Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Generalized large optics fabrication multiplexing

High precision astronomical optics are manufactured through deterministic computer controlled optical surfacing processes, such as subaperture small tool polishing, magnetorheological finishing, bonnet tool polishing, and ion beam figuring. Due to the small tool size and the corresponding tool influence function, large optics fabrication is a highly time-consuming process. The framework of multiplexed figuring runs for the simultaneous use of two or more tools is presented. This multiplexing process increases the manufacturing efficiency and reduces the overall cost using parallelized subaperture tools.

36 MATERIALS SCIENCE↗

Tuning the Curie temperature of a two-dimensional magnet/topological insulator heterostructure to above room temperature by epitaxial growth

Heterostructures of two-dimensional (2D) van der Waals (vdW) magnets and topological insulators (TI) are of substantial interest as candidate materials for efficient spin-torque switching, quantum anomalous Hall effect, and chiral spin textures. However, since many of the vdW magnets have Curie temperatures below room temperature, we want to understand how materials can be modified to stabilize their magnetic ordering to higher temperatures. In this work, we utilize molecular beam epitaxy to systematically tune the Curie temperature (T C ) in thin film Fe 3 GeTe 2 /Bi 2 Te 3 from bulklike values (~220 K) to above room temperature by increasing the growth temperature from 300°C to 375°C. For samples grown at 375°C, cross-sectional scanning transmission electron microscopy (STEM) reveals the spontaneous formation of different Fe m Ge n Te 2 compositions (e.g., Fe 5 Ge 2 Te 2 and Fe 7 Ge 6 Te 2 ) as well as intercalation in the vdW gaps, which are possible origins of the enhanced Curie temperature. Furthermore, this observation paves the way for developing various Fe m Ge n Te 2 /TI heterostructures with novel properties.

36 MATERIALS SCIENCE↗

Entanglement-enhanced matter-wave interferometry in a high-finesse cavity

An ensemble of atoms can operate as a quantum sensor by placing atoms in a superposition of two different states. Upon measurement of the sensor, each atom is individually projected into one of the two states. Creating quantum correlations between the atoms, that is entangling them, could lead to resolutions surpassing the standard quantum limit set by projections of individual atoms. Large amounts of entanglement involving the internal degrees of freedom of laser-cooled atomic ensembles have been generated in collective cavity quantum-electrodynamics systems, in which many atoms simultaneously interact with a single optical cavity mode. Here we report a matter-wave interferometer in a cavity quantum-electrodynamics system of 700 atoms that are entangled in their external degrees of freedom. In our system, each individual atom falls freely under gravity and simultaneously traverses two paths through space while entangled with the other atoms. In this work, we demonstrate both quantum non-demolition measurements and cavity-mediated spin interactions for generating squeezed momentum states with directly observed sensitivity $3.4^{+1.1}_{–0.9}$dB and $2.5^{+0.6}_{–0.6}$dB below the standard quantum limit, respectively. We successfully inject an entangled state into a Mach–Zehnder light-pulse interferometer with directly observed sensitivity $1.7^{+0.5}_{–0.5}$dB below the standard quantum limit. The combination of particle delocalization and entanglement in our approach may influence developments of enhanced inertial sensors, searches for new physics, particles and fields, future advanced gravitational wave detectors and accessing beyond mean-field quantum many-body physics.

74 ATOMIC AND MOLECULAR PHYSICS↗

Electron Cooling Experiment for Proton Beams with Intense Space-Charge in IOTA

Electron cooling as a method of creating intense ion beams has a practical upper limit when it comes to the peak phase space density of ion beams which can be achieved in practice. We describe a new experiment to study electron cooling of 2.5 MeV protons at the intensity limit using the Integrable Optics Test Accelerator (IOTA), which is a storage ring dedicated to beam physics research at Fermilab. This system will enable the study of magnetized electron cooling of a proton beam with transverse incoherent tune shifts approaching -0.5 due to the presence of intense space-charge forces. We present an overview of the hardware design, simulations and specific experiments planned for this project.

