Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computerized procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Localised distributions and criteria for correctness in complex Langevin dynamics

Complex Langevin dynamics can solve the sign problem appearing in numerical simulations of theories with a complex action. In order to justify the procedure, it is important to understand the properties of the real and positive distribution, which is effectively sampled during the stochastic process. In the context of a simple model, we study this distribution by solving the Fokker–Planck equation as well as by brute force and relate the results to the recently derived criteria for correctness. We demonstrate analytically that it is possible that the distribution has support in a strip in the complexified configuration space only, in which case correct results are expected. -- Highlights: •Characterisation of the equilibrium distribution sampled in complex Langevin dynamics. •Connection between criteria for correctness and breakdown. •Solution of the Fokker–Planck equation in the case of real noise. •Analytical determination of support in complexified space.

97 MATHEMATICS AND COMPUTING↗

Conserved Killing charges of quadratic curvature gravity theories in arbitrary backgrounds

We extend the Abbott-Deser-Tekin procedure of defining conserved quantities of asymptotically constant-curvature spacetimes, and give an analogous expression for the conserved charges of geometries that are solutions of quadratic curvature gravity models in generic D dimensions and that have arbitrary asymptotes possessing at least one Killing isometry. We show that the resulting charge expression correctly reduces to its counterpart when the background is taken to be a space of constant curvature and, moreover, is background gauge invariant. As applications, we compute and comment on the energies of two specific examples: the three-dimensional Lifshitz black hole and a five-dimensional companion of the first, whose energy has never been calculated before.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characteristics Analysis of SGTR accidents under the Shutdown Conditions

The Steam Generator Tube Rupture (SGTR) accident is one of design basis accidents that could result in undesirable radiation release as it bypasses the containment. According to Ref. [1], SGTRs have been experienced in several nuclear power plants and Ulchin 4 of Korea is one of them. Basically, SGTR analysis assumes that it occurs at full power, the SGTR at Ulchin 4 in 2002, was in the shutdown condition. Therefore, the transient behavior was different from the cases in full power conditions and especially, the effectiveness of Emergency Operating Procedure (EOP) needs to be checked if it is also applicable to the shutdown conditions, because EOP is prepared for full power conditions. In this paper, we set up a MARS-KS code model for Ulchin 4 unit and simulated the SGTR accident for benchmarking the model to the actual plant behavior during the accident. And then, several case studies were done to investigate the consequence of SGTR and the effectiveness of the EOP, focusing on the amount of the primary to secondary discharge flow which was influenced by operator actions. At the end, we'll discuss about the EOP for the shutdown conditions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Radiation Exposure of Abdominal Cone Beam Computed Tomography

PurposeTo evaluate patients radiation exposure of abdominal C-arm cone beam computed tomography (CBCT).MethodsThis prospective study was approved by the institutional review board; written, informed consent was waived. Radiation exposure of abdominal CBCT was evaluated in 40 patients who underwent CBCT during endovascular interventions. Dose area product (DAP) of CBCT was documented and effective dose (ED) was estimated based on organ doses using dedicated Monte Carlo simulation software with consideration of X-ray field location and patients’ individual body weight and height. Weight-dependent ED per DAP conversion factors were calculated. CBCT radiation dose was compared to radiation dose of procedural fluoroscopy. CBCT dose-related risk for cancer was assessed.ResultsMean ED of abdominal CBCT was 4.3 mSv (95 % confidence interval [CI] 3.9; 4.8 mSv, range 1.1–7.4 mSv). ED was significantly higher in the upper than in the lower abdomen (p = 0.003) and increased with patients’ weight (r = 0.55, slope = 0.045 mSv/kg, p < 0.001). Radiation exposure of CBCT corresponded to the radiation exposure of on average 7.2 fluoroscopy minutes (95 % CI 5.5; 8.8 min) in the same region of interest. Lifetime risk of exposure related cancer death was 0.033 % or less depending on age and weight.ConclusionsMean ED of abdominal CBCT was 4.3 mSv depending on X-ray field location and body weight.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pulmonary Arteriovenous Malformations Embolized Using a Micro Vascular Plug System: Technical Note on a Preliminary Experience

