Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooling system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Ring Model Development and Validation for Prismatic HTGR Core Thermal-hydraulics and Safety Analysis

Because of the complex core geometry, prismatic high temperature gas-cooled reactors (prismatic HTGRs) often exhibit complex thermal fluid behaviors during both normal operating and transient conditions. Most HTGR designs rely on passive safety system for decay heat removal, such as the reactor cavity cooling system (RCCS). During postulated accidents like Pressurized Conduction Cooldown (PCC) event, the decay heat is first radially transferred from the core region to the reactor vessel outer surface, then to the RCCS cooling panels. The peak fuel temperature is controlled by heat transfer mechanisms with two distinctive characteristic length scales, i.e., the core-wise effective heat conduction and local heat conduction in the fuel pellet scale. As both length scales are essential to determine the fuel temperature, from the modeling perspective, computer codes must be able to capture heat transfer in both scales. This is challenging for both computational fluid dynamics (CFD) tools because of extremely large amount of computation resources required, and for system analysis codes because of the challenge to model the complex core geometry. Under the support of DOE-NE’s Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, efforts have been pursued to support HTGR technology development and its modeling and simulation needs. There is a particular need for advanced modeling and simulation tools to predict thermal-fluid behavior during safety-related transients. In our previous studies, the ring model was adopted in SAM and further developed to simulate the normal operating condition and a PCC event using the MHTGR-350 design of General Atomics as the reference design. This current work represents a continuation of these previous efforts, and the focus is to critically review and examine simplifications and assumptions made to develop the ring model, and to perform code validation using experimental data from an integral-effect test facility, the High Temperature Test Facility (HTTF) at the Oregon State University. In this study, the test PG-27 from the HTTF test suite was selected for code validation purpose. The test PG-27 is a transient test designed to simulate the PCC event of the MHTGR design. Very good agreements between SAM prediction and experimental measurements were found in both coolant and solid structure temperatures during the transient.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Rehydrated glass embayments record the cooling of a Yellowstone ignimbrite

Abstract Hydration fronts penetrate 50–135 μm into glassy rhyolite embayments hosted in quartz crystals from the Mesa Falls Tuff in the Yellowstone Plateau volcanic field. The hydration fronts occur as steep enrichments that reach 2.4 ± 0.6 wt% H2O at the embayment opening, representing much higher values than interior concentrations of 0.9 ± 0.2 wt% H2O. Molecular water accounts for most of the water enrichment. Water speciation indicates the hydration fronts comprise absorbed meteoric water that modified the original magmatic composition of the rhyolitic glass. We used finite difference diffusion models to demonstrate that glass rehydration was likely produced over a few decades as the ignimbrite cooled. Such temperatures and time scales are consistent with rare firsthand observations of decadal hydrothermal systems associated with cooling ignimbrites at Mount Pinatubo (Philippines) and the Valley of Ten Thousand Smokes (Alaska).

Geology↗

Code Benchmark of the HTTF Pressurized Conduction Cooldown Test Using SAM

The High Temperature Test Facility (HTTF) at Oregon State University is an integral system test facility to simulate postulated reactor transients of prismatic high-temperature gas-cooled reactors(HTGRs). A series of test campaigns was launched, providing abundant test data that could be used to benchmark reactor system analysis codes like the System Analysis Module (SAM). In this study, a SAM model of the facility is developed based on the two-dimensional (2D) ring model approach. All components including the ceramic matrix, graphite heaters, helium coolant channels, core barrel, upcomer, pressure vessel, and reactor cavity cooling system are modeled as concentric cylindrical rings. The model is used to simulate one of the benchmark problems-Pressurized Conduction Cooldown (PCC)-within the scope of the Organisation for Economic Co-operation and Development Nuclear Energy Agency International HTTF Benchmark. The simulations consist of two parts. In the first part, operating and boundary conditions as well as thermophysical properties of materials are specified for the benchmark problem. In this work, results from the first part will be used in code-to-code comparison. In the second part, the SAM model is used to simulate Test PG-27, which is the first PCC test carried out in the HTTF, with only two of the ten heater banks activated. The results in the second part are used for code-to-data comparison. Because the helium coolant flow rate is not measured in this facility, it is estimated using the input power and inlet/outlet coolant temperatures. Additionally, radial heat flow in the ceramic blocks is complicated by hundreds of cylindrical coolant channels and heater rods embedded in them. As such, it is necessary to deduce an effective thermal conductivity for the ceramic to analyze the core thermal behavior. SAM predictions of the helium coolant and ceramic temperatures are compared with test data measured in three equivalent sectors. Overall, the SAM results agree reasonably well with test data within the variation of data among the three sectors, which demonstrates SAM's capability in capturing transient effects in HTGR using the simplified 2D ring model.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optical stochastic cooling at Fermilab’s IOTA ring

