Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “conservative loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

The 100 kW space station

Solar array power systems for the space construction base are discussed. Nickel cadmium and nickel hydrogen batteries are equally attractive relative to regenerative fuel cell systems at 5 years life. Further evaluation of energy storage system life (low orbit conditions) is required. Shuttle and solid polymer electrolyte fuel cell technology appears adequate; large units (approximately four times shuttle) are most appropriate and should be studied for a 100 KWe SCB system. A conservative NiH2 battery DOD (18.6%) was elected due to lack of test data and offers considerable improvement potential. Multiorbit load averaging and reserve capacity requirements limit nominal DOD to 30% to 50% maximum, independent of life considerations.

Mckhann, G.↗

Computerized energy analysis for the Mars operations support building

A detailed computerized building load simulation of the Operations Support Building at the Mars Deep Space Station, Goldstone, California is described. Five energy conservation suggestions were investigated prior to implementation. The results showed that cost savings of about 16 percent of present energy costs are possible.

Yung, C. S.↗

In-phase and out-of-phase axial-torsional fatigue behavior of Haynes 188 at 760 C

Isothermal, in-phase and out-of-phase axial-torsional fatigue experiments have been conducted at 760 C on uniform gage section, thin-walled tubular specimens of a wrought cobalt-base superalloy, Haynes 188. Test-control and data acquisition were accomplished with a minicomputer. Fatigue lives of the in- and out-of-phase axial-torsional fatigue tests have been estimated with four different multiaxial fatigue life prediction models that were developed primarly for predicting axial-torsional fatigue lives at room temperature. The models investigated were: (1) the von Mises equivalent strain range; (2) the Modified Multiaxiality Factor Approach; (3) the Modified Smith-Watson-Topper Parameter; and (4) the critical shear plane method of Fatemi, Socie, and Kurath. In general, life predictions by the von Mises equivalent strain range model were within a factor of 2 for a majority of the tests and the predictions by the Modified Multiaxiality Factor Approach were within a factor of 2, while predictions of the Modified Smith-Watson-Topper Parameter and of the critical shear plane method of Fatemi, Socie, and Kurath were unconservative and conservative, respectively, by up to factors of 4. In some of the specimens tested under combined axial-torsional loading conditions, fatigue cracks initiated near extensometer indentations. Two design modifications have been proposed to the thin-walled tubular specimen to overcome this problem.

Kalluri, Sreeramesh↗

High Resolution Visualization Applied to Future Heavy Airlift Concept Development and Evaluation

This paper explores the use of high resolution 3D visualization tools for exploring the feasibility and advantages of future military cargo airlift concepts and evaluating compatibility with existing and future payload requirements. Realistic 3D graphic representations of future airlifters are immersed in rich, supporting environments to demonstrate concepts of operations to key personnel for evaluation, feedback, and development of critical joint support. Accurate concept visualizations are reviewed by commanders, platform developers, loadmasters, soldiers, scientists, engineers, and key principal decision makers at various stages of development. The insight gained through the review of these physically and operationally realistic visualizations is essential to refining design concepts to meet competing requirements in a fiscally conservative defense finance environment. In addition, highly accurate 3D geometric models of existing and evolving large military vehicles are loaded into existing and proposed aircraft cargo bays. In this virtual aircraft test-loading environment, materiel developers, engineers, managers, and soldiers can realistically evaluate the compatibility of current and next-generation airlifters with proposed cargo.

FordCook, A. B.↗

Quantifying Changes in Building Electricity Use, with Application to Demand Response

We present methods for analyzing commercial and industrial facility 15-minute-interval electric load data. These methods allow building managers to better understand their facility's electricity consumption over time and to compare it to other buildings, helping them to ask the right questions to discover opportunities for demand response, energy efficiency, electricity waste elimination, and peak load management. We primarily focus on demand response. Methods discussed include graphical representations of electric load data, a regression-based electricity load model that uses a time-of-week indicator variable and a piecewise linear and continuous outdoor air temperature dependence, and the definition of various parameters that characterize facility electricity loads and demand response behavior. In the future, these methods could be translated into easy-to-use tools for building managers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Equivalence in Ventilation and Indoor Air Quality

