Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cracking temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

High Temperature Materials for Chemical Propulsion Applications

Radiation or passively cooled thrust chambers are used for a variety of chemical propulsion functions including apogee insertion, reaction control for launch vehicles, and primary propulsion for planetary spacecraft. The performance of these thrust chambers is limited by the operating temperature of available materials. Improved oxidation resistance and increased operating temperatures can be achieved with the use of thermal barrier coatings such as zirconium oxide (ZrO2) and hafnium oxide (HfO2). However, previous attempts to include these materials showed cracking and spalling of the oxide layer due to poor bonding. Current research at NASA's Marshall Space Flight Center (MSFC) has generated unique, high temperature material options for in-space thruster designs that are capable of up to 2500 C operating temperatures. The research is focused on fabrication technologies to form low cost Iridium,qF_.henium (Ir/Re) components with a ceramic hot wall created as an integral, functionally graded material (FGM). The goal of this effort is to further de?celop proven technologies for embedding a protective ceramic coating within the Ir/Re liner to form a robust functional gradient material. Current work includes the fabrication and testing of subscale samples to evaluate tensile, creep, thermal cyclic/oxidation, and thermophysical material properties. Larger test articles have also being fabricated and hot-fire tested to demonstrate the materials in prototype thrusters at 1O0 lbf thrust levels.

Elam, Sandra↗

Matrix Cracking in 3D Orthogonal Melt-Infiltrated SiC/SiC Composites with Various Z-Fiber Types

The occurrence of matrix cracks in melt-infiltrated SiC/SiC composites with a 3D orthogonal architecture was determined at room temperature for specimens tested in tension oriented in the X-direction (parallel to Z-bundle weave direction) and Y-direction (perpendicular to Z-bundle weave direction) and Y-direction (perpendicular to Z-bundle weave direction). The fiber-types were Sylramic and Sylramic-IBN in the X and Y-directions and lower modulus ZMI, T300, and rayon in the Z-direction. Acoustic emission (AE) was used to monitor the matrix cracking activity. For Y-direction composites, the AE data was used to determine the exact (+/- 0.25 mm) location where matrix cracks occurred in the 3D orthogonal architecture. This enabled the determination of the stress-dependent matrix crack distributions for small but repeatable matrix rich 'unidirectional' and the matrix poor 'cross-ply' regions within the architecture. It was found that matrix cracking initiated at very low stresses (approx. 40 MPa) in the 'unidirectional' regions for the largest z-direction fiber tow composites. Decreasing the size of the z-fiber bundle, increased the stress for matrix cracking in the 'unidirectional' regions. Matrix cracking in the 'cross-ply' regions always occurred at higher stresses than in 'unidirectional' regions, and the stress-dependent matrix crack distribution of the 'cross-ply' regions was always over a wider stress-range than the 'unidirectional' regions. For composites tested in the X-direction, a lower elastic modulus and a narrower and lower stress-range for matrix cracking were observed compared to composites tested in the Y-direction.

Morscher, Gregory N.↗

Effects of thermal cycling on residual mechanical properties of C6000/PMR-15 graphite polyimide

An experimental study to determine the effects of thermal cycling on residual mechanical properties of a graphite/polyimide composite has been conducted. Interlaminar shear, flexure and compression strengths were measured at room temperature and 316 C on unidirectional and quasi-isotropic laminates subjected to 150 and 500 thermal cycles between -156 C and 316 C. Thermal cycling produced transverse microcracks and delaminations in the laminates. The linear density of the microcracks (35/cm) was about the same after 150 and 500 cycles. Although the crack density did not change from 150 to 500 cycles, crack growth did occur with intralamina cracks growing into adjacent lamina. The matrix controlled properties of the quasi-isotropic laminate at both room temperature and 316 C were significantly reduced by thermal cycling. However, the properties of the unidirectional laminate were significantly reduced only at 316 C.

