Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “compositional noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Effects on image quality of a 2D antiscatter grid in x-ray digital breast tomosynthesis: Initial experience using the dual modality (x-ray and molecular) breast tomosynthesis scanner

Purpose: Radiation scattered from the breast in digital breast tomosynthesis (DBT) causes image degradation, including loss of contrast between cancerous and background tissue. Unlike in 2-dimensional (2D) mammography, an antiscatter grid cannot readily be used in DBT because changing alignment between the tube and detector during the scan would result in unacceptable loss of primary radiation. However, in the dual modality breast tomosynthesis (DMT) scanner, which combines DBT and molecular breast tomosynthesis, the tube and detector rotate around a common axis, thereby maintaining a fixed tube-detector alignment. This C-arm geometry raises the possibility of using a 2D (cellular) focused antiscatter grid. The purpose of this study is to assess change in image quality when using an antiscatter grid in the DBT portion of a DMT scan under conditions of fixed radiation dose. Methods: Two 2D focused prototype grids with 80 cm focal length were tested, one stack-laminated from copper (Cu) and one cast from a tungsten-polymer (W-poly). They were reciprocated using a motion scheme designed to maximize transmission of primary x-ray photons. Grid-in and grid-out scatter-to-primary ratios (SPRs) were measured for rectangular blocks of material simulating 30%, 50%, and 70% glandular tissue compositions. For assessment of changes in image quality through the addition of a grid, the Computerized Imaging Reference Systems, Inc., phantom Model 011A containing a set of 1 cm thick blocks simulating a range of glandular/adipose ratios from 0/100 to 100/0 was used. To simulate 6.5 and 8.5 cm thick compressed breasts, 1 cm thick slices of PMMA were added to the Model 011A phantom. DBT images were obtained with and without the grid, with exposure parameters fixed for a given compressed thickness. Signal-difference-to-noise ratios (SDNRs), contrast, and voxel value-based attenuation coefficients (μ) were measured for all blocks from reconstructed phantom images. Results: For 4, 6, and 8 cm tissue-equivalent block phantom thicknesses, the inclusion of the W-poly grid reduced the SPR by factors of 5, 6, and 5.8, respectively. For the same thicknesses, the copper grid reduced the SPR by factors of 3.9, 4.5, and 4.9. For the 011A phantom, the W-poly grid raised the SDNR of the 70/30 block from 0.8, −0.32, and −0.72 to 0.9, 0.76, and 0.062 for the 4.5, 6.5, and 8.5 cm phantoms, respectively. It raised the SDNR of the 100/0 block from 3.78, 1.95, and 1.0 to 3.79, 3.67, and 3.25 for the 4.5, 6.5, and 8.5 cm phantoms, respectively. Inclusion of the W-poly grid improved the accuracy of image-based μ values for all block compositions. However, smearing of attenuation across slices due to limited angular sampling decreases the sensitivity of voxel values to changing composition compared to theoretical μ values. Conclusions: Under conditions of fixed radiation dose to the breast, use of a 2D focused grid increased contrast, SDNR, and accuracy of estimated attenuation for mass-simulating block compositions in all phantom thicknesses tested, with the degree of improvement depending upon material composition. A 2D antiscatter grid can be usefully incorporated in DBT systems that employ fully isocentric tube-detector rotation.

60 APPLIED LIFE SCIENCES↗

Improvements in High Speed, High Resolution Dynamic Digital Image Correlation for Experimental Evaluation of Composite Drive System Components

