Uncertainty quantification for virtual diagnostic of particle accelerators
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
The charge exchange recombination spectroscopy system (CXRS) for ITER is designed to measure the core helium concentration, and in addition, profiles of ion temperature and rotation. This highly demanding task, due to the huge background radiation (bremsstrahlung) and the high attenuation of the dedicated diagnostic neutral beam, requires high throughput spectrometers with high resolution. On TEXTOR, a CXRS system has been developed with the aim to test the physics implications of these specifications. (i) A relevant spectrometer has been tested. (ii) A method to determine the helium concentrations from the CXRS intensity, using the beam emission has been evaluated. A 20% discrepancy in beam emission was revealed. (iii) The determination of the magnetic pitch angle by the ratio of Balmer lines showed qualitatively the right behavior, although the accuracy was limited by the polarization sensitivity of the first mirror. (iv) The simulation code developed for the prediction of the CXRS spectra was quantitatively confronted with experimental data.
Many laser-based high-energy-density science (HEDS) facilities have one or more short-pulse (sub- to few-picosecond) laser beams for diagnostics. For the past decade, we have been developing a novel x-ray probing capability using such picosecond lasers interacting with an underdense plasma to produce relativistic electrons. The ultimate goal of these experiments is to demonstrate a new type of x-ray backlighter using the short-pulse ARC laser at the National Ignition Facility (NIF). Before this diagnostic is fielded at the NIF, it is critical to demonstrate the viability and reproducibility of the x-ray source on comparable high-power short-pulse laser systems. We present experiments that were carried out with the OMEGA EP laser at the University of Rochester’s laboratory for laser energetics. In these experiments, high-energy electrons are produced through a combination of the self-modulation instability and direct laser acceleration in an underdense gas jet. These electrons generate directional x-rays with characteristic energies up to several tens of keV as they execute betatron motion in the ion channel, and the inverse Compton scattering process generates even harder x-rays, with characteristic photon energies of 60–240 keV. When implemented on the OMEGA EP laser(s), this x-ray source yields results that are comparable to those obtained recently on the short-pulse Titan laser at the Jupiter Laser Facility at Lawrence Livermore National Laboratory, after accounting for differences in laser energy, peak intensity, focusing f/#, and plasma source. Applications of such an x-ray source for HEDS experiments are discussed.
We report on a single-shot longitudinal phase-space reconstruction diagnostic for electron beams in a laser wakefield accelerator via the experimental observation of distinct periodic modulations in the angularly resolved spectra. Such modulated angular spectra arise as a result of the direct interaction between the ultrarelativistic electron beam and the laser driver in the presence of the wakefield. A constrained theoretical model for the coupled oscillator, assisted by a genetic algorithm, can recreate the experimental electron spectra and, thus, fully reconstructs the longitudinal phase-space distribution of the electron beam with a temporal resolution of approximately 1.3 fs. In particular, it reveals the slice energy spread of the electron beam, which is important to measure for applications such as x-ray free electron lasers. In our experiment, the root-mean-square energy spread retrieved is bounded at 9.9 MeV, corresponding to a 0.9%–3.0% relative spread, despite the overall GeV energy beam having approximately 100% relative energy spread.
Neutral beams based on positive ion source technology are a key component of contemporary fusion research. An accurate assessment of the injected beam species mix is important for determining the actual plasma heating and momentum input as well as proper interpretation of beam-based diagnostics. On DIII-D, the main ion charge-exchange spectroscopy system is used to extract well-resolved intensity ratios of the Doppler-shifted D{sub {alpha}} emission from the full, half, and third energy beam components for a variety of beam operational parameters. In conjunction with accurate collisional-radiative modeling, these measurements indicate the assumed species mix and power fractions can vary significantly and should be regularly monitored and updated for the most accurate interpretation of plasma performance. In addition, if stable active control of the power fractions can be achieved through appropriate source tuning, the resulting control over the deposition profile can serve as an additional experimental knob for advanced tokamak studies, e.g., varying the off axis beam current drive without altering the beam trajectory.
As a part of ITER beam aided diagnostics, the design of Motional Stark Effect (MSE) diagnostic observing the emission from the Balmer-α line is underway. The physics of Stark splitting shows that the Stark manifold is polarization dependent, and the energy splitting results in a line shift proportional to the electric field. Due to the challenges of maintaining the calibration of the plasma facing mirrors in ITER, the conventional MSE polarimetry measurement technique is replaced with a spectral approach that is deemed more favorable in the ITER environment. The MSE line shift (LS) diagnostic is designed to quantify the Lorentz electric field magnitude by measuring the Stark manifold using visible spectroscopy. In the presence of large magnetic fields and high energy heating beams of 1 MeV, the expected Stark splitting is much larger than in typical devices. The MSE-LS design has unique challenges requiring careful consideration and modeling of its viewing geometry and photon budget. The MSE-LS approach on ITER is promising but has stringent demands on the allowable errors for the statistical and systematic fitting uncertainties. In this study, a full system model and numerical simulations of data for each sightline are completed. For a range of optical transmission fractions, photon noise analysis is conducted to determine the statistical uncertainties. This provides guidance on the spectrometer throughput, dispersion at the detector, optics, and other design choices. A conceptual design of a high throughput spectrometer with a volume phase transmission grating is presented.
