Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooling load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Gas cooled faraday rotator and method

To enable several orders of magnitude increases in average power and energy handling capability of Faraday rotators, the technology utilizes high speed gas cooling to efficiently remove thermal loading from the Faraday optic faces while minimizing the thermal wavefront and thermal birefringence by creating a longitudinal thermal gradient. A recirculating gas cooling manifold accelerates the gas over the surface of the slab to create a turbulent flow condition which maximizes the surface cooling rate. The technology further provides a spatially uniform thermal profile on the Faraday slabs.

Bayramian, Andrew J.↗

MEMS Device Being Developed for Active Cooling and Temperature Control

High-capacity cooling options remain limited for many small-scale applications such as microelectronic components, miniature sensors, and microsystems. A microelectromechanical system (MEMS) is currently under development at the NASA Glenn Research Center to meet this need. It uses a thermodynamic cycle to provide cooling or heating directly to a thermally loaded surface. The device can be used strictly in the cooling mode, or it can be switched between cooling and heating modes in milliseconds for precise temperature control. Fabrication and assembly are accomplished by wet etching and wafer bonding techniques routinely used in the semiconductor processing industry. Benefits of the MEMS cooler include scalability to fractions of a millimeter, modularity for increased capacity and staging to low temperatures, simple interfaces and limited failure modes, and minimal induced vibration.

Moran, Matthew E.↗

Cool Roof Systems; What is the Condensation Risk?

A white roof, or cool roof, is constructed to decrease thermal loads from solar radiation, therefore saving energy by decreasing the cooling demands. Unfortunately, cool roofs with a mechanically attached membrane have shown a higher risk of intermediate condensation in the materials below the membrane in certain climates (Ennis & Kehrer, 2011) and in comparison with similar constructions with a darker exterior surface (Bludau, Zirkelbach, & Kuenzel, 2009). As a consequence, questions have been raised regarding the sustainability and reliability of using cool roof membranes in northern U.S. climate zones.

Kehrer, Manfred↗

Analytical and experimental spur gear tooth temperature as affected by operating variables

A gear tooth temperature analysis was performed using a finite element method combined with a calculated heat input, calculated oil jet impingement depth, and estimated heat transfer coefficients. Experimental measurements of gear tooth average surface temperatures and instanteous surface temperatures were made with a fast response infrared radiometric microscope. Increased oil jet pressure had a significant effect on both average and peak surface temperatures at both high load and speeds. Increasing the speed at constant load and increasing the load at constant speed causes a significant rise in average and peak surface temperatures of gear teeth. The oil jet pressure required for adequate cooling at high speed and load conditions must be high enough to get full depth penetration of the teeth. Calculated and experimental results were in good agreement with high oil jet penetration but showed poor agreement with low oil jet penetration depth.

Townsend, D. P.↗

Analytical and experimental spur gear tooth temperature as affected by operating variables

A gear tooth temperature analysis was performed using a finite element method combined with a calculated heat input, calculated oil jet impingement depth, and estimated heat transfer coefficients. Experimental measurements of gear tooth average surface temperatures and instantaneous surface temperatures were made with a fast response infrared radiometric microscope. Increased oil jet pressure had a significant effect on both average and peak surface temperatures at both high load and speeds. Increasing the speed at constant load and increasing the load at constant speed causes a significant rise in average and peak surface temperatures of gear teeth. The oil jet pressure required for adequate cooling at high speed and load conditions must be high enough to get full depth penetration of the teeth. Calculated and experimental results were in good agreement with high oil jet penetration but showed poor agreement with low oil jet penetration depth.

Townsend, D. P.↗

Instrumentation, control and data management for the MIST (Modular Integrated Utility System) Facility

An appendix providing the technical data required for computerized control and/or monitoring of selected MIST subsystems is presented. Specific computerized functions to be performed are as follows: (1) Control of the MIST heating load simulator and monitoring of the diesel engine generators' cooling system; (2) Control of the MIST heating load simulator and MIST heating subsystem including the heating load simulator; and (3) Control of the MIST air conditioning load simulator subsystem and the MIST air conditioning subsystem, including cold thermal storage and condenser water flows.

