Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “controllable loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Joint Optimization for Transport and Bucket Loading Phases of Automated Wheel Loaders

This article investigates optimization of fuel-efficiency and productivity for automated wheel loaders. A control-oriented model for both the transport phase and bucket loading phase is proposed. Here, the vehicle model includes an automatic gear shift schedule that can be incorporated into the optimization problem. Based on the model, the multistage optimization problem is formulated to simultaneously consider all phases of a short cycle with physical constraints. Cycle time and fuel efficiency are used as the weighted performance indexes in a multiobjective cost function. Bucket fill factor is included as a constraint during the bucket loading phase. A nonlinear programming problem is created with collocation using MATLAB and CasADi. The optimization solver IPOPT solves the problem to obtain the optimal state and control trajectories, which can be used as a reference for automated wheel loaders or even as a driver advisory for human-driven wheel loaders.

42 ENGINEERING↗

Heliostat Consortium: Gap Analysis on Wind Load for Achieving a Fully Competitive Heliostat Industry

The Heliostat Consortium (HelioCon) Wind Load Subtask was initiated with the aim of bringing research work pertaining to wind load measurement, characterization, and prediction taking place across several tasks, including Advanced Manufacturing, Components and Controls, and Field Deployment. The cross-cutting wind load subtopic in the HelioCon roadmap report [1] highlighted standardized methods and tools that are needed for a more detailed understanding of the static and dynamic loads on a heliostat. This will enable cost reduction of wind-dependent heliostat components to avoid unnecessarily conservative, overly constrained designs and increase field efficiency/reliability, to reduce the risk of component failures due to high-wind events (>15 m/s). Gaps related to heliostat wind load include site characterization for wind measurements, critical load cases for heliostat design, turbulence impacts on heliostat tracking error, testing of heliostat array configurations, understanding spatial variation of maximum loads across the solar field, and heliostat field layout and operating strategies. The recommended highest-priority pathway as first steps taken by HelioCon to address these gaps are to develop site characterization guidelines for heliostat design and field load measurements.

Emes, Matthew (ORCID:0000000341474387)↗

Segmented Energy Routing for a Modular AC/DC Hybrid System

This article presents a modular ac/dc system with both distributed and centralized power ports for energy router (ER) applications. In each module of the described system, photovoltaic (PV) power generation units, battery-type energy storage (ES) units, and critical loads are connected to the cascaded H-bridge (CHB)-organized medium-voltage (MV) dc links, with fully distributed low-voltage (LV) dc power ports. Copies of modules share the centralized load bus and interact with an MV ac grid in parallel. Hybrid power port (HPO) assigns flexibility to the system but makes energy routings a necessity for stable operation. In this article, a segmented energy management strategy for the HPO-ER is proposed. In terms of the grid-side power transferring, the system ratings are intentionally designed to match significant power imbalance. Focally, a segmented energy management strategy is proposed to realize fully autonomous energy routing involving MV ac grid, distributed PV generations, distributed battery storages, and LV load. The system is proven to be stable using the derived impedance-based model considering the interaction between power blocks. The feasibility of the topology and control strategy is also verified through software simulation, laboratorial hardware prototype experiment, and hardware-in-the-loop (HIL) emulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synthetic residential load models for smart city energy management simulations

The ability to control tens of thousands of residential electricity customers in a coordinated manner has the potential to enact system-wide electric load changes, such as reduce congestion and peak demand, among other benefits. To quantify the potential benefits of demand-side management and other power system simulation studies (e.g. home energy management, large-scale residential demand response), synthetic load datasets that accurately characterize the system load are required. This study designs a combined top-down and bottom-up approach for modelling individual residential customers and their individual electric assets, each possessing their own characteristics, using time-varying queueing models. The aggregation of all customer loads created by the queueing models represents a known city-sized load curve to be used in simulation studies. The three presented residential queueing load models use only publicly available data. An open-source Python tool to allow researchers to generate residential load data for their studies is also provided. The simulation results presented consider the ComEd region (utility company from Chicago, IL) and demonstrate the characteristics of the three proposed residential queueing load models, the impact of the choice of model parameters, and scalability performance of the Python tool.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interleaved Cuk Converter Wave Energy System With Advanced Control and Grid Support Functions for Seamless Integration

This paper presents an innovative wave energy conversion system that integrates an interleaved Cuk converter with advanced nonlinear control for seamless grid integration. The system efficiently extracts power on the DC side using the interleaved Cuk converter, while an inverter manages power transfer to the grid or load on the AC side. A nonlinear control architecture, based on the Lyapunov energy function, ensures stable and optimal operation under varying wave conditions, effectively addressing the challenges of variability and unpredictability inherent in wave energy. The proposed system also incorporates features to enhance power quality and minimize losses, making it a robust solution for renewable energy integration. The system's effectiveness in harnessing wave energy and achieving smooth grid integration is validated through comprehensive computer simulations in MATLAB/Simulink, with case study results demonstrating its capabilities.