AIMTo report our preliminary experience using a Micro Vascular Plug (MVP) deployed through a 2.8Fr micro-catheter for the treatment of pulmonary arteriovenous malformations (PAVMs) in a cohort of patients affected by Hereditary Haemorrhagic Telangiectasia (HHT).Materials and MethodsFour consecutive female patients (mean age 38.0 years; range 25–55 years) with PAVMs diagnosed on echocardiogram/bubble test and contrast-enhanced CT (CECT) underwent MVP embolization. One patient was symptomatic with recent transient ischaemic attack. Follow-up was undertaken at 1-month post-procedure with CECT to assess PAVMs permeability and MVP positioning and at 1-, 6-, and 12-month post-procedure, with echocardiography/bubble test and standard neurological history, to confirm absence of right-to-left shunts and recurrent symptoms.ResultsEight PAVMs were treated in 4 patients over 5 interventional sessions (mean 1.6 PAVMs per session). All PAVMs were simple, with mean feeding artery diameter of 4.25 mm. Eight 6.5 mm MVPs were deployed in total (one per lesion). Technical success was 100%. Mean procedural time and patient dose per session were 70 min (range 40–70 min) and 53418 mGy.cm{sup 2} (range 6113–101628 mGy.cm{sup 2}), respectively. No signs of reperfusion neither of MPV migration were noted at 1-month CECT follow-up. At early follow-up (mean 3.75 months; range 1–12 months), clinical success was 100% with no evidence of recurrent right-to-left shunt, and no neurological symptoms. No immediate or late complications were observed.ConclusionsMVP embolization of PAVMs appears technically feasible, safe, and effective at early follow-up. Further prospective studies are required to confirm long-term safety and efficacy of this promising technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-G-18A-05: Cone-Beam CT Reconstruction with Deformed Prior Image

Purpose: Prior image can be incorporated into image reconstruction process to improve the quality of on-treatment cone-beam CT (CBCT) from sparseview or low-dose projections. However, the deformation between the prior image and on-treatment CBCT are not considered in current prior image based reconstructions (e.g., prior image constrained compressed sensing (PICCS)). The purpose of this work is to develop a deformed-prior-imagebased- reconstruction strategy (DPIR) to address the mismatch problem between the prior image and target image. Methods: The deformed prior image is obtained by a projection based registration approach. Specifically, the deformation vector fields (DVF) used to deform the prior image is estimated through matching the forward projection of the prior image and the measured on-treatment projection. The deformed prior image is then used as the prior image in the standard PICCS algorithm. Simulation studies on the XCAT phantom was conducted to evaluate the performance of the projection based registration procedure and the proposed DPIR strategy. Results: The deformed prior image matches the geometry of on-treatment CBCT closer as compared to the original prior image. Using the deformed prior image, the quality of the image reconstructed by DPIR from few-view projection data is greatly improved as compared to the standard PICCS algorithm. The relative image reconstruction error is reduced to 11.13% in the proposed DPIR from 17.57% in the original PICCS. Conclusion: The proposed DPIR approach can solve the mismatch problem between the prior image and target image, which overcomes the limitation of the original PICCS algorithm for CBCT reconstruction from sparse-view or low-dose projections.

60 APPLIED LIFE SCIENCES↗

Beyond Annulus Size: Imaging for TAVR Planning

Purpose of Review: The aim of this article is to review the role of imaging in pre-procedural assessment prior to transcatheter aortic valve replacement (TAVR)—with a focus on relevant anatomic findings apart from the size of the aortic annulus. Recent Findings: Pre-procedure imaging prior to TAVR heavily emphasizes assessment of the aortic annulus for appropriate valve sizing, with computed tomography angiography (CTA) emerging as the test of choice due to its ability to assess not only the aortic annulus but also the thoracoabdominal aorta and peripheral vasculature. Some patients with underlying kidney disease may be at increased risk of renal dysfunction following contrast-enhanced CTA; however, alternate imaging techniques can be performed to mitigate this risk such as magnetic resonance imaging. Summary: Familiarity with underlying anatomic variability and pathology relevant to TAVR implantation in addition to annulus size, as well as imaging approaches in patients with renal dysfunction, will allow radiologists to better contribute to multidisciplinary discussion for potential TAVR candidates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A simple grand canonical approach to compute the vapor pressure of bulk and finite size systems

