Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data logging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Second ARM Aerosol Chemical Speciation Monitor Users’ Meeting Report

The aerosol chemical speciation monitor (ACSM) was developed to adapt the technology of the aerosol mass spectrometer (AMS) to routine, long-term, standalone monitoring. The calculation of particulate mass concentration from ACSM data requires the measurement of the response of the instrument to aerosol of specific size and composition as well as assumptions about the instrument response based on laboratory measurements and field experience acquired over more than two decades of operation of AMS and a decade of operation of the ACSM. Three parameters in the concentration calculations that are particularly important are the NO3 response factor (RFNO3), relative ionization efficiency (RIE), and the collection efficiency (CE). The values of RFNO3 and RIEs are determined from calibration, however the jump calibration method previously used in calibration can result in errors in the RIE for sulfate. This has been corrected by implementing a continuous calibration method. The default collection efficiency is 0.5. This has been shown to result in mass loadings that do not agree with mass determinations from other instruments because of effects of composition on the vaporization of the particles. The previous work of investigators addressing this issue is discussed. After preliminary work on ACSM and scanning mobility particle sizer (SMPS) data from the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility Southern Great Plains (SGP) observatory collected in late 2016 and 2017 produced a parameterization of composition dependent collection efficiency very different from the results of previous studies, SMPS data were examined and we determined that there was significant mass that the instrument did not capture because the particles with diameters larger than 465 nm are not counted by this instrument. Data for the ultra-high-sensitivity aerosol spectrometer (UHSAS), SMPS, and ACSM are available for nearly all of 2019. The data from UHSAS and SMPS collected in 2019 were compared. We found that the UHSAS data has particle counts and total volumes significantly less than measured by the condensation particle counter (CPC) and SMPS. The SMPS data were extended by fitting the average volume distribution with a log normal curve and using this relationship to estimate a mass value for the SMPS over extended diameter range. The extended SMPS mass values result in a CDCE parameterization that is in better agreement with the results of other investigators, but is still different from other formulations. The working group recommends that the ACSM data be processed with a collective efficiency (CE)=1, that this be documented clearly in the metadata, and the use of the default CE of 0.5 or a formulation of composition-dependent collection efficiencies (CDCE) chosen by the user should be implemented based on the ammonium nitrate mass fraction. This is clearly necessary for the wintertime SGP ACSM data because of the high nitrate concentrations.

47 OTHER INSTRUMENTATION↗

Observations and Modeling of Fiber-Optics Strain on Hydraulic Fracture Height Growth in HFTS-2

Understanding fracture height growth can be of great significance to optimizing field development and improving recovery. The Hydraulic Fracturing Test Site 2 (HFTS-2) has provided a unique opportunity and an advanced dataset to allow us to observe and understand fracture geometries rigorously. Low frequency distributed acoustic sensing (LF-DAS) data from a vertical well in HFTS-2 showed three key observations: (i) excessive upward height growth (>1000 ft) and limited downward growth of the hydraulic fractures during pumping, (ii) considerable additional upward fracture height growth (~300 ft) after well shut in, and (iii) very complex LF-DAS strain rate patterns for a small fiber-to-stage offset. Advanced geomechanical modeling was performed to simulate the hydraulic fracture propagation and the resulting strain responses in the vertical direction. The modeling results demonstrated asymmetric upward and downward fracture height growths as observed in HFTS-2 with a similar upward height growth rate. Simulated waterfall plots of vertical strain rate showed distinct patterns for different fiber-to-fracture distances. The upward-growing fracture tip can be clearly identified by the interfaces between compressing and extending zones. It was also found that the complex strain rate patterns observed in HFTS-2 for small fiber-stage offsets were not caused by the mechanical layering but possibly result from the simultaneous propagation of multiple hydraulic fractures at different rates. Furthermore, the simulation results improved the understating of the HFTS-2 LF-DAS data and the simulated strain rate patterns could also serve as templates for fracture height interpretation from LF-DAS data in future.

