Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “acceptance sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Statistical Framework for Planning a Shelf Life Program with Binary Performance Data

This document outlines a statistical framework for establishing a shelf-life program for components whose performance is measured by a binary response, usually ‘pass’ or ‘fail.’ The approach applies to both single measurement devices and repeated measurement devices. The high-level objective of these plans is to quickly detect any sizeable increase in fraction defective as the product ages. The statistical approach is to choose a sample size and monitoring technique that alarms when the fraction defective increases to an unacceptably high level, but does not alarm when the process is at nominal. The nominal (acceptable) fraction defective is used, and an increased fraction defective (unacceptable) is assumed as part of the control chart design. The control chart recommended for this problem is the Bernoulli Cumulative Sum (CUSUM) control chart.

97 MATHEMATICS AND COMPUTING↗

Verification study of thorium cross section in MVP calculation of thorium based fuel core using experimental data

Considering the importance of thorium data and concerning about the accuracy of Th-232 cross section library, a series of experiments of thorium critical core carried out at KUCA facility of Kyoto Univ. Research Reactor Inst. have been analyzed. The core was composed of pure thorium plates and 93% enriched uranium plates, solid polyethylene moderator with hydro to U-235 ratio of 140 and Th-232 to U-235 ratio of 15.2. Calculations of the effective multiplication factor, control rod worth, reactivity worth of Th plates have been conducted by MVP code using JENDL-4.0 library [1]. At the experiment site, after achieving the critical state with 51 fuel rods inserted inside the reactor, the measurements of the reactivity worth of control rod and thorium sample are carried out. By comparing with the experimental data, the calculation overestimates the effective multiplication factor about 0.90%. Reactivity worth of the control rods evaluation using MVP is acceptable with the maximum discrepancy about the statistical error of the measured data. The calculated results agree to the measurement ones within the difference range of 3.1% for the reactivity worth of one Th plate. From this investigation, further experiments and research on Th-232 cross section library need to be conducted to provide more reliable data for thorium based fuel core design and safety calculation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Micro arc oxidation of aluminum for nuclear applications

Dry cask storage and transport of used (spent) nuclear fuel rely upon the basket and shell of the cask to transfer the decay heat from the fuel assemblies. Cask licensees have considered the use of light metal (aluminum) oxidation to enhance the emissivity of aluminum alloy or aluminum based Metal Matrix Composites (MMC) used in the cask basket. However, traditional anodization techniques suffer from issues that make fabrication and regulatory acceptance problematic. The Micro Arc Oxidation (MAO) technology overcomes the problems associated with traditional anodization in the production of consistent, uniform and reliable high emissivity coatings of aluminum alloys. Samples of AA 2219 and an aluminum-based MMC were treated using a proprietary MAO process and subjected to a number of tests to confirm suitability of the coated material. The treated material was inspected using macro photography and Scanning Electron Microscopy (SEM). A consistent, uniform black, porous surface with a typical surface roughness of Ra = 7-8 μm was observed. Emissivity of treated surfaces with thicknesses ranging from 24 microns to 40 microns was measured using an integrating sphere. In all cases, the emissivity coefficient at room temperature in the ranges of 400 to 700 nanometers and 1000 to 1650 nanometers was above 0.8, reaching 0.94 depending on the thickness. The MAO process yield was tested by coating 400 spent fuel basket components to ensure a minimum specified thickness. 97% of the tested points met or exceeded the minimum thickness required. The defect density was very low and 100% of the components met the quality assurance criteria. In-service surface performance was tested by exposing the treated surface to a number of high temperature environments (air, vacuum, nitrogen) and thermal cycling in air. In all cases, the surface remained unchanged. Test samples were exposed to 90 Celsius degrees borated and demineralized water for 48 hours with no change to the sample treated surface. Finally, tests sample were exposed to 60 C. degrees borated water for 168 hours with no change to the sample treated surface. MAO technology appears to be a viable method to provide consistent, durable, and high emissivity coatings, that can be used in the fabrication and licensing of dry storage/transportation casks.

