Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “balance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

H2O heating in molecular clouds - Line transfer and thermal balance in a warm dusty medium

An investigation is undertaken into the possibility of the heating of molecular gas through collisions with radiatively pumped H2O, in the context of the overall thermal balance of optically thick molecular clouds with embedded sources. In order to solve the line transfer equation, which includes warm dust grains, an extended method of escape probability approximation is developed in which the equilibrium gas temperature arises from the balance of heating by cosmic ray ionization of H2, and by collisions with warm dust grains and radiatively pumped H2O molecules against cooling by collisions with CO and C I. The equilibrium gas temperature for a given dust temperature strongly depends on the efficiency of the cooling species, and is therefore most sensitive to the cloud optical depth. It is less dependent, in decreasing order, on H2O abundance, gas density, and velocity dispersion.

Takahashi, T.↗

Roles of divergent and rotational winds in the kinetic energy balance during intense convective activity

Contributions of divergent and rotational wind components to the synoptic-scale kinetic energy balance are described using rawinsonde data at 3 and 6 h intervals from NASA's fourth Atmospheric Variability experiment. Two intense thunderstorm complexes occurred during the period. Energy budgets are described for the entire computational region and for limited volumes that enclosed storm-induced, upper level wind maxima located poleward of convection. Although small in magnitude, the divergent wind component played an important role in the cross-contour generation and horizontal flux divergence of kinetic energy. The importance of V(D) appears directly related to the presence and intensity of convection. Although K(D) usually comprised less than 10 percent of the total kinetic energy content, generation of kinetic energy by V(D) was a major factor in the creation of upper-level wind maxima to the north of the storm complexes. Omission of the divergent wind apparently would lead to serious misrepresentations of the energy balance. A random error analysis is presented to assess confidence limits in the various energy parameters.

Fuelberg, H. E.↗

The balance of kinetic and total energy simulated by the OSU two-level atmospheric general circulation model for January and July

A three-year simulation which prescribes seasonally varying solar radiation and sea surface temperature is the basis of the present study of the horizontal structure of the balances of kinetic and total energy simulated by Oregon State University's two-level atmospheric general circulation model. Mechanisms responsible for the local energy changes are identified, and the energy balance requirement's fulfilment is examined. In January, the vertical integral of the total energy shows large amounts of external heating over the North Pacific and Atlantic, together with cooling over most of the land area of the Northern Hemisphere. In July, an overall seasonal reversal is found. Both seasons are also characterized by strong energy flux divergence in the tropics, in association with the poleward transport of heat and momentum.

Wang, J.-T.↗

Meridional energy balance of Jupiter

The meridional energy balance of Jupiter is calculated from high spatial resolution observations by the Voyager 1 infrared spectrometer and radiometer. On a hemispheric scale Jupiter radiates thermal energy to space approximately uniform with latitude while solar energy absorption varies approximately as the solar angle. This implies internal adjustment to the solar energy with a larger contribution poleward of + or - 45 deg than in the equatorial zone. The internal flux is modulated by the major visible features of the zone and belt system but, unlike the hemispheric scale where increased internal flux is correlated with decreased solar absorption, on smaller scales the inverse occurs. The energy balance is very likely to be controlled by dynamics, but the relative influence of the upper atmosphere and the interior is not yet clear.

Pirraglia, J. A.↗

Microprocessor-Controlled Laser Balancing System

Material removed by laser action as part tested for balance. Directed by microprocessor, laser fires appropriate amount of pulses in correct locations to remove necessary amount of material. Operator and microprocessor software interact through video screen and keypad; no programing skills or unprompted system-control decisions required. System provides complete and accurate balancing in single load-and-spinup cycle.

Demuth, R. S.↗

Global carbon - nitrogen - phosphorus cycle interactions: A key to solving the atmospheric CO2 balance problem?

If all biotic sinks of atmospheric CO2 reported were added a value of about 0.4 Gt C/yr would be found. For each category, a very high (non-conservative) estimate was used. This still does not provide a sufficient basis for achieving a balance between the sources and sinks of atmospheric CO2. The bulk of the discrepancy lies in a combination of errors in the major terms, the greatest being in a combination of errors in the major terms, the greatest being in the net biotic release and ocean uptake segments, but smaller errors or biases may exist in calculations of the rate of atmospheric CO2 increase and total fossil fuel use as well. The reason why biotic sinks are not capable of balancing the CO2 increase via nutrient-matching in the short-term is apparent from a comparison of the stoichiometry of the sources and sinks. The burning of fossil fuels and forest biomass releases much more CO2-carbon than is sequestered as organic carbon.