58 GEOSCIENCES↗

Radiation Observations with Satellite 1958 Alpha Explorer I

On 1 February 1958 at 0348 U.T. earth satellite 1958 Alpha (Explorer I) was launched from Cape Canaveral. This satellite contained a Geiger Muller tube for the measurement of the flux of energetic charged particles, and detectors for determining the micrometeorite flux and satellite temperature (see Figure 1), The high power transmitter and its associated instrumentation operated until partial exhaustion of the transmitter batteries on 12 February 1958. The transmitter reappeared briefly on 24 February, The low power system operated properly until about 0700 U,T, on 16 March, at which time the batteries powering the G.M. tube circuits became exhausted. During the operating time a large amount of data was recorded by a network of seventeen receiving stations. A sampling of early recordings was reduced and analyzed as they arrived from the receiving stations. These data, in conjunction with data from the first few orbits of 1958 Gamma (Explorer III), resulted in the announcement on 1 May 1958 of the region of high intensity radiation surrounding the earth (Van Allen, 1958), The detailed, complete reduction of the 1958 Alpha data has now been completed, This paper is a tabulation of all the data received from this satellite. It consists primarily of two parts. The first part is the master recording log on which are listed all recordings of the satellite signals obtained by the receiving station network. The actual data tabulation is contained in part two.

RADIATION↗

SECARB-USA: Needs Assessment Framework for Storage Complexes (Task 2.1.b)

A team of SECARB storage experts examined 63 formations at 39 sites that were selected to represent the range of diversity of newly assessed, as well as well-advanced, storage prospects in the SECARB region. We inventoried the data needs triggered by the requirements to obtain a Class VI UIC storage permit, the data needs that results from the requirement to create geocellular fluid flow models to support that permit, and by pragmatic and best practice inputs such as public acceptance, regulatory readiness, and pore space leasing. We anchored both the needs inventory and the processes for and cost of meeting the needs with data from 9 sites in in the SECARB area that have advanced far in characterization. Results show that the total cost of characterization prior to obtaining a permit is convergent, because the permit and modeling requirements drive projects to obtain the same types of data for all cases. The high cost data that control cost are 1) drilling, coring, core-testing, logging, sampling and testing a characterization well and 2) collection of a 3-D seismic survey to map reservoir and confining system properties over the area of the plume or the area of elevated pressure. In 5 of our case study sites we determined that one or both of these costs could be avoided because the needs are met by available data.

54 ENVIRONMENTAL SCIENCES↗

Growth, mortality, wood density, biomass data from BIONTE inventories in Manaus, Brazil

BIONTE (BIOmass and NuTrient Experiment) is a selective logging experiment established at the Experimental Station of Tropical Forestry (EEST, aka “ZF2”) field research station in the mid 1980s in the central Amazon (Higuchi et al. 1997, Amaral et al. 2019). Led by the National Institute for Amazon Research (INPA) in Brazil, the project aimed at assessing the effects of logging intensity on forest dynamics and enabling the creation of a model of forest management for the Central Amazon. The experiment included three levels of increasing selective logging intensity and controls, with 1 hectare sample plots (12 total) located at the center of 4 hectare treatment plots. The site’s Köppen classification is tropical rainforest (Af), characterized by high temperatures and humidity, with mean annual temperatures around 27 ℃ and mean annual precipitation around 2200 mm of rain. The vegetation has a high floristic diversity, the soils of the region are poor in nutrients, and the topography is characterized by plateaus (where BIONTE is located), and also valley bottoms and slopes. The inventory (growth and mortality) and biomass data included here covers the 1990 to 2019 period, with wood density being averaged from existing datasets. This dataset includes a data file in .csv file format and a .txt file, BIONTE_mortality-rates_headers.txt, that provides descriptions for the data file headers.