In this article we introduce a simple grand canonical screening (GCS) approach to accurately compute vapor pressures from molecular dynamics or Monte Carlo simulations. This procedure entails a screening of chemical potentials using a conventional grand canonical scheme, and therefore it is straightforward to implement for any kind of interface. The scheme is validated against data obtained from Gibbs ensemble simulations for water and argon. Then, it is applied to obtain the vapor pressure of the coarse-grained mW water model, and it is shown that the computed value is in excellent accord with the one formally deduced using statistical thermodynamics arguments. Finally, this methodology is used to calculate the vapor pressure of a water nanodroplet of 94 molecules. Interestingly, the result is in perfect agreement with the one predicted by the Kelvin equation for a homogeneous droplet of that size.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A BAYESIAN METHOD FOR THE ANALYSIS OF THE DUST EMISSION IN THE FAR-INFRARED AND SUBMILLIMETER

We present a method, based on Bayesian statistics, to fit the dust emission parameters in the far-infrared and submillimeter wavelengths. The method estimates the dust temperature and spectral emissivity index, plus their relationship, properly taking into account the statistical and systematic uncertainties. We test it on three sets of simulated sources detectable by the Herschel Space Observatory in the PACS and SPIRE spectral bands (70-500 {mu}m), spanning over a wide range of dust temperatures. The simulated observations are a one-component interstellar medium and two two-component sources, both warm (H II regions) and cold (cold clumps (CCs)). We first define a procedure to identify the better model, then we recover the parameters of the model and measure their physical correlations by means of a Markov Chain Monte Carlo algorithm adopting multi-variate Gaussian priors. In this process, we assess the reliability of the model recovery and of parameter estimation. We conclude that the model and parameters are properly recovered only under certain circumstances and that false models may be derived in some cases. We applied the method to a set of 91 starless CCs in an interarm region of the Galactic plane with low star formation activity, observed by Herschel in the Hi-GAL survey. Our results are consistent with a temperature-independent spectral index.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-296: Modulated Therapy Down Under: A Survey of IMRT & VMAT Physics Practice in Australia and New Zealand

Purpose: A comprehensive survey of Australasian radiation oncology physics departments was undertaken to capture a snapshot of current usage, commissioning and QA practices for intensity-modulated therapies. Methods: An online survey was developed and advertised to Australian and New Zealand radiation oncology physicists through the local college (ACPSEM) in April 2015. The survey consisted of 147 questions in total, covering IMRT, VMAT and Tomotherapy, and details specific to different treatment planning systems. Questions captured detailed information on equipment, policies and procedures for the commissioning and QA of each treatment technique. Results: 41 partial or complete responses were collected, representing 59 departments out of the 78 departments operational. 137 and 84 linacs from these departments were using IMRT and VMAT respectively, from a total 150 linacs. 100% and 78% of respondents were treating with IMRT and VMAT respectively. There are at least 8 different treatment planning systems being used for IMRT or VMAT, and large variations in all aspects of QA policies and procedures. 29 responses indicated 72 methods routinely used for pre-treatment QA, when breaking down by device and analysis type. Similar numbers of departments use field-by-field analysis compared to composite analysis (56% to 44%) while a majority use true gantry angle delivery compared to fixed gantry at 0° (72% to 28%). 19 different implementations of gamma index analysis parameters were reported from 33 responses. A follow-up one-day workshop to highlight the results, discuss the role of QA and share equipment-specific knowledge across users was conducted in November 2015. Conclusion: While IMRT and VMAT are almost universally available in Australasia, large variations in practice indicate a need for national or consensus guidelines.

60 APPLIED LIFE SCIENCES↗

Development of a Method for Measurement of Photonuclear-Reaction Cross Sections with the Aid of Simulated Quasimonoenergetic-Photon Spectra

A procedure for measuring photonuclear-reaction cross sections by employing the method of quasimonochromatization of the bremsstrahlung photon spectrum is developed. This procedure permits determining reaction cross sections via measuring the reaction yield at three fixed values of the electron energy. The procedure is equivalent to measuring the cross section in question for quasimonochromatic photons. Bremsstrahlung-photon spectra are obtained using state-of-the-art simulation means involving the GEANT4 code as applied to a specific experiment with allowance for its geometry, target thicknesses, electron-beam parameters, etc. The results obtained by simulating quasimonochromatic distributions of bremsstrahlung photons are presented for experiments at the LUE-8-5 linear electron accelerator of Institute for Nuclear Research (Moscow, Russian Academy of Sciences). These results are found to be in good agreement with the experimental energy distribution of the cross section for the reaction {sup 111}Cd(γ, γ') in the energy range between 5 and 8 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Patient Positioning Based on a Radioactive Tracer Implanted in Patients With Localized Prostate Cancer: A Performance and Safety Evaluation

