Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “biomedical device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

MO-AB-204-02: IHE RAD [Health care]

You’ve experienced the frustration: vendor A’s device claims to work with vendor B’s device, but the practice doesn’t match the promise. Getting devices working together is the hidden art that Radiology and Radiation Oncology staff have to master. To assist with that difficult process, the Integrating the Healthcare Enterprise (IHE) effort was established in 1998, with the coordination of the Radiological Society of North America. Integrating the Healthcare Enterprise (IHE) is a consortium of healthcare professionals and industry partners focused on improving the way computer systems interconnect and exchange information. This is done by coordinating the use of published standards like DICOM and HL7. Several clinical and operational IHE domains exist in the healthcare arena, including Radiology and Radiation Oncology. The ASTRO-sponsored IHE Radiation Oncology (IHE-RO) domain focuses on radiation oncology specific information exchange. This session will explore the IHE Radiology and IHE RO process for; IHE solicitation process for new profiles. Improving the way computer systems interconnect and exchange information in the healthcare enterprise Supporting interconnectivity descriptions and proof of adherence by vendors Testing and assuring the vendor solutions to connectivity problems. Including IHE profiles in RFPs for future software and hardware purchases. Learning Objectives: Understand IHE role in improving interoperability in health care. Understand process of profile development and implantation. Understand how vendors prove adherence to IHE RO profiles. S. Hadley, ASTRO Supported Activity.

60 APPLIED LIFE SCIENCES↗

MO-AB-204-03: Profile Development and IHE Process

You’ve experienced the frustration: vendor A’s device claims to work with vendor B’s device, but the practice doesn’t match the promise. Getting devices working together is the hidden art that Radiology and Radiation Oncology staff have to master. To assist with that difficult process, the Integrating the Healthcare Enterprise (IHE) effort was established in 1998, with the coordination of the Radiological Society of North America. Integrating the Healthcare Enterprise (IHE) is a consortium of healthcare professionals and industry partners focused on improving the way computer systems interconnect and exchange information. This is done by coordinating the use of published standards like DICOM and HL7. Several clinical and operational IHE domains exist in the healthcare arena, including Radiology and Radiation Oncology. The ASTRO-sponsored IHE Radiation Oncology (IHE-RO) domain focuses on radiation oncology specific information exchange. This session will explore the IHE Radiology and IHE RO process for; IHE solicitation process for new profiles. Improving the way computer systems interconnect and exchange information in the healthcare enterprise Supporting interconnectivity descriptions and proof of adherence by vendors Testing and assuring the vendor solutions to connectivity problems. Including IHE profiles in RFPs for future software and hardware purchases. Learning Objectives: Understand IHE role in improving interoperability in health care. Understand process of profile development and implantation. Understand how vendors prove adherence to IHE RO profiles. S. Hadley, ASTRO Supported Activity.

60 APPLIED LIFE SCIENCES↗

Frequency-Domain Intravascular Optical Coherence Tomography of the Femoropopliteal Artery

Purpose: Optical coherence tomography (OCT) is a catheter-based imaging method that employs near-infrared light to produce high-resolution intravascular images. The authors report the safety and feasibility and illustrate common imaging findings of frequency-domain OCT (FD-OCT) imaging of the femoropopliteal artery in a series of 20 patients who underwent infrainguinal angioplasty. Methods: After crossing the lesion of interest, OCT was performed with a dextrose saline flush technique with simultaneous obstructive manual groin compression. An automatic pullback FD-OCT device was employed (each scan acquiring 54 mm of vessel lumen in 271 consecutive frames). OCT images were acquired before and after balloon dilatation and following provisional stenting if necessary and were evaluated for baseline characteristics of plaque or in-stent restenosis (ISR), vessel wall trauma after angioplasty, presence of thrombus, stent apposition, and tissue prolapse. Imaging follow-up was not included in this study's protocol. Results: Twenty-seven obstructive lesions (18 cases of de novo atherosclerosis and 9 of ISR) of the femoropopliteal artery were imaged and 148 acquisitions were analyzed in total. High-resolution intravascular OCT imaging with effective blood clearance was achieved in 93.9%. Failure was mainly attributed to preocclusive proximal lesions and/or collateral flow. Mixed features of lipid pool areas, calcium deposits, necrotic core, and fibrosis were identified in all of the imaged atherosclerotic lesions, whereas ISR was purely fibrotic. After balloon angioplasty, OCT identified extensive intimal tears in all cases and one case of severe dissection that biplane subtraction angiography failed to identify. Conclusions: Infrainguinal frequency-domain optical coherence tomography is safe and feasible and may provide intravascular high-resolution imaging of the femoropopliteal artery during infrainguinal angioplasty procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Benefits of Synchrotron Microangiography for Dynamic Studies of Smooth Muscle and Endothelial Roles in the Pathophysiology of Vascular Disease