We ventilate buildings to provide acceptable indoor air quality (IAQ). Ventilation standards (such as American Society of Heating, Refrigerating, and Air-Conditioning Enginners [ASHRAE] Standard 62) specify minimum ventilation rates without taking into account the impact of those rates on IAQ. Innovative ventilation management is often a desirable element of reducing energy consumption or improving IAQ or comfort. Variable ventilation is one innovative strategy. To use variable ventilation in a way that meets standards, it is necessary to have a method for determining equivalence in terms of either ventilation or indoor air quality. This study develops methods to calculate either equivalent ventilation or equivalent IAQ. We demonstrate that equivalent ventilation can be used as the basis for dynamic ventilation control, reducing peak load and infiltration of outdoor contaminants. We also show that equivalent IAQ could allow some contaminants to exceed current standards if other contaminants are more stringently controlled.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Use of PCM-Enhanced Insulations in the Building Envelope

A phase change material (PCM) alters the heat flow across the building envelope by absorbing and releasing heat in response to cycling ambient temperatures. The benefit of a PCM is reduction in heating and cooling loads and in many cases a shift in peak-load demands and the time of day of the peak load. Ambient or interior temperature cycling past the phase change temperature range is necessary for the PCM to function. The design of a PCM application requires selection of material, identification of PCM location and bounding thermal resistances, and specification of the amount of PCM to be used. PCM can be distributed in an insulation or building material or packaged for localized application. This paper describes small-scale laboratory testing, large- scale laboratory testing, and field studies undertaken to evaluate the energy savings potential for PCM in the building envelope.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Vehicle Thermal Management for Advanced Vehicle Propulsion Technologies

A critical element to the success of new propulsion technologies that enable reductions in fuel use is the integration of component thermal management technologies within a viable vehicle package. Vehicle operation requires vehicle thermal management systems capable of balancing the needs of multiple vehicle systems that may require heat for operation, require cooling to reject heat, or require operation within specified temperature ranges. As vehicle propulsion transitions away from a single form of vehicle propulsion based solely on conventional internal combustion engines (ICEs) toward a wider array of choices including more electrically dominant systems such as plug-in hybrid electric vehicles (PHEVs), new challenges arise associated with vehicle thermal management. As the number of components that require active thermal management increase, so do the costs in terms of dollars, weight, and size. Integrated vehicle thermal management is one pathway to address the cost, weight, and size challenges. The integration of the power electronics and electric machine (PEEM) thermal management with other existing vehicle systems is one path for reducing the cost of electric drive systems. This work demonstrates techniques for evaluating and quantifying the integrated transient and continuous heat loads of combined systems incorporating electric drive systems that operate primarily under transient duty cycles, but the approach can be extended to include additional steady-state duty cycles typical for designing vehicle thermal management systems of conventional vehicles. The work compares opportunities to create an integrated low temperature coolant loop combining the power electronics and electric machine with the air conditioning system in contrast to a high temperature system integrated with the ICE cooling system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energetic Potential for Demand Response in Detached Single Family Homes in Austin, TX

This study builds a generalized tool to quantify the maximum peak load reduction achievable with residential demand response and distributed energy resources (DERs). The tool is demonstrated by using empirical energy usage data from detached single family households within the service territory of Austin Energy - the local municipal utility in Austin, TX. The demand response optimization algorithm shifts energy usage of four controllable, high-consumption residential devices to off-peak hours: HVAC (heating, ventilation, and air conditioning) systems, electric water heaters, electric vehicles, and pool pumps. In addition, rooftop solar generation on individual residences is considered to reduce net load to the utility, and an energy storage system optimization model performing energy arbitrage further reduces peak demand. Results from the aggregate demand response and battery optimization study indicate that peak demand for the 2017 summer peak in Austin Energy could have been reduced by 26 MW or 2.9%. Here, by considering the combined effect of controllable consumer loads, solar generation, and energy storage systems, this study highlights the potential of strategic demand response and energy arbitrage to reduce peak demand at the distribution level.