36 MATERIALS SCIENCE↗

Integrated Waste Feed Qualification Program for Direct LAW Feed to WTP - 16421

The Hanford Tank Waste Treatment and Immobilization Plant (WTP) is a one-of-a-kind facility being designed and constructed for DOE by Bechtel National, Inc. (BNI) and principal subcontractor URS, to process and vitrify radioactive waste stored in underground tanks at the Hanford Site. The Tank Operations Contractor (TOC), Washington River Protection Solutions (WRPS), has the responsibility to retrieve, stage, pretreat, and deliver feed directly to the WTP Low Activity Waste (LAW) Vitrification Facility. The Direct Feed LAW (DFLAW) scenario is being considered by DOE as a strategy to treat Hanford tank wastes as soon as practicable. Extensive planning is underway by One System, an effort with joint participation by WTP and TOC personnel. The initial focus of One System is to achieve the required integration to ensure the waste feed meets acceptance requirements for processing in the TOC Low Activity Waste Pretreatment System (LAWPS) and WTP LAW facilities. The integrated waste feed qualification program approach for DFLAW was defined by One System during a four-day workshop. The effort resulted in a feasible approach for integrating LAWPS and LAW feed acceptance requirements to vitrify low-activity waste while complying with facility design basis, safety basis, waste acceptance criteria, and glass product compliance. The defined qualification program will provide a systematic approach to test newly staged feed campaigns at bench-scale using actual tank waste samples. The required integration and basis for obtaining sufficient and necessary data to qualify the feed for DFLAW facilities are discussed in this paper. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SLUDGE BATCH 6/TANK 51 SIMULANT CHEMICAL PROCESS CELL SIMULATIONS

Qualification simulant testing was completed to determine appropriate processing conditions and assumptions for the Sludge Batch 6 (SB6) Shielded Cells demonstration of the DWPF flowsheet using the qualification sample from Tank 51 for SB6 after SRNL washing. It was found that an acid addition window of 105-139% of the DWPF acid equation (100-133% of the Koopman minimum acid equation) gave acceptable Sludge Receipt and Adjustment Tank (SRAT) and Slurry Mix Evaporator (SME) results for nitrite destruction and hydrogen generation. Hydrogen generation occurred continuously after acid addition in three of the four tests. The three runs at 117%, 133%, and 150% stoichiometry (Koopman) were all still producing around 0.1 lb hydrogen/hr at DWPF scale after 42 hours of boiling in the SRAT. The 150% acid run reached 110% of the DWPF SRAT limit of 0.65 lb H{sub 2}/hr, and the 133% acid run reached 75% of the DWPF SME limit of 0.223 lb H{sub 2}/hr. Conversely, nitrous oxide generation was subdued compared to previous sludge batches, staying below 25 lb/hr in all four tests or about a fourth as much as in comparable SB4 testing. Two other processing issues were noted. First, incomplete mercury suspension impacted mercury stripping from the SRAT slurry. This led to higher SRAT product mercury concentrations than targeted (>0.45 wt% in the total solids). Associated with this issue was a general difficulty in quantifying the mass of mercury in the SRAT vessel as a function of time, especially as acid stoichiometry increased. About ten times more mercury was found after drying the 150% acid SME product to powder than was indicated by the SME product sample results. Significantly more mercury was also found in the 133% acid SME product samples than was found during the SRAT cycle sampling. It appears that mercury is segregating from the bulk slurry in the SRAT vessel, as mercury amalgam deposits for example, and is not being resuspended by the agitators. The second processing issue was significant ammonium ion formation as the acid stoichiometry was increased due to the high noble metal-high mercury feed conditions. Ammonium ion was found partitioned between the SRAT product slurry and the condensate from the lab-scale off-gas chiller downstream of the SRAT condenser. The ammonium ion was produced from nitrate ion by formic acid. Formate losses increased with increasing acid stoichiometry reaching 40% at the highest stoichiometry tested. About a third of the formate loss at higher acid stoichiometries appeared to be due to ammonia formation. The full extent of ammonia formation was not determined in these tests, since uncondensed ammonia vapor was not quantified; but total formation was bounded by the combined loss of nitrite and nitrate. Nitrate losses during ammonia formation led to nitrite-to-nitrate conversion values that were negative in three of the four tests. The negative results were an artifact of the calculation that assumes negligible SRAT nitrate losses. The sample data after acid addition indicated that some of the initial nitrite was converted to nitrate, so the amount of nitrate destroyed included nitrite converted to nitrate plus some of the added nitrate from the sludge and nitric acid. It is recommended that DWPF investigate the impact of SME product ammonium salts on melter performance (hydrogen, redox). It was recommended that the SB6 Shielded Cells qualification run be performed at 115% acid stoichiometry and allow about 35 hours of boiling for mercury stripping at the equivalent of a 5,000 lb/hr boil-up rate.