43 PARTICLE ACCELERATORS↗

Optically pumped polarized 3 He ++ ion source development for RHIC/EIC

The proposed polarized 3 He ++ acceleration in RHIC and the future Electron-Ion Collider will require about 2×10 11 ions in the source pulse. A new technique had been proposed for production of high intensity polarized 3 He ++ ion beams. It is based on ionization and accumulation of the 3 He gas (polarized by metastability-exchange optical pumping and in the 5T high magnetic field) in the existing Electron Beam Ion Source (EBIS). A novel 3 He cryogenic purification and storage technique was developed to provide the required gas purity. An original gas refill and polarized 3 He gas injection to the EBIS long drift tubes, (which serves as the storage cell) were developed to ensure polarization preservation. An infrared laser system for optical pumping and polarization measurements in the high 3–5 T field has been developed. The 3 He polarization 80–85% (and sufficiently long ~30 min relaxation time) was obtained in the “open” cell configuration with refilling valve tube inlet and isolation valve closed. The development of the spin-rotator and 3 He 4 He absolute nuclear polarimeter at 6 MeV 3 He ++ beam energy is also presented here in this work.

43 PARTICLE ACCELERATORS↗

Electron-beam-based Compton scattering x-ray source for probing high-energy-density physics

The physics basis for an electron-beam-based Compton scattering x-ray source is investigated for single-shot experiments at the major high-energy-density facilities, such as the Omega Laser Facility, National Ignition Facility, and Z pulsed power facility. A source of monoenergetic ( δ ε / ε < 5 % ) 10- to 50-keV x rays can be produced by scattering of a short-pulse optical laser by a 23- to 53-MeV electron beam and collimating the scattered photons. The number and spectrum of scattered photons are calculated as a function of electron packet charge, electron and laser pulse duration, laser intensity, and collision geometry. A source delivering greater than 10 10 photons in a 1-mm-radius spot and 100-ps time resolution is plausible with the available electron gun and laser technology. Applications of this source for x-ray diffraction, x-ray imaging, x-ray absorption fine structure, and x-ray absorption spectroscopy in high-energy-density physics experiments are described, demonstrating significant advancements compared to the present state of the art. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗

Optical and microstructural studies of erbium-doped TiO 2 thin films on silicon, SrTiO 3 , and sapphire

Rare-earth ion doped oxide thin films integrated on silicon substrates provide a route toward scalable, chip-scale platforms for quantum coherent devices. Erbium-doped TiO 2 is an attractive candidate: the Er 3+ optical transition is compatible with C-band optical fiber communications, while TiO 2 is an insulating dielectric compatible with silicon process technology. Through structural and optical studies of Er-doped TiO 2 thin films grown via molecular beam deposition on silicon, SrTiO 3 , and sapphire substrates, we have explored the impact of polycrystallinity and microstructure on the optical properties of the Er emission. Comparing polycrystalline TiO 2 (rutile)/Si with single-crystalline TiO 2 (rutile)/r-sapphire and polycrystalline TiO 2 (anatase)/Si with single-crystalline TiO 2 (anatase)/SrTiO 3 , we observe that the inhomogeneous linewidth (Γ inh ) of the most prominent peak in the Er spectrum (the Y 1 –Z 1 transition, 1520 and 1533 nm in rutile and anatase TiO 2 ) is significantly narrower in the polycrystalline case. This implies a relative insensitivity to extended structural defects and grain boundaries in such films (as opposed to, e.g., point defects). We show that the growth of an undoped, underlying TiO 2 buffer on Si can reduce Γ inh by a factor of 4–5. Expectedly, Γ inh also reduces with decreasing Er concentrations: we observe a ∼2 order of magnitude reduction from ∼1000 ppm Er to ∼10 ppm Er. Γ inh then gets limited to a residual value of ∼5 GHz that is insensitive to further reduction in the Er concentration. Based upon the above results, we argue that the optical properties in these thin films are limited by the presence of high “grown-in” point defect concentrations.

Chemical elements↗

Fabrication of freeform potassium dihydrogen phosphate crystals by belt-on-wheel polishing for spatially tailored polarization control in high-power lasers

Large-aperture (>30 cm) optical components that provide spatially tailored control of the properties of a laser beam, such as phase, polarization, and amplitude, have been the focus of much research and development in recent years. Such optics can improve energy throughput and target implosion efficiency in high-power laser systems conducting inertial confinement fusion research. Here, a method is demonstrated for fabricating freeform surface topographies into the birefringent crystalline material, potassium dihydrogen phosphate (KDP). Belt-on-wheel polishing with an oil-based fluid, developed to mitigate the deliquescent properties of KDP, is used to deterministically polish a freeform topography into KDP, enabling the fabrication of a wave plate with spatially arbitrary retardance. Testing of the laser-induced damage threshold of belt-on-wheel polished KDP was conducted at a wavelength of 351 nm and a pulse duration of 1 ns. The results revealed that the polished surfaces are highly resistant to laser-induced damage, making them suitable for large-aperture, high-power laser applications.