Composite materials have the potential to reduce the weight of rotating drive system components. However, these components are more complex to design and evaluate than static structural components in part because of limited ability to acquire deformation and failure initiation data during dynamic tests. Digital image correlation (DIC) methods have been developed to provide precise measurements of deformation and failure initiation for material test coupons and for structures under quasi-static loading. Attempts to use the same methods for rotating components (presented at the AHS International 68th Annual Forum in 2012) are limited by high speed camera resolution, image blur, and heating of the structure by high intensity lighting. Several improvements have been made to the system resulting in higher spatial resolution, decreased image noise, and elimination of heating effects. These improvements include the use of a high intensity synchronous microsecond pulsed LED lighting system, different lenses, and changes in camera configuration. With these improvements, deformation measurements can be made during rotating component tests with resolution comparable to that which can be achieved in static tests

high speed imaging↗

Submillimetric Spectroscopic Observations of Volatiles in Comet C-2004 Q2 (Machholz)

Submillimeter spectroscopic observations of comets provide an important tool for understanding their chemical composition and enable a taxonomic classification. Aims. We aim to determine the production rates of several parent- and product volatiles and the C-12/C-13 isotopic carbon ratio in the long-period comet C/2004 Q2 (Machholz), which is likely to originate from the Oort Cloud. Methods. The line emission from several molecules in the coma was measured with high signal-to-noise ratio in January 2005 at heliocentric distance of 1.2 AU by means of high-resolution spectroscopic observations using the Submillimeter Telescope (SMT) at the Arizona Radio Observatory (ARO). Results. We have obtained production rates of several volatiles (CH3OH, HCN, H(sup 13)CN, HNC, H2CO, CO, and CS) by comparing the observed and simulated line-integrated intensities. We calculated the synthetic profiles using a radiative transfer code that includes collisions between neutrals and electrons, and the effects of radiative pumping of the fundamental vibrational levels by solar infrared radiation. Furthermore, multiline observations of the CH3OH J = 7-6 series allow us to estimate the rotational temperature using the rotation diagram technique. We find that the CH3OH population distribution of the levels sampled by these lines can be described by a rotational temperature of 40 +/- 3 K. Derived mixing ratios relative to hydrogen cyanide are CO/CH3OH/H2CO/CS/HNC/HC-13N/HCN= 30.9/24.6/4.8/0.57/0.031/0.013/1 assuming a pointing offset of 8" due to the uncertain ephemeris at the time of the observations and the telescope pointing error. Conclusions. The measured relative molecular abundances in C/2004 Q2 (Machholz) are between low- to typical values of those obtained in Oort Cloud comets, suggesting that it has visited the inner solar system previously and undergone thermal processing. The HNC/HCN abundance ratio of approx 3.1% is comparable to that found in other comets, accounting for the dependence on the heliocentric distance, and could possibly be explained by ion-molecule chemical processes in the low-temperature atmosphere. From a tentative HC-13N detection, the measured value of 97 +/- 30 for the HC-12N/HC-13N isotopologue pair is consistent with a telluric value. The outgassing variability observed in the HCN production rates over a period of two hours is consistent with the rotation of the nucleus derived using different observational techniques.

chemical composition↗

Modeling the Spectral Diversity of Quasars in the Sixteenth Data Release from the Sloan Digital Sky Survey

Abstract We present a new approach to capturing the broad diversity of emission-line and continuum properties in quasar spectra. We identify populations of spectrally similar quasars through pixel-level clustering on 12,968 high signal-to-noise ratio (S/N) spectra from the Sloan Digital Sky Survey (SDSS) in the redshift range of 1.57 < z < 2.4. Our clustering analysis finds 396 quasar spectra that are not assigned to any population, 15 misclassified spectra, and 6 quasars with incorrect redshifts. We compress the quasar populations into a library of 684 high-S/N composite spectra, anchored in redshift space by the Mg ii emission line. Principal component analysis on the library results in an eigenspectrum basis spanning 1067–4007 Å. We model independent samples of SDSS quasar spectra with the eigenbasis, allowing for a free redshift parameter. Our models achieve a median reduced χ 2 on non–broad absorption line quasar spectra that is reduced by 8.5% relative to models using the eigenspectra from the SDSS spectroscopic pipeline. A significant contribution to the relative improvement is from the ability to reconstruct the range of emission-line variation. The redshift estimates from our model are consistent with the Mg ii emission-line redshift with an average offset that displays 51.4% less redshift-dependent variation relative to the SDSS eigenspectra. Our method for developing quasar spectra models can improve automated classification and predict the intrinsic spectrum in regions affected by intervening absorbers such as Ly α , C iv , and Mg ii , thus benefiting studies of large-scale structure.