Celino, V. A.↗

Numerical investigation on transverse heat transfer properties in cross section of full size Nb{sub 3}Sn CICC ITER conductor

The contact mechanical characteristics in the cross section of the Nb{sub 3}Sn cable are sensitive to the cryogenic cooling and cyclic transverse electromagnetic loads, which may affect the cable’s performance. In this paper, based on a proposed discrete dynamic model (DEM), where the contact heat transfer among strands and the convective heat transfer in liquid helium are taken into account, the cooling process under two heat transfer mechanisms is performed. Simulation results show that the temperature variation of Poloidal Field Insert Sample (PFIS) cable with time agrees well with the existing experimental results, and the role of contact heat transfer cannot be neglected during cryogenic cooling. It is obtained from the further analysis that the effect of contact heat transfer becomes more prominent with the decrease of mass flow rate of liquid helium, which leads to the stress status within cable changed significantly. With the temperature boundary condition imposed on the cable radial direction, the effective thermal conductivity (ETC) of cable can be obtained. It can be found that the ETC increases with increasing the transverse loads and is sensitive to the low temperature environment, while it is not affected by load cycles basically. These results may provide the guide for the design and application of the future CICC conductors.

36 MATERIALS SCIENCE↗

Numerical characterization of quasi-steady thermal load for thin crystal at cryogenic temperature with nondiffusive heat transfer

With dramatically improved brightness and repetition rate, the thermal load for crystal optics in x-ray free-electron laser applications has also significantly increased. To mitigate the thermal load, one effective method is cryogenic cooling. However, the emerging nondiffusive heat transfer phenomenon at cryogenic temperature may cause design failure if overlooked. To evaluate the optical performance of thin crystal optics under thermal load at cryogenic temperature, an integrated numerical tool is presented and applied to characterize the thermal load on thin crystals with nondiffusive phenomena accounted. Significant thermally induced distortion of the rocking curve is observed from numerical simulation, leading to potential seed power reduction in hard x-ray self-seeding application. Cryogenic cooling is confirmed necessary by simulation to handle the thermal load at high repetition rate operation.

42 ENGINEERING↗

RF Cavities Loaded with Dielectric for Muon Facilities

This paper discusses RF cavities loaded with dielectric material that could be used in various muon collider facilities. Most of the existing pill-box cavity designs are too large in diameter to fit efficiently in the current cooling lattice designs. The paper describes novel compact dielectric loaded RF cavities designs that fit efficiently in muon cooling lattices and allow multi-frequency cavity designs in the same size cavity by changing the dielectric constant or size. The paper describes the designs of 400 and 800 MHz cavities for the (HCC) helical cooling channel. In addition to the use of the dielectric to reduce the radial size of gas-filled cavities in helical cooling channels, dielectric-loading has the potential use in vacuum cavities for suppression of dark current emission. Cavities that can be used for the phase rotation channel in the front end of a muon collider or neutrino factory are also presented.

43 PARTICLE ACCELERATORS↗

On radiational cooling computations in clouds.

Expressions are derived for the cooling or heating rates for clouds in which the condensed phase is either ice or water. Values are computed for ice and water clouds over a reasonable temperature range for pressures of 1000, 500, and 200 mb. The importance is shown of adequately allowing for the latent load in computations of radiative cooling or heating rates based on measurements of radiative divergence in clouds. It is shown that, other things being equal, the effect of the latent load is always greatest at low levels and higher temperatures.

Knollenberg, R. G.↗

Thermal–mechanical stress analysis of pressurized water reactor pressure vessel with/without a preexisting crack under grid load following conditions

In this paper, we present thermal-mechanical stress analysis of a pressurized water reactor pressure vessel and its hot-leg and cold-leg nozzles. Results are presented from thermal and thermal-mechanical stress analysis under reactor heat-up, cool-down, and grid load-following conditions. Analysis results are given with and without the presence of preexisting crack in the reactor nozzle (axial crack in hot leg nozzle). From the model results it is found that the stress-strain states are significantly higher in case of presence of crack than without crack. In conclusion, the stress-strain state under grid load following condition are more realistic compared to the stress-strain state estimated assuming simplified transients.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Effects of Liquid Cooling Garments on Post-Space Flight Orthostatic Intolerance

Post space flight orthostatic intolerance among Space Shuttle crew members following exposure to extended periods of microgravity has been of significant concern to the safety of the shuttle program. Following the Challenger accident, flight crews were required to wear launch and entry suits (LES). It was noted that overall, there appeared to be a higher degree of orthostatic intolerance among the post-Challenger crews (approaching 30%). It was hypothesized that the increased heat load incurred when wearing the LES, contributed to an increased degree of orthostatic intolerance, possibly mediated through increased peripheral vasodilatation triggered by the heat load. The use of liquid cooling garments (LCG) beneath the launch and entry suits was gradually implemented among flight crews in an attempt to decrease heat load, increase crew comfort, and hopefully improve orthostatic tolerance during reentry and landing. The hypothesis that the use of the LCG during reentry and landing would decrease the degree of orthostasis has not been previously tested. Operational stand-tests were performed pre and post flight to assess crewmember's cardiovascular system's ability to respond to gravitational stress. Stand test and debrief information were collected and databased for 27 space shuttle missions. 63 crewpersons wearing the LCG, and 70 crewpersons not wearing the LCG were entered into the database for analysis. Of 17 crewmembers who exhibited pre-syncopal symptoms at the R+O analysis, 15 were not wearing the LCG. This corresponds to a 21% rate of postflight orthostatic intolerance among those without the LCG, and a 3% rate for those wearing LCG. There were differences in these individual's average post-flight maximal systolic blood pressure, and lower minimal Systolic Blood pressures in those without LCG. Though other factors, such as type of fluid loading, and exercise have improved concurrently with LCG introduction, from this data analysis, it appears that LCG usage provided a significant degree of protection from post-flight orthostatic intolerance.

Billica, Roger↗

Cooling devices and methods for use with electric submersible pumps

Cooling devices for use with electric submersible pump motors include a refrigerator attached to the end of the electric submersible pump motor with the evaporator heat exchanger accepting all or a portion of the heat load from the motor. The cooling device can be a self-contained bolt-on unit, so that minimal design changes to existing motors are required.

42 ENGINEERING↗

Cooling devices and methods for use with electric submersible pumps

Cooling devices for use with electric submersible pump motors include a refrigerator attached to the end of the electric submersible pump motor with the evaporator heat exchanger accepting all or a portion of the heat load from the motor. The cooling device can be a self-contained bolt-on unit, so that minimal design changes to existing motors are required.

42 ENGINEERING↗

Cooling devices and methods for use with electric submersible pumps

Cooling devices for use with electric submersible pump motors include a refrigerator attached to the end of the electric submersible pump motor with the evaporator heat exchanger accepting all or a portion of the heat load from the motor. The cooling device can be a self-contained bolt-on unit, so that minimal design changes to existing motors are required.

42 ENGINEERING↗

Analysis and comparison of wall cooling schemes for advanced gas turbine applications

The relative performance of (1) counterflow film cooling, (2) parallel-flow film cooling, (3) convection cooling, (4) adiabatic film cooling, (5) transpiration cooling, and (6) full-coverage film cooling was investigated for heat loading conditions expected in future gas turbine engines. Assumed in the analysis were hot-gas conditions of 2200 K (3500 F) recovery temperature, 5 to 40 atmospheres total pressure, and 0.6 gas Mach number and a cooling air supply temperature of 811 K (1000 F). The first three cooling methods involve film cooling from slots. Counterflow and parallel flow describe the direction of convection cooling air along the inside surface of the wall relative to the main gas flow direction. The importance of utilizing the heat sink available in the coolant for convection cooling prior to film injection is illustrated.

Colladay, R. S.↗

Effects of Aerosol on Atmospheric Dynamics and Hydrologic Processes during Boreal Spring and Summer

Global and regional climate impacts of present-day aerosol loading during boreal spring are investigated using the NASA finite volume General Circulation Model (fvGCM). Three-dimensional distributions of loadings of five species of tropospheric aerosols, i.e., sulfate, black carbon, organic carbon, soil dust, and sea salt are prescribed from outputs of the Goddard Ozone Chemistry Aerosol Radiation and Transport model (GOCART). The aerosol loadings are used to calculate the extinction coefficient, single scattering albedo, and asymmetric factor at eleven spectral wavelengths in the radiative transfer code. We find that aerosol-radiative forcing during boreal spring excites a wavetrain-like pattern in tropospheric temperature and geopotential height that emanates from Northern Africa, through Eurasia, to northeastern Pacific. Associated with the teleconnection is strong surface cooling over regions with large aerosol loading, i.e., China, India, and Africa. Low-to-mid tropospheric heating due to shortwave absorption is found in regions with large loading of dust (Northern Africa, and central East Asia), and black carbon (South and East Asia). In addition pronounced surface cooling is found over the Caspian Sea and warming over Eurasian and northeastern Asia, where aerosol loadings are relatively low. These warming and cooling are components of teleconnection pattern produced primarily by atmospheric heating from absorbing aerosols, i.e., dust from North Africa and.black carbon from South and East Asia. Effects of aerosols on atmospheric hydrologic cycle in the Asian monsoon region are also investigated. Results show that absorbing aerosols, i.e., black carbon and dust, induce large-scale upper-level heating anomaly over the Tibetan Plateau in April and May, ushering in an early onset of the Indian summer monsoon. Absorbing aerosols also enhance lower-level heating and anomalous ascent over northern India, intensifying the Indian monsoon. Overall, the aerosol-induced large-scale surface temperature cooling leads to a reduction of monsoon rainfall over the East Asia continent, and adjacent oceanic regions.

Lau, William K. M.↗