Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Dynamic variations observed in thermal and superthermal ion distributions in the dayside ionosphere of Venus

In-situ measurements of the ion composition and concentration of the ionosphere of Venus are obtained with the Bennett RF ion mass spectrometer (OIMS) on the Pioneer Venus Orbiter (PVO). Dayside ion profiles exhibit considerable variability in the height of the ionopause as well as the scale heights of the ion constituents, which reflect the compression and expansion of the ionosphere in response to solar wind variations. Near the dayside upper boundary of the thermal O+ distribution, super-thermal ions are detected by the OIMS, presenting a complication for identifying the ion signature of the ionopause. Correlated with the presence of the superthermal ions, the ac electric field detector (OEFD) detects regions of intensified signals, with peak response in the 100 Hz frequency channel. It is expected that further analysis of the superthermal ion-electric field signatures will contribute to a clearer understanding of the physical processes underlying the formation of the ionopause.

Taylor, H. A., Jr.↗

Evaluation of Relative Sensitivity of SAW and Flexural Plate Wave Devices for Atmospheric Sensing

The objective of this project is to evaluate the suitability of the ultrasonic flexural plate wave (FPW) device as the detector in a gas chromatograph (GC). Of particular interest is the detection of nitrous oxide (N2O). From experimental results we conclude analyte detection is achieved through two mechanisms: changes in gas density, and mass loading of the device membrane due to the sorption of gas molecules. Reducing the dead volume of the FPW chamber increased the FPW response. A comparison of the FPW response to that of the surface acoustic wave (SAW) detector provided with the GC (made by MSI, Microsensor Technologies, Inc.), shows that for unseparated N2O in N2, the FPW exhibits a sensitivity that is at least 550 times greater than that of the SAW device. A Porapak Q column was found to separate N2O from its carrier gas, N2 or He. With the Porapak Q column, a coated FPW detected 1 ppm N2O in N2 or He, with a response magnitude of 7 Hz. A coated SAW exhibited a response of 25 Hz to pure N2O. The minimal detectable N2O concentrations of the sensors were not evaluated.

White, Richard M.↗

New broadband square-law detector

Compact device has wide dynamic range, accurate square-law response, good thermal stability, high-level dc output with immunity to ground-loop problems, ability to insert known time constants for radiometric applications, and fast response times compatible with computer systems.

Reid, M. S.↗

Evaluation of Space Radiation Effects on HgCdTe Avalanche Photodiode Arrays for Lidar Applications

We report the results from proton and gamma ray radiation testing of HgCdTe avalanche photodiode (APD) arrays developed by Leonardo DRS for space lidar detectors. We tested these devices with both approximately 60 MeV protons and gamma rays, with and without the read out integrated circuit (ROIC). We also measured the transient responses with the device fully powered and with the APD gain from unity to greater than 1000. The detectors produced a large current impulse in response to each proton hit but the response completely recovered within 1 microsecond. The devices started to have persistent damage at a proton fluence of 7e10 protons/cm2, equivalent to 10 krad(Si) total ionization dose. The dark current became much higher after the device was warmed to room temperature and cooled to 80K again, but it completely annealed after baking at 85 C for several hours. These results showed the HgCdTe APD arrays are suitable for use in space lidar for typical Earth orbiting and planetary missions provided that provisions are made to heat the detector chip to 85 C for several hours after radiation damage becomes evident that system performance is impacted.

Sun, Xiaoli↗

Lightning discharge identification system

A system for differentiating between cloud to cloud and cloud to ground lightning discharges is described which includes an electric field antenna that senses the rate of charge of an electric field produced by a lightning discharge. When the signal produced by the electric field exceeds a predetermined threshold, it is fed to a coincidence detector. A VHF antenna is also provided and generates a video signal responsive to a cloud to cloud lightning discharge, and this signal is fed through a level sensor, an inverter, to the coincidence detector simultaneously with the signal from the field detector. When signals from the electric field antenna and the VHF antenna appear at the coincidence detector simultaneously, such indicates that there is a cloud to cloud lightning discharge; whereas, when there is not a signal produced on the VHF antenna simultaneously with a signal produced by the field sensor, then a strike indicator connected to the coincidence detector indicates a cloud to ground lightning discharge.