79 ASTRONOMY AND ASTROPHYSICS↗

Composite bolometers for submillimeter wavelengths

The fabrication and optimization of composite submillimeter wave bolometers with metal film absorbing elements and doped Ge thermometers are described. Performance characteristics are given for 4 x 4-mm bolometers designed for operation at both He-4 and He-3 temperatures. The performance expected from such bolometers when they are optimized for various values of background loading is calculated. Current dependent noise, which can arise from any of several sources, is included in the analysis. This can make it impossible to reach the background fluctuation noise limit. Feed structures for these bolometers which employ Winston light concentrators are described.

Nishioka, N. S.↗

Designing Delta-DOR acquisition strategies to determine highly elliptical earth orbits

Delta-DOR acquisition strategies are designed for use in determining highly elliptical earth orbits. The requirements for a possible flight demonstration are evaluated for the Charged Composition Explorer spacecraft of the Active Magnetospheric Particle Tracer Explorers. The best-performing strategy uses data spanning the view periods of two orthogonal baselines near the same orbit periapse. The rapidly changing viewing geometry yields both angular position and velocity information, but each observation may require a different reference quasar. The Delta-DOR data noise is highly dependent on acquisition geometry, varying several orders of magnitude across the baseline view periods. Strategies are selected to minimize the measurement noise predicted by a theoretical model. Although the CCE transponder is limited by S-band and a small bandwidth, the addition of Delta-DOR to coherent Doppler and range improves the one-sigma apogee position accuracy by more than an order of magnitude. Additional Delta-DOR accuracy improvements possible using dual-frequency (S/X) calibration, increased spanned bandwidth, and water-vapor radiometry are presented for comparison. With these benefits, the residual Delta-DOR data noise is primarily due to quasar position uncertainties.

Frauenholz, R. B.↗

Factors controlling precision and accuracy in isotope-ratio-monitoring mass spectrometry

The performance of systems in which picomole quantities of sample are mixed with a carrier gas and passed through an isotope-ratio mass spectrometer system was examined experimentally and theoretically. Two different mass spectrometers were used, both having electron-impact ion sources and Faraday cup collector systems. One had an accelerating potential of 10kV and accepted 0.2 mL of He/min, producing, under those conditions, a maximum efficiency of 1 CO2 molecular ion collected per 700 molecules introduced. Comparable figures for the second instrument were 3 kV, 0.5 mL of He/min, and 14000 molecules/ion. Signal pathways were adjusted so that response times were <200 ms. Sample-related ion currents appeared as peaks with widths of 3-30 s. Isotope ratios were determined by comparison to signals produced by standard gases. In spite of rapid variations in signals, observed levels of performance were within a factor of 2 of shot-noise limits. For the 10-kV instrument, sample requirements for standard deviations of 0.1 and 0.5% were 45 and 1.7 pmol, respectively. Comparable requirements for the 3-kV instrument were 900 and 36 pmol. Drifts in instrumental characteristics were adequately neutralized when standards were observed at 20-min intervals. For the 10-kV instrument, computed isotopic compositions were independent of sample size and signal strength over the ranges examined. Nonlinearities of <0.04%/V were observed for the 3-kV system. Procedures for observation and subtraction of background ion currents were examined experimentally and theoretically. For sample/ background ratios varying from >10 to 0.3, precision is expected and observed to decrease approximately 2-fold and to depend only weakly on the precision with which background ion currents have been measured.