Peterson, B. J.↗

Testing an Energy Balance Model for Estimating Actual Evapotranspiration Using Remotely Sensed Data

An energy-balance model is used to estimate daily evapotranspiration for 3 days for a barley field and a wheat field near Hannover, Federal Republic of Germany. The model was calibrated using once-daily estimates of surface temperatures, which may be remotely sensed. The evaporation estimates were within the 95% error bounds of independent eddy correlation estimates for the daytime periods for all three days for both sites, but the energy-balance estimates are generally higher; it is unclear which estimate is biassed. Soil moisture in the top 2 cm of soil, which may be remotely sensed, may be used to improve these evaporation estimates under partial ground cover. Sensitivity studies indicate the amount of ground data required is not excessive.

Gurney, R. J.↗

Rotary-balance experiments on a modern fighter aircraft configuration at high Reynolds numbers

NASA Ames Research Center's research program to investigate high-angle-of-attack aerodynamic phenomena associated with high-performance aircraft includes the development and use of rotary balance apparatuses for wind balance apparatuses for wind tunnel tests of airplane models in a coning motion. A large scale apparatus, developed for testing models at high Reynolds numbers in the Ames 12-Foot Pressure Wind Tunnel, was recently tested with an 0.05-scale F-15 fighter model. Measurements were made at low subsonic Mach numbers and chord Reynolds numbers of 1 to 5.5 million, with angles of attack from 0 to 90 deg and sideslip angles from -15 to +15 deg. Effects of Reynolds number, spin-rate parameter, model attitude, presence of a nose boom, and model/sting mounting angle were investigated.

Malcolm, G. N.↗

Two-Axis, Self-Nulling Skin-Friction Balance

Two-dimensional aerodynamic skin-friction force measured directly. Disk-shaped prototype design has overall dimensions of 1.25 (3.18 centimeters) diameter and 0.5 inch (1.27 centimeters) height. Unique mechanism consisting of two flexural pivoted arms connected in tandem but at right angle with each other designed to impart plane motion needed to sense two-axis flow over sensing element of balance. Sensing element, 0.370 inch (0.940 centimeter) in diameter, attached to end of second arm is servoed by two restoring-force motors orthogonally mounted in plane of airflow. Mechanism allows free plane motion of sensing element with no friction, and balance self-nulled to provide direct plane skin-friction force measurements continuously.

Tcheng, P.↗

Balancing High-Speed Rotors at Low Speed

Flexible balancing reduces vibrations at operating speeds. Highspeed rotors in turbomachines dynamically balanced at fraction of operating rotor speed. New method takes into account rotor flexible rather than rigid.

Giordano, J.↗

Heat balances of the surface mixed layer in the equatorial Atlantic and Indian Ocean during FGGE

Surface meteorological and surface and subsurface oceanographic data collected during FGGE in the equatorial Atlantic and Indian Oceans are used to estimate the terms in a heat balance relation for the mixed layer. The first balance tested is between changes in mixed layer temperature (MLT) and surface energy fluxes. Away from regions of low variance in MLT time series and equatorial and coastal upwelling, surface fluxes can account for 75 percent of the variance in the observed time series. Differences between observed and estimated MLTs indicate that on the average, maximum errors in surface flux are of the order of 20 to 30 W/sq m. In the Atlantic, the addition of zonal advection does not significantly improve the estimates. However in regions of equatorial upwelling, the eastern Atlantic vertical mixing and meridional advection can play an important role in the evolution of MLTs.

Molinari, R. L.↗

Performance tradeoffs in static and dynamic load balancing strategies

The problem of uniformly distributing the load of a parallel program over a multiprocessor system was considered. A program was analyzed whose structure permits the computation of the optimal static solution. Then four strategies for load balancing were described and their performance compared. The strategies are: (1) the optimal static assignment algorithm which is guaranteed to yield the best static solution, (2) the static binary dissection method which is very fast but sub-optimal, (3) the greedy algorithm, a static fully polynomial time approximation scheme, which estimates the optimal solution to arbitrary accuracy, and (4) the predictive dynamic load balancing heuristic which uses information on the precedence relationships within the program and outperforms any of the static methods. It is also shown that the overhead incurred by the dynamic heuristic is reduced considerably if it is started off with a static assignment provided by either of the other three strategies.

Iqbal, M. A.↗

Cryogenic strain gage techniques used in force balance design for the National Transonic Facility

A force balance is a strain gage transducer used in wind tunnels to measure the forces and moments on aerodynamic models. Techniques have been established for temperature-compensation of force balances to allow their use over the operating temperature range of a cryogenic wind tunnel (-190C to 60C) without thermal control. This was accomplished by using a patented strain gage matching process to minimize inherent thermal differences, and a thermal compensation procedure to reduce the remaining thermally-induced outputs to acceptable levels. A method of compensating for mechanical movement of the axial force measuring beam caused by thermally-induced stresses under transient temperatures was also included.