Tompkins, S. S.↗

Patterns of residual stresses due to welding

Residual stresses caused by welding result from the nonuniform rate of cooling and the restrained thermal contraction or non-uniform plastic deformation. From the zone of extremely high temperature at the weld, heat flows into both the adjoining cool body and the surrounding atmosphere. The weld metal solidifies under very rapid cooling. The plasticity of the hot metal allows adjustment initially, but as the structure cools the rigidity of the surrounding cold metal inhibits further contraction. The zone is compressed and the weld is put under tensile stresses of high magnitude. The danger of cracking in these structural elements is great. Change in specific volume is caused by the change in temperature.

Botros, B. M.↗

10 000-hr Cyclic Oxidation Behavior of 68 High-Temperature Co-, Fe-, and Ni- Base Alloys Evaluated at 982 deg. C (1800 deg. F)

Power systems with operating temperatures in the range of 815 to 982 C (1500 to 1800 F) frequently require alloys that can operate for long times at these temperatures. A critical requirement is that these alloys have adequate oxidation resistance. The alloys used in these power systems require thousands of hours of operating life with intermittent shutdown to room temperature. Intermittent power plant shutdowns, however, offer the possibility that the protective scale will tend to spall (i.e., crack and flake off) upon cooling, increasing the rate of oxidative attack in subsequent heating cycles. Thus, it is critical that candidate alloys be evaluated for cyclic oxidation behavior. It was determined that exposing test alloys to ten 1000-hr cycles in static air at 982 10 000-hr Cyclic Oxidation Behavior of 68 High-Temperature Co-, Fe-, and Ni-Base Alloys Evaluated at 982 C (1800 F) could give a reasonable simulation of long-time power plant operation. Iron- (Fe-), nickel- (Ni-), and cobalt- (Co-) based high-temperature alloys with sufficient chromium (Cr) and/or aluminum (Al) content can exhibit excellent oxidation resistance. The protective oxides formed by these classes of alloys are typically Cr2O3 and/or Al2O3, and are usually influenced by their Cr, or Cr and Al, content. Sixty-eight Co-, Fe-, and Ni-base high-temperature alloys, typical of those used at this temperature or higher, were used in this study. At the NASA Lewis Research Center, the alloys were tested and compared on the basis of their weight change as a function of time, x-ray diffraction of the protective scale composition, and the physical appearance of the exposed samples. Although final appearance and x-ray diffraction of the final scale products were two factors used to evaluate the oxidation resistance of each alloy, the main criterion was the oxidation kinetics inferred from the specific weight change versus time data. These data indicated a range of oxidation behavior including parabolic (typical of isothermal oxidation), paralinear, linear, and mixed-linear kinetics.

Barrett, Charles A.↗

An assessment of buffer strips for improving damage tolerance of composite laminates at elevated temperature

Buffer strips greatly improve the damage tolerance of graphite/epoxy laminates loaded in tension. Graphite/polyimide buffer strip panels were made and tested to determine their residual strength at ambient and elevated (177 C) temperature. Each panel was cut in the center to represent damage. Panels were radiographed and crack-opening displacements were recorded to indicate fracture, fracture arrest, and the extent of damage in the buffer strip after arrest. All panels had the same buffer strip spacing and width. The buffer strip material was 0 deg S-glass/PMR-15. The buffer strips were made by replacing narrow strips of the 0 deg graphite plies with strips of the 0 deg S-glass on either a one-for-one or a two-for-one basis. Half of the panels were heated to 177 + or - 3 C before and during the testing. Elevated temperature did not alter the fracture behavior of the buffer configuration.

Bigelow, C. A.↗

A film-rupture model of hydrogen-induced, slow crack growth in acicular alpha-beta titanium

A study has been conducted of the terrace-like fracture morphology of gaseous hydrogen-induced crack growth in acicular alpha-beta titanium alloys in terms of specimen configuration, magnitude of applied stress intensity, test temperature, and hydrogen pressure. Although the overall appearance of the terrace structure remained essentially unchanged, a distinguishable variation is found in the size of the individual terrace steps, and step size is found to be inversely dependent upon the rate of hydrogen-induced slow crack growth. This inverse relationship is independent of all the variables investigated. These observations are quantitatively discussed in terms of the formation and growth of a thin hydride film along the alpha-beta boundaries and a qualitative model for hydrogen-induced slow crack growth is presented, based on the film-rupture model of stress corrosion cracking.

Nelson, H. G.↗

The Evolution of Interfacial Sliding Stresses During Cyclic Push-in Testing of C- and BN-Coated Hi-Nicalon Fiber-Reinforced CMCs

Interfacial debond cracks and fiber/matrix sliding stresses in ceramic matrix composites (CMCs) can evolve under cyclic fatigue conditions as well as with changes in the environment, strongly affecting the crack growth behavior, and therefore, the useful service lifetime of the composite. In this study, room temperature cyclic fiber push-in testing was applied to monitor the evolution of frictional sliding stresses and fiber sliding distances with continued cycling in both C- and BN-coated Hi-Nicalon SiC fiber-reinforced CMCs. A SiC matrix composite reinforced with C-coated Hi-Nical on fibers as well as barium strontium aluminosilicate (BSAS) matrix composites reinforced with BN-coated (four different deposition processes compared) Hi-Nicalon fibers were examined. For failure at a C interface, test results indicated progressive increases in fiber sliding distances during cycling in room air but not in nitrogen. These results suggest the presence of moisture will promote crack growth when interfacial failure occurs at a C interface. While short-term testing environmental effects were not apparent for failure at the BN interfaces, long-term exposure of partially debonded BN-coated fibers to humid air resulted in large increases in fiber sliding distances and decreases in interfacial sliding stresses for all the BN coatings, presumably due to moisture attack. A wide variation was observed in debond and frictional sliding stresses among the different BN coatings.

Eldridge, J. I.↗

Comparison of experimental and theoretical thermal fatigue lives for five nickel-base alloys.

Alloys investigated were Nimonic 90, IN 100, coated IN 100, B 1900, coated B 1900, MAR M200, and MAR M200DS (directionally solidified). Maximum temperatures ranged from 770 to 1120 C. Specimen geometries included tapered disks, double-edged wedges, and cambered airfoils. The disks and wedges were heated and cooled in fluidized beds. The airfoil specimens were heated by a Mach 1 natural gas burner and rapid-air cooled, with and without spanwise loading. Life calculations included two distinct failure modes: conventional low-cycle fatigue and cyclic creep. The complete life calculation system included the calculation of transient temperature distributions, thermal strains, stresses, creep damage, fatigue damage, and finally cycles to first crack. Calculated lives were within a factor of two for 76 of the 86 data points analyzed.

Spera, D. A.↗

Evaluation of two polyimides and of an improved liner retention design for self-lubricating bushings

Two different polyimide polymers were studied and the effectiveness of a design feature to improve retention of the self lubricating composite liners under high load was evaluated. The basic bearing design consisted of a molded layer of chopped graphite-fiber-reinforced-polyimide (GFRP) composite bonded to the bore of a steel bushing. The friction, wear, and load carrying ability of the bushings were determined in oscillating tests at 25, 260 and 315 C at radial unit loads up to 260 MPa. Friction coefficients were typically 0.15 to 0.25. Bushings with liners containing a new partially fluorinated polymer were functional, but had a lower load capacity and higher wear rate than those containing a more conventional, high temperature polyimide. The liner retention design feature reduced the tendency of the liners to crack and work out of the contact zone under high oscillating loads.

Sliney, H. E.↗

Experimental study of ceramic coated tip seals for turbojet engines

Ceramic gas-path seals were fabricated and successfully operated over 1000 cycles from flight idle to maximum power in a small turboshaft engine. The seals were fabricated by plasma spraying zirconia over a NiCoCrAlX bond boat on the Haynes 25 substrate. Coolant-side substrate temperatures and related engine parameters were recorded. Post-test inspection revealed mudflat surface cracking with penetration to the ceramic bond-coat interface.

Biesiadny, T. J.↗

Experimental study of ceramic-coated tip seals for turbojet engines

Ceramic gas-path seals were fabricated and successfully operated over 1000 cycles from flight idle to maximum power in a small turboshaft engine. The seals were fabricated by plasma spraying zirconia over a NiCoCrAlX bond coat on the Haynes 25 substrate. Coolant-side substrate temperatures and related engine parameters were recorded. Post-test inspection revealed mudflat surface cracking with penetration to the ceramic bond-coat interface.