Urban, Nathaniel D. [Univ. of Rochester, NY (Unite↗

Systems and methods for spatiotemporal control of a laser and applications of same

Methods and systems are disclosed for using a chromatic lens system to provide a “flying focus”—i.e., an advanced focusing scheme enabling spatiotemporal control of a focal location. In a method, a photon beam is emitted from a source at a wavelength. The photon beam may have more than one wavelength. The photon beam is focused to a focal location using a chromatic lens system. The focal location is at a first longitudinal distance along an optical axis from the chromatic lens system. The wavelength of the photon beam is changed as a function of time to change the focal location as a function of time. The wavelength may be changed such that the focal location changes with a focal velocity.

Froula, Dustin H.↗

Systems and methods for spatiotemporal control of a laser and applications of same

Methods and systems are disclosed for using a chromatic lens system to provide a “flying focus”—i.e., an advanced focusing scheme enabling spatiotemporal control of a focal location. In a method, a photon beam is emitted from a source at a wavelength. The photon beam may have more than one wavelength. The photon beam is focused to a focal location using a chromatic lens system. The focal location is at a first longitudinal distance along an optical axis from the chromatic lens system. The wavelength of the photon beam is changed as a function of time to change the focal location as a function of time. The wavelength may be changed such that the focal location changes with a focal velocity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Simons Observatory: HoloSim-ML: machine learning applied to the efficient analysis of radio holography measurements of complex optical systems

Near-field radio holography is a common method for measuring and aligning mirror surfaces for millimeter and sub-millimeter telescopes. In instruments with more than a single mirror, degeneracies arise in the holography measurement, requiring multiple measurements and new fitting methods. We present HoloSim-ML, a Python code for beam simulation and analysis of radio holography data from complex optical systems. This code uses machine learning to efficiently determine the position of hundreds of mirror adjusters on multiple mirrors with few micron accuracy. We apply this approach to the example of the Simons Observatory 6m telescope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Near-infrared noise in intense electron beams

Requirements for the noise in electron beams (NEB) have recently approached the Shot-noise level in some new applications. The density fluctuations of intense beams in the near-infrared (NIR) region are being measured at the Fermilab Accelerator Science and Technology (FAST) facility. The main goal of the experiment is to accurately compare the Shot-noise model with the observations of optical transition radiation (OTR) generated by the gamma=63 electron beam transiting an Al metal surface. In addition, evidence for longitudinal-space-charge-induced microbunching for the chicane-compressed beam was obtained with coherent enhancements up to 100 in the various bandwidth-filtered NIR OTR photodiode signals. With micropulse charges up to 1 nC, the beam parameters are close to those proposed for a stage in an Electron-Ion Collider (EIC) with coherent electron cooling (CEC). In this paper we present the current progress of the NEB project and compare the low electron energy measurements with ImpactX simulations.

43 PARTICLE ACCELERATORS↗

A Wide Dynamic-Range Halo Monitor for 8 GeV Proton Beams at FNAL

Eliminating harmful beam halos is the most important technique for high-intensity proton accelerators. Therefore, beam halo diagnosis is indispensable and becomes more and more important. At J-PARC, a wide dynamic range monitor was installed in the beam transport line in 2012. The device is a two-dimensional beam profile monitor [*, **], and it has a dynamic range of approximately six digits of magnitude by using Optical Transition Radiation and fluorescence screens. The FNAL accelerator complex has been upgrading through increased beam intensity and beam quality. A new beam halo diagnostic device is required in the beam transport line between the booster and recycler. It will be manufactured in a collaboration between J-PARC and FNAL as a part of the U.S.-Japan Science and Technology Cooperation Program in High Energy Physics. We are redesigning the monitor to satisfy FNAL specifications for beam energy, intensity, and size. The equipment will be manufactured at J-PARC and then shipped to FNAL in 2024. In this report, the design of the device will be described.

43 PARTICLE ACCELERATORS↗

Seedless nonresonant gas-flow velocimetry with single-shot coherent Rayleigh-Brillouin scattering

We demonstrate neutral gas-flow velocimetry by exploiting the optical dipole forces exerted by precisely tailored high-intensity laser fields on polarizable particles, in the form of single-shot coherent Rayleigh-Brillouin scattering (CRBS). This enables mapping of the velocity distribution function of the particles in a single laser shot of approximately 200 ns duration, allowing us to perform spectroscopic measurements in the time, rather than the frequency, domain. Importantly, CRBS results in a coherent signal beam, which renders the technique ideal for measurements in optically noisy environments. By correlating the time shift of the resulting spectrum to the Doppler shift caused by the bulk motion of particles, we perform neutral gas-flow velocimetry without the need to seed the flow, nondestructively, for a variety of gases, atomic or molecular. We demonstrate gas-flow velocimetry at flow velocities as low as 1 m ⁢s −1 , with similar velocity resolution, while temperature and gas density can also be estimated from the same single-shot spectra. To prove the effectiveness of the measurement technique, we benchmark it against Pitot tube measurements, which show excellent agreement.