Stochastic cooling (SC) constitutes one of the greatest conceptual and technological achievements in particle beam cooling. Numerous SC systems have been built in the microwave regime and used to extend the science reach of accelerator facilities worldwide. The ability to sense and correct the particle ensemble using high-bandwidth feedback systems is at the core of the concept. Here, we describe the first realization of SC at optical frequencies and bandwidths. The demonstration was recently carried out at Fermilab’s integrable optics test accelerator (IOTA) storage ring using the transit-time method of optical stochastic cooling (OSC) and achieved an integrated system bandwidth of approximately 20 THz, which is more than 2000 times that of conventional SC systems. This demonstration establishes the foundation for more advanced OSC experiments with high-gain amplification, currently underway at Fermilab, and the eventual application of OSC to colliders and other accelerator facilities.

Jarvis, Jonathan D. [Fermilab]↗

Reliability Assessment of Cooling Fans for PV Inverters: Testing, Modeling, and Case Studies

The reliability of photovoltaic (PV) inverters is critical for long-term solar system performance, with cooling fan failures frequently leading to costly downtime. While much research exists on general cooling fan reliability, little attention has been given to fans operating within PV inverters and their unique environmental challenges. Here, this article proposes a comprehensive methodology to address this gap. First, a failure mode and effects analysis is performed on fans to identify the key failure mechanisms in PV applications, their corresponding stressors, and the models necessary for lifetime prediction. Second, an accelerated life test is designed and conducted to collect valuable experimental data for PV inverter fans in a reasonable amount of time. Third, a mathematical conversion of dynamic mission profiles into effective constant stress levels is derived. Fourth, case studies are given, showcasing lifetime estimates that account for geographic variations in mission profile data. The results demonstrate that this integrated approach leads to an accurate reliability assessment for PV inverter cooling fans.

accelerated life testing (ALT)↗

Addressing Data Center Cooling Needs through the Use of Subsurface Thermal Energy Storage Systems

This study aims to evaluate the feasibility of addressing the cooling needs for information technology (IT) equipment in data centers by using reservoir thermal energy storage (RTES) to provide reliable and sustainable low-temperature fluid. This project focuses on the technical viability of operating such a system in Houston, Texas, which is a representative location for crypto mining data centers. An analysis has been performed to investigate the technical feasibility with climate data for Houston. Results show that data centers on the scale of 30 MW, and operating at a temperature of 27 degrees C, can be reliably cooled by a combined RTES and dry coolers setup. A techno-economic analysis will be performed and energy/water saving benefits will be quantified in the future. In addition, the study will be extended to other representative data center locations with different climates and geographical locations.

cooling↗

University of Hawai‘i, Shallow Geothermal Resources: Energy Technology Innovation Partnership Project (Final Report)

Scientists at Lawrence Berkeley National Laboratory (Berkeley Lab) have teamed up with the University of Hawai‘i at Manoa (UH Manoa) through the U.S. Department of Energy’s Energy Technology Innovation Partnership Project to evaluate the technological and market feasibility of shallow geothermal heat exchanger (GHE) technology. UH requested this analysis to evaluate opportunities in building cooling, energy efficiency, and emissions reduction applications in Hawai‘i. UH has an abundance of geologic and geothermal data and is looking to the national labs’ expertise to execute this analysis. UH is also interested in investigating policy, regulatory, and business conditions advantageous for implementation of a pilot project and more broad deployment of this technology in Hawai‘i. In many locations around the world, the demands for heating and cooling are roughly balanced over the course of the year, so GHEs do not cause significant long-term changes in subsurface temperature. This is not the case in Hawai’i, where the demand for heating is very small, meaning that, over time, GHEs will add heat to the subsurface. If temperatures increase significantly, GHE systems will not work as designed. Regional groundwater flow has the potential to sweep heated water away from boreholes, thereby maintaining the functionality of the GHE system. Significant regional groundwater flow requires two things: a sufficiently large driving hydraulic head gradient (usually closely related to surface topography), and sufficient porosity and permeability to enable groundwater to flow in large enough quantities to enable near-borehole temperatures to be maintained at ambient values. Hawai‘i’s volcanic terrain offers ample surface topographic variation. The lava itself shows an extremely large range of porosity and permeability, so sites with large enough values of these properties must be selected. Numerical modeling of coupled groundwater and heat flow can be used to determine how large is large enough. Primarily, closed-loop systems have been investigated. Other options considered are open-loop systems and using cool seawater as the chilling source. Project work investigated the feasibility of GHE technology at two scales. At the island scale, GIS layers of various attributes relevant for GHE were combined to develop an overall favorability map for employing GHE in Hawai‘i. At the local scale, a hydrogeologic model for the subsurface component of a closed-loop system was developed for the Stan Sheriff Center at the UH Manoa campus. This site is considered promising because the rock below and immediately downgradient of the borefield is highly permeable, consisting of a subsurface karst system (limestone containing high-permeability open channels), which is underlain by a thick, high-permeability fractured basalt. Moreover, the site is near the base of the Ko‘olau Range, providing a large hydraulic head gradient. Thus, groundwater flow through the site is expected to be large, enabling efficient removal of heated groundwater. A full-GHE-system model of the site was also developed, with a simplified representation of the subsurface, in which groundwater flow is not considered and heat transfer is purely by conduction. Using the building cooling load data provided by UH, simulation results show that with groundwater flow present, a GHE can operate successfully for at least 10 years, but with no groundwater flow, the subsurface begins to heat up after only one year of operation, making the GHE unviable within 2-6 years. The team also developed a techno-economic model for this site to compare the cost of cooling using a GHE system with the costs of operating the current air-conditioning system. The GHE system is advantageous economically if favorable tax incentives and interest rates can be obtained.

15 GEOTHERMAL ENERGY↗

Cryogenic Considerations for Superconducting Magnet System Design for the Material Plasma Exposure eXperiment (MPEX)

The Material Plasma Exposure eXperiment (MPEX) has been proposed as a facility to address plasma material interaction knowledge gaps to qualify and develop materials and technologies that surround plasma environments for future fusion reactors. Utilizing different radio-frequency (rf) heating technologies, MPEX is a linear plasma device that will generate fusion reactor–like plasmas with energies and particle fluxes at the target materials with electron temperatures of 1 to 15 eV, electron densities of 10 20 to 10 21 m -3 , and ion fluxes greater than 10 24 m -2 s -1 . Starting with the MPEX requirements with respect to magnetic fields between 0.1 and 2.5 T and warm bores of either 0.65 m or 1.56 m, conceptual designs for a superconducting magnet system have been developed that utilize multiple NbTi windings distributed across seven cryostats to accommodate rf heating, water cooling, and vacuum systems needed for MPEX. While the cryogenic and magnet technologies relative to the field and space requirements are mature, the integration of these technologies across multiple cryostats presents several technical and logistical challenges. An analysis of the preferred refrigeration approach, modular recondensing liquid helium cryocoolers, was performed. Utilizing a design margin of a factor of two, this approach is feasible within the current design requirements for MPEX with some considerations related to its implementation within the thermal shields and the magnet subsystem geometries.

Duckworth, Robert↗

Research and Development of a Ventilation-Integrated Comfort System

From an indoor air quality perspective, the best residential ventilation strategies include filtering outdoor air and distributing that air to all occupied parts of a home. From an energy standpoint, it is desirable that energy be transferred from the exhaust air to the incoming outdoor air to limit heating and cooling impacts. Heat or energy recovery ventilators (HRVs or ERVs) can provide these functions, but researchers have seen many poor installations related to design, installation, and operation and maintenance. More robust ventilation systems may involve an ERV with a dedicated duct distribution system and controls. Such a duct system can be costly to install, and many builders reduce these costs by connecting an ERV to a central heating and cooling duct system. Although this can sometimes be done effectively, researchers have seen consistent challenges with low, inconsistent, or imbalanced flow rates; high electricity consumption; and—of greatest concern—outdoor air short-circuiting or not being delivered to occupied spaces at all. Most ERVs are designed to operate with their own duct system; they are not designed as an add-on to much larger heating, ventilating, and air-conditioning (HVAC) systems. The ventilation-integrated comfort system (VICS) is expressly designed to integrate with low-capacity, efficient, ducted heating and cooling systems. Overall, the latest VICS prototype consumed 40–75 watts (W), including the air handler power, to deliver 50–120 cfm of whole-dwelling ventilation. The large, cross-flow ERV core performed to match manufacturer values (73% winter sensible effectiveness, 64% summer total effectiveness), but further improvements are possible. The VICS system researched and tested during this project will provide efficient, controllable, balanced energy recovery ventilation that is integrated with heating and cooling systems. The integration reduces space and ductwork needed for separate ventilation systems, and there are no compromises to heating, cooling, or ventilation performance. The integrated nature of the device also reduces risks for improper installation and commissioning. Even when using the air handler blower to distribute outdoor air, the total power consumption is lower than that of most available ERV products in the same airflow range. This system has the potential to offer very high-performance ventilation with much smoother and simpler installation than conventional systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A review on nearly isothermal compression technology

Compressors can be described as the heart of a vapor compression refrigeration system, circulating the working fluid in the system. Significant benefits can be gained from improving its efficiency since energy consumption is responsible for almost the entire system's power input. An effort has been made to achieve isothermal compression through liquid refrigerant injection or inter-stage cooling in refrigeration systems. In recent years, much effort has been invested into isothermal compression technology for air compressors or compressed air energy storage systems with the rise of renewable energy. Here, this work has explored the advancements made in this area and categorized them to discuss the benefits, limitations, and tradeoffs. Evidently, increasing heat transfer area is a significant aid in improving heat transfer, resulting in better isothermal compression. However, liquid pistons open more avenues for this to be pursued, and therefore, are limited to air compression applications. In addition, water injection proved to be the most effective among the methods. Finally, there is a need for more experimental research on refrigeration applications and the field is still in its infancy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sorption heat pump and control method

A method operates an absorption heat pump system, specifically the flow of hydronic cooling fluid through the condenser during system start-ups, or when the cooling fluid temperature is low. To minimize the time for an absorption heat pump to reach full cooling or heating capacity, it is desirable for the high side pressure to increase as fast as possible, and the low side pressure to decrease as fast as possible. Since the high side pressure is a function of the temperature of the refrigerant exiting the condenser, if the condenser cooling fluid temperature is low, the corresponding high side pressure will be low, which may not permit adequate working fluid flow rates from the high pressure side of the system to the low pressure side.

Garrabrant, Michael A.↗

Department of Energy/IDEA: More best-practices research

This article continues the overview of the U.S. Department of Energy and IDEA collaboration by highlighting additional case studies that demonstrate innovative engineering approaches in district energy systems. It focuses on how campuses are improving efficiency, integrating advanced technologies, and reducing energy use and emissions through data-driven strategies. The University of Cincinnati is featured for its highly efficient chilled water system, using advanced algorithms and upgraded “smart chillers” to optimize performance, reduce energy consumption, and lower costs. Wake Forest University emphasizes a data-informed modernization process, using system optimization and targeted building improvements to significantly boost efficiency and reduce overall energy use. Arizona Western College showcases creative solutions to extreme cooling demands, including system redesign, smart controls, and thermal storage to improve reliability and cut peak energy costs. Overall, the article demonstrates that combining innovative engineering, real-time data analysis, and system optimization can significantly enhance performance, reduce emissions, and deliver cost savings in district energy systems.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Hygroscopic cooling tower for waste water disposal

In various embodiments, the present invention relates to heat dissipation systems including a hygroscopic working fluid integrating waste water as makeup water. The present invention also relates to methods of using the same. The present invention also relates to hygroscopic cooling systems adapted to dispose of waste water by combining the waste water with a hygroscopic working fluid, precipitating impurities and evaporating the remaining water.

Martin, Christopher Lee↗

Hygroscopic cooling tower for waste water disposal

In various embodiments, the present invention relates to heat dissipation systems including a hygroscopic working fluid integrating waste water as makeup water. The present invention also relates to methods of using the same. The present invention also relates to hygroscopic cooling systems adapted to dispose of waste water by combining the waste water with a hygroscopic working fluid, precipitating impurities and evaporating the remaining water.

Martin, Christopher Lee↗

Experimental study of a tri-functional propane hydronic heat pump

This study investigates the performance of a propane hydronic heat pump system for space cooling, heating, and water heating applications, focusing on various operational conditions, with a total refrigerant charge below 1200 g. Cooling performance was evaluated at different outdoor temperatures, compressor stages (capacity levels), and water flow rates. The results showed that the coefficient of performance (COP) for cooling was higher at lower outdoor temperatures, with peak values exceeding 5.0 under low-stage operation and lower water flow rate. The cooling capacity increased with higher flow rates and compressor stages, reaching 12 kW. Space heating performance, evaluated at ambient temperatures ranging from −8.3 °C to 16.7 °C, revealed a decrease in COP with lower temperatures. However, high-stage operation maintained higher heating capacities even at low temperatures. The system demonstrated high Heating Seasonal Performance Factors (HSPF), exceeding 10.0. For water heating, the COP decreased with lower ambient temperatures and higher supply water temperatures. The system efficiently heated an 189-L water tank, outperforming conventional water heaters, with process COPs exceeding 4.0 under cooling-season conditions. Despite some efficiency loss due to defrosting at low temperatures, the propane heat pump consistently delivered strong performance. Seasonal energy efficiency ratios (SEER) and seasonal heating COP values indicated significant overall efficiency. The study concludes that propane is a promising refrigerant for heat pump systems, with future research needed to future reduce total system charge and optimize system performance through advanced controls and heat exchanger designs.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Development of a metamodelling framework for building energy models with application to fifth-generation district heating and cooling networks

Fully defined physics-based building energy models can accurately represent building systems; however, generating models based on high-level parameters is time consuming and simulation time of complex models can be slow. This article discusses the development of a Metamodelling Framework to create metamodels from a building energy modelling dataset. The framework generates metamodels using either linear regression, random forests, or support vector regressions. A fifth-generation district heating and cooling system analysis use case was used to motivate the development of the framework. The use case required quick and accurate representations of annual building loads reported hourly. Typical annual building modelling approaches can result in a runtime of 10 min. The metamodels runtime was reduced to less than 10 s to load and run an annual simulation with user-defined covariates. The results of the metamodel performance and an abbreviated topology analysis based on the motivating use case will be presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Validation of a Simulation Testbed for the Intelligent Building Agents Laboratory (IBAL) Using TRNSYS