NASA Discipline Exobiology↗

A 2-D Piston Effect Solution for the Relaxation in the MISTE Cell

When a large density stratification is no longer a problem in a microgravity environment, one would like to increase the sample size in order to increase the signal-to-noise ratio for a specific heat measurement. To reduce the equilibration time associated with the large sample size, we designed a cylindrical cell containing a stack of plates that separate the bulk fluid into 60 equally thin layers. To understand the thermal behavior of the whole cell, we analyzed the thermal behavior of a 2-D composite system of a cylindrical near-critical fluid layer in contact with a cylindrical copper plate. In this 2-D analysis, the circumference boundary of the two cylindrical layers is subjected to a step temperature change. The solution of this 2-D composite system includes the piston effect that speeds up the equilibration in the near-critical fluid layer and the pure diffusion in the copper plate. The results of this analysis indicate that the characteristic length for the equilibration of the stacked cell is determined by an effective thickness of a single fluid layer instead of the total height of the cylindrical cell.

Weilert, Mark↗

Investigation of Facsimile Camera-spectrometer Capability in the 1.0 to 2.7 Micron Spectral Range

The capability of the facsimile camera augmented with a filter-spectrometer to provide scientifically valuable information in the 1.0 to 2.7 microns spectral range was investigated for a future planetary lander mission to Mars. A computer model was used to evaluate tradeoffs between signal-to-noise ratio, spatial and spectral resolution, and the number of spectral channels. Spectral absorption features resulting from water and chemical variations found in pyroxenes were used to represent scientific information of interest to biologists and geologists. Expected output data from a filter-spectrometer is illustrated which indicates that important information pertaining to water content and chemical composition can be obtained using six to eight spectral channels with 0.3 degree spatial resolution.

Kelly, W. L., IV↗

Response of laminated plates to non-stationary random excitation

The response of composite laminated plates subjected to nonstationary random excitation is determined. First-order shear deformation theory is used for the analysis of symmetric cross-ply and antisymmetric angle-ply plates. The time-dependent component of the forcing function is taken as a product of a well-defined, slowly varying envelope function, and a noise function, assumed to be white or narrow-band random excitation.

Cederbaum, Gabriel↗

Retrievals of Jovian Tropospheric Phosphine from Cassini/CIRS

On December 30th 2000, the Cassini-Huygens spacecraft reached the perijove milestone on its continuing journey to the Saturnian system. During an extended six-month encounter, the Composite Infrared Spectrometer (CIRS) returned spectra of the Jovian atmosphere, rings and satellites from 10-1400 cm(exp -1) (1000-7 microns) at a programmable spectral resolution of 0.5 to 15 cm(exp -1). The improved spectral resolution of CIRS over previous IR instrument-missions to Jupiter, the extended spectral range, and higher signal-to-noise performance provide significant advantages over previous data sets. CIRS global observations of the mid-infrared spectrum of Jupiter at medium resolution (2.5 cm(exp -1)) have been analysed both with a radiance differencing scheme and an optimal estimation retrieval model to retrieve the spatial variation of phosphine and ammonia fractional scale height in the troposphere between 60 deg S and 60 deg N at a spatial resolution of 6 deg. The ammonia fractional scale height appears to be high over the Equatorial Zone (EZ) but low over the North Equatorial Belt (NEB) and South Equatorial Belt (SEB) indicating rapid uplift or strong vertical mixing in the EZ. The abundance of phosphine shows a similar strong latitudinal variation which generally matches that of the ammonia fractional scale height. However while the ammonia fractional scale height distribution is to a first order symmetric in latitude, the phosphine distribution shows a North/South asymmetry at mid latitudes with higher amounts detected at 40 deg N than 40 deg S. In addition the data show that while the ammonia fractional scale height at this spatial resolution appears to be low over the Great Red Spot (GRS), indicating reduced vertical mixing above the approx. 500 mb level, the abundance of phosphine at deeper levels may be enhanced at the northern edge of the GRS indicating upwelling.

