Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ambiguities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

On the flow-stress model of Preston, Tonks, and Wallace - Observations, parameter constraints, and implementations (Rev. 1)

A detailed discussion about the PTW flow-stress model has been presented, including theoretical considerations, model calibrations to experimental data, and model implementations in LANL ASC hydro-codes. The main findings are: In order to reproduce the intended behavior of the PTW model at high strain rates, the following conditions on the model parameters need to be valid: y 1 ≥ s 0 and y 2 ≥ β ; When the conditions above are not satisfied, PTW and PTW_Mod1 have slightly different behavior in the phonon-drag regime, and should be treated as different models. PTW exhibits a discontinuity above the critical strain rate. PTW_Mod1 does not show such a discontinuity but implies a different strain-rate dependence at high strain rates. Examples of this behavior include older calibrations for stainless steel and depleted uranium; In the thermal-activation regime, some flexibility was introduced in the original PTW model to allow for different rate-dependent behaviors at intermediate strain rates. Example: copper. However, many material calibrations do not require this extra flexibility, and the complexity and ambiguity of the intended behavior can be partially blamed for the inconsistent model implementations across ASC codes; The limit for the material constant p going to zero is well defined and leads to a simplified flow-stress equation, discontinuity free; Modern calibrations of the PTW parameters are done using Impala. Constraints on the PTW parameters are enforced; Implementation of the PTW model in LANL ASC hydro-codes suffered of several shortcom ings. At the time of writing, FLAG and xRAGE contain consistent and correct implemen tations of the PTW and PTW_Mod1 models. Corresponding changes to Pagosa have been suggested.

36 MATERIALS SCIENCE↗

Integration of Hybrids into Wholesale Power Markets

With growing commercial activity around utility-scale hybrid storage projects in the Unites States, independent system operators (ISOs) and regional transmission organizations (RTOs) are faced with making decisions on how to represent such emerging technology resources in the market clearing software through the definition of hybrid resource participation models. System operators are facing increasing uncertainties around efficient and reliable ways to operate these resources given the ambiguity around their impacts, particularly when high levels of hybrid resources are present. This study aimed to evaluate and compare the performance implications of different hybrid resource participation models in a realistic wholesale electricity market setting with significant deployment of hybrid resources, and to provide the industry with metrics that quantify the advantages and disadvantages of different participation options using realistic electricity market simulations. The different participation models are compared in terms of the impact to reliability of the overall system, the ability of the market to access the full capabilities of hybrid resources as measured by the economic efficiency, and asset profitability.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

ENDF-6 Formats Manual - Data Formats and Procedures for the Evaluated Nuclear Data Files ENDF/B-VI, ENDF/B-VII and ENDF/B-VIII

This revision of “ENDF-6 Formats Manual” pertains to version 6 of the ENDF formats. The seventh and eighth versions of the ENDF/B library, namely ENDF/B-VII and ENDF/B VIII, use the ENDF-6 format. The manual is based on the previous version of the document, revised in June 2005, In some cases the older version from October 1991 was consulted in order to resolve some ambiguities and errors that were introduced when the reference document was translated from WordPerfect in Word format.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report (DOE 2023) provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

42 ENGINEERING↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling Gray Zone Tactics Used Against Green Energy Supply Chains

This report documents a project demonstrating capabilities within Lawrence Livermore National Laboratory’s Cyber and Infrastructure Resilience program to place newly developed numeric simulations into the current, larger geopolitical context. The emergence of state-backed gray zone threats introduces an unprecedented challenge because they fall short of armed conflict and involve ambiguous tactics, requiring a fresh analytical approach to understanding their potential impact and countering them. In the context of our project, we analyze how China might use gray zone tactics to degrade the power of the United States, including our influence over global efforts to combat climate change.