14 SOLAR ENERGY↗

Investigating Response from Attached and Separated Flow Excitations on a Real Launch Vehicle using SEA

Statistical Energy Analysis (SEA) response has been fairly well anchored to test observations for Diffuse Acoustic Field (DAF) loading by others. Meanwhile, not many examples can be found in the literature anchoring the SEA vehicle panel response results to Turbulent Boundary Layer (TBL) fluctuating pressure excitations. This deficiency is especially true for supersonic trajectories such as those required by this nation s launch vehicles. Response and excitation data from vehicle flight measurements gathered during the development flight era of the Space Shuttle have been used in a trial to assess the sensitivity of response analysis to certain known and unknown parameters of the flight. This assessment compares vibration response predictions for TBL excitations produced by the SEA tool to flight measurements. A secondary, but perhaps more important objective, is to provide more clarity concerning the accuracy and conservatism that can be expected from response estimates to TBL-excited vehicle models in SEA. What range of parameters must be included in such an analysis in order to land on the conservative side in response predictions? What is the variability produced in the results with changes in these parameters? The TBL fluid structure loading model used for this study is provided from the SEA module of the commercial code VA One.

Harrison, Phil↗

Investigating Response from Turbulent Boundary Layer Excitations on a Real Launch Vehicle using SEA

Statistical Energy Analysis (SEA) response has been fairly well anchored to test observations for Diffuse Acoustic Field (DAF) loading by others. Meanwhile, not many examples can be found in the literature anchoring the SEA vehicle panel response results to Turbulent Boundary Layer (TBL) fluctuating pressure excitations. This deficiency is especially true for supersonic trajectories such as those required by this nation s launch vehicles. Space Shuttle response and excitation data recorded from vehicle flight measurements during the development flights were used in a trial to assess the capability of the SEA tool to predict similar responses. Various known/measured inputs were used. These were supplemented with a range of assumed values in order to cover unknown parameters of the flight. This comparison is presented as "Part A" of the study. A secondary, but perhaps more important, objective is to provide more clarity concerning the accuracy and conservatism that can be expected from response estimates of TBL-excited vehicle models in SEA (Part B). What range of parameters must be included in such an analysis in order to land on the conservative side in response predictions? What is the sensitivity of changes in these input parameters on the results? The TBL fluid structure loading model used for this study is provided by the SEA module of the commercial code VA One.

Harrison, Phillip↗

Solar Cruiser TRAC Boom Development

The TRAC boom studied is a 30 meter, high-aspect ratio and highly nonlinear structural element planned for the NASA Solar Cruiser spacecraft where it would serve as the solar sail’s skeletal system designed to deploy the packaged reflective sail membrane as well as support operational sail tension loads for flight. Key design drivers for this boom are understanding and characterizing load-deformation behavior and quantifying buckling performance–under flight conditions (zero gravity). Knowing that the full-scale solar sail system cannot be feasibly tested for flight conditions under Earth’s gravity, a building block approach is methodically followed to verify finite element analysis (FEA) predictions and to evolve the finite element model (FEM) accordingly, beginning with the lowest level complexity to match global elastic behavior to the highest level complexity to bound theoretical responses under conservative expected flight conditions. Although the testing campaign for the TRAC boom has not developed yet to produce a full-scale test data point that loads the boom to failure, the fidelity of simulations have evolved with success and warrant further interest and work on this high-aspect ratio, but highly stable, deployable structural boom.