Purpose: To evaluate the performance and safety of a radiation therapy positioning system (RealEye) based on tracking a radioactive marker (Tracer) implanted in patients with localized prostate cancer. Methods and Materials: We performed a single-arm multi-institutional trial in 20 patients. The iridium-192 ({sup 192}Ir)-containing Tracer was implanted in the patient together with 4 standard gold seed fiducials. Patient prostate-related symptoms were evaluated with the International Prostate Symptom Score (IPSS) questionnaire. Computed tomography (CT) was performed for treatment planning, during treatment, and after treatment to evaluate the migration stability of the Tracer. At 5 treatment sessions, cone beam CT was performed to test the positioning accuracy of the RealEye. Results: The Tracer was successfully implanted in all patients. No device or procedure-related adverse events occurred. Changes in IPSS scores were limited. The difference between the mean change in Tracer-fiducial distance and the mean change in fiducial-fiducial distance was -0.39 mm (95% confidence interval [CI] upper boundary, -0.22 mm). The adjusted mean difference between Tracer position according to RealEye and the Tracer position on the CBCT for all patients was 1.34 mm (95% CI upper boundary, 1.41 mm). Conclusions: Implantation of the Tracer is feasible and safe. Migration stability of the Tracer is good. Prostate patients can be positioned and monitored accurately by using RealEye.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

GRAVITATIONAL WAVE SIGNATURES OF HYPERACCRETING COLLAPSAR DISKS

By performing two-dimensional special relativistic (SR) magnetohydrodynamic simulations, we study possible signatures of gravitational waves (GWs) in the context of the collapsar model for long-duration gamma-ray bursts. In our SR simulations, the central black hole is treated as an absorbing boundary. By doing so, we focus on the GWs generated by asphericities in neutrino emission and matter motions in the vicinity of the hyperaccreting disks. We compute nine models by adding initial angular momenta and magnetic fields parametrically to a precollapse core of a 35 M{sub Sun} progenitor star. As for the microphysics, a realistic equation of state is employed and the neutrino cooling is taken into account via a multi-flavor neutrino leakage scheme. To accurately estimate GWs produced by anisotropic neutrino emission, we perform a ray-tracing analysis in general relativity by a post-processing procedure. By employing a stress formula that includes contributions from both magnetic fields and SR corrections, we also study the effects of magnetic fields on the gravitational waveforms. We find that the GW amplitudes from anisotropic neutrino emission show a monotonic increase with time, whose amplitudes are much larger than those from matter motions of the accreting material. We show that the increasing trend of the neutrino GWs stems from the excess of neutrino emission in the direction near parallel to the spin axis illuminated from the hyperaccreting disks. We point out that a recently proposed future space-based interferometer like Fabry-Perot-type DECIGO would permit the detection of these GW signals within Almost-Equal-To 100 Mpc.

79 ASTRONOMY AND ASTROPHYSICS↗

MO-D-213-02: Quality Improvement Through a Failure Mode and Effects Analysis of Pediatric External Beam Radiotherapy

Purpose: To conduct a failure mode and effects analysis (FMEA) as per AAPM Task Group 100 on clinical processes associated with teletherapy, and the development of mitigations for processes with identified high risk. Methods: A FMEA was conducted on clinical processes relating to teletherapy treatment plan development and delivery. Nine major processes were identified for analysis. These steps included CT simulation, data transfer, image registration and segmentation, treatment planning, plan approval and preparation, and initial and subsequent treatments. Process tree mapping was utilized to identify the steps contained within each process. Failure modes (FM) were identified and evaluated with a scale of 1–10 based upon three metrics: the severity of the effect, the probability of occurrence, and the detectability of the cause. The analyzed metrics were scored as follows: severity – no harm = 1, lethal = 10; probability – not likely = 1, certainty = 10; detectability – always detected = 1, undetectable = 10. The three metrics were combined multiplicatively to determine the risk priority number (RPN) which defined the overall score for each FM and the order in which process modifications should be deployed. Results: Eighty-nine procedural steps were identified with 186 FM accompanied by 193 failure effects with 213 potential causes. Eighty-one of the FM were scored with a RPN > 10, and mitigations were developed for FM with RPN values exceeding ten. The initial treatment had the most FM (16) requiring mitigation development followed closely by treatment planning, segmentation, and plan preparation with fourteen each. The maximum RPN was 400 and involved target delineation. Conclusion: The FMEA process proved extremely useful in identifying previously unforeseen risks. New methods were developed and implemented for risk mitigation and error prevention. Similar to findings reported for adult patients, the process leading to the initial treatment has an associated high risk.