Lennon, C. L.↗

Aqua MODIS Thermal Emissive Band On-Orbit Calibration, Characterization, and Performance

The NASA's Earth Observing System Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) has continued to operate with satisfactory performance since its launch in May 2002, exceeding its nominal six-year design lifetime. Its continuous Earth observations have been used to generate many science data products for studies of the Earth's, system. MODIS has 36 spectral bands; 20 reflective solar bands and 16 thermal emissive bands (TEBs). All TEB observations are made at 1-km nadir spatial resolution with spectral wavelengths from 3.7 to 14.4 pm. Primary applications of MODIS TEB 'include surface, cloud, and atmospheric temperatures, water vapor, and cloud top altitude. MODIS TEB on-orbit calibration uses a quadratic algorithm with its calibration coefficients derived using an onboard blackbody (BB). This paper will present Aqua MODIS TEB on-orbit calibration, characterization, and performance over its six-year mission. Examples of instrument thermal behavior, BB temperature stability, detector short-term stability, and changes in long-term response (or system gain) will be presented. Comparisons will also be made with Terra MODIS, launched in December 1999. On-orbit results show that Aqua MODIS and its focal plane temperatures have behaved normally. BB temperature has remained extremely stable with typical scan -to-scan variations of less than +/-0.15 mK. Most TEB detectors continue to exceed their specified signal-to-noise ratio requirements, exhibiting excellent short-term stability and calibration accuracy. Excluding a few noisy detectors, either identified prelaunch or occurring postlaunch, on-orbit changes in TEB responses have been less than 0.5% on an annual basis. By comparison; the overall Aqua TEB performance has been better than that of Terra MODIS,

Xiong, Xiaoxiong↗

Event sequence detector

An event sequence detector is described with input units, each associated with a row of bistable elements arranged in an array of rows and columns. The detector also includes a shift register which is responsive to clock pulses from any of the units to sequentially provide signals on its output lines each of which is connected to the bistable elements in a corresponding column. When the event-indicating signal is received by an input unit it provides a clock pulse to the shift register to provide the signal on one of its output lines. The input unit also enables all its bistable elements so that the particular element in the column supplied with the signal from the register is driven to an event-indicating state.

Hanna, M. F.↗

Performance analysis of a filtered wide field-of-view radiometer for earth radiation budget measurements

The proposed Earth Radiation Budget Satellite System (ERBSS) of the 1980's will include a wide field-of-view (WFOV) fixed axes earth radiator discriminator consisting of a shortwave channel and a total (unfiltered) channel. The broadband spectral isolation required for the shortwave channel is achieved by use of a hemispherical fused silica (Suprasil W) dome filter placed in front of a wire wound thermopile radiation detector. A description is presented of the thermal response of the single-fused silica dome filter in the ERBSS WFOV shortwave channel conceptual design and the impact of that response on the channel measurement. Results from design definition and performance analysis studies are included. Problems associated with achieving the desired levels of confidence in a high accuracy filtered, WFOV radiometer are discussed. Design approaches, ground calibration, and data reduction techniques which minimize measurement uncertainties are explained.

Cooper, J. E.↗

The new MSFC Solar vector magnetograph. Center director's discretionary fund

The unique MSFC solar vector magnetograph allows measurements of all three components of the Sun's photospheric magnetic field over a wide field-of-view with spatial resolution determined by a 2.7 x 2.7 arc second pixel size. This system underwent extensive modifications to improve its sensitivity and temporal response. The modifications included replacing an SEC vidicon detector with a solid-state CCD camera; replacing the original digital logic circuitry with an electronic controller and a computer to provide complete, programmable control over the entire operation of the magnetograph; and installing a new polarimeter which consists of a single electro-optical modulator coupled with interchangeable waveplates mounted on a rotating assembly. The system is described and results of calibrations and tests are presented. Initial observations of solar magnetic fields with the new magnetograph are presented.

