Fundamental Equations of the LIF Hydroxyl Measurements, Appendix a

The equation relating OH concentration to the observed detector count rate for a given laser flux is defined. That equation, which will be referred to henceforth as the central equation for absolute sensitivity, will be cast in terms of standard spectroscopic quantities such as oscillator strengths, Hoenl-London factors, rotational and vibrational quantum numbers, etc., such that it may be tested directly under laboratory conditions. The working expressions used by each of the OH laser induced fluorescence (LIF) groups will be related to this central equation, thereby establishing a common language for the comparison of experimental results and the definition of LIF system performance. The relevant structural details of the OH radical via a spectroscopic description of the energy levels and transitions employed in the LIF method are detailed. The central equation relating observed count rate to absolute concentration will be derived, and that equation will be related to the observed quantities cited by each of the experimental groups engaged in the measurement of OH in the Earth's atmosphere.

Source record↗

Saturation Phenomena in LIF Measurements, Appendix B

Optical saturation is the phenomenon in which the laser-induced rates of absorption and spontaneous emission between two levels, induced by a laser, become comparable to or greater than the spontaneous emission and collision rates connecting these levels. This results in the excited state population N(u) acquiring a value of similar magnitude to that of the ground state, N(e). Under these conditions the observed fluorescence signal, which is proportional to N(u), is no longer linearly dependent on laser intensity I, but increases at a slower rate, and in principle ultimately becomes independent of I. A conceptual picture of optical saturation using a two-level picture is described. This is, however, inadequate for the description of a real experiment involving a molecule, such as OH, for several reasons, which will be explained briefly; these are the multi-level nature of the electronic states and energy transfer among them and effects due to spatial, spectral, and temporal fluctuations in the laser pulse.

Source record↗

Detailed Performance Calculations: Goddard Group, Appendix D

Two systems were described. The first used polarization to reduce scattered solar flux, the principal source of noise. The second used a narrowband detector and a different excitation wavelength. The results, which consider these systems, were presented emphasizing anticipated technology improvements because the analysis for each system required estimates of critical parameter even though each system would use existing technology. For the first, the information about the degree of polarization of the scattered solar flux was not measured but was estimated as 60 percent for viewing straight up with a solar zenith angle of 75 percent at sea level. The expected performance of this system therefore depends on the reliability of this estimate. For the second system, two estimates were required. First, the expected throughput of a Fabry-Perot interferometer operating at 309 nm, based on the performance exhibited by similar instruments working at other wavelengths, was estimated to be 3 percent. Second, the fluorescence efficiency of the proposed OH lines was estimated as 0.00004, since these quantities were not measured to date.

Source record↗

Detailed Performance Calculations: Portland State Group, Appendix F

For the Portland State University FAGE instrument, laser induced OH is calculated from (OH) laser = Cl(03)amb(H2O)amb. The dominant noise sources are the photon-counting fluctuations associated with the OH signal and the fluorescence background as well as concentration fluctuations in OH and in the species causing the background. Baric filtering and temporal filtering suppress the background by factors of 10 each.

Source record↗

Detailed Performance Calculations: Harvard Group, Appendix G

The measurement of OH density in the troposphere has many elements in common with the system that is currently used for in situ measurements of OH in the stratosphere. Techniques proposed by Harvard University and Washington State University are described.

Source record↗

Data appendix: F-number=1.0 EMR with a flexible back electrode

A 12.5 micron Tedlar low f-number electrostatic membrane reflector was tested. The antenna reflector was designed to achieve a spherical reflector surface with a focal length to diameter ratio f(sub n) of one and a potential accuracy of 1.0 over its 4.88 m diameter. The configuration required the cutting and joining of twelve pie-shaped panels to form the reflector surface. Electrostatic forces are used to tension this preformed membrane reflector. The test data is spare-only three sets of measurements were taken due to lack of funds.

Mihora, D. J.↗

Improved Orbiter Waste Collection System Study, Appendix D

Basic requirements for a space shuttle orbiter waste collection system are established. They are intended to be an aid in the development and procurement of a representative flight test article. Orbiter interface requirements, performance requirements, flight crew operational requirements, flight environmental requirements, and ground operational and environmental requirements are considered.

Source record↗

Commerce Lab: Mission analysis payload integration study. Appendix A: Data bases

The development of Commerce Lab is detailed. Its objectives are to support the space program in these areas: (1) the expedition of space commercialization; (2) the advancement of microgravity science and applications; and (3) as a precursor to future missions in the space program. Ways and means of involving private industry and academia in this commercialization is outlined.

Source record↗

A data base and analysis program for shuttle main engine dynamic pressure measurements. Appendix B: Data base plots for SSME tests 901-290 through 901-414

A dynamic pressure data base and data base management system developed to characterize the Space Shuttle Main Engine (SSME) dynamic pressure environment is described. The data base represents dynamic pressure measurements obtained during single engine hot firing tesets of the SSME. Software is provided to permit statistical evaluation of selected measurements under specified operating conditions. An interpolation scheme is also included to estimate spectral trends with SSME power level. Flow dynamic environments in high performance rocket engines are discussed.

Coffin, T.↗

A data base and analysis program for shuttle main engine dynamic pressure measurements. Appendix C: Data base plots for SSME tests 902-214 through 902-314

A dynamic pressure data base and data base management system developed to characterize the Space Shuttle Main Engine (SSME) dynamic pressure environment is reported. The data base represents dynamic pressure measurements obtained during single engine hot firing tests of the SSME. Software is provided to permit statistical evaluation of selected measurements under specified operating conditions. An interpolation scheme is included to estimate spectral trends with SSME power level. Flow Dynamic Environments in High Performance Rocket Engines are described.

Coffin, T.↗

A data base and analysis program for shuttle main engine dynamic pressure measurements. Appendix F: Data base plots for SSME tests 750-120 through 750-200

A dynamic pressure data base and data base management system developed to characterize the Space Shuttle Main Engine (SSME) dynamic pressure environment is presented. The data base represents dynamic pressure measurements obtained during single engine hot firing tests of the SSME. Software is provided to permit statistical evaluation of selected measurements under specified operating conditions. An interpolation scheme is also included to estimate spectral trends with SSME power level.

Coffin, T.↗