54 ENVIRONMENTAL SCIENCES↗

Analysis of ocean color scanner data from the Superflux III Experiment

The scanner collected data on October 15, 20, and 22, 1980. Single-channel gray-scale data products generated 5 minutes after the scanner were collected and showed details of the Chesapeake plume structure, suggesting that this quick-look capability could have potential use for experiments in real time. The Chesapeake Bay plume extended offshore about 5 nautical miles on October 15, and 7 nautical miles on October 20. Using the October 15 1980, data, a correlation coefficient of r = 0.889 was obtained between chlorophyll 'A' and the ratio of band 7 (664-684 nanometers) to band 9 (746-766 nanometers). This ratio was then used to calculate the average surface chlorophyll 'A' concentration of the water flowing out of the Chesapeak Bay. A ratio from the Ocean Color Scanner bands was created to simulate the ratio that the Multichannel Ocean Color Sensor uses to calculate chlorophyll A concentrations. Using the October 15, 1980, data set, this ratio has a correlation coefficient of r = -0.739 with the log of the chlorophyll 'A' and the ratio of band 2 minus band 4 to band 2 plus band 4 of the Ocean Color Scanner. No correlation is found between the Ocean Color Scanner data and total suspended solid measurements made on October 15, 1980.

Ohlhorst, C. W.↗

EGS Collab Experiment 2: Continuous Active Source Seismic Monitoring (CASSM)

The dataset contains continuous active-source seismic monitoring (CASSM) data collected during EGS Collab Experiment 2, conducted from February to September 2022 at the Sanford Underground Research Facility in Lead, South Dakota. This experiment aimed to investigate enhanced geothermal systems through high-pressure fluid injections at depths of 1200-1500 meters. The seismic monitoring system included 16 three-component piezoelectric accelerometers and 24 hydrophones installed in boreholes around the injection zones, recording signals from piezoelectric seismic sources. Data were acquired using both continuous and triggered recording systems, with sampling rates of up to 100 kHz. The raw data are organized by timestamps and stored in .dat format, with accompanying log files. Calibration certificates for selected accelerometers are provided to aid in correcting sensor responses, though users are advised to consider possible effects of enclosures and installation on sensor performance. Users are strongly advised to consult the accompanying report, which outlines the experimental setup, data acquisition, sensor specifications, and recording systems.

15 GEOTHERMAL ENERGY↗

Characterization of Pinhole Collimators for High-Resolution Gamma Imaging of Irradiated Fuel

Post-irradiation examination (PIE) of nuclear fuels requires imaging tools capable of resolving isotopic and spatial features with high throughput. This project contributes to a proof-of-concept effort aimed at advancing gamma emission tomography (GET) by evaluating novel fine-aperture pinhole collimators. Two Rose’s metal collimators, 100 µm (20° acceptance angle) and 350 µm (30° acceptance angle), were prototyped and characterized for their effectiveness in transporting gamma rays through the pinhole aperture. To support data collection, a Python-based data acquisition system was developed to coordinate a rotation stage, linear stage, and CZT detector, reducing latency in high-rate gamma event logging to one second per acquisition. Queue-based file writing enabled seamless real-time data capture for count rates up to 35,000 counts per second (cps). List-mode parsing algorithms were implemented to differentiate single and simultaneous gamma interactions for future tomographic reconstruction. Detector response was evaluated in both spectroscopy and list mode acquisition methods across varying source distances to confirm absolute and collimator efficiencies. Preliminary efficiency figures suggest effective collimation of gamma-rays with energies below 700 keV, with ~4% residual intensity through the aperture for Cs-137. The impact of collimator geometry on image quality is currently being evaluated. This groundwork supports the ongoing development of a sub mm resolution cone-beam CT system for imaging fuel phantoms, an essential step toward improving GET efficiency and accelerating nuclear fuel qualification efforts.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