08 HYDROGEN↗

Results For The Third Quarter Calendar Year 2016 Tank 50H Salt Solution Sample

In this memorandum, the chemical and radionuclide contaminant results from the Third Quarter Calendar Year 2016 (CY16) sample of Tank 50H salt solution are presented in tabulated form. The Third Quarter CY16 Tank 50H samples (a 200 mL sample obtained 6” below the surface (HTF-5-16-63) and a 1 L sample obtained 66” from the tank bottom (HTF-50-16-64)) were obtained on July 14, 2016 and received at Savannah River National Laboratory (SRNL) on the same day. Prior to obtaining the samples from Tank 50H, a single pump was run at least 4.4 hours, and the samples were pulled immediately after pump shut down. The information from this characterization will be used by Defense Waste Processing Facility (DWPF) & Saltstone Facility Engineering for the transfer of aqueous waste from Tank 50H to the Saltstone Production Facility, where the waste will be treated and disposed of in the Saltstone Disposal Facility. This memorandum compares results, where applicable, to Saltstone Waste Acceptance Criteria (WAC) limits and targets. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals will be documented at a later time per the Task Technical and Quality Assurance Plan (TTQAP) for the Tank 50H saltstone task. The chemical and radionuclide contaminant results from the characterization of the Third Quarter CY16 sampling of Tank 50H were requested by Savannah River Remediation (SRR) personnel and details of the testing are presented in the SRNL TTQAP.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improved Understanding of Zircaloy Hydrogen Pickup Mechanisms in BWRs. NSUF Report (Final Report)

Using an instrumented autoclave operating at 288°C and 1100 psi, electrical impedance spectroscopy (EIS) measurements were taken from three neutron irradiated fuel channel samples (Zircaloy-2 and Zircaloy-4). The three high priority fuel channel samples were tested at 288°C using a simulated PWR water with the AC frequency range extending down through 10 -4 Hz, with corresponding DC measurements to validate the resistance measurements. EIS measurements were also taken at room temperature using a simulated PWR water from four neutron irradiated fuel channel samples (Zircaloy-2 and Zircaloy-4). and four water rod samples (Zircaloy-2). EIS measurements were also performed on unirradiated Zircaloy-2 tubes that were previously oxidized in autoclaves at various temperatures for different time durations to obtain oxide layers of different thicknesses. These experiments proved to be more challenging than anticipated because of the small size of the samples, which required development of fixtures to allow valid testing of the materials, some of which are radioactive, under pressure and temperature. Equivalent circuits were used to model the data. Some samples resulted in Nyquist plots where the arcs were too close to each other resulting in the inability to separate the different oxide morphological thicknesses. Microstructural characterization in the form of optical microscopy, scanning electron microscopy and (scanning) transmission electron microscopy was performed to document the microstructural features of the oxidized Zr-2 and Zr-4 samples (oxide and metal/oxide interface) and to interpret the EIS results. At the start of this work, it was assumed that despite the laminar cracks and porosity visible in both optical and SEM, the oxide scale is dense near the metal, effectively preventing the water from contacting the metal directly. While it is generally accepted that the large laminar cracks pores allow the water to percolate into the oxide film, it is unknown just how deep it can go, and how interconnected is the porosity, which will dictate how much the porosity is connected electrically to the water within the oxide scale. The EIS results demonstrated that there is in fact a distribution of oxide thicknesses over the various samples, and within each material condition, that are communicating to the liquid. This is derived from the fact that Nyquist plots have an arc radius whose center point is often below the Z’ axis, implying that instead of a single oxide thickness, these oxides have a distribution of thicknesses. This distribution of thicknesses produces arcs that are not clearly separable in most of the samples.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

What causes the variation in superconducting properties of UTe 2 ?

Reaching a consensus on the superconducting order parameter of unconventional superconductors remains a central challenge in the field of magnetically-mediated superconductivity. Though UTe 2 is largely accepted as a rare example of an odd-parity superconductor, its precise order parameter remains highly debated, even at ambient conditions. A key underlying issue is the large sample-to-sample variation in superconducting properties at zero applied pressure and magnetic field. Here, we investigate the origin of the observed variation by means of single crystal x-ray diffraction (SC-XRD) and scanning transmission electron microscopy (STEM) measurements. Our results reveal highly ordered crystalline lattices, in agreement with the expected Immm structure, and no signs of uranium vacancies. Tiny amounts of interstitial defects, however, are observed on the Te2 layers that host Te chains along the b axis. We argue that these defects give rise to slightly enhanced atomic displacement parameters observed in SC-XRD data and are enough to disrupt the unconventional superconducting state in UTe 2 . Our findings highlight the need to focus future order parameter determination efforts on single crystals of UTe 2 with minimal amounts of structural disorder.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Poster - 56: Preliminary comparison of FF- and FFF-VMAT for prostate plans with higher rectal dose