Irwin, P. G. J.↗

Use of Acoustic Emission to Monitor Progressive Damage Accumulation in Kevlar (R) 49 Composites

Acoustic emission (AE) data acquired during intermittent load hold tensile testing of epoxy impregnated Kevlar(Registeres TradeMark) 49 (K/Ep) composite strands were analyzed to monitor progressive damage during the approach to tensile failure. Insight into the progressive damage of K/Ep strands was gained by monitoring AE event rate and energy. Source location based on energy attenuation and arrival time data was used to discern between significant AE attributable to microstructural damage and spurious AE attributable to noise. One of the significant findings was the observation of increasing violation of the Kaiser effect (Felicity ratio < 1.0) with damage accumulation. The efficacy of three different intermittent load hold stress schedules that allowed the Felicity ratio to be determined analytically is discussed.

Waller, Jess M.↗

Single-shot femtosecond laser-induced breakdown spectroscopy in low-density gases

Single-shot fs laser-induced breakdown spectroscopy (LIBS) has been used to interrogate low-density gases of H 2 ⁠, CH 4 ⁠, CO 2 ⁠, and H 2 O ranging from 0.5 × 10 15 to 9.1 × 10 15 cm −3 (15–275 mTorr). Strong spectral signatures were observed above the noise baseline for each test gas at all densities considered. Unique molecular signatures were observed for both CH 4 and CO 2 along with atomic features for each gas. The LIBS intensity response with respect to density was determined for each species using Voigt lineshape fitting or numerical integration. Finally, the collection and analysis of LIBS spectra of composite mixtures of CH 4 –CO 2 and CH 4 –H 2 demonstrates that the extraction of individual densities from gas mixtures is feasible at low densities.

Artificial neural networks↗

Bowtie filters for dedicated breast CT: Analysis of bowtie filter material selection

Purpose: For a given bowtie filter design, both the selection of material and the physical design control the energy fluence, and consequently the dose distribution, in the object. Using three previously described bowtie filter designs, the goal of this work is to demonstrate the effect that different materials have on the bowtie filter performance measures. Methods: Three bowtie filter designs that compensate for one or more aspects of the beam-modifying effects due to the differences in path length in a projection have been designed. The nature of the designs allows for their realization using a variety of materials. The designs were based on a phantom, 14 cm in diameter, composed of 40% fibroglandular and 60% adipose tissue. Bowtie design #1 is based on single material spectral matching and produces nearly uniform spectral shape for radiation incident upon the detector. Bowtie design #2 uses the idea of basis-material decomposition to produce the same spectral shape and intensity at the detector, using two different materials. With bowtie design #3, it is possible to eliminate the beam hardening effect in the reconstructed image by adjusting the bowtie filter thickness so that the effective attenuation coefficient for every ray is the same. Seven different materials were chosen to represent a range of chemical compositions and densities. After calculation of construction parameters for each bowtie filter design, a bowtie filter was created using each of these materials (assuming reasonable construction parameters were obtained), resulting in a total of 26 bowtie filters modeled analytically and in the PENELOPE Monte Carlo simulation environment. Using the analytical model of each bowtie filter, design profiles were obtained and energy fluence as a function of fan-angle was calculated. Projection images with and without each bowtie filter design were also generated using PENELOPE and reconstructed using FBP. Parameters such as dose distribution, noise uniformity, and scatter were investigated. Results: Analytical calculations with and without each bowtie filter show that some materials for a given design produce bowtie filters that are too large for implementation in breast CT scanners or too small to accurately manufacture. Results also demonstrate the ability to manipulate the energy fluence distribution (dynamic range) by using different materials, or different combinations of materials, for a given bowtie filter design. This feature is especially advantageous when using photon counting detector technology. Monte Carlo simulation results from PENELOPE show that all studied material choices for bowtie design #2 achieve nearly uniform dose distribution, noise uniformity index less than 5%, and nearly uniform scatter-to-primary ratio. These same features can also be obtained using certain materials with bowtie designs #1 and #3. Conclusions: With the three bowtie filter designs used in this work, the selection of material is an important design consideration. An appropriate material choice can improve image quality, dose uniformity, and dynamic range.