MSL Telecom Automated Anomaly Detection

The Mars Science Laboratory (MSL) Telecom Operations Team at the Jet Propulsion Laboratory (JPL) has implemented a machine learning system in order to automate the anomaly detection process as a part of daily operations. Machine learning enables reliable detection of anomalies in Telecom-related telemetry and automated reporting of Telecom subsystem status, resulting in an 90% reduction in team workload and improved anomaly detection reliability. At present, machine learning methods are used to detect: 1. Anomalous long-term trends in telemetry data 2. Anomalous time-domain evolution of telemetry values Both types of anomalies pose their own unique challenges that are addressed in different ways. In the first case, long term trending of daily minima, maximum, and mean telemetry values in temperatures, currents, voltages, and radio frequency (RF) power levels is used in addition to hard threshold safety checks to look for changes in long-term equipment health and performance. Long-term trending methods allow for ordinary seasonal variations in these quantities caused by temperature changes over the course of the Martian year while allowing operators to determine whether current performance remains in line with historical values from previous years. Changes in long-term trends can provide important insights into the health and status of the rover's on-board systems as well as valuable early warning if subtle degradation begins to take hold. But while trending of daily statistics is valuable, it does not detect anomalies in the short-term time evolution of data over the course of minutes or hours during a day, and this task is handled with short-term shape analysis. Principal components analysis (PCA) has been found to provide robust detection of short-term anomalies, and several examples of the use of PCA to detect actual anomalous events will be provided here. In using PCA, we use both the percentage of explained variance and also a log likelihood test on the PCA expansion coefficients to flag telemetry data for human review. Previous work in the field of spacecraft anomaly detection includes [1] for MSL and [2] for some other JPL missions.

Mukai, Ryan↗

Assessment of variations in thermal cycle life data of thermal barrier coated rods

The reported study had the purpose to examine variations in cyclic life and in adhesive/cohesive coating strength. Possible effects of heating rate, stress reversal, temperature level, and ceramic deposition methods on coating life were also investigated. Life cycle data for 22 thermal barrier coated rods were examined and found to be statistically modeled by normal or log-normal distributions. The sample mean was 1330 cycles with a standard deviation of 520 cycles. Adhesive/cohesive pulloff strength data for 20 thermal barrier coated flat head piston specimens were taken. The average pulloff stress was 9 MPa with a standard deviation of 4.2 MPa. It was found that variations in heating rate can produce significant variations in the life cycle data.

Hendricks, R. C.↗

A semi–automatic analytical methodology for characterizing the energy consumption of MRI systems using load duration curves

Background and purpose: Magnetic resonance imaging (MRI) scanners are a major contributor to greenhouse gas emissions from the healthcare sector, and efforts to improve energy efficiency and reduce energy consumption rely on quantification of the characteristics of energy consumption. The purpose of this work was to develop a semi-automatic analytical methodology for the characterization of the energy consumption of MRI systems using only the load duration curve (LDC). LDCs are a fundamental tool used across various fields to analyze and understand the behavior of loads over time. Methods: An electric current transformer sensor and data logger were installed on two 3T MRI scanners from two vendors, termed M1 (outpatient scanner) and M2 (inpatient/emergency scanner). Data was collected for 1 month (7/11/2023 to 8/11/2023). Active power was calculated, assuming a balanced three-phase system, using the average current measured across all three phases, a 480 V reference voltage for both machines, and vendor-provided power factors. An LDC was constructed for each system by sorting the active power values in descending order and computing the cumulative time (in units of percentage) for each data point. The first derivative of the LDC was then computed (LDC’), smoothed by convolution with a window function (sLDC’), and used to detect transitions between different system modes including (in descending power levels): scan, prepared-to-scan, idle, low-power, and off. The final, segmented LDC was used to measure time (% total time), total energy (kWh), and mean power (kW) for each system mode on both scanners. The method was validated by comparing mean power values, computed using the segmented 1-month LDC, for each nonproductive system mode (i.e., prepared-to-scan, idle, lower-power, and off) against power levels measured after a deliberate system shutdown was performed for each scanner (1 day worth of data). Results: The validation revealed differences in mean power values <1.4% for all nonproductive modes and both scanners. In the scan system mode, the mean power values ranged from 29.8 to 37.2 kW and the total energy consumed for 1 month ranged from 11 106 to 14 466 kWh depending on the scanner. Over the course of 1 month, the portion of time the scanners were in nonproductive modes ranged from 76% to 80% across scanners and the nonproductive energy consumption ranged from 8010 to 6722 kWh depending on the scanner. The M1 (outpatient) scanner consumed 99.9 and 183.9 kWh/day in idle mode for weekdays and weekends, respectively, because the scanner spent 23% more time proportionally in idle mode on the weekends. Conclusions: A semi-automatic method for quantifying energy consumption characteristics of MRI scanners was introduced and validated. This method is relatively simple to implement as it requires only power data from the scanners and avoids the technical challenges associated with extracting and processing scanner log files. Finally, the methodology enables quantitative evaluation of the power, time, and energy characteristics of MRI scanners in scan and nonproductive system modes, providing baseline data and the capability of identifying potential opportunities for enhancing the energy efficiency of MRI scanners.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fluctuations in Conjunction Miss Distance Projections as Time Approaches Time of Closest Approach