Lee Nguyen↗

THE CO2 ABATEMENT POTENTIAL OF CALIFORNIA'S MID-SIZED COMMERCIAL BUILDINGS

The Ernest Orlando Lawrence Berkeley National Laboratory (LBNL) is working with the California Energy Commission (CEC) todetermine the potential role of commercial sector distributed generation (DG) with combined heat and power (CHP) capability deployment in greenhouse gas emissions (GHG) reductions. CHP applications at large industrial sites are well known, and a large share of their potential has already been harvested. In contrast, relatively little attention has been paid to the potential of medium-sized commercial buildings, i.e. ones with peak electric loads ranging from 100 kW to 5 MW. We examine how this sector might implement DG with CHP in cost minimizing microgrids that are able to adopt and operate various energy technologies, such as solar photovoltaics (PV), on-site thermal generation, heat exchangers, solar thermal collectors, absorption chillers, and storage systems. We apply a mixed-integer linear program (MILP) that minimizes a site?s annual energy costs as its objective. Using 138 representative mid-sized commercial sites in California (CA), existing tariffs of three major electricity distribution ultilities, and performance data of available technology in 2020, we find the GHG reduction potential for this CA commercial sector segment, which represents about 35percent of total statewide commercial sector sales. Under the assumptions made, in a reference case, this segment is estimated to be capable of economically installing 1.4 GW of CHP, 35percent of the California Air Resources Board (CARB) statewide 4 GW goal for total incremental CHP deployment by 2020. However, because CARB?s assumed utilization is far higher than is found by the MILP, the adopted CHP only contributes 19percent of the CO2 target. Several sensitivity runs were completed. One applies a simple feed-in tariff similar to net metering, and another includes a generous self-generation incentive program (SGIP) subsidy for fuel cells. The feed-in tariff proves ineffective at stimulating CHP deployment, while the SGIP buy down is more powerful. The attractiveness of CHP varies widely by climate zone and service territory, but in general, hotter inlandareas and San Diego are the more attractive regions because high cooling loads achieve higher equipment utilization. Additionally, large office buildings are surprisingly good hosts for CHP, so large office buildings in San Diego and hotter urban centers emerge as promising target hosts. Overall the effect on CO2 emissions is limited, never exceeding 27 percent of the CARB target. Nonetheless, results suggest that the CO2 emissions abatement potential of CHP in mid-sized CA buildings is significant, and much more promising than is typically assumed.

03 NATURAL GAS↗

Performance evaluation of a metamaterial-based new cool roof using improved Roof Thermal Transfer Value model

A new cool roof with potential to generate significant energy savings in buildings has been developed from a metamaterial film named as RadiCold. Considering that the RadiCold film has unique optical and thermal characteristics and the current Roof Thermal Transfer Value model neglecting the effect of roof thermal mass that may lead to overestimating the cooling load from roofs, this work developed an improved Roof Thermal Transfer Value model and validated the model for both RadiCold cool roof and traditional roofing structures. Data from the reduced-size model building experiments showed that the improved Roof Thermal Transfer Value model can accurately describe the heat gains or losses via the roofs. Under real-world weather conditions in the United States (Tucson AZ, Los Angeles, CA, and Orlando FL), the improved Roof Thermal Transfer Value model has been applied to three types of roof exterior finishing: shingle, Thermoplastic Polyolefin (a cool roof material) and RadiCold. In a typical meteorology year, the modeling results show that the shingle and Thermoplastic Polyolefin roof transfer 78.9–294.1 kWh/(m 2 ·yr) and 8.5–128.2 kWh/(m 2 ·yr) of heat into the building space, respectively, but the RadiCold cool roof dissipates 137.6–268.7 kWh/(m 2 ·yr) of heat from the building space to outdoor environment (e.g., sky). The cooling load reduction from utilizing RadiCold cool roof results in cooling electricity savings of 113.0–143.9 kWh/(m 2 ·yr) compared to the shingle roof and 88.0–92.4 kWh/(m2·yr) compared to the Thermoplastic Polyolefin roof for the three analyzed locations with an assumed air conditioning system’s coefficient of performance of 3.0.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Recovery Act: Adaptive Environmentally Contained Power and Cooling IT Infrastructure for the Data Center (Final Technical Report)

The objectives of this program were to research and develop a fully enclosed Information Technology (IT) rack system for 100 kilowatts (KW) of IT load that provides its own internal power and cooling with High Voltage Alternating Current (HVAC defined as 480 volt) and chilled water as the primary inputs into the system and accepts alternative energy power sources such as wind and solar. For maximum efficiency, internal power to the IT equipment uses distributed High Voltage Direct Current power (HVDC defined as 360-380 volt) from the power source to the IT loads. The management scheme aggressively controls energy use to insure the best utilization of available power and cooling resources. The solution incorporates internal active management controls that not only optimizes the system environment for the given dynamic IT loads and changing system conditions, but also interfaces with data center Building Management Systems (BMS) to provide a complete end-to-end view of power and cooling chain. This technology achieves the goal of a Power Usage Effectiveness (PUE) of 1.25, resulting in a 38% reduction in the total amount of energy needed to support a 100KW IT load compared to current data center designs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Strategy Guideline. Proper Water Heater Selection

This Strategy Guideline on proper water heater selection was developed by the Building America team Alliance for Residential Building Innovation to provide step-by-step procedures for evaluating preferred cost-effective options for energy efficient water heater alternatives based on local utility rates, climate, and anticipated loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