60 APPLIED LIFE SCIENCES↗

HIRIS - EOS instrument with high spectral and spatial resolution

The High-Resolution Imaging Spectrometer (HIRIS) is designed for NASA's Earth Observing System (EOS). It will have 10-nm wide spectral bands from 0.4-2.5 microns at 30 m spatial resolution over a 30 km swath. The spectral resolution allows identification of many minerals in rocks and soils, important algal pigments in oceans and inland waters, spectral changes associated with plant canopy biochemistry, composition of atmospheric aerosols, and grain size of snow and contamination by absorbing impurities. The bands will have 12-bit quantization over a dynamic range suitable for bright targets, such as snow. For targets of low brightness, such as water bodies, image-motion compensation will allow gains up to a factor of 8 to increase signal-to-noise ratios. The sensor will be able to point + or - 24 deg crosstrack and +60/-30 deg downtrack. In the 824-km orbit altitude proposed for EOS, the crosstrack pointing capability will allow 4-5 views during a 16-day revisit cycle.

Dozier, Jeff↗

The performance of suppressed carrier receivers in a pulsed RFI environment

This paper investigates the tracking performance of a Costas loop in the presence of single and multiple in-band pulsed RFI signals and receiver additive noise. It is shown that the loop's tracking performance is very sensitive to the pulse durations of the RFI signals, as well as their repetition rates and peak powers relative to those of the desired signal. The presence of in-band RFI can affect the loop's tracking performance in basically three ways. 1) The loop tracks the composite phase of the RFI instead of the phase of the desired signal when the effective RFI power is greater than that of the signal. 2) When the effective RFI power is not sufficiently large to capture the loop, there still will exist static phase error biases which cause the loop to lock at a phase between that of the desired signal and the composite RFI. 3) There is an increase in the rms phase jitter over the nominal design. These latter two effects degrade the bit error probability performance of the receiver. More significantly, if the nominal loop bandwidth is not designed properly to account for the increase in jitter phenomenon, frequency cycle slipping may result.

Simon, M. K.↗

Variations of the semi-diurnal tidal wind in the meteor region with periods of about 27 and 13.5 days

Daily values of sunspot number and solar radio emission at 10.7 cm wavelength show a well known strong modulation with a period of 27 days, the Sun's rotation period. Recent satellite measurements revealed the same modulation of the ultraviolet irradiance at wavelength below 300 nm. These UV variations can influence the thermal heating of the ozone layer by altering the chemical composition. Therefore, one can also expect a corresponding variation in the middle atmosphere of the semi-diurnal tide, which is thermally excited essentially by absorption of UV between 200 and 370 nm in the upper ozone layer. Results of radar meteor wind measurements were used to detect a presumable very weak 27 day modulation within the natural and artificial noise of the daily values of the semi-diurnal wind amplitude. The summer period was chosen because of its relatively steady conditions and the maximum amplitudes during the year. The results of this investigation are given and discussed.

Greisiger, K. M.↗

HIRIS - The High Resolution Imaging Spectrometer

The High-Resolution Imaging Spectrometer (HIRIS) is a JPL facility instrument designed for NASA's Earth Observing System (Eos).It will have 10-nm wide spectral bands from 0.4-2.5 microns at 30 m spatial resolution over a 30 km swath. The spectral resolution allows identification of many minerals in rocks and soils, important algal pigments in oceans and inland waters, spectral changes associated with plant canopy biochemistry, composition of atmospheric aerosols, and grain size of snow and its contamination by absorbing impurities. The bands wil have 12-bit quantization over a dynamic range suitable for bright targets, such as snow. For targets of low brightness, such as water bodies, image-motion compensation will allow gains up to a factor of eight to increase signal-to-noise ratios. In the 824-km orbit altitude proposed for Eos, the crosstrack pointing capability will allow 4-5 views during a 16-day revisit cycle.

Dozier, Jeff↗