Hagyard, M. J.↗

Integrating amplifiers using cooled JFETs

It is shown how a simple integrating amplifier based on commercially available JFET and MOSFET switches can be used to measure photocurrents from detectors with noise levels as low as 1.6 x 10 to the -18th A/root Hz (10 electrons/sec). A figure shows the basic circuit, along with the waveform at the output. The readout is completely nondestructive; the reset noise does not contribute since sampling of the accumulated charge occurs between resets which are required only when the stored charge has reached a very high level. The storage capacity ranges from 10 to the 6th to 10 to the 9th electrons, depending on detector parameters and linearity requirements. Data taken with an Si:Sb detector operated at 24 microns are presented. The responsivity agrees well with the value obtained by Young et al. (1981) in the transimpedance amplifier circuit. The data are seen as indicating that extremely low values of NEP can be obtained for integration times of 1 sec and that longer integrations continue to improve the SNR at a rate faster than the square root of time when background noise is not present.

Low, F. J.↗

Near contact phenomena and transient effects in far infrared photoconductors

A combination of experimental and modeling work is summarized in two areas: first, the calculation of excess free carrier and space charge distributions near contacts and their effects on device resistivity, and second, the characterization of a slow transient response (tau approx. 1 sec) in Ge:Be detectors which is due to trapping associated with Be(+) formation. In both cases, analytical models, based on continuity and rate equations, have been developed to enable the application of these findings to a wide variety of photoconductor materials.

Haegel, Nancy M.↗

Global Lightning Variations Caused by Changes in Flash Rate and by Changes in Number of Thunderstorms

Observations from the Optical Transient Detector in space are used to examine the response of the number of storms and the total flash rate to thermodynamic forcing of deep convection on the diurnal and annual time scales. On the diurnal time scale, the flash rate appears to track with cloud buoyancy, and storm numbers dominate later in the cycle. On the annual time scale, almost all of the total lightning response is due to changes in the number of storms, with a negligible contribution from flash rate.

Williams, E.↗

Temperature Evolution of Excitonic Absorptions in Cd(1-x)Zn(x)Te Materials

The studies consist of measuring the frequency dependent transmittance (T) and reflectance (R) above and below the optical band-gap in the UV/Visible and infrared frequency ranges for Cd(l-x),Zn(x),Te materials for x=0 and x=0.04. Measurements were also done in the temperature range from 5 to 300 K. The results show that the optical gap near 1.49 eV at 300 K increases to 1.62 eV at 5 K. Finally, we observe sharp absorption peaks near this gap energy at low temperatures. The close proximity of these peaks to the optical transition threshold suggests that they originate from the creation of bound electron-hole pairs or excitons. The decay of these excitonic absorptions may contribute to a photoluminescence and transient background response of these back-illuminated HgCdTe CCD detectors.

Quijada, Manuel A.↗

Development of Biomorphic Flyers

Biomorphic flyers have recently been demonstrated that utilize the approach described earlier in "Bio-Inspired Engineering of Exploration Systems" (NPO-21142), NASA Tech Briefs, Vol. 27, No. 5 (May 2003), page 54, to distill the principles found in successful, nature-tested mechanisms of flight control. Two types of flyers are being built, corresponding to the imaging and shepherding flyers for a biomorphic mission described earlier in "Cooperative Lander- Surface/Aerial Microflyer Missions for Mars Exploration" (NPO-30286), NASA Tech Briefs, Vol. 28, No. 5 (May 2004), page 36. The common features of these two types of flyers are that both are delta-wing airplanes incorporating bio-inspired capabilities of control, navigation, and visual search for exploration. The delta-wing design is robust to approx.40 G axial load and offers ease of stowing and packaging. The prototype that we have built recently is shown in the figure. Such levels of miniaturization and autonomous navigation are essential to enable biomorphic microflyers (<1 kg) that can be deployed in large numbers for distributed measurements and exploration of difficult terrain while avoiding hazards. Individual bio-inspired sensors that will be incorporated in a biomorphic flyer have been demonstrated recently. These sensors include a robust, lightweight (~6 g), and low-power (~40 mW) horizon sensor for flight stabilization. It integrates successfully the principles of the dragonfly ocelli. The ocelli are small eyes on the dorsal and forward regions of the heads of many insects. The ocelli are distinct from the compound eyes that are most commonly associated with insect vision. In many insects, the ocelli are little more than single-point detectors of short-wavelength light and behavioral responses to ocelli stimuli are hard to observe. The notable exception is found in dragonflies, where flight control is notably degraded by any interference with the ocellar system. Our team has discovered recently that the ocelli are a dedicated horizon sensor, with substantial optical processing and multiple spectral sensitivity. To our knowledge, this is the world s first demonstrated use of a "biomorphic ocellus" as a flight-stabilization system. The advantage of the ocelli over a similarly sized system of rate gyroscopes is that both attitude control and rate damping can be realized in one device. A full inertial unit and significant processing would otherwise be required to achieve the same effect. As a prelude to full autonomy, substantial stability augmentation is provided to the pilot at very low cost in terms of space, power, and mass. The sensor is about 40 times lighter than a comparable inertial attitude reference system. Other significant features of the biomorphic flyer shown in the figure include its ability to fly at high angles of attack ~30 and a deep wing chord which allows scaling to small size and low Reynold s number situations. Furthermore, the placement of the propulsion system near the center of gravity allows continued control authority at low speeds. These attributes make such biomorphic flyers uniquely suited to planetary and terrestrial exploration where small size and autonomous airborne operation are required.