Gerakis, Alexandros [Luxembourg Institute of Scien↗

High-power non-perturbative laser delivery diagnostics at the final focus of 100-TW-class laser pulses

Controlling the delivery of multi-terawatt and petawatt laser pulses to final focus, both in position and angle, is critical to many laser applications such as optical guiding, laser–plasma acceleration, and laser-produced secondary radiation. We present an online, non-destructive laser diagnostic, capable of measuring the transverse position and pointing angle at focus. The diagnostic is based on a unique double-surface-coated wedged-mirror design for the final steering optic in the laser line, producing a witness beam highly correlated with the main beam. By propagating low-power kilohertz pulses to focus, we observed spectra of focus position and pointing angle fluctuations dominated by frequencies below 70 Hz. The setup was also used to characterize the excellent position and pointing angle correlation of the 1 Hz high-power laser pulses to this low-power kilohertz pulse train, opening a promising path to fast non-perturbative feedback concepts even on few-hertz-class high-power laser systems.

47 OTHER INSTRUMENTATION↗

Collective plasma effects of electron–positron pairs in beam-driven QED cascades

Understanding the interplay of strong-field QED and collective plasma effects is important for explaining extreme astrophysical environments like magnetars. It has been shown that QED pair plasma can be produced and observed by passing a relativistic electron beam through an intense laser field. This work presents in detail multiple sets of 3D QED-particle-in-cell simulations to show the creation of pair plasma in the QED cascade. The beam driven method enables a high pair particle density and also a low particle Lorentz factor, which both play equal roles on exhibiting large collective plasma effects. Finite laser frequency upshift is observed with both ideal parameters (24 PW laser colliding with a 300 GeV electron beam) and with existing technologies (3 PW laser colliding with a 30 GeV electron beam).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The effects of pre-plasma scale length on the relativistic electron beam directionality

The effects of pre-plasmas on the electron beam directionality was experimentally and numerically investigated. Single material and layered targets made of Ti and/or CH were used to simultaneously measure high-energy (≥3 MeV) electrons along two directions, pre-pulse energy and pre-plasma density. The electron directionality is quantified by using a new parameter, the electron energy ratio of the total kinetic energies along the two directions. Measurements and radiation–hydrodynamic (RH) simulations show that a large (≥3.5 μm) plasma scale length at the critical surface enhances electrons along the laser axis, and such pre-plasma conditions could only be achieved with the CH targets. Particle-in-cell simulations were performed on the RH generated pre-plasmas from Ti and CH targets, and the results show that the CH target provided conditions for higher forward momentum gains by electrons. First, the CH target allowed longer distances for electrons to interact with laser. Second, the intense laser pulse modified the critical surface, but the resulting surface differed. The CH target resulted in a smooth surface where a retro-reflection was observed while the Ti target resulted in a rippled surface that scattered the reflected light. As results, the CH electrons gained higher forward momentum via a direct-laser-acceleration in the counter propagating laser fields. So the results presented in this article show a way of controlling the high-energy electron directionality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A long path-length optical property measurement device for highly transparent detector media

Measurements of the optical properties of highly transparent liquids are necessary for large-scale detectors that seek to detect optical signatures in kiloton-scale or larger volumes. Detailed understanding of the attenuation and scattering properties of fill media is critical to the ability to accurately simulate detector performance, and yet is often unavailable until in-situ measurements can be performed. Moreover, in-situ measurements may rely on effective attenuation lengths or other approximations to characterize performance, rather than absolute measurements of attenuation and scattering. To better understand the optical properties of potential fill media and purification schemes, a system has been developed which provides simultaneous attenuation and differential scattering cross-section measurements for highly transparent liquids. This horizontal, adjustable path-length “long-arm” system provides excellent isolation from the atmosphere, a high degree of vibration insensitivity, and a simple and reliable method of calibration. Further, scattering measurements can be carried out simultaneously at ports along the beamline equipped with optics allowing the selection of scatter angle and polarization. This enables both reliable quantitative scatter measurements and phase-function separation. This system has been extensively tested using deionized (DI) water as a benchmark, and has demonstrated repeatable measurements of attenuation lengths exceeding 100 m and scattering lengths approaching 1 km.

47 OTHER INSTRUMENTATION↗