25 ENERGY STORAGE↗

The Scientific Case for Concurrent Neutron and X-ray Scattering and Spectroscopy

The interrogation of materials with X-rays or neutrons to determine the structure, energetics, and dynamics of materials is fundamental to advancing materials' physical and chemical science and developing innovative material technologies. A transcending challenge in developing novel materials is that progress hinges on understanding the structure and dynamics across multiple time and length scales in complex materials that feature multiple components, interfaces, and compositions. Despite the ever-growing demands on materials’ characterization, existing approaches are almost exclusively based on isolated X-ray or neutron scattering, i.e., an approach commensurate with the more narrowly defined needs of fifty years ago. A three-day workshop sponsored by the U.S. National Science Foundation (NSF) analyzed the demand for concurrent neutron and X-ray (NeX) experiments. It was held at the Spring Hill Suites, San Jose, California, from June 2 to 4, 2022. In this workshop, 70 national and international experts ascertained the crucial need to establish NeX capabilities to advance the science of complex materials and systems in the US. Here, we illustrate the need for NeX scattering and spectroscopy experiments by showcasing examples that span areas as diverse as biomaterials, energy science, soft matter, and nanomaterials. To provide NeX capability will require new instrumentation that enables concurrent experiments. Affected areas include chemistry, soft matter, quantum materials, pure and applied chemistry, bioscience, geoscience, and applied materials. NeX benefits research outcomes due to the complementarity of the two techniques, which is essential for better model refinement. While joint refinement of data from separate neutron and X-ray experiments is critical to avoid ambiguities, especially in multiphase-multicomponent materials, concurrent experiments overcome scientific and technical barriers associated with single measurements, separated by location and, thus, time. Among all the examples, these factors introduce uncertainties in the results that complicate data analysis. [1,2] [3] While models are strongly sample-dependent, the principles of joint refinement are generally applicable to these disciplines, including the development of advanced parameterization, modeling, and analysis techniques that also consider the temporal and spatial resolutions of the two methods, leading to unambiguous data interpretation. Solutions for technical barriers must be found to realize NeX experiments, including developing robust sample environments that meet the optical requirements of neutrons and X-rays.

36 MATERIALS SCIENCE↗

Context-Aware Learning for Inverse Design in Photovoltaics

This document describes progress in the ARPA-E DIFFERENTIATE project titled “Context-Aware Learning for Inverse Design in Photovoltaics” during the period of May 2019 to May 2022. This project is being performed at Iowa State University, New York University, Stanford University, and National Renewable Energy Laboratory. The project aims to develop a new machine learning (ML) framework to significantly accelerate the design of organic microstructures for improved organic photovoltaic performance. In this project, we had developed an inverse design framework using Deep Learning called InvNets for generating microstructures with desired physics-driven properties. As a preliminary product, in Milestone 3, we demonstrated how InvNets show 20% improvement in the performance of the microstructures and over 100X speedup in the performance compared to traditional processes for physics-driven inverse design. Later, in Milestone 6, we demonstrated that InvNets work for more complex physics properties, specifically, generating microstructures for organic photovoltaic cells with desired current-voltage characteristics. Further, in Milestone 4, we explored the idea of using physics-aware surrogates for obtaining solutions of partial differential equations(PDE) called as DiffNets(now called as NeuFENets to avoid ambiguity of names). The connection between both frameworks is that DiffNet surrogates form the physics-aware surrogate in the InvNet framework. Finally in Milestone 8, we extend our framework for other physics domains. Specifically, we explore building geometry-aware NeuFENets by developing physics surrogates that exploit ideas from traditional immersed boundary finite element methods. With these updates, we are able to achieve all the Milestones.

36 MATERIALS SCIENCE↗

Dual-Image Color Normalization to Enable High-Performance Concentrating Solar Optical Metrology

Concentrating Solar Power (CSP) requires precision mirrors, and these in turn require metrology systems to measure their optical slope. In this project we studied a color-based approach to the correspondence problem, which is the association of points on an optical target with their corresponding points seen in a reflection. This is a core problem in deflectometry-based metrology, and a color solution would enable important new capabilities. We modeled color as a vector in the [R,G,B] space measured by a digital camera, and explored a dual-image approach to compensate for inevitable changes in illumination color. Through a series of experiments including color target design and dual-image setups both indoors and outdoors, we collected reference/measurement image pairs for a variety of configurations and light conditions. We then analyzed the resulting image pairs by selecting example [R,G,B] pixels in the reference image, and seeking matching [R,G,B] pixels in the measurement image. Modulating a tolerance threshold enabled us to assess both match reliability and match ambiguity, and for some configurations, orthorectification enabled us to assess match accuracy. Using direct-direct imaging, we demonstrated color correspondence achieving average match accuracy values of 0.004 h, where h is the height of the color pattern. We found that wide-area two-dimensional and linear one-dimensional color targets outperformed hybrid linear/lateral gradient targets in the cases studied. Introducing a mirror degraded performance under our current techniques, and we did not have time to evaluate whether matches could be reliably achieved despite varying light conditions. Nonetheless, our results thus far are promising.