A feasibility study for the use of core charge exchange recombination spectroscopy on ITER has shown that accurate measurements on the helium ash require a spectrometer with a high etendue of 1mm{sup 2}sr to comply with the measurement requirements [S. Tugarinov et al., Rev. Sci. Instrum. 74, 2075 (2003)]. To this purpose such an instrument has been developed consisting of three separate wavelength channels (to measure simultaneously He/Be, C/Ne, and H/D/T together with the Doppler shifted direct emission of the diagnostic neutral beam, the beam emission (BES) signal), combining high dispersion (0.02 nm/pixel), sufficient resolution (0.2 nm), high efficiency (55%), and extended wavelength range (14 nm) at high etendue. The combined measurement of the BES along the same sightline within a third wavelength range provides the possibility for in situ calibration of the charge eXchange recombination spectroscopy signals. In addition, the option is included to use the same instrument for measurements of the fast fluctuations of the beam emission intensity up to 2 MHz, with the aim to study MHD activity.
Not Available
Neutron resonance spectroscopy (NRS) has been used extensively to make temperature measurements that are accurate, absolute, and nonperturbative within the interior of material samples under extreme conditions applied quasistatically. Yet NRS has seldom been used in dynamic experiments. There is a compelling incentive to do so because of the significant shortcomings of alternative techniques. An important barrier to adopting dynamic NRS thermometry is the difficulty in fielding it with conventional spallation neutron sources. To enable time-dependent and spatially resolved temperature measurements in dynamic environments, more compact neutron sources that can be used at user facilities in conjunction with other diagnostic probes (such as x-ray light sources) are required. Such sources may be available using ultrafast high-intensity optical lasers. We evaluate such possibilities by determining the sensitivities of the temperature estimate on neutron-beam and diagnostic parameters. Based on that evaluation, requirements are set on a pulsed neutron-source and diagnostics to make a meaningful dynamic temperature measurement. Dynamic thermometry measurements are examined in this context when driven by two alternative fast-neutron sources: the Los Alamos Neutron Scattering Center (LANSCE) proton accelerator driving isotropic spallation neutrons as a baseline and a laser-plasma ion accelerator driving a neutron beam from deuterium breakup. Strategies to close the gap between the required and demonstrated performance of laser-based fast-neutron sources are presented. A short-pulse high-intensity laser with state-of-the-art pulse contrast and an energy of a few hundred Joules would drive a compact neutron source suitable for NRS thermometry that could transform the dynamic study of materials.
The beam-profile diagnostics station prototype for the superconducting rf electron linac being constructed at Fermilab at the New Muon Lab has been tested. The station uses intercepting radiation converter screens for the low-power beam mode: either a 100-{micro}m thick YAG:Ce single crystal scintillator or a 1-{micro}m thin Al optical transition radiation (OTR) foil. The screens are oriented with the surface perpendicular to the beam direction. A downstream mirror with its surface at 45 degrees to the beam direction is used to direct the radiation into the optical transport. The optical system has better than 20 (10) {micro}m rms spatial resolution when covering a vertical field of view of 18 (5) mm. The initial tests were performed at the A0 Photoinjector at a beam energy of {approx}15 MeV and with micropulse charges from 25 to 500 pC for beam sizes of 45 to 250 microns. Example results will be presented.
The beam spatial structure of a diode-side-pumped Nd:YVO{sub 4} slab laser with grazing-incidence bounce geometry is studied. It is found how the mode structure changes with changing the cavity parameters in the cw and active Q-switching regimes. The parameters that allow one to improve the output beam quality retaining high output laser power are found. (control of laser radiation parameters)
Performance of a compact He{sup +} ion source was investigated before installing it to the experiment system developed for studying the efficiency of autodetachment neutralization from He{sup -} to He{sup 0}. Dependence of the extracted ion current upon the plasma parameters and that upon the extraction voltage indicated that the source performance was limited by space charge effect. The beam emittance was measured with a multislit system for various operation conditions. The experimentally determined emittance agreed well with the emittance obtained from ion trajectories calculated with input plasma parameters measured by a Langmuir probe. The beam current density of 60 mA/cm{sup 2} and the emittance of less than 25{pi} mm mrad are expected to deliver enough current to the downstream of the He{sup -} neutralizer system to clarify factors affecting the final He{sup 0} intensity.