Changes in endothelial and smooth muscle function compromise organ perfusion in the chronic disease states of diabetes, atherosclerosis and hypertension. Moreover, vascular dysfunction increases the likelihood of lethal acute events such as myocardial infarction and stroke, which are now leading causes of adult mortality. Many circulating and local tissue factors in these disease states contribute to impaired vasomotor regulation of the arterial vessels, leading to spasm, chronic constriction and eventually vessel remodelling. X-ray contrast absorption imaging allows assessment of vessel lumen diameter and the factors contributing to steady-state vessel calibre, however, conventional clinical devices (>200 {mu}m resolution) are not adequate to detect microvessels or accurately assess function in real time. Using synchrotron imaging we are now able to detect small vessel calibres ({approx}30 {mu}m) and quantify regional differences in calibre even under conditions of high heart rate (>500 bpm). Herein we describe recent experiments that were conducted at the Japanese Synchrotron, SPring-8 using anaesthetised Sprague-Dawley rats and C57Bl/6 mice and a synchrotron radiation contrast angiography (single narrow energy bandwidth) approach based on selective arterial injection of iodine contrast agents. Application of this approach to imaging of the heart and other vasculatures are described. Our studies show that within-animal comparisons of 3-4 branching orders of arterial vessels are possible using small bolus contrast injections and appropriate contrast washout times (15-30 min) in many organ systems. Determination of relative calibre changes before and after any treatment allows us to evaluate the contributions of different endogenous factors and ligand-receptor pathways in the maintenance of vasomotor tone. Finally, we will present our findings relating to novel therapies to prevent endothelial dysfunction in heart failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Wearable Biosensor Monitor to Support Autonomous Crew Health and Readiness to Perform

For future human exploration missions, NASA needs a health monitoring system composed of hardware that is compact, fully interoperable with an integrated data management system, and requires minimal consumables. Such a system will be achieved through the integration of small, easy to use biomedical sensors that will have the ability to measure, store and transmit physiological parameters during operational and ambulatory activity. Since 2012, the Canadian Space Agency (CSA) has been active in funding the development of wearable biomonitoring sensors. The Astroskin is the first prototype and consists of a shirt-based garment and headband with embedded sensors, and associated software and technology that measure vital signs, sleep quality and activity level of the wearer. NASA and CSA have been collaborating since 2014 to test and validate this system in a lab environment at Ames Research Center and more recently in the Human Exploration Research Analog (HERA) located at Johnson Spaceflight Center. Specific objectives of the HERA study were: 1) to assess the performance of the Astroskin biosensor system for long-term health monitoring (24-hours) capabilities and during exercise as a measure of crew fitness; 2) to obtain crew feedback on comfort and usability of the Astroskin system; 3) to demonstrate performance of Bluetooth communication during real-time transmission and for verification of data in this environment; and 4) to obtain baseline data for further development of algorithms and tools that facilitate decision support for diagnosing and monitoring of a sick or injured crewmember. HERA Campaign 3 included four missions (each 30-days in duration) with four crewmembers assigned to each mission. A total of 9 men and 7 women participated in the Astroskin evaluation that included continuous physiological monitoring (24-hours) on mission days MD-11, MD1 (high workload), MD15 (low workload), MD19, MD29, and MD+7. Mission days 19 and 29 also included 30 minutes of sub-maximal exercise on a cycle ergometer. Following each 24-hour monitoring session crew physiological data were downloaded to laptops and each crewmember completed a 28 question survey on their experiences with the Astroskin hardware and software. This presentation will focus on lessons learned from the HERA missions. Specifically it will address Astroskin system performance in terms of data loss and data quality (no comparison to lab standard devices), wireless communication with the onboard mobile device, crew usability and comfort, and future development of a next generation biomonitoring system.