Biesiadny, T. J.↗

Adherent Thermal Barrier For Combustion Chamber

In improved method, fabrication begins with machining of aluminum mandrel to requisite cylindrical shape. Heat-barrier coating - yttria-stablized zirconia - plasma-sprayed on mandrel to thickness of 0.076 mm. Nickel/chromium layer about 0.025 mm thick sprayed on zirconia. Thin zirconia coating reduces maximum operating temperature of copper wall of chamber from 844 to 334 K. At lower temperature, copper liner stronger and undergoes less strain and less tendency to distort and crack.

Quentmeyer, Richard J.↗

The constitutive representation of high-temperature creep damage

The elastic-viscoplastic constitutive equations of Bodner-Partom were applied to modeling creep damage in a high temperature Ni-alloy, B1900 + Hf. Both tertiary creep in bulk materials and creep crack growth in flawed materials were considered. In the latter case, the energy rate line integral was used for characterizing the crack driving force, and the rate of crack extension was computed using a local damage formulation that assumed fracture was controlled by cavitation occurring within the crack-tip process zone. The results of this investigation were used to assess the evolution equation for isotropic damage utilized in the Bodner-Partom constitutive equations.

Chan, K. S.↗

CMCs for the long run

The structural and environmental requirements for ceramic matrix composites (CMCs) are most demanding in aerospace applications involving human transport; this need for extreme reliability has led to intensive investigations of criteria for high CMC integrity. The ideal properties of a fiber-reinforced CMC have been found to depend on the use of high aspect ratio fibers capable of maximum strength retention during fabrication, uniform fiber infiltration by the matrix material, high matrix oxidation resistance in elevated temperature applications, and a fiber/matrix interface that accommodates debonding in the presence of matrix cracks.

Dicarlo, James A.↗

Constitution of pseudobinary hypoeutectic beta-NiAl + alpha-V alloys

The formation of pseudobinary eutectics between NiAl (beta) and V (alpha) at high temperatures was investigated as a possible way of improving the ductility and toughness of the alloy. It is found that a pseudobinary eutectic, characterized by a large beta+alpha field, is formed in the Ni-Al-V ternary system below about 1370 C. The high-temperature solubility of V in beta is about 14 percent, decreasing markedly with decreasing temperature and increasing Al content above 50 at. pct Al. The pseudobinary hypoeutectic exibits crack resistance under indentation loading.

Cotton, J. D.↗

Elevated temperature axial and torsional fatigue behavior of Haynes 188

The results of high-temperature axial and torsional low-cycle fatigue experiments performed on Haynes 188, a wrought cobalt-base superalloy, are reported. Fatigue tests were performed at 760 C in air on thin-walled tubular specimens at various ranges under strain control. Data are also presented for coefficient of thermal expansion, elastic modulus, and shear modulus at various temperatures from room to 1000 C, and monotonic and cyclic stress-strain curves in tension and in shear at 760 C. The data set is used to evaluate several multiaxial fatigue life models (most were originally developed for room temperature multiaxial life prediction) including von Mises equivalent strain range (ASME boiler and pressure vessel code), Manson-Halford, Modified Multiaxiality Factor (proposed here), Modified Smith-Watson-Topper, and Fatemi-Socie-Kurath. At von Mises equivalent strain ranges (the torsional strain range divided by the square root of 3, taking the Poisson's ratio to be 0.5), torsionally strained specimens lasted, on average, factors of 2 to 3 times longer than axially strained specimens. The Modified Multiaxiality Factor approach shows promise as a useful method of estimating torsional fatigue life from axial fatigue data at high temperatures. Several difficulties arose with the specimen geometry and extensometry used in these experiments. Cracking at extensometer probe indentations was a problem at smaller strain ranges. Also, as the largest axial and torsional strain range fatigue tests neared completion, a small amount of specimen buckling was observed.

Bonacuse, Peter J.↗