60 APPLIED LIFE SCIENCES↗

MO-DE-207-04: Imaging educational program on solutions to common pediatric imaging challenges

This imaging educational program will focus on solutions to common pediatric imaging challenges. The speakers will present collective knowledge on best practices in pediatric imaging from their experience at dedicated children’s hospitals. The educational program will begin with a detailed discussion of the optimal configuration of fluoroscopes for general pediatric procedures. Following this introduction will be a focused discussion on the utility of Dual Energy CT for imaging children. The third lecture will address the substantial challenge of obtaining consistent image post -processing in pediatric digital radiography. The fourth and final lecture will address best practices in pediatric MRI including a discussion of ancillary methods to reduce sedation and anesthesia rates. Learning Objectives: To learn techniques for optimizing radiation dose and image quality in pediatric fluoroscopy To become familiar with the unique challenges and applications of Dual Energy CT in pediatric imaging To learn solutions for consistent post-processing quality in pediatric digital radiography To understand the key components of an effective MRI safety and quality program for the pediatric practice.

60 APPLIED LIFE SCIENCES↗

Radiometric characterization process for locating radioactivity hold-up and measuring non-uniformly distributed sources - 15342

A novel approach to facility radiometric characterization for non-uniformly distributed radiation sources has been developed by ANTECH and is currently being employed at the Argonne National Laboratory. It is being applied to the measurement of a wide range of objects and the interiors and contents of laboratories and buildings. The integrated non destructive assay measurement process involves the use of a scanning spectroscopic gamma ray camera as well as high purity Germanium detectors with different collimators and hence differing detector fields of view to measure and quantify non-uniformly distributed sources of radioactivity in laboratory equipment, glove boxes, storage tanks, pipework and general laboratory objects and process components. The purpose of the radiometric characterization is to quantify radiation sources and radioactive contamination levels in facilities containing nuclear material and to ensure compliance with facility characterization requirements and for decontamination and decommissioning planning and execution. The integrated measurement process also involves automated data capture and processing software and a database with which both measurement instrument operators and subject matter expert analysts can interact. An appropriate measuring instrument (gamma camera, scintillation detector, high purity Germanium detector system, neutron detector or alpha-beta counter) records the measurement data and the measurement site is recorded in a photograph. All of the data relevant to the measurement (or set of measurements for a particular object) are recorded in the database including measured gamma ray spectra, equipment description and relevant calibration, measurement site photograph and measurement descriptive data. Once data analysis protocols are established for specific geometries and measurement situations they can be applied to the measured data in a partially automated manner, reducing analysis and transcription errors. In addition to measurements and data analysis the process also utilises radiometric modelling computer codes including MicroShield and Monte Carlo Neutrons Photons in order to perform model calculations where appropriate. In a typical measurement, the ANTECH RadSearch spectroscopic gamma camera is utilized to find areas of concentrated activity so that these areas can be measured and calculated separately from areas with diffuse contamination. The use of the gamma camera in scanning mode helps to ensure that the assay does not overestimate the detected radiation source, which is a frequent consequence of using standard far field geometry and attenuation analysis codes that assume uniformity of both density and radioactive source distribution. Once the hot spots are identified, high purity Germanium detector measurements are made using various collimators with wide or narrow fields of view as required. These measurements are then processed through a semi-automatic calculation process assuming an appropriate source configuration as identified by RadSearch. These source configurations include point sources, line sources or surface sources. The Generalized Geometry Hold-up algorithms are employed to determine an estimate of the activity of the various sources that are identified in a measurement. The ANTECH integrated measurement process provides an automated calculation procedure where the analyst can select the source type, geometry and appropriate input data, and then the software calculates the activity by radionuclide for all sources identified in the measurement. The measurement and analysis process is controlled under the ANTECH ISO9001: 2008 Quality Assurance System and managed by a site specific Quality Assurance Plan. Both Argonne National Laboratory and Department of Energy technical reviewers have vetted the Integrated Measurement and Analysis Process. The application of the measurement and analysis process is described and measurement examples are provided. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DOE Hanford Tank Side Cesium Removal System (TSCR) Update: Fabrication and Factory Acceptance Testing - 20300