A responsibility of the Trajectory Operations Officer is to ensure that the International Space Station (ISS) avoids colliding with debris. United States Space Command (USSPACECOM) tracks and catalogs a portion of the debris in Earth orbit, but only objects with a perigee less than 600 km and a radar cross section (RCS) greater than 10 cm-objects that, in fact, represent only a small fraction of the objects in Earth orbit. To accommodate for this, the ISS uses shielding to protect against collisions with smaller objects. This study provides a better understanding of how quickly, and to what degree, USSPACECOM projections tend to converge to the final, true miss distance. The information included is formulated to better predict the behavior of miss distance data during real-time operations. It was determined that the driving components, in order of impact on miss distance fluctuations, are energy dissipation rate (EDR), RCS, and inclination. Data used in this analysis, calculations made, and conclusions drawn are stored in Microsoft Excel log sheets. A separate log sheet, created for each conjunction, contains information such as predicted miss distances, apogee and perigee of debris orbit, EDR, RCS, inclination, tracks and observations, statistical data, and other evaluation/orbital parameters.

Christian, John A., III↗

Log-N/Period Sensitivity Analysis

The Log-N/Period system utilizes a compensated ion chamber to measure neutron radiation in the reactor core. This analysis focuses on determining a more accurate value for the sensitivity of the installed compensated ion chambers for the Log-N/Period system at the ATR. Using calibration procedures a formula for indirectly calculating the sensitivity of the chambers was derived. Using historical data from approximately ten reactor cycles a new average sensitivity for both channels of the Log-N/Period system was determined.

42 ENGINEERING↗

2000 The Twin Cities Metropolitan Area Travel Behavior Inventory

The 2000 Twin Cities Metropolitan Area Travel Behavior Inventory, conducted by Twin Cities Metropolitan Council—Saint Paul, was the first major travel survey in the region since 1990. The 2000 inventory includes a home interview survey, an establishment survey, a transit survey, external station traffic counts, and an external station origin/destination survey. The study area under the household inventory survey included the seven counties of the regional Metropolitan Planning Organization and thirteen adjacent counties. Demographic, socioeconomic, and travel data were gathered for 6,386 households. Of these, 6,219 households completed the travel logs, which includes household members older than five years old.

1Hz data↗

Hypergolic oxidizer and fuel scrubber emissions

Hypergolic fuels and oxidizer are emitted to the environment during fueling and deservicing shuttle and other spacecraft. Such emissions are difficult to measure due to the intermittent purge flow and to the presence of suspended scrubber liquor. A new method for emissions monitoring was introduced in a previous paper. This paper is a summary of the results of a one-year study of shuttle launch pads and orbiter processing facilities (OPF's) which proved that emissions can be determined from field scrubbers without direct measurement of vent flow rate and hypergol concentration. This new approach is based on the scrubber efficiency, which was measured during normal operations, and on the accumulated weight of hypergol captured in the scrubber liquor, which is part of the routine monitoring data of scrubber liquors. To validate this concept, three qualification tests were performed, logs were prepared for each of 16 hypergol scrubbers at KSC, the efficiencies of KSC scrubbers were measured during normal operations, and an estimate of the annual emissions was made based on the efficiencies and the propellant buildup data. The results have confirmed that the emissions from the KSC scrubbers can be monitored by measuring the buildup of hypergol propellant in the liquor, and then using the appropriate efficiency to calculate the emissions. There was good agreement between the calculated emissions based on outlet concentration and flow rate, and the emissions calculated from the propellant buildup and efficiency. The efficiencies of 12 KSC scrubbers, measured under actual servicing operations and special test conditions, were assumed to be valid for all subsequent operations until a significant change in hardware occurred. An estimate of the total emissions from 16 scrubbers for three years showed that 0.3 kg/yr of fuel and 234 kg/yr of oxidizer were emitted.