This paper documents the development and validation of a dynamic primary cooling and thermal storage system simulation testbed. The system simulation testbed, sIBAL, is based on the Intelligent Building Agents Laboratory (IBAL) at the National Institute of Standards and Technology (NIST), which is a research infrastructure and testbed for the development, evaluation, and demonstration of intelligent control algorithms. The sIBAL testbed developed in this project will serve as a virtual twin of the real facility for future control algorithm development. The details of the methodologies used to develop and validate the simulation testbed, which replicates the dynamic behaviors of the primary cooling and ice storage system in the IBAL facility, are presented. The simulation testbed was developed in TRNSYS using built-in component models and MATLAB functions to replicate the two water-cooled chillers, a thermal storage tank, pumps, valves and other components for four different operation modes. Experiments on IBAL components were designed and executed to generate experimental data for model development and verification of the simulation platform. The validation of the simulation results was carried out in two phases: 1) independent component simulations for the chillers and thermal storage tank, and 2) a combined testbed simulation of the entire hydronic system. Comparison of simulation results to the experimental data obtained from the IBAL facility showed errors within 1 °C for the temperatures outputs of both the chiller and the thermal storage model. The error is within an acceptable range for further intelligent control algorithms development. The findings from the study are summarized and presented along with areas where additional research is needed. In addition, data filtering procedures and model refinement measures utilized to improve the accuracy and accelerate the computation time of the simulation are presented.

cooling systems↗

Continuous Monitoring and Partial Water Softening for Cooling Tower Water Treatment

Cooling towers are an integral component of many refrigeration systems, providing comfort or process cooling across a broad range of applications. They are the point in the system where heat is dissipated to the atmosphere through the evaporative cooling process. Cooling towers are commonly found in industrial applications and are also often used in water-cooled chilled water plants in medium to large commercial buildings. Continuous monitoring and partial water softening for cooling towers used in medium to large commercial buildings are the focus of this paper. Cooling towers consume large amounts of water. Cooling tower-related water consumption is one of largest potable water loads within buildings in the United States, with substantial building water use associated with heating and cooling. Regional water shortages have highlighted a need to reduce water consumption; the U.S. General Services Administration (GSA) and Executive Order 13834 place priority on reducing water consumption. This priority has fueled interest in the identification, investigation, and potential broad deployment of cost-effective opportunities to reduce water use, such as alternative water treatment (AWT) technologies for cooling towers. Traditional water treatment approaches use chemicals to extend the ability of the water to hold scaling minerals in suspension, minimize corrosion, and prevent biological growth. This treatment protects the chillers and cooling tower equipment; however, even when chemicals are used regularly, a certain percentage of condenser water must be drained and made up with fresh water to maintain system water quality parameters. In addition, the use of chemicals sometimes creates a waste disposal issue and can cause building owners to incur additional fees, such as disposal or wastewater charges. To manage cooling tower water treatment, GSA typically contracts with a company specializing in conventional chemical maintenance for a fixed fee. While there are many types and vendors of AWT systems, this project assesses the effectiveness of one technology provided by Aqualogix. This system is a chilled water plant monitoring and control system aimed at optimizing system performance by reducing the blowdown occurrences used to remove mineral build-up. The technology consists of two components – continuous programmable logic control (PLC) monitoring and side-stream filtration with partial water softening. PLC monitoring calculates cycles of concentration (CoC) and determines the optimum amount of blowdown water required to satisfy all water chemistry requirements. Side-stream filtration removes suspended matter and improves biocide efficacy while precisely dispensing softened water to achieve optimal makeup water hardness. Unlike other AWT systems evaluated by GSA to date, this system does not replace the legacy treatment system but is used in addition to chemical water treatment. The vendor claims their technology will reduce water consumption, water discharge, and maintenance costs. The AWT system evaluated in this demonstration is a commercialized technology. Given its commercialized state, the system evaluated in this report is at a Technology Readiness Level 9 according to National Aeronautics and Space Administration (NASA) definitions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