The Tank Side Cesium Removal (TSCR) System is a modular, quickly-deployable, and passively safe system for efficiently removing solids and cesium from alkaline liquid waste raffinate created by fuel processing on the Hanford site. This paper provides an overview of the project with particular emphasis on completion of fabrication and factory acceptance testing (FAT). All TSCR System components are inside three enclosures known as the Process Enclosure, Ancillary Enclosure, and Control Enclosure. The Process Enclosure is seismic design category II (SDC-II) and built to withstand the rigors of transportation and lifting, high winds, volcanic ash fall, and heavy precipitation (snow) over a temperature range of -25 to 115 deg. F. The Process Enclosure and Control Enclosure were fabricated in AVANTech's Columbia, SC facility, while the Ancillary Enclosure was fabricated in AVANTech's Richland, WA facility. The design and preliminary documented safety analysis were completed in December 2019, with all work being performed in accordance with ASME NQA-1 quality assurance requirements. The Process Enclosure, Ion Exchange Columns (IXCs), and several other TSCR components have a nuclear safety function and are designated as safety significant structures, systems, and components (SS-SSCs). The NQA-1 Commercial Grade Dedication (CGD) process was used to identify critical characteristics in order to accept materials and items used for fabrication of several safety significant TSCR components. This paper also addresses unique aspects and challenges of implementing CGD in DOE facilities and systems. After fabrication and preliminary testing, the Process and Control Enclosures were shipped to AVANTech's Richland facility where the complete TSCR System was setup and connected in a represented layout and configuration that will be used on the Hanford site. Test tanks and pumps were put in place and connected to the TSCR Process Enclosure in a manner that mimicked interfacing Double Shell Tanks in the 241-AP Tank Farm. The TSCR System was then tested/operated under conditions equivalent to those planned for onsite operation. Testing was separated into five separate phases as defined below: - Phase 1: Confirmation of TSCR System readiness for the FAT; - Phase 2: Verification of TSCR System operation under standard conditions; - Phase 3: Demonstration of TSCR System operation under non-standard conditions; - Phase 4: Demonstration of ion exchange media removal from an IXC; and - Phase 5: Completion of TSCR System lift plans and site mobilization. The Hanford Tank Operations Contractor, Washington River Protection Solutions (WRPS), participated in all phases of testing. Testing at AVANTech's Richland Facility allowed WRPS personnel to familiarize themselves with TSCR operations in a radiologically clean facility prior to onsite mobilization. Engineering and operations personnel gained valuable experience that allowed them to better refine onsite operational protocols and procedures - including handling and movement of IXCs with a forklift. This paper describes the technologies used by the TSCR System as well as how these technologies are deployed and operated to advance the Hanford mission of safely, efficiently, and effectively treating tank waste. It also provides detailed information on fabrication and FAT, including operational data from simulated tank waste runs. A project schedule for WRPS' planned construction acceptance testing, operational acceptance testing, and actual tank waste treatment is provided. This presentation should be of great interest to parties responsible for the design, testing, and mobilization of modular NQA-1 technologies for the treatment of raffinate and similar liquid wastes containing high concentrations of radioactive cesium. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Bronchopleural Fistula After Radiofrequency Ablation of Lung Tumours

The present article describes two cases of bronchopleural fistula (BPF) occurring after radiofrequency ablation of lung tumors. Both procedures were carried out using expandable multitined electrodes, with no coagulation of the needle track. After both ablations, ground-glass opacities encompassed the nodules and abutted the visceral pleura. The first patient had a delayed pneumothorax, and the second had a recurrent pneumothorax. Both cases of BPF were diagnosed on follow-up computed tomography chest scans (i.e., visibility of a distinct channel between the lung or a peripheral bronchus and the pleura) and were successfully treated with chest tubes alone. Our goal is to highlight the fact that BPF can occur without needle-track coagulation and to suggest that minimally invasive treatment is sufficient to cure BPFs of this specific origin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