14 SOLAR ENERGY↗

Organoboron Based Antioxidants

Earth’s environment can be considered especially harsh due to the cyclic exposure of heat, moisture, oxygen, and ultraviolet (UV) and visible light. Polymer-derived materials subjected to these conditions over time often exhibit symptoms of degradation and deterioration, ultimately leading to accelerated material failure. To combat this, chemical additives known as antioxidants are often used to delay the onset of weathering and oxidative degradation. Phenol-derived antioxidants have been used for decades due to their excellent performance and stability; unfortunately, concerns regarding their toxicity and leaching susceptibility have driven researchers to identify novel solutions to replace phenolic antioxidants. Herein, we report on the antioxidant efficacy of organoborons, which have been known to exhibit antioxidant activity in plants and animals. Four different organoboron molecules were formulated into epoxy materials at various concentrations and subsequently cured into thermoset composites. Their antioxidant performance was subsequently analyzed via thermal, colorimetric, and spectroscopic techniques. Generally, thermal degradation and oxidation studies proved inconclusive and ambiguous. However, aging studies performed under thermal and UV-intensive conditions showed moderate to extreme color changes, suggesting poor antioxidant performance of all organoboron additives. Infrared spectroscopic analysis of the UV aged samples showed evidence of severe material oxidation, while the thermally aged samples showed only slight material oxidation. Solvent extraction experiments showed that even moderately high organoboron concentrations show negligible leaching susceptibility, confirming previously reported results. This finding may have benefits in applications where additive leaching may cause degradation to sensitive materials, such as microelectronics and other materials science related areas.

36 MATERIALS SCIENCE↗

Acoustic-based monitoring and machine learning of component status for microreactor applications

This report provides a description and assessment of recent efforts to couple acoustic-based experimental measurements and characterization with machine learning models in order to enhance structural health monitoring capabilities for nuclear microreactors. With resilient embedded sensors in development by others supported by programs funded by the US Department of Energy’s Office of Nuclear Energy, the work described herein builds upon ongoing efforts to improve non-destructive testing technology that relates measured acoustic signatures to component stresses and/or structural defects, using a combination of new experimental measurements and machine learning architectures. The experimental procedure remained similar to that developed for the previous year’s demonstration of damage detection by the authors, with the same damaged sample tested under similar applied stress conditions. Notably, a new mounting fixture was designed and implemented to improve measurement consistency and a more sophisticated laser Doppler vibrometer was employed to make high-fidelity vibration measurements. Two nominally identical sets of training data were collected for each experimental setup to better understand the repeatability of the experiment and to better test the generality of trained neural network models. Additionally, we obtained new high-quality 3D mode shapes of the damaged test article at various stress and excitation levels, providing greater insights into the physical response of the sample during testing. Previously, we demonstrated that a machine learning model based on a convolutional neural network can predict structural details of an artificially introduced interface (intact, rough cut, smooth cut), and the applied torque level. In this study, we have transitioned to graph-based neural network architectures to better develop and test a flexible framework that is more suitable to being transferred away from controlled benchtop experiments and into more applied settings where less-structured data inputs may be expected. In general, performance testing of a graph neural network on frequency-domain representations of the data indicates strong and consistent identification of test conditions for datasets recorded on damaged components. With goals of predicting damage location and other changing experimental conditions using limited datasets, predictive models using a graph neural network architecture correctly predicted the applied torque level with an accuracy of 85% using only a single measurement point and predicted within one torque level in 95% of test windows. Predictions of damage location had limited success due to the symmetry and minimal number of the damage scenarios presented during model training. Results were ambiguous as to whether the model could detect the location of the artificial damage, or if it was instead learning the location of a given measurement point on the part and subsequently detecting which points were closest to the location of the damage. This finding will be factored into upcoming planned work on damaged graphite components, where new experimental tests with a larger number and variety of damage scenarios are expected to provide improved validation of recent developments in monitoring methodology.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Radiometric Testing of Germicidal UV Products, Round 2: Upper-Room Luminaires (CALiPER Report)

This report analyzes the independently tested performance of eight germicidal ultraviolet (GUV) upper-room luminaires marketed for use in occupied spaces and purchased between March and June 2023. This type of product is mounted to upper walls or ceilings to treat air in the portion of the room above occupants; this allows for safe use of the room when the device is operating, but requires sufficient air mixing between upper and lower portions of the room. Three of the luminaires used UV-emitting LEDs, and the remaining five luminaires used low-pressure mercury (LPM) lamps. Product testing covered radiometric and electrical performance for each luminaire. Initial performance was measured for all eight products, and four were additionally measured after 100 h and 500 h of operation. Measured performance data allowed for comparison against manufacturer or vendor claims if the tested products included such claims. Some products had no performance data available for a given quantity (e.g., UV-C output power), and only four of the eight luminaires had radiant intensity distribution data files in a standard format (e.g., IES LM-63) available for download from product websites. The lack of publicly available performance data makes it difficult for potential buyers and specifiers to identify suitable products and design GUV systems for their specific applications. When products had performance claims, they were sometimes contradictory (e.g., unexplained differences between multiple power values) or ambiguous (e.g., measurement units conflict with quantity, unclear whether luminaire power or lamp power, unclear whether UV output power or UV-C output power). Three of the eight tested luminaires had claimed output power (i.e., radiant flux) values that exceeded measured values by more than an order of magnitude. There was substantial variation in UV-C radiant efficiency, with a measured range of 0.3–1.9% for LED and 0.4–2.1% for LPM, as shown in Figure 1. For example, the LPM luminaire with 0.4% radiant efficiency would need 5 times the amount of electrical energy used by the LPM luminaire with 2.1% radiant efficiency to produce the same amount of UV-C output power. LPM luminaires that had parabolic reflectors aligned with inclined louvers exhibited substantially higher UV-C radiant efficiency than tested luminaires with other designs, potentially cutting energy use by 75%. These results indicate a substantial opportunity for more energy efficient LPM luminaire designs, while demonstrating that UV LED luminaires can offer comparable UV-C radiant efficiency in this application. This may seem surprising, given that LED emitters have lower UV-C radiant efficiency than LPM lamps, but the efficiency-throttling louvers that are generally required for LPM luminaires typically are not needed for LEDs thanks to their directionality. However, lateral beam angles (which describe beam width as viewed from above) were 41–83° for LED luminaires versus 89–110° for LPM luminaires. More luminaires may be required if their lateral beam angles are relatively small, and coverage may be poor if UV-C radiant intensity distribution (i.e., beam shape) is not considered when designing systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Virtual Reality for Shoot/No-Shoot Decision Training in Law Enforcement: A Literature Review and Research Agenda

