4H-SiC LGADs as a robust platform for precision timing in future 4D tracking detectors, while also highlighting that signal charge is the dominant factor currently limiting their performance, indicating that further optimization of gain and drift structures will be essential for future development.

43 PARTICLE ACCELERATORS↗

Single detector laser-induced fluorescence imager and raman spectral instrument

Apparatus include divergence optics removably coupled to receive a probe beam in a first imaging mode to cause the probe beam to diverge before impinging on a first area of a target surface, and to not receive the probe beam in a second imaging mode to cause the probe beam to impinge on a second area of the target surface smaller than the first area, collection optics configured to receive, in response to the probe beam, luminescence light emitted from the first area and spectral light emitted from the second area, and an optical detector coupled to the collection optics, wherein the optical detector includes a luminescence imaging detector portion and a spectral imaging detector portion adjacent to the luminescence imaging detector portion, wherein the luminescence imaging detector portion is configured to receive the luminescence light emitted from the first area and the spectral imaging detector portion is configured to receive the spectral light from the second area.

Gasda, Patrick J.↗

Outer Radiation Belt Flux and Phase Space Density Response to Sheath Regions: Van Allen Probes and GPS Observations

Turbulent and compressed sheath regions preceding interplanetary coronal mass ejections strongly impact electron dynamics in the outer radiation belt. Changes in electron flux can occur on timescales of tens of minutes, which are unlikely to be captured by a two-satellite mission. The recently released Global Positioning System (GPS) data set generally has shorter revisit times (at L ~ 4–8) owing to the large number of satellites in the constellation equipped with energetic particle detectors. Investigating electron fluxes at energies from 140 keV to 4 MeV and sheaths observed in 2012–2018, we show that the flux response to sheaths on a timescale of 6 hr, previously reported from Van Allen Probes (RBSP) data, is reproduced by GPS measurements. Furthermore, GPS data enables derivation of the response on a timescale of 30 min, which further confirms that the energy and L-shell dependent changes in electron flux are associated with the impact of the sheath. Sheath-driven loss is underestimated over longer timescales as the electrons recover during the ejecta. We additionally show the response of electron phase space density (PSD), which is a key quantity in identifying non-adiabatic loss from the system and electron energization through wave-particle interactions. The PSD response is calculated from both RBSP and GPS data for the 6 hr timescale, as well as from GPS data for the 30 min timescale. The response is divided based on the geoeffectiveness of the sheaths revealing that electrons are effectively accelerated only during geoeffective sheaths, while loss commonly occurs during all sheaths.

79 ASTRONOMY AND ASTROPHYSICS↗

UV hybrid photon detector based on GaN photocathodes and Si low gain avalanche diode

Photon detectors featuring single-photon sensitivity play a crucial role in various scientific domains, including high-energy physics, astronomy, and quantum optics. Fast response time, high quantum efficiency, and minimal dark counts are the characteristics that render them ideal candidates for detecting individual photons with exceptional signal-to-noise ratios, at frequencies in the range of hundreds of MHz. Here, in this study, we report on our first design and operational results on a Hybrid Photon Detector (HPD) that combines the high quantum efficiency of a Gallium Nitride (GaN) photocathode and the low noise characteristics of a Si-based Low-Gain Avalanche Diode (LGAD). This hybrid detection scheme has the potential to reach single-photon detection sensitivity with high quantum efficiency, low noise levels and capable of operating at hundreds of MHz repetition rates.

47 OTHER INSTRUMENTATION↗

Laser calibration of the ATLAS Tile Calorimeter during LHC Run 2

This article reports the laser calibration of the hadronic Tile Calorimeter of the ATLAS experiment in the LHC Run 2 data campaign. The upgraded Laser II calibration system is described. The system was commissioned during the first LHC Long Shutdown, exhibiting a stability better than 0.8% for the laser light monitoring. The methods employed to derive the detector calibration factors with data from the laser calibration runs are also detailed. These allowed to correct for the response fluctuations of the 9852 photomultiplier tubes of the Tile Calorimeter with a total uncertainty of 0.5% plus a luminosity-dependent sub-dominant term. Finally, we report the regular monitoring and performance studies using laser events in both standalone runs and during proton collisions. These studies include channel timing and quality inspection, and photomultiplier linearity and response dependence on anode current.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