HYDRO ENERGY,TIDAL AND WAVE POWER↗

Comparison of Probabilistic Forecasts for Predictive Voltage Control

This paper explores predictive cooperative voltage control in distribution systems with highly variable sources such as photovoltaics (PV). The goal is to maintain the voltage profile within the limits despite the fluctuations due to sudden changes in solar power generation. The predictive voltage control method relies on probabilistic solar power and load forecasts to select the optimum Voltage Regulator (VR) taps appropriately. VR taps are selected to minimize the risk of voltage violation. A modified version of the IEEE 123 system is used as the case study. A 100% penetration of solar power is assumed for the distribution system with profiles for solar generation and loads added to the system. Three different probabilistic forecast models (Quantile Regression (QR), Gaussian distribution and volatility forecasting using Generalized Autoregressive Conditional Heteroskedasticity (GARCH)) are explored in this study. The results for the VR taps and Voltage Deviation Index (VDI) are compared to find the most effective forecast model.

Panamtash, Hossein↗

MiGRIDS

MiGRIDS is a software that models islanded microgrid power systems with different controls and components. For example, using load and resource data from a microgrid, you could model it with additional wind turbines, battery etc. You could also try out different dispatch schemes to see which one worked best. MiGRIDS is designed to help optimize the size and dispatch of grid components in a microgrid. While a grid connect feature is expected to be added in the future, islanded operation is the focus. Note that this is a basic implementation and more features and functionality (such as a GUI) are coming! MiGRIDS runs time-step energy balance simulations for different grid components and controls. In smaller microgrid environments, dispatch decisions are being made on the order of seconds. In order to fully capture their effect, this tool lets you run simulations on the order of seconds. The end result is a more realistic representation of what can be achieved by integrating different components and control strategies in a grid.

Morgan, Tawna↗

A hierarchical framework for aggregating grid-interactive buildings with thermal and battery energy storage

The behind-the-meter (BTM) thermal and battery energy storage can help improve energy efficiency, reduce energy costs, and enhance energy resilience, particularly in rural areas and for disadvantaged communities. Aggregating numerous BTM energy storage systems can act as a price influencer with a significant source of load shifting and peak demand reduction. An integrated and scalable control mechanism is required to effectively utilize energy storage systems and flexible building loads to maximize the economic benefits, considering various distribution system constraints. Here, this paper presents an innovative hierarchical coordination framework for energy storage and flexible load in buildings, considering various factors such as electricity prices, thermal comfort, and distribution system modeling and constraints. At the upper level, a distribution system operator optimizes the power flow to minimize its power procurement costs from the electricity wholesale market, while at the lower level, aggregators determine the optimal dispatch of battery and thermal energy storage systems in multiple buildings on behalf of end-users to minimize operating costs according to the power prices. These problems are solved using a game-theoretic approach through negotiations between the distribution system operator and aggregators as a bi-level decision model. Simulation case studies have been performed for a test distribution network with a number of building end-users using energy storage systems to quantify the performance of aggregators. The results demonstrate that the proposed strategy can reduce peak load for a reliable electricity distribution network while saving electricity bills for customers.