crew fitness↗

Accuracy evaluation of the optical surface monitoring system on EDGE linear accelerator in a phantom study

Frameless stereotactic radiosurgery (SRS) requires dedicated systems to monitor the patient position during the treatment to avoid target underdosage due to involuntary shift. The optical surface monitoring system (OSMS) is here evaluated in a phantom-based study. The new EDGE linear accelerator from Varian (Varian, Palo Alto, CA) integrates, for cranial lesions, the common cone beam computed tomography (CBCT) and kV-MV portal images to the optical surface monitoring system (OSMS), a device able to detect real-time patient's face movements in all 6 couch axes (vertical, longitudinal, lateral, rotation along the vertical axis, pitch, and roll). We have evaluated the OSMS imaging capability in checking the phantoms' position and monitoring its motion. With this aim, a home-made cranial phantom was developed to evaluate the OSMS accuracy in 4 different experiments: (1) comparison with CBCT in isocenter location, (2) capability to recognize predefined shifts up to 2° or 3 cm, (3) evaluation at different couch angles, (4) ability to properly reconstruct the surface when the linac gantry visually block one of the cameras. The OSMS system showed, with a phantom, to be accurate for positioning in respect to the CBCT imaging system with differences of 0.6 ± 0.3 mm for linear vector displacement, with a maximum rotational inaccuracy of 0.3°. OSMS presented an accuracy of 0.3 mm for displacement up to 1 cm and 1°, and 0.5 mm for larger displacements. Different couch angles (45° and 90°) induced a mean vector uncertainty < 0.4 mm. Coverage of 1 camera produced an uncertainty < 0.5 mm. Translations and rotations of a phantom can be accurately detect with the optical surface detector system.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-525: Monitordeep-Inspiratory Breathhold with a Laser Sensor for Radiation Therapy of Left Breast Cancer

Purpose: Radiation therapy (RT) of left sided breast cancers with deep-inspiratory breathhold (DIBH) can reduce the dose to heart. The purpose of this study is to develop and test a new laser-based tool to improve ease of RT delivery using DIBH. Methods: A laser sensor together with breathing monitor device (Anzai Inc., Japan) was used to record the surface breathing motion of phantom/volunteers. The device projects a laser beam to the chestwall and the reflected light creates a focal spot on a light detecting element. The position change of the focal spot correlates with the patient’s breathing motion and is measured through the change of current in the light detecting element. The signal is amplified and displayed on a computer screen, which is used to trigger radiation gating. The laser sensor can be easily mounted to the simulation/treatment couch with a fixing plate and a magnet base, and has a sensitivity range of 10 to 40 cm from the patient. The correlation of breathing signals detected by laser sensor and visionRT is also investigated. Results: It is found that the measured breathing signal from the laser sensor is stable and reproducible and has no noticeable delay. It correlates well with the VisionRT surface imaging system. The DIBH reference level does not change with movement of the couch because the laser sensor and couch move together. Conclusion: The Anzai laser sensor provides a cost-effective way to improve beam gating with DIBH for treating left breast cancer. It can be used alone or together with VisionRT to determine the correct DIBH level during the radiation treatment of left breast cancer with DIBH.

60 APPLIED LIFE SCIENCES↗

Comparison of Technical and Clinical Outcome of Transjugular Portosystemic Shunt Placement Between a Bare Metal Stent and a PTFE-Stentgraft Device

PurposeTo analyse technical and clinical success of transjugular intrahepatic portosystemic shunt (TIPS) in patients with portal hypertension and compare a stent and a stentgraft with regard to clinical and technical outcome and associated costs.Materials and Methods170 patients (56 ± 12 years, 32.9 % females) treated with TIPS due to portal hypertension were reviewed. 80 patients received a stent (group 1) and 83 a stentgraft (group 2), and seven interventions were unsuccessful. Technical data, periprocedural imaging, follow-up ultrasound and clinical data were analysed with focus on technical success, patency, clinical outcome and group differences. Cost analysis was performed.ResultsPortal hypertension was mainly caused by ethyltoxic liver cirrhosis with ascites as dominant symptom (80 %). Technical success was 93.5 % with mean portosystemic gradient decrease from 16.1 ± 4.8 to 5.1 ± 2.1 mmHg. No significant differences in technical success and portosystemic gradient decrease between the groups were observed. Kaplan–Meier analysis yielded significant differences in primary patency after 14 days, 6 months and 2 years in favour of the stentgraft. Both groups showed good clinical results without significant difference in 1-year survival and hepatic encephalopathy rate. Costs to establish TIPS and to manage 2-year follow-up with constant patency and clinical success were 8876 € (group 1) and 9394 € (group 2).ConclusionTIPS is a safe and effective procedure to manage portal hypertension. Stent and stentgraft enabled good technical and clinical results with a low complication rate. Primary patency rates are clearly in favour of the stentgraft, whereas the stent was more cost effective with similar clinical results in both groups.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-G-213-00: The International Electrotechnical Commission (IEC): What Is It and Why Should Medical Physicists Care?

The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists.

60 APPLIED LIFE SCIENCES↗

TU-G-213-01: IEC and US Committee Activities and Organizational Structure

The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists.

60 APPLIED LIFE SCIENCES↗

TU-G-213-02: IEC Subcommittee 62B (Diagnostic Imaging Equipment): Recent and Active Projects

The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists.

60 APPLIED LIFE SCIENCES↗

TU-G-213-03: IEC Subcommittee 62C (Equipment for Radiotherapy, Nuclear Medicine and Radiation Dosimetry): Recent and Active Projects

The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists.

60 APPLIED LIFE SCIENCES↗

SU-E-T-265: Development of Dose-To-Water Conversion Models for Pre-Treatment Verification with the New AS1200 Imager

Purpose: To develop and evaluate models for dose verification of flattened (FF) and flattening filter free (FFF) beams for the new Varian aS1200 backscatter-shielded electronic portal imaging device (EPID). Methods: The model converts EPID images to incident energy fluence using deconvolution of EPID scatter kernels and fluence to dose in water using convolution with dose-to-water kernels. Model parameters were optimized using non-transmission EPID images of varying jaw defined field sizes for energies of 6 and 10 MV FF and FFF beams. Energy fluence was obtained from the Acuros planning system and reference dose profiles and output factors were measured at depths of 5, 10, 15 and 20 cm in a water phantom. Images for 34 IMRT fields acquired at 6 and 10 MV FF energy were converted to dose at 10 cm depth in water and compared to treatment planning system dose plane calculations using gamma criteria. Results: Gamma evaluations for the IMRT fields had mean (1 standard deviation) pass rates of 99.4% (0.8%) and mean gamma scores of 0.32 (0.06) with 2%, 2 mm criteria and 10% of maximum dose threshold. Conclusion: The developed model has been shown to be highly accurate for pre-treatment verification with the new aS1200 imager which does not display support-arm backscatter artefact and has improved dosimetric properties. Further investigation of FFF modes is in progress. The model is currently being evaluated at sites for potential clinical release.

60 APPLIED LIFE SCIENCES↗

SU-F-P-36: Automation of Linear Accelerator Star Shot Measurement with Advanced XML Scripting and Electronic Portal Imaging Device

Purpose: To verify a method used to automatically acquire jaw, MLC, collimator and couch star shots for a Varian TrueBeam linear accelerator utilizing Developer Mode and an Electronic Portal Imaging Device (EPID). Methods: An XML script was written to automate motion of the jaws, MLC, collimator and couch in TrueBeam Developer Mode (TBDM) to acquire star shot measurements. The XML script also dictates MV imaging parameters to facilitate automatic acquisition and recording of integrated EPID images. Since couch star shot measurements cannot be acquired using a combination of EPID and jaw/MLC collimation alone due to a fixed imager geometry, a method utilizing a 5mm wide steel ruler placed on the table and centered within a 15×15cm2 open field to produce a surrogate of the narrow field aperture was investigated. Four individual star shot measurements (X jaw, Y jaw, MLC and couch) were obtained using our proposed as well as traditional film-based method. Integrated EPID images and scanned measurement films were analyzed and compared. Results: Star shot (X jaw, Y jaw, MLC and couch) measurements were obtained in a single 5 minute delivery using the TBDM XML script method compared to 60 minutes for equivalent traditional film measurements. Analysis of the images and films demonstrated comparable isocentricity results, agreeing within 0.3mm of each other. Conclusion: The presented automatic approach of acquiring star shot measurements using TBDM and EPID has proven to be more efficient than the traditional film approach with equivalent results.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP4-02: An Investigation of Respiratory Surrogate Motion Data Requirements for Multiple-Step Ahead Prediction

Purpose: Respiratory-gated radiotherapy and dynamic tracking employ real-time imaging and surrogate motion-monitoring methods with tumor motion prediction in advance of real-time. This study investigated respiratory motion data length on prediction accuracy of tumor motion. Methods: Predictions generated from the algorithm are validated against a one-dimensional surrogate signal of amplitude versus time. Prediction consists of three major components: extracting top-ranked subcomponents from training data matching the last respiratory cycle; calculating weighting factors from best-matched subcomponents; fusing data proceeding best-matched subcomponents with respective weighting factors to form predictions. Predictions for one respiratory cycle (∼3-6seconds) were assessed using 351 patient data from the respiratory management device. Performance was evaluated for correlation coefficient and root mean square error (RMSE) between prediction and final respiratory cycle. Results: Respiratory prediction results fell into two classes, where best predictions for 70 cycles or less performed using relative prediction and greater than 70 cycles are predicted similarly using relative and derivative relative. For 70 respiratory cycles or less, the average correlation between prediction and final respiratory cycle was 0.9999±0.0001, 0.9999±0.0001, 0.9988±0.0003, 0.9985±0.0023, and 0.9981±0.0023 with RMSE values of 0.0091±0.0030, 0.0091±0.0030, 0.0305±0.0051, 0.0299±0.0259, and 0.0299±0.0259 for equal, relative, pattern, derivative equal and derivative relative weighting methods, respectively. Respectively, the total best prediction for each method was 37, 65, 20, 22, and 22. For data with greater than 70 cycles average correlation was 0.9999±0.0001, 0.9999±0.0001, 0.9988±0.0004, 0.9988±0.0020, and 0.9988±0.0020 with RMSE values of 0.0081±0.0031, 0.0082±0.0033, 0.0306±0.0056, 0.0218±0.0222, and 0.0218±0.0222 for equal, relative, pattern, derivative equal and derivative relative weighting methods, respectively. Respectively, the total best prediction for each method was 24, 44, 42, 30, and 45. Conclusion: The prediction algorithms are effective in estimating surrogate motion in advance. These results indicate an advantage in using relative prediction for shorter data and either relative or derivative relative prediction for longer data.

60 APPLIED LIFE SCIENCES↗

Comparison of Repositioning Accuracy of Two Commercially Available Immobilization Systems for Treatment of Head-and-Neck Tumors Using Simulation Computed Tomography Imaging

Purpose: To compare the setup accuracy, comfort level, and setup time of two immobilization systems used in head-and-neck radiotherapy. Methods and Materials: Between February 2004 and January 2005, 21 patients undergoing radiotherapy for head-and-neck tumors were assigned to one of two immobilization devices: a standard thermoplastic head-and-shoulder mask fixed to a carbon fiber base (Type S) or a thermoplastic head mask fixed to the Accufix cantilever board equipped with the shoulder depression system. All patients underwent planning computed tomography (CT) followed by repeated control CT under simulation conditions during the course of therapy. The CT images were subsequently co-registered and setup accuracy was examined by recording displacement in the three cartesian planes at six anatomic landmarks and calculating the three-dimensional vector errors. In addition, the setup time and comfort of the two systems were compared. Results: A total of 64 CT data sets were analyzed. No difference was found in the cartesian total displacement errors or total vector displacement errors between the two populations at any landmark considered. A trend was noted toward a smaller mean systemic error for the upper landmarks favoring the Accufix system. No difference was noted in the setup time or comfort level between the two systems. Conclusion: No significant difference in the three-dimensional setup accuracy was identified between the two immobilization systems compared. The data from this study reassure us that our technique provides accurate patient immobilization, allowing us to limit our planning target volume to <4 mm when treating head-and-neck tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-547: Off-Isocenter Winston-Lutz Test for Stereotactic Radiosurgery/stereotactic Body Radiotherapy

Purpose: To perform a quantitative study to verify that the mechanical field center coincides with the radiation field center when both are off from the isocenter during the single-isocenter technique in linear accelerator-based SRS/SBRT procedure to treat multiple lesions. Methods: We developed an innovative method to measure this accuracy, called the off-isocenter Winston-Lutz test, and here we provide a practical clinical guideline to implement this technique. We used ImagePro V.6 to analyze images of a Winston-Lutz phantom obtained using a Varian 21EX linear accelerator with an electronic portal imaging device, set up as for single-isocenter SRS/SBRT for multiple lesions. We investigated asymmetry field centers that were 3 cm and 5 cm away from the isocenter, as well as performing the standard Winston-Lutz test. We used a special beam configuration to acquire images while avoiding collision, and we investigated both jaw and multileaf collimation. Results: For the jaw collimator setting, at 3 cm off-isocenter, the mechanical field deviated from the radiation field by about 2.5 mm; at 5 cm, the deviation was above 3 mm, up to 4.27 mm. For the multileaf collimator setting, at 3 cm off-isocenter, the deviation was below 1 mm; at 5 cm, the deviation was above 1 mm, up to 1.72 mm, which is 72% higher than the tolerance threshold. Conclusion: These results indicated that the further the asymmetry field center is from the machine isocenter, the larger the deviation of the mechanical field from the radiation field, and the distance between the center of the asymmetry field and the isocenter should not exceed 3 cm in of our clinic. We recommend that every clinic that uses linear accelerator, multileaf collimator-based SRS/SBRT perform the off-isocenter Winston-Lutz test in addition to the standard Winston-Lutz test and use their own deviation data to design the treatment plan.

60 APPLIED LIFE SCIENCES↗

Percutaneous Intraluminal Recanalization of Long, Chronic Superficial Femoral and Popliteal Occlusions Using the Frontrunner XP CTO Device: A Single-Center Experience

The purpose of this study was to examine the safety and efficacy of the Frontrunner XP CTO (chronic total occlusion) Catheter (Cordis) for recanalization of long femoropopliteal artery occlusions. A Frontrunner catheter was used to treat 26 CTOs in SFA after guidewire failure (68.3 {+-} 8.8 years). Sixty-seven percent of patients had severe claudication. Critical lower limb ischemia with rest pain or minor tissue loss was present in three and eight patients, respectively. All the lesions were considered complex (TASC B, C, and D); 68% of the lesions were heavily calcified. The mean lesion length was 17.6 cm (range, 10-42 cm). The initial attempt to cross the occlusion with the CTO guidewire V18 was unsuccessful in 26 of 76 limbs (34.26%). A secondary attempt using the Frontrunner catheter (crossover approach, 27%; antegrade, 73%) performed in all 26 failed cases was successful in 17 limbs (65.38%), increasing the technical success rate to 88.12%. The main reasons for failure with the Frontrunner were inability to cross the lesion due to heavy calcification (six of nine) and inability to re-enter the true lumen after subintimal passage of the occluded segment (three of nine). The mean fluoroscopy time was 22.9 min. Minor complications included one distal extension of the dissection with involvement of the first popliteal segment and one perforation in the occluded segment. No major complications were seen. In conclusion, recanalization with the Frontrunner CTO catheter is a simple and safe method with a high technical success rate in the endovascular treatment of long superficial femoral artery occlusions and should be an alternative method after guidewire failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