Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ambient temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Multi-mechanistic Strategies for Novel Solid Electrolytes with Superior Properties

Despite a wide range of solid electrolyte phases, most of them only exist at high temperatures. The challenge is to tailor the chemical compositions of solid electrolyte materials that yield high ionic conductivities and low activation energies at ambient temperature. This is crucial for the development of all-solid-state batteries that are both powerful and safe. Here, we report our recent works to meet this challenge by utilizing multiple mechanistic principles and clusters as the building blocks. We show that the atomic-level interactions that govern the fast-ion conduction can be optimized by incorporating polyanion dynamics, non-stoichiometry, point defects and strong ionic correlations. Specifically, two case studies of Li/Na solid electrolytes will be covered, including lithium solid electrolytes (SE) with record-high ionic conductivities at room temperature (over 100 mS/cm) and sodium SE with record-low activation energies (< 0.1 eV).

Fang, Hong↗

Data book for 12.5-inch diameter SRB thermal model water flotation test - 14.7 psia, series P024

Tests were conducted to determine how thermal conditions affect space shuttle solid rocket booster (SRB) flotation. Acceleration, pressure, and temperature data were recorded from initial water impact to final flotation position using a 12.5-inch diameter thermal model of the SRB at ambient pressure. The model was 136.9 inches long and weighed 117.3 lbm. The tests indicated the following differences from ambient temperature tests: (1) significant negative static pressures can occur during penetration; (2) maximum penetration is increased; and (3) final flotation is in the spar buoy mode.

Allums, S. L.↗

Thermal Exposure Effects on Properties of Al-Li Alloy Plate Products

Aluminum-Lithium (AL-Li) alloys offer significant performance benefits for aerospace structural applications due to their higher specific properties compared with conventional aluminum alloys. For example, the application of an Al-Li alloy to the space shuttle external cryogenic fuel tank contributed to the weight savings that enabled successful deployment of International Space Station components. The composition and heat treatment of this alloy were optimized specifically for strength-toughness considerations for an expendable cryogenic tank. Time dependent properties related to reliability, such as thermal stability, fatigue, and corrosion, will be of significant interest when materials are evaluated for a reusable cryotank structure. As most aerospace structural hardware is weight sensitive, a reusable cryotank will be designed to the limits of the materials mechanical properties. Therefore, this effort was designed to establish the effects of thermal exposure on the mechanical properties and microstructure of one relatively production mature alloy and two developmental alloys C458 and L277. Tensile and fracture toughness behavior was evaluated after exposure to temperatures as high as 3oooF for up to IO00 hrs. Microstructural changes were also evaluated to correlate with the observed data trends. The ambient temperature parent metal data showed an increase in strength and reduction in elongation after exposure at lower temperatures. Strength reached a peak with intermediate temperature exposure followed by a decrease at highest exposure temperature. Characterizing the effect of thermal exposure on the properties of Al-Li alloys is important to defining a service limiting temperature, exposure time, and end-of-life properties.

Shah, Sandeep↗

A Sustainable Multi-Dimensional Printable Material

Polymeric materials are usually tailored for specific functionality. A single polymer exhibiting multiple simultaneous functionalities often requires intricate molecular architecture, which is difficult to manufacture at scale because of its complex synthesis routes. In this work, a facile, partly renewable composition—prepared via reactive melt processing—that induces tunable functionalities such as 3D printability, shape recovery, and self-healing while exhibiting satisfactory mechanical properties is reported. The system with a hydrogen-bonded 3D network consists of thermally reversible nano-scale agglomerates of sustainable, rigid phenolic oligomers and crystallizable flexible polymer. Local molecular mobility and temperature-dependent relaxation and recovery of the non-equilibrium networked states enable exploiting these simultaneous functionalities. Transitions involving solidification and structure stabilization at ambient temperature spanning several hours after preheating only at 70 °C directly contrast typical thermoplastic or thermoplastic elastomer behaviors. Results from this study can inform the design of future rheology modifiers and materials for soft robotics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and performance validation of a high-temperature downhole permanent magnet generator used for an electro-pulse boring system in geothermal energy applications

Novel, direct-energy drilling technologies such as electro-pulse boring, have the potential to significantly increase the speed and depth of geothermal drilling but have not achieved widespread adoption due to several economic and technical barriers. One major challenge is that these drilling systems require electric power downhole. The current practice is to supply power to the drill string components by running electric cables down the geothermal well, but at the targeted well depths, this practice is cost-inhibitive, inefficient in terms of power consumption, and adds an additional failure point with the long cabling going through a highly corrosive, high-temperature environment. A solution to this problem is to develop high-temperature electric generator technology that can generate the required power downhole. Such a generator must also operate with high efficiency at the target downhole ambient temperature of 250 °C. In this paper, we investigate the various design considerations for this concept and subsequently design the downhole electric generator using a multi-objective design optimization approach. Through electromagnetic-, thermal- and short-circuit fault condition analysis, it is demonstrated that the optimized downhole electric generator concept presented in this paper can meet the performance requirements within this extreme drilling environment. Most remarkably, it is shown that a generator efficiency of 90% is achieved. In conclusion, to validate the results presented in this paper, a prototype generator is built and its performance is measured at 250 °C using a test bench uniquely developed for this application.

15 GEOTHERMAL ENERGY↗

Necromass responses to warming: A faster microbial turnover in favor of soil carbon stabilisation

Microbial byproducts and residues (hereafter ‘necromass’) potentially play the most critical role in soil organic carbon (SOC) sequestration. However, little is known about the influence of climate warming on necromass accumulation in the agroecosystem and the underlying mechanisms associated with microbial life strategies. Here, in order to address these knowledge gaps, we used amino sugars as biomarkers of microbial necromass, and investigated their variation through an 8-year trial in an agroecosystem with two warming levels (+1.6 and + 3.2 °C) compared to ambient temperature. The results showed that the lower warming level had no impact on total microbial necromass carbon. Conversely, warming the soil 3.2 °C above ambient increased total microbial necromass by 17 % and its contribution to SOC by 21.3 %, mainly by increasing fungal necromass (+19.8 %), whereas +3.2 °C warming had no impact on bacterial necromass. At the phylum level, compared with the ambient control, +3.2 °C warming induced an increase in the abundance of Proteobacteria and a decrease in both Acidobacteria and Actinobacteria, whereas in the fungal community, Ascomycota increased and Mortierellomycota decreased. This indicates that r-strategists outcompete K-strategists in warmer climates, which led to increased microbial necromass production and accumulation, as supported by the positive correlation between r-strategists and microbial necromass. Stronger microbial competition for resources also resulted in a higher biomass turnover rate, greater cell death, and greater production of microbial necromass. This was supported by the lower bacterial and fungal network complexity and trophic links under warming conditions. In addition, the necromass generated from accelerated microbial turnover further offsets warming-induced deceases in microbial biomass. Consequently, bulk SOC did not change, despite microbial necromass having a much greater response to warming than the soil C pool. Therefore, future climate warming may influence the composition and persistence of SOC during microbial degradation.

54 ENVIRONMENTAL SCIENCES↗

Assessment of Blocking Contacts in Suppressing Polarization Effects in CsPbBr 3 Perovskite Detectors

The CsPbBr 3 perovskite has garnered significant attention as a room-temperature semiconductor for hard radiation detection due to straightforward synthesis, scalable crystal growth, low cost, and excellent energy resolution. However, despite these advantages, at ambient temperature, CsPbBr 3 devices may experience performance deterioration and irreversible failure due to “polarization” induced by electromigration of ions to electrical connections on the device. In this study, we tested several contact materials and their optimization deposition techniques to assess the stability of high-performance CsPbBr 3 γ-ray detectors. Metals, with low work functions (Ti, In, Sn, Sb, Pb, Bi, Al, Au, and TiC) and high-work-function (Au or Pt) contacts, were used to form different Schottky junctions using vacuum thermal evaporation, electron-beam evaporation, and sputtering methods. These detectors were tested in intermittent and continuous modes to assess their stability. Among the tested detectors, the Bi/CLB/Pt electrode configuration demonstrated superior stability, operating effectively for 11 months under periodic testing and 16 days under continuous testing. In contrast, other configurations functioned only for a few months under intermittent conditions. Upon incorporating a ~40-nm-thick TiC passivation layer on the anode side (Bi/TiC/CLB/Pt), the CLB device operated continuously for 36 days without degradation. In many cases, the failure mode of the devices was due to the degradation of the anode. Here, the chemical changes in the fresh and deteriorated anodes were characterized using scanning electron microscopy and energydispersive X-ray spectroscopy

CsPbBr3 perovskite↗

Equations for the determination of humidity from dewpoint and psychrometric data

A general expression based on the Claperon-Clausius differential equation that relates saturation vapor pressure, absolute temperature, and the latent heat of transformation was derived that expresses saturation vapor pressure as a function of absolute temperature. This expression was then used to derive general expressions for vapor pressure, absolute humidity, and relative humidity as functions of either dewpoint and ambient temperature or psychrometric parameters. Constants for all general expressions were then evaluated to give specific expressions in both the international system of units and U.S. customary units for temperatures above and below freezing.

Parish, O. O.↗

MARS 1414 recorder environmental tests

Environmental testing is described and the data of the Modular Airborne Recording System (MARS) 1414 is presented. The preliminary data marks a starting point for more complete thermal testing in the future. The unit was operated at +/-55 C at one atmosphere, -10 C at 75,000 feet (28 mm Hg)at the other. Temperatures at 13 locations on the unit were monitored and plotted against elapsed time. From the test results, some estimation can be made of ambient temperatures in which the heaters will operate and shut off. This data is sufficient to complete a preliminary analysis of the MARS 1414 Recorder, and to design further tests.

Langjahr, D.↗

Estimation of fan pressure ratio requirements and operating performance for the National Transonic Facility

The National Transonic Facility (NTF), a fan-driven, transonic, pressurized, cryogenic wind tunnel, will operate over the Mach number range of 0.10 to 1.20 with stagnation pressures varying from 1.00 to about 8.8 atm and stagnation temperatures varying from 77 to 340 K. The NTF is cooled to cryogenic temperatures by the injection of liquid nitrogen into the tunnel stream with gaseous nitrogen as the test gas. The NTF can also operate at ambient temperatures using a conventional chilled water heat exchanger with air on nitrogen as the test gas. The methods used in estimating the fan pressure ratio requirements are described. The estimated NTF operating envelopes at Mach numbers from 0.10 to 1.20 are presented.

Gloss, B. B.↗

Shunt Diode Designs in Li/cf Shuttle Batteries

Although Li/CF cells and batteries have an excellent safety record, they are included with other battery systems that require additional safety precautions. One precaution suggested is the inclusion of shunt diodes into these batteries. The benefits of this addition are examined. All cells tested at elevated temperatures vent regardless of length of time between being fully discharged and reversed or inclusion of the diode in the system. Cells discharged at ambient temperatures all show a relatively quick reversal, but stabilize at voltages that are high enough that the diodes are not functioning. Cells tested at depressed temperatures reverse the deepest of all cells tested, with the deepest reversal occurring very early in the test and voltages recovering to above -0.60 volts near the end of the tests. Anode limited cells will eliminate the venting during hot reversal.

Miller, D.↗

Thermocapillary flow and melt/solid interfaces in floating-zone crystal growth under microgravity

Computer simulation of steady-state axisymmetrical heat transfer and fluid flow was conducted to study thermocapillary flow and melt/solid interfaces in floating-zone crystal growth under microgravity. The effects of key variables on the extent of thermocapillary flow in the melt zone, the shapes of melt/solid interfaces and the length of the melt zone were discussed. These variables are: (1) the temperature coefficient of surface tension (or the Marangoni number), (2) the pulling speed (or the Peclet number), (3) the feed rod radius, (4) the ambient temperature distribution, (5) the heat transfer coefficient (or the Biot number), and (6) the thermal diffusivity of the material (or the Prandtl number).

Lan, C. W.↗

Nulling Infrared Radiometer for Measuring Temperature

A nulling, self-calibrating infrared radiometer is being developed for use in noncontact measurement of temperature in any of a variety of industrial and scientific applications. This instrument is expected to be especially well-suited to measurement of ambient or near-ambient temperature and, even more specifically, for measuring the surface temperature of a natural body of water. Although this radiometer would utilize the long-wavelength infrared (LWIR) portion of the spectrum (wavelengths of 8 to 12 ?m), its basic principle of operation could also be applied to other spectral bands (corresponding to other temperature ranges) in which the atmosphere is transparent and in which design requirements for sensitivity and temperature-measurement accuracy could be satisfied.

Ryan, Robert↗

Radiant Temperature Nulling Radiometer

A nulling, self-calibrating infrared radiometer is being developed for use in noncontact measurement of temperature in any of a variety of industrial and scientific applications. This instrument is expected to be especially well-suited to measurement of ambient or near-ambient temperature and, even more specifically, for measuring the surface temperature of a natural body of water. Although this radiometer would utilize the long-wavelength infrared (LWIR) portion of the spectrum (wavelengths of 8 to 12 m), its basic principle of operation could also be applied to other spectral bands (corresponding to other temperature ranges) in which the atmosphere is transparent and in which design requirements for sensitivity and temperature-measurement accuracy could be satisfied. The underlying principle of nulling and self-calibration is the same as that of a typical microwave radiometer, but because of differences between the characteristics of signals in the infrared and microwave spectral regions, the principle must be implemented in a different way. A detailed description of the instrument including an infrared photodetector equipped with focusing input optics [e.g., lens(es) and/or mirrors] and an input LWIR band-pass filter is presented.

Source record↗

Nulling Infrared Radiometer for Measuring Temperature

A nulling, self-calibrating infrared radiometer is being developed for use in noncontact measurement of temperature in any of a variety of industrial and scientific applications. This instrument is expected to be especially well-suited to measurement of ambient or near-ambient temperature and, even more specifically, for measuring the surface temperature of a natural body of water. Although this radiometer would utilize the long-wavelength infrared (LWIR) portion of the spectrum (wavelengths of 8 to 12 m), its basic principle of operation could also be applied to other spectral bands (corresponding to other temperature ranges) in which the atmosphere is transparent and in which design requirements for sensitivity and temperature-measurement accuracy could be satisfied.

Ryan, Robert↗

Nulling Infrared Radiometer for Measuring Temperature

A nulling, self-calibrating infrared radiometer is being developed for use in noncontact measurement of temperature in any of a variety of industrial and scientific applications. This instrument is expected to be especially well-suited to measurement of ambient or near-ambient temperature and, even more specifically, for measuring the surface temperature of a natural body of water. Although this radiometer would utilize the long-wavelength infrared (LWIR) portion of the spectrum (wavelengths of 8 to 12 m), its basic principle of operation could also be applied to other spectral bands (corresponding to other temperature ranges) in which the atmosphere is transparent and in which design requirements for sensitivity and temperature-measurement accuracy could be satisfied.

Ryan, Robert↗

Insulation Test Cryostat with Lift Mechanism

A multi-purpose, cylindrical thermal insulation test apparatus is used for testing insulation materials and systems of materials using a liquid boil-off calorimeter system for absolute measurement of the effective thermal conductivity (k-value) and heat flux of a specimen material at a fixed environmental condition (cold-side temperature, warm-side temperature, vacuum pressure level, and residual gas composition). The apparatus includes an inner vessel for receiving a liquid with a normal boiling point below ambient temperature, such as liquid nitrogen, enclosed within a vacuum chamber. A cold mass assembly, including the upper and lower guard chambers and a middle test vessel, is suspended from a lid of the vacuum canister. Each of the three chambers is filled and vented through a single feedthrough. All fluid and instrumentation feedthroughs are mounted and suspended from a top domed lid to allow easy removal of the cold mass. A lift mechanism allows manipulation of the cold mass assembly and insulation test article.

Fesmire, James E.↗

Development and Testing of Pulse Guns for Combustion Instability Testing

To test liquid rocket engines (LREs) for combustion instabilities, devices such as bombs are often used to create pressure wave disturbances. Bombs, while effective, are inherently dangerous, expensive, and difficult to procure. Over the years, pulse guns have been used as a safer and more cost-effective way to generate controlled pressure disturbances in engine chambers. In anticipation of the need for stability testing of prototype LREs at NASA Marshall Space Flight Center (MSFC), a set of pulse guns have been designed, fabricated, tested, and characterized. The pulse gun program is funded by the RS-25 Engine Program managed out of MSFC and funded by NASA’s Space Launch System (SLS) through the MSFC Liquid Engines Office (LEO). A pulse gun is a simple device – like a traditional gun, it has a breech and barrel section. However, unlike a traditional gun, there is no bullet, as the purpose of the pulse gun is strictly to fire a high pressure pulse. Instead of a firing pin and primer that would normally be used in a traditional gun, an initiator is used to activate the gun powder. The initiator is a highly reliable pyrotechnic initiator. For this study, clone versions of the NASA Standard Initiator (NSI) were used. The initiator is used to ignite a pre-measured amount of gun powder loaded into the breech. When the pressure of the burnt gun powder exceeds the set point of a downstream burst disk, the disk ruptures, allowing the high pressure pulse to travel downstream through the barrel section. A ballistic pressure transducer located in the breech section is used to measure the short duration, high pressure pulse. Some configurations of the pulse gun have barrel sections that include one or more additional ballistic pressure transducers. These additional pressure measurements help track the degradation and damping of the pulse as it travels out of the barrel section. The measurements may also be used to determine the velocity of pulse. The objective of this paper is to present the different variants of this newly-developed pulse gun and characterize performance over a range of parameters. The parameters include breech diameter, barrel length, amount of gun powder used, the way the gun powder is packed, and the pressure setting of the burst disk. There are a total of six pulse guns: three with the 0.25 inch breech and three different length barrels, and three with the 0.40 inch breech and three different length barrels. For both breech sizes, the associated barrels are referred to as standard, one-port, and two-port barrels. The standard barrel has no instrumentation and is likely the barrel that will be used for engine stability testing. The one- and two-port barrels were designed specifically for pulse gun component testing to allow measurements of the magnitude and timing of the high pressure pulse as it makes its way through the pulse gun. The burst disks tested were commercially-available burst disks designed to rupture at 8,000, 16,000, and 24,000 psid. Testing was accomplished by firing the pulse gun into a test chamber pressurized with nitrogen at about 2300 psig. A total of four Model 113B23 High frequency ICP® pressure sensors (10k psi) were mounted in the test chamber, in the same plane as the pulse gun. Two of the sensors had “trimmed” adapters, and two did not. Given the symmetrical configuration of the sensors within the test chamber, different amplitudes of pressure measurements are attributed to the use of trimmed versus untrimmed adapters. The untrimmed adapters, with their narrower passages, tended to amplify the pressure amplitudes by as much as 50%. In total, 41 pulse gun tests have been conducted.Data are still being analyzed, but some trends are apparent. For example, measurements taken within the pulse gun are shown in Figures 3 and 4 for Hot-fires (HFs) # 11 and 39, respectively. Both tests were identical in that the 0.40 inch ID breech, two-port barrel, 8,000 psid burst disk, and same amount of gunpowder (6.639 grains for HF# 11, and 6.576 grains for HF# 39) were used, and the back pressure in the nitrogen test chamber was ~2300 psig. Despite keeping all these variables constant, the results from these two tests look quite different. For both tests, the first pressure peak shown in the P2111 trace within the breech is the firing of the initiator. The second peak and any subsequent peaks are from the combustion of the gunpowder. It should be noted that because the sensors are dynamic, the ~2300 psig baseline static pressure is not shown in the figures. For HF# 11, the burst disk clearly ruptured in a little over 0.1 ms from the time the initiator was fired. This is evident from the abrupt rise in pressure for P2112 followed by another abrupt rise in pressure for P2113. The sensors track the movement of the high pressure pulse through the pulse gun. For HF# 39, however, there was nearly 1 ms delay between the initiator firing and the burst disk rupturing. The only difference between these two tests was the way in which the gunpowder was packed within the breech. For HF# 11, the gunpowder was poured directly into the breech, atop the initiator, and held in place with a vegetable fiber wad appropriately sized for the barrel diameter. Once in place, the wad firmly held the gunpowder in place. For HF# 39, the gunpowder was rolled within cigarette paper with the ends of the paper twisted. The rolled gunpowder was gently pushed down into the breech, toward the initiator, and no wad was used. This method of loading the gunpowder consistently produced longer delays in the rupture of the burst disk, presumably because there was a steady, fuller burning of the gunpowder. The burst disk was rated for 8,000 psid, which means that the burst disk should not have opened until the pressure in the breech reached ~10,300 since there was ~2300 psig back pressure in the test chamber. In the case of HF# 11, the breech pressure only reached roughly 4200 psi before there was leakage either through or past the burst disk, but for HF#39, the breech pressure reached 10,600 psi prior to the burst disk opening. The temperature of the burst disk is certainly a factor in determining when the burst disk will rupture. A sharp rise in the burst disk temperature could weaken it and cause it to stray from the designed set point burst pressure. The burst disks are manufactured of Inconel to try to reduce their sensitivity to temperature, but how the burst disks perform above 900°F is not documented. All burst disks were engineered and tested by the manufacturer for ambient temperature conditions. One theory for why rolling the gunpowder in cigarette paper may produce better results is related to a more controlled temperature environment. The cigarette paper may act as a sheath that protects the burst disk from excessive temperatures during the rapid buildup of pressure in the breech. The ultimate benefit of not breeching the burst disk prematurely is shown in Figures 5 and 6, which graphs the resultant pressure pulse produced in the test chamber. For HF #11, the peak pressure on the P2123 trimmed adapter is about 270 psi, while for HF# 39 it is 343 psi, which is about 1.27 times greater in magnitude. In either case, the pressure pulse is ~20 μs in width once it reaches the test chamber. Another pressure rise about 100 μs later can be seen on the sensors located across from the pulse gun port, P2124 and P2121. These pressures are lower due to attenuation of the pressure wave as it moves across the test chamber. After the wave encounters the wall, it reflects back and forth within the chamber until it completely dissipates.

Pulse Gun↗