25 ENERGY STORAGE↗

Enhanced Performance of Silicon Anodes through Hybrid Surface Engineering

Silicon (Si) is a promising anode material for nextgeneration lithium-ion batteries (LIBs) due to its high theoretical capacity. However, Si-containing anodes typically suffer from unacceptably short lives because of the unrestricted growth of the solid electrolyte interphase (SEI). Here, in this study, hybrid surface coatings are developed to stabilize the SEI in high loading pure Si anodes using atomic and molecular layer deposition. The coatings, consisting of LiF paired with lithicone, create an ionically conductive surface that enhances the capacity retention, rate performance, and longevity. Careful binder selection helps demonstrate the full utility of the coatings by enabling high loading electrodes to cycle continuously at current densities of 1200 mA/g Si . Uncoated controls, in comparison, fail within just 10 cycles at lower loadings. X-ray photoelectron spectroscopy and electrochemical impedance spectroscopy are used to provide supporting evidence of the coating composition and efficacy. The data indicate that our lithicone coating is converted to Li 2 CO 3 upon cycling contributing to favorable LiF/Li 2 CO 3 interfaces that enhance the space-charge effect at the active material’s surface. When applied to electrodes made with thermally stable binders and increasingly higher loadings (approaching 5 mAh/cm 2 ), ion transport through the bulk electrode, rather than SEI growth, is shown to be the limiting factor. Furthermore, data suggests a favorable interaction between lithicone precursors and poly(acrylic acid) binders mitigates thermal decomposition at higher temperatures. The work presented here represents the successful realization of composite coatings containing LiF/Li 2 CO 3 components to stabilize high-loading Si anodes. This work helps inform advanced surface engineering strategies to achieve highly reversible, high-capacity Si anodes capable of fast charging for high-performance LIBs.

atomic layer deposition↗

Parallel Grid-Forming Inverter-Driven Black Start: Power-Hardware-in-the-Loop Validation: Preprint

With power systems encountering increasing deployment levels of inverter-based resources (IBRs), system restoration using grid-forming (GFM) IBRs has gained attention. Engineered to establish grid voltages in the absence of a stiff grid, black-start-capable GFM IBRs are expected to enhance power system resilience by playing a critical role in bottom-up system restoration. This paper experimentally studies the feasibility of the novel approach through power-hardware-in-the-loop (PHIL) testing and validation with a commercial GFM inverter. The PHIL test setup demonstrates an inverter-driven black start of a 5-MW unbalanced distribution feeder where two GFM inverters collectively black start the feeder: one is a commercial hardware GFM inverter interacting through the PHIL interface, and the other is a software GFM emulated by a real-time simulation with full electromagnetic transient (EMT) models. Both GFM inverters are equipped with negative-sequence voltage control to suppress the voltage imbalance resulting from the unbalanced loading, allowing us to study the dynamic interactions between the GFMs with their control parameters unknown. To evaluate the dynamic behavior of the GFM inverters under the entire black-start process, the EMT model of the distribution system details the transformer and motor dynamics to emulate their inrush and startup behaviors. It abstracts conventional grid-connected inverter dynamics, i.e., grid-following inverters. Oscilloscope measurements of the hardware GFM inverter are also presented for critical steps. Takeaways for further study and field deployment are provided.

grid-forming inverter↗

Modeling Offshore Wind Farm Performance in Coastal Low-Level Jets Using Coupled Mesoscale-Microscale Large Eddy Simulations

Accurately predicting wind farm reliability under complex offshore atmospheric conditions remains a key challenge, particularly during noncanonical meteorological events such as coastal low-level jets (LLJs). LLJs, characterized by strong nonmonotonic vertical shear and directional veer, depart significantly from the simplified inflow assumptions embedded in conventional design standards, low-fidelity engineering models, and microscale large eddy simulations of the atmospheric boundary layer. In this work, we use the virtual wind farm framework—an exascale, graphics processing unit–accelerated large eddy simulation platform coupled with high-fidelity aeroservoelastic turbine models and advanced mesoscale-microscale coupling via the ExaWind software stack—to investigate turbine responses under realistic LLJ forcing. Simulations are performed over the U.S. North Atlantic offshore domain with the use of meteorological inputs from New York State Energy Research and Development Authority buoy data, focusing on a representative LLJ case impacting the International Energy Agency 15 MW reference turbine. Our results show that LLJs can cause up to 50% power deficits in downstream turbine rows and significantly amplify low-speed shaft and tower loads through nonlinear coupling between complex inflow characteristics and turbine structural dynamics. Two primary mechanisms drive these load amplifications: (1) unique LLJ inflow features—including veer and vertical/lateral shear—and (2) the downstream evolution of the flow under stable thermal stratification, which suppresses turbulence mixing and alters wake recovery. These mechanisms produce streamwise variations in turbine loading not captured by standard hub height–based metrics or existing design load case (DLC) definitions. This study highlights the critical role of rotor-scale flow gradients in driving fatigue and system-level aeroelastic responses, challenging current DLC and control strategies. We advocate the integration of full-flow field, environment-aware wind inputs into load modeling and control algorithms. By leveraging exascale computing to resolve mesoscale-microscale coupling, this work lays the groundwork for next-generation offshore wind turbine design and operation in meteorologically complex marine environments.

17 WIND ENERGY↗

Efficient Thermal Processes Using Alternating Electromagnetic Field for Methodical and Selective Release of Hydrogen Isotopes

The controlled and selective release of hydrogen isotopes from Lanthanum-Nickel-Aluminum (LANA) materials was achieved using an alternating electromagnetic field (AEMF). Here, in the presence of the AEMF, the rate of desorption for D 2 was faster than for H 2 . In a closed system, compared to control experiments with helium, hydrogen-loaded LANA samples showed a significant increase in pressure which illustrates the desorption of hydrogen from the applied AEMF. An exponential increase in the hydrogen release rate was observed with increased AEMF strength. Additionally, hydrogen release from LANA confined in a subzero environment (-78°C) using an AEMF was demonstrated. These results demonstrate that the LANA material can be heated directly using alternating electromagnetic fields rather than indirectly to rapidly and selectively desorb hydrogen isotopes. The rapid response and difference in desorption kinetics for different hydrogen isotopes in the presence of the alternating electromagnetic fields provide a promising pathway for applications requiring controlled release of hydrogen and separation of its isotopes.

07 ISOTOPE AND RADIATION SOURCES↗

Off-policy deep reinforcement learning with automatic entropy adjustment for adaptive online grid emergency control

Electric overloading conditions and contingencies put modern power systems at risk of voltage collapse and blackouts. Load shedding is crucial to maintain voltage stability for grid emergency control. However, the rule- or model-based schemes rely on accurate dynamic system models and face considerable challenges in adapting to various operating conditions and uncertain event occurrences. Here, to address these issues, this paper proposes a novel deep reinforcement learning (DRL)-based voltage stability control algorithm with automatic entropy adjustment (AEA) for grid emergency control. Various dynamic network components for complex system operations are modeled to construct the DRL environment. An off-policy soft actor-critic architecture is developed to maximize the expected reward and policy entropy simultaneously. The AEA mechanism is proposed to facilitate the policy maximum entropy procedure, and the proposed method can automatically provide effective discrete and continuous actions against various fault scenarios. Our approach accomplishes high sampling efficiency, scalability, and auto-adaptivity of the control policies under high uncertainties. Comparative studies with the existing DRL-based control methods in IEEE benchmarks indicate salient performance improvement of the proposed method for dynamic system emergency control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design of Phase-Change Thermal Storage Device in a Heat Pump for Building Electric Peak Load Shaving: Preprint

Replacing carbon-intensive fossil fuel heating systems with electric heat pumps powered by renewables is a promising approach to decarbonize the building sector. However, one of the technical barriers of this approach is the large scale of heat demand, which will put excessive stress on the electricity grid. Integrating thermal energy storage (TES) into the heating systems can help alleviate this problem, by shifting thermal load and thus shaving peaks in the building electric load. Therefore, it is critical to understand how to design a thermal storage device in a heat pump for peak load shaving. In this study, we developed a numerical model for a cascaded vapor compression heat pump system integrating a phase change thermal storage device. This novel system can control the net thermal charging and discharging rate of the TES independently from the building's thermal load, which allows for precise control of electric power use. In the current study, we controlled the system to shave building electric peak load during a cold winter morning, and to charge TES during the relatively warm afternoon while still providing space heating. We used the model to evaluate the system performance with and without peak shaving. We also investigated the effect of PCM transition Tt on the peak reduction and electric energy saving potentials. The results show that peak shaving scheme effectively reduces the peak electric power consumption during a predefined discharge time window. When comparing to the no shaving case, for PCM Tt = 10 degrees C, the peak electric load reduction is 23.5%. When comparing to an air-source heat pump with back up electric heater, as Tt increases from 0 to 20 degrees C, the peak reduction increases from 46.1% to 50.9%. Integrating PCM Tt = 10 degrees C with peak shaving leads to the 45.5% of electric energy saving, which is the highest among the three transition temperatures.

electric energy saving↗

A digital twin based on OpenFAST linearizations for real-time load and fatigue estimation of land-based turbines

Monitoring a wind turbine requires intensive instrumentation, which would be too cost-prohibitive to deploy to an entire wind plant. This work presents a technique that uses readily available measurements to estimate signals that would otherwise require additional instrumentation. This study presents a digital twin concept with a focus on estimating wind speed, thrust, torque, tower-top position, and loads in the tower using supervisory control and data acquisition (SCADA) measurements. The model combines a linear state-space model obtained using OpenFAST linearizations, a wind speed estimator, and a Kalman filter algorithm that integrates measurements with the state model to perform state estimations. The measurements are: top acceleration, generator torque, pitch, and rotational speed. The article extends previous work that derived the linear state-space model using a different method. The new implementation, based on OpenFAST linearization capability, allows for a systematic extension of the method to more states, inputs, outputs, and to the offshore environment. Results from the two methods are compared, and the validation is made with additional measurements using the GE 1.5-MW turbine located at the National Renewable Energy Laboratory test site. Real-time damage equivalent loads of the tower bottom moment are estimated with an average accuracy of approximately 10%. Overall, the results from this proof of concept are encouraging, and further application of the model will be considered.

17 WIND ENERGY↗

Making Grid-interactive Efficient Buildings a “Win” for Both Customers and Utilities

Buildings account for more than 70% of U.S. electricity use and at least one-third of U.S. economy-wide CO2 emissions. Changing the timing and overall amount of electricity consumption in buildings would significantly reduce energy costs to consumers and facilitate the transition to a decarbonized economy. Grid-interactive efficient buildings (GEBs) incorporate energy efficiency, smart technologies, and active use of distributed energy resources (DERs) to provide these benefits. As the link between the customer and the power system, utilities are central to widespread deployment of GEBs. Yet, despite the significant cost savings and operational benefits of GEBs for utilities, deployment has remained limited. This paper explores emerging models for enabling utilities to facilitate GEB adoption. Building off foundational research conducted to develop the U.S. DOE’s A National Roadmap for Grid-Interactive Efficient Buildings, we describe the most novel recent examples of ways in which utilities and regulators have made demand-side innovation a win for both the customer and the utility. Emerging concepts include: (1) performance incentive mechanisms to align GEB deployment with utility financial motivations, (2) the use of subscription pricing (i.e., fixed monthly bills) to promote load flexibility and energy efficiency, (3) rate-basing utility-controlled behind-the-meter assets, and (4) coupling energy efficiency and load flexibility with electrification proposals to ensure that customer benefits are maximized. The paper concludes with a discussion about prospects for widespread GEB deployment and utilization by utilities, and how to scale efforts.

Satchwell, Andrew↗

Constant Frequency ZVS PWM Converter

In this paper, a simple yet novel buck or boost adaptive zero-voltage switching (ZVS) converter topology is proposed for soft switching pulse-width modulation (PWM) dc / dc converters. The converter is designed for the high switching frequency that can achieve high efficiency by reducing switching losses for the entire load range at low and high power. Besides, the output at the load terminals is maintained by a PWM signal at a fixed switching frequency, a phase shift signal between converter ports (legs) controls the system circulating current in order to provide the ZVS condition in all load conditions. With the proposed controller, the converter, thus, is suitable for high switching frequency and high-power applications with the small volume. The proposed dc / dc converter operation is analyzed, designed, and confirmed by simulation results for 240 V input, 400 V / 5 A output, and 200 kHz operating frequency at full load.

Asa, Erdem↗

Parametric and sensitivity analysis of a PCM-integrated wall for optimal thermal load modulation in lightweight buildings

Load modulation in buildings is becoming increasingly important due to growing disparity in energy demand during peak and off-peak hours. Integrating phase change material (PCM) in building envelopes and using a controlled precooling strategy can provide substantial thermal load modulation; however, it may greatly increase the total energy use. Previous studies have employed PCM in building envelopes primarily for energy savings and, to some extent, peak load shedding and shifting. However, the load modulation capacity of a PCM-integrated envelope has not been well explored in the literature. In this study, we perform an extensive parametric and sensitivity analysis on PCM-integrated lightweight building walls and examine the combinatory effects of various PCM parameters on thermal load modulation and wall-related heat gains in buildings. Using numerical simulations, we investigate eight PCM parameters: PCM location in the wall, transition temperature, thickness, latent heat, transition range, density, specific heat, and thermal conductivity. Here, we evaluate their impact and relative importance to achieve maximum load modulation in buildings without compromising occupants’ thermal comfort or total energy use. The results show that the optimized PCM proposed in this study can completely invert the transient heat gain profile of the wall, providing up to 70% reduction of wall-related heat gain during peak hours without a major increase in the cumulative heat gain.

42 ENGINEERING↗