Virtual reality (VR) can materially improve “shoot / no-shoot” (SNS) training by giving officers realistic, repeatable practice making high-stakes decisions under pressure. Traditional tools—live-fire ranges and video simulators—build basics, but they cannot adapt to each officer in real time or fully mirror the complexity of the field. VR closes that gap by creating immersive scenarios that are safer, more flexible, easier to scale across units, and able to capture objective performance data. SNS decisions are not just about marksmanship; they rely on perception, judgment, memory, and the ability to hold fire when a threat is uncertain. Effective training therefore needs realism, decision complexity, and branching outcomes that reflect the true consequences of choices. These elements strengthen recognition of hostile intent while reducing false positives and building the self-control required in ambiguous situations. VR brings specific advantages: dynamic environments, full-body interaction, and the ability to measure performance with precision—enabling targeted feedback and better transfer of learning to the street. At the same time, responsible deployment must address scenario quality (credible environments and behaviors), lawful decision models, and user wellbeing (appropriate stress levels, comfort, and safety). Sandia’s VIPER Lab is positioned to lead this work. The team combines human-performance science, AI/ML, and VR/AR development with a deep equipment bench (e.g., omnidirectional treadmill, eye-tracking, haptics, multiple HMDs). This ecosystem supports building and validating next-generation SNS training that is immersive, measurable, and trustworthy. Bottom line: Investment in VR-enabled SNS training that blends evidence-based design with careful validation and legal safeguards is expected to pay off in safer, more consistent decision-making and improved community trust, delivered through training that is practical to deploy at scale.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Optimizing Geospatial Assessments for Nuclear Safeguards Applications with Large Language Models

A multidisciplinary team at Argonne National Laboratory evaluated the ability of large language models (LLMs) to identify geographic locations from open-source text and assessed post-processing measures to strengthen the reliability of those extractions in support of international nuclear safeguards. The study focused on addressing challenges such as toponym ambiguity, imprecise descriptions, and misinformation, which often undermine the accuracy of LLM-derived geospatial assessments. By integrating authoritative geospatial datasets, employing rigorous validation techniques, and leveraging human-in-the-loop processes, the project aimed to enhance the precision, transparency, and reproducibility of geospatial localization workflows. The findings demonstrate that while LLMs exhibit significant potential for accelerating geospatial analysis, their outputs require systematic grounding and verification to ensure reliability in high-stakes applications. This work contributes to the broader field of geospatial intelligence and supports strategic objectives of international organizations such as the International Atomic Energy Agency (IAEA) and the U.S. Department of Energy (DOE).

97 MATHEMATICS AND COMPUTING↗

Morphology-Based Building Use-Type Modeling: Learnability-First Schema Discovery

This technical memorandum documents an update to the building use-type classification workflow, used in LandScan Mosaic, that replaces a fixed, semantically defined class schema with a learnability-first schema discovery procedure. Historically, the target label schema was specified a priori (e.g., predicting a chosen set of use-type codes), and model training and evaluation were performed within that fixed label space. In the updated workflow, the pipeline first evaluates which non-residential distinctions are learnable under spatial generalization and then collapses ambiguous classes into data-driven groupings before finalizing the schema used for production training.

97 MATHEMATICS AND COMPUTING↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Technical Note: SABRS-3 ZEP D3 Periodicities

This technical note documents an investigation of periodic structure in SABRS ZEP D3 detector data spanning February 2022 through April 2026. The analysis was motivated by reports from the co-located NRL SIRI-2 instrument of a 5-minute periodicity beginning in 2026. This report presents null results for the 5-minute search and documents an ambiguous 18.6-hour spectral feature for future reference.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