Not Available
The Coherent Electron Cooling requires small energy spread and uniformity of energy along the bunch. The diagnostics line is utilized for the measurement of the electron beam parameters. The beamline layout is shown in Fig. 1. Three quadrupoles after the linac are used to match beam into the common section. The main dipole is used to deflect beam towards common section. If it is switched off the beam goes to the diagnostics line. The beam optics in the diagnostics line is controlled by four quadrupoles. The deflecting cavity sweeping beam in the vertical direction follows the quadrupoles. Sector dipole is used for energy parameters measurement. It has deflection angle of 30 degrees. With diagnostics dipole switched off the beam propagated to the insertable slits system for emittance measurement. There are four profile monitors in the line, The first profile monitor (ACC YAG) is after the main dipole. The second profile monitor (YAG3) is in front of the diagnostics dipole after the deflecting cavity. YAG1 profile monitor is placed after the slits, and YAG2 profile monitor is placed after the diagnostics dipole. There is a solenoid between the deflecting cavity and YAG3. It is used for the beam energy measurement.
This diagnostic measures temperature, density, and rotation for the fully stripped boron ion between the pedestal top and the plasma core with resolution consistent with the profile gradients. The diagnostic neutral beam used for the measurements generates a 50 keV, 6 A hydrogen beam. The optical systems provide views in both poloidal and toroidal directions. The imaging spectrometer is optimized to simultaneously accept 45 views as input with minimum cross-talk. In situ calibration techniques are applied for spatial location, spectral intensity, and wavelength. In the analysis, measured spectra are fitted to a model constructed from a detailed description of the emission physics. Methods for removal of interfering spectra are included. Applications include impurity and thermal transport.
Synchrotron radiation (SR) from bending magnets, wigglers, and undulators is now extensively produced for users at storage ring based light sources, with unique properties in terms of average brightness and stability. Here, we present a profound study of bending magnet SR intensity distribution in the image plane of a focusing optical system. Measurements of this intensity distribution at the MAX-IV low emittance storage ring are compared to theoretical predictions, and found to be in excellent agreement. This work shows upon the possibility of performing high resolution emittance diagnostics with visible or near-visible SR on upcoming low-emittance storage ring based light sources. As a byproduct of our study, we derive a closed analytical expression for the intensity distribution from a zero-emittance beam, in the limiting case of wide orbital collection angles. This expression finally allows us to demonstrate the meeting between classical electrodynamics applied to SR emission and focusing, and the Landau and Lifshitz prediction of radiation intensity distribution nearby a caustic.
One of the main charges of beam physics is to improve the overall beam quality delivered to experiments and applications, which is generally quantified by the beam brightness. High brightness beams have numerous applications, including x-ray free electron lasers and ultrafast electron diffraction (UED). To these ends, this thesis details efforts to use high-performance models --- high-fidelity models that execute quickly --- for controls and diagnostics. To demonstrate the generality of these techniques, this thesis focuses on three of the most successful photoinjector designs currently used worldwide: the UCLA/SLAC/BNL-type high-gradient S-band gun, the continuous-wave high-repetition rate VHF APEX gun and the L-band DESY-PITZ-type gun. Work will be shown from Pegasus (UCLA), HiRES (LBNL) and FAST (FNAL).Specifically, data-driven models for online virtual diagnostics are presented, in this case, in the context of UED at HiRES, leading to a temporal resolution improvement. Methods for improving the fidelity of physics-based models are discussed, with examples at HiRES, Pegasus and FAST. Markov-chain Monte Carlo analysis is applied to match simulations, in the context of photocathode studies at HiRES and Pegasus. Lastly, the augmentation of online model-based predictions with model-independent optimization is explored in a fluctuating environment at Pegasus and HiRES. A central theme of this dissertation is working with parameter fluctuations when modeling an accelerator beamline. Long-term drifts and shot-to-shot jitter exist in every accelerator to a varying degree and therefore play an important role in every chapter of this dissertation. This thesis attempts to address the issues associated with these fluctuations when trying to develop faithful model representations of the system.
In a scope of a collaboration between Thales Communications and Security and CEA DAM DIF, 11 keV Xrays were produced by inverse Compton scattering on the ELSA facility. In this type of experiment, X-ray observation lies in the use of accurate electron and laser beam interaction diagnostics and on fitted X-ray detectors. The low interaction probability between < 100 {mu}m width, 12 ps [rms] length electron and photon pulses requires careful optimization of pulse spatial and temporal covering. Another issue was to observe 11 keV X-rays in the ambient radioactive noise of the linear accelerator. For that, we use a very sensitive detection scheme based on radio luminescent screens.