Ferris, A. T.↗

Analysis of a resistance-energy balance method for estimating daily evaporation from wheat plots using one-time-of-day infrared temperature observations

Accurate estimates of evaporation over field-scale or larger areas are needed in hydrologic studies, irrigation scheduling, and meteorology. Remotely sensed surface temperature might be used in a model to calculate evaporation. A resistance-energy balance model, which combines an energy balance equation, the Penman-Monteith (1981) evaporation equation, and van den Honert's (1948) equation for water extraction by plant roots, is analyzed for estimating daily evaporation from wheat using postnoon canopy temperature measurements. Additional data requirements are half-hourly averages of solar radiation, air and dew point temperatures, and wind speed, along with reasonable estimates of canopy emissivity, albedo, height, and leaf area index. Evaporation fluxes were measured in the field by precision weighing lysimeters for well-watered and water-stressed wheat. Errors in computed daily evaporation were generally less than 10 percent, while errors in cumulative evaporation for 10 clear sky days were less than 5 percent for both well-watered and water-stressed wheat. Some results from sensitivity analysis of the model are also given.

Choudhury, B. J.↗

Hydraulic Calibrator for Strain-Gauge Balances

Instrument for calibrating strain-gauge balances uses hydraulic actuators and load cells. Eliminates effects of nonparallelism, nonperpendicularity, and changes of cable directions upon vector sums of applied forces. Errors due to cable stretching, pulley friction, and weight inaccuracy also eliminated. New instrument rugged and transportable. Set up quickly. Developed to apply known loads to wind-tunnel models with encapsulated strain-gauge balances, also adapted for use in calibrating dynamometers, load sensors on machinery and laboratory instruments.

Skelly, Kenneth↗

Mass and energy balance of the cold Io torus

A new model of the cold Io torus is described. Ions and energy are injected into the system by independent processes so that the mass balance is isolated from the energy balance. The primary source of energy is local ionization and acceleration of hot pickup ions resulting from charge exchange between thermal ions and an extended cloud of Iogenic sulfur and oxygen atoms. The primary energy loss mechanism of the plasma is collisionally excited line emission at optical wavelengths. The primary ion source is radial diffusion inward from the hot torus on a time scale of 140-710 days. The primary ion loss mechanism is a novel two-step enhanced recombination mechanism involving charge exchange between thermal ions and an extended cloud of neutral SO2 molecules, followed by rapid dissociative recombination of the resultant molecular ion. The model provides a self-consistent solution which reconciles a number of diverse observations with known physical processes.

Moreno, M. A.↗

On the radiative balance of the stratosphere

The zonally averaged radiative balance of the stratosphere based on the measured temperature structure and gas concentrations available from the LIMS instrument is examined in detail. These data are extant for seven months (November 1978 to May 1979). The contribution to the net radiative balance due to the individual components of solar heating and longwave cooling is discussed. These components are further broken down by individual gas constituent to understand the role each gas plays in determining the total radiative heating/cooling. The deficiencies of employing a latitudinally and temporally independent Newtonian damping coefficient are also explored. In particular, the Newtonian damping time is shown to vary by a factor of two in both latitude and season. Net zonally averaged stratospheric radiative heating for the seven months of LIMS data are presented. These net heating rates are important in determining the role of advective transport of chemical constituents. An important feature that appears in the derived radiative heating is the existence of a region of net radiative cooling near the equatorial stratopause.

Kiehl, J. T.↗

Diagnostic analysis of two-dimensional monthly average ozone balance with Chapman chemistry

Chapman chemistry has been used in a two-dimensional model to simulate ozone balance phenomenology. The similarity between regions of ozone production and loss calculated using Chapman chemistry and those computed using LIMS and SAMS data with a photochemical equilibrium model indicate that such simplified chemistry is useful in studying gross features in stratospheric ozone balance. Net ozone production or loss rates are brought about by departures from the photochemical equilibrium (PCE) condition. If transport drives ozone above its PCE condition, then photochemical loss dominates production. If transport drives ozone below its PCE condition, then photochemical production dominates loss. Gross features of ozone loss/production (L/P) inferred for the real atmosphere from data are also simulated using only eddy diffusion. This indicates that one must be careful in assigning a transport scheme for a two-dimensional model that mimics only behavior of the observed ozone L/P.

Stolarski, Richard S.↗