Purpose: A recent retrospective study found 53 patients previously treated to 78Gy/39 using flattened filtered (FF) 6X-VMAT at GRRCC had rectal DVH more than one standard deviation higher than the average. This study was to investigate if using 6FFFor10FFF beams could reduce these DVHs without compromising target coverage. Methods: Twenty patients’ plans were re-planed with 2-arc 6X-VMAT, 6FFF-VMAT and 10FFF-VMAT using the Eclipse TPS following departmental protocol. All plans had the same optimization and normalization, and were evaluated against the acceptance criteria from the QUANTEC and Emami. Statistical differences in the mean dose to OARs (D{sub m}) and PTV homogeneity index (HI) between energies were tested using the paired sample Wilcoxon signed rank statistical method (p<0.05). Beam delivery accuracy was checked on five patients using portal dosimetry (PD). Results: The PTV HI for the 10FFF shows no statistical difference from the 6X. All the OARs, except left femoral head with 6FFF, have significantly lower Dm using 6FFF and 10FFF .There is no difference in the maximum doses to rectum and bladder and are limited by the prescribed doses. Measurements show good agreements in the gamma evaluation (3%/3mm) for all energies. Conclusion: This preliminary study shows that doses to the OARs are reduced using 10FFF for the same target coverage. The plans using 6FFF result in lower doses to some OARs, and statistically different PTV HI. All plans showed very good agreement with measurements.

60 APPLIED LIFE SCIENCES↗

Evaluation of an Engineered Form MOF CaSDB

Under the Off-Gas Sigma Team, Idaho National Laboratory (INL) and Pacific Northwest National Laboratoory (PNNL) have been able to study various sorbents for the separation of krypton (Kr) and xenon (Xe). PNNL has researched and prepared various metal-organic frameworks (MOFs) to use for the separation. Calcium–4,4’–sulfonyl dibenzoate (CaSDB), a high surface area MOF, was synthesized and sent to INL for deep bed testing. The MOF showed an acceptable saturation capacity, but a low breakthrough capacity; However, the recieved MOF was deemed as unusable in a flow system because of its powdery nature. In 2018, PNNL sent a sample of CaSDB – MOF powder to INL with the goal to incorporate it into an engineered form that maintained adsorption properties comparable to the original MOF. It was anticipated that the engineered form of the sorbent would possess sufficient mechanical strength to be used in a column, and eliminate the dustiness of the raw material to improve handling and operability. An engineered from of CaSDB – MOF (CaSDB – EF1) was produced by incorporating the raw powder into a polyacrylonitrile (PAN) binder. The PAN binding material eliminated the dustiness of the raw MOF and provided a robust matrix that prevents damage from handling and use in a column. Xe adsorption testing of the sorbent revealed that it performs as well or better than previous CaSDB samples tested at INL, with an initial breakthrough capacity of 14.4 mmol/ kg at ambient temperature. Reducing the operating temperature to 253 K resulted in an increased breakthrough capacity of Xe.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FRIT DEVELOPMENT FOR SLUDGE BATCH 6