Thakoor, Sarita↗

Techniques for Targeted Fermi-GBM Follow-Up of Gravitational-Wave Events

The Advanced LIGO and Advanced Virgo ground-based gravitational-wave (GW) detectors are projected to come online 2015 2016, reaching a final sensitivity sufficient to observe dozens of binary neutron star mergers per year by 2018. We present a fully-automated, targeted search strategy for prompt gamma-ray counterparts in offline Fermi-GBM data. The multi-detector method makes use of a detailed model response of the instrument, and benefits from time and sky location information derived from the gravitational-wave signal.

Blackburn, L.↗

A novel electron tunneling infrared detector

The pneumatic infrared detector, originally developed by Golay in the late 1940s, uses the thermal expansion of one cm(exp 3) of xenon at room temperature to detect the heat deposited by infrared radiation. This detector was limited by thermal fluctuations within a 10 Hz bandwidth, but suffered from long thermal time constants and a fragile structure. Nevertheless, it represents the most sensitive room temperature detector currently available in the long wavelength infrared (LWIR). Fabrication of this type of detector on smaller scales has been limited by the lack of a suitably sensitive transducer. Researchers designed a detector based on this principle, but which is constructed entirely from micromachined silicon, and uses a vacuum tunneling transducer to detect the expansion of the trapped gas. Because this detector is fabricated using micromachining techniques, miniaturization and integration into one and two-dimensional arrays is feasible. The extreme sensitivity of vacuum tunneling to changes in electrode separation will allow a prototype of this detector to operate in the limit of thermal fluctuations over a 10 kHz bandwidth. A calculation of the predicted response and noise of the prototype is presented with the general formalism of thermal detectors. At present, most of the components of the prototype have been fabricated and tested independently. In particular, a characterization of the micromachined electron tunneling transducer has been carried out. The measured noise in the tunnel current is within a decade of the limit imposed by shot noise, and well below the requirements for the operation of an infrared detector with the predicted sensitivity. Assembly and characterization of the prototype infrared detector will be carried out promptly.

Kenny, T. W.↗

Deployable pressurized cell structure for a micrometeoroid detector

This disclosure comprises a plurality of individual pressurized cells which are caused to leak in response to a micrometeoroid penetration, the leak being sensed by appropriate instrumentation. The plurality of cells may be rolled into a compact arrangement such that the volume of the micrometeoroid detector is small and therefore readily packed in a payload of a launch vehicle. Once the payload is placed in orbit, the rolled up cells can be released, pressurized and provide a relatively rigid, large surface area for detecting micrometeoroid penetration.

Kinard, W. H.↗

Characterization of an advanced focal plane for multispectral linear array (MLA) application

It is pointed out that the MLA instrument represents the next generation in the Landsat series of earth resources satellites. The MLA sensor concept utilizes a pushbroom scan mode to eliminate electromechanical scan mirrors, and the lower reliabililty and higher power dissipation which accompany their employment. The pushbroom scanner makes use of a linear array which consists generally of thousands of detectors oriented perpendicular to the along-track direction of the satellite. Test techniques have been developed for the measurement of the module parameters which are critical to MLA focal plane performance. These measurements include the determination of infrared responsivity, linearity over the dynamic range, temporal noise, and fixed pattern effects on each detector element of each module tested. Tests related to spectral response, crosstalk, and spot scan profiles are also conducted. A description is provided of the test equipment involved.

King, P.↗