Parrish, Clyde F.↗

Hemodynamic Responses to Head and Neck Cooling

Personal thermoregulatory systems which provide head and neck cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objective of this study was to measure the scalp temperature and circulatory responses during use of one commercially available thermal control system. The Life Support Systems, Inc. Mark VII portable cooling system and a liquid cooling helmet were used in this study. Two EEG electrodes and one skin temperature transducer were placed on the anterior midline of the scalp to measure the scalp blood and temperature. Blood flow was measured using a bipolar impedance rheograph. Ten subjects, seated in an upright position at normal room temperature, were tested at high, medium, moderate, moderate-low and low coolant temperatures. Scalp blood flow was recorded continuously using a computer data acquisition system with a sampling frequency of 200 Hz. Scalp temperature and cooling helmet Inlet temperature was logged periodically during the test period. This study quantifies the effect of head cooling upon scalp temperature and blood flow. These data may also be used to select operational specifications of the head cooling system for biomedical applications such as the treatment of migraine headaches, scalp cooling during chemotherapy, and cooling of multiple sclerosis patients.

Ku, Yu-Tsuan E.↗

Computing Bottleneck Structures at Scale for High-Precision Network Performance Analysis

The Theory of Bottleneck Structures is a recently-developed framework for studying the performance of data networks. It describes how local perturbations in one part of the network propagate and interact with others. This framework is a powerful analytical tool that allows network operators to make accurate predictions about network behavior and thereby optimize performance. Previous work implemented a software package for bottleneck structure analysis, but applied it only to toy examples. In this work, we introduce the first software package capable of scaling bottleneck structure analysis to production-size networks. Here, we benchmark our system using logs from ESnet, the Department of Energy's high-performance data network that connects research institutions in the U.S. Using the previously published tool as a baseline, we demonstrate that our system achieves vastly improved performance, constructing the bottleneck structure graphs in 0.21 s and calculating link derivatives in 0.09 s on average. We also study the asymptotic complexity of our core algorithms, demonstrating good scaling properties and strong agreement with theoretical bounds. These results indicate that our new software package can maintain its fast performance when applied to even larger networks. They also show that our software is efficient enough to analyze rapidly changing networks in real time. Overall, we demonstrate the feasibility of applying bottleneck structure analysis to solve practical problems in large, real-world data networks.

benchmark↗

Millimeter-Wave Radar Field Measurements and Inversion of Cloud Parameters for the 1999 Mt. Washington Icing Sensors Project

The Mount Washington Icing Sensors Project (MWISP) was a multi-investigator experiment with participants from Quadrant Engineering, NOAA Environmental Technology Laboratory (NOAA/ETL), the Microwave Remote Sensing Laboratory (MIRSL) of the University of Massachusetts (UMass), and others. Radar systems from UMass and NOAA/ETL were used to measure X-, Ka-, and W-band backscatter data from the base of Mt. Washington, while simultaneous in-situ particle measurements were made from aircraft and from the observatory at the summit. This report presents range and time profiles of liquid water content and particle size parameters derived from range profiles of radar reflectivity as measured at X-, Ka-, and W-band (9.3, 33.1, and 94.9 GHz) using an artificial neural network inversion algorithm. In this report, we provide a brief description of the experiment configuration, radar systems, and a review of the artificial neural network used to extract cloud parameters from the radar data. Time histories of liquid water content (LWC), mean volume diameter (MVD) and mean Z diameter (MZD) are plotted at 300 m range intervals for slant ranges between 1.1 and 4 km. Appendix A provides details on the extraction of radar reflectivity from measured radar power, and Appendix B provides summary logs of the weather conditions for each day in which we processed data.

Pazmany, Andrew L.↗