The Savannah River National Laboratory (SRNL) evaluated a large number of Sludge Batch 6 (SB6) composition projections to support frit optimization for SB6 vitrification at the Defense Waste Processing Facility (DWPF). The evaluations discussed in this report occurred over a period of about 4 months, and included about 40 composition projections, developed by both Savannah River Remediation (SRR) and SRNL. Paper study assessments were used to evaluate the sludge composition projections with arrays of potential frit compositions using the predictive models in the DWPF Product Composition Control System (PCCS). Both nominal sludge compositions and sludge compositions with anticipated compositional variation were considered. The model predictions were used to identify candidate frit compositions for each SB6 projection and to provide some guidance to SRR on washing and blending strategies for SB6 preparation. This report presents a chronological review of this process and summarizes the findings at each stage. Following initial feedback from this work, the number of washes in Tank 51 was reduced to increase the projected sodium concentration in SB6. Analyses of predicted frit performance before and after a potential decant of Tank 40 showed that the post-decant SB6 composition would be difficult to process with any frit composition and that this scenario should be avoided. Based on the most recent SB6 projections (February 2010 SB6 composition projections developed at SRNL using the measured SB6 qualification sample composition and the revised Tank Farm washing plan), Frit 418 appears to be viable for SB6 processing at a target waste loading of 36%. A Nominal Stage PCCS Measurement Acceptability Region (MAR) assessment gave projected operating windows of 25-41% waste loading, limited by predictions of nepheline crystallization. The projected operating window is reduced to 25-38% waste loading when anticipated compositional variation is considered, again limited by predictions of nepheline crystallization. Blend points between 62 and 40 inches of Sludge Batch 5 (SB5) heel in Tank 40 had no practical impact on the projected performance of Frit 418. This assessment is made from a paper study approach only and assumes that no decant of Tank 40 will occur during SB6 processing. A decant of Tank 40 would reduce the Na2O concentration in Tank 40 to a point where it would be very difficult to target a waste loading of 36% for SB6 with Frit 418. The performance of Frit 418 with SB6 is limited by predictions of nepheline crystallization, which is a durability limiting constraint. Alternatives to Frit 418 are available that can provide equivalent projected operating windows and are limited by process related constraints (i.e., liquidus temperature predictions) rather than durability limiting constraints. A separate memorandum has recently been issued that discusses the use of Frit 418 for SB6 vitrification.1 potential differences in melt rate among these alternative frits will be discussed in a forthcoming technical report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Note on the Effects of Linear Topology Preservation in Monte Carlo Simulations of Knotted Proteins

Monte Carlo simulations are a powerful technique and are widely used in different fields. When applied to complex molecular systems with long chains, such as those in synthetic polymers and proteins, they have the advantage of providing a fast and computationally efficient way to sample equilibrium ensembles and calculate thermodynamic and structural properties under desired conditions. Conformational Monte Carlo techniques employ a move set to perform the transitions in the simulation Markov chain. While accepted conformations must preserve the sequential bonding of the protein chain model and excluded volume among its units, the moves themselves may take the chain across itself. We call this a break in linear topology preservation. In this manuscript, we show, using simple protein models, that there is no difference in equilibrium properties calculated with a move set that preserves linear topology and one that does not. However, for complex structures, such as those of deeply knotted proteins, the preservation of linear topology provides correct equilibrium results but only after long relaxation. In any case, to analyze folding pathways, knotting mechanisms and folding kinetics, the preservation of linear topology may be an unavoidable requirement.

Especial, João N. C. (ORCID:0000000254765370)↗

SALTSTONE 2QCY08 TCLP RESULTS

A Saltstone waste form was prepared in the Savannah River National Laboratory from a Tank 50H sample and Z-Area premix material for the second quarter of calendar year 2008 (2QCY08). After the prescribed 28 day cure, samples of the saltstone were collected, and the waste form was shown to meet the South Carolina Hazardous Waste Management Regulations (SCHWMR) R.61-79.261.24 and R.61-79.268.48(a) requirements for a nonhazardous waste form with respect to RCRA metals and underlying hazardous constituents. These analyses met all quality assurance specifications of USEPA SW-846. The Saltstone Production Facility (SPF) receives waste from Tank 50H for treatment. In the second quarter of the 2008 calendar year (2QCY08), Tank 50 accepted transfers of approximately 21 kgal from the Effluent Treatment Project (ETP) waste, approximately 3 kgal from Tank 710--the H-Canyon General Purpose Evaporator, and approximately 23 kgal form the Modular Caustic Side Solvent Extraction Unit (MCU) Decontaminated Salt Solution Hold Tank (DSS-HT). The Saltstone Grout Sampling plan provides the South Carolina Department of Health and Environmental Control (SCDHEC) with the chemical and physical characterization strategy for the salt solution which is to be disposed of in the Z-Area Solid Waste Landfill (ISWLF). During operation, samples were collected from Tank 50H and grout samples prepared to determine the non-hazardous nature of the grout to meet the requirements of the South Carolina Hazardous Waste Management Regulations (SCHWMR) R.61-79.261.24(b) and R.61-79.268.48(a). SRNL was asked to prepare saltstone from a sample of Tank 50H obtained June 5, 2008, during 2QCY08 processing to determine the non-hazardous nature of the grout. The samples were cured and shipped to Babcock & Wilcox Technical Services Group-Radioisotope and Analytical Chemistry Laboratory (B&WTSG-RACL) to perform the Toxic Characteristic Leaching Procedure (TCLP)2 and subsequent extract analysis on saltstone samples for the analytes required for the quarterly analysis saltstone sample. In addition to the eight toxic metals-arsenic, barium, cadmium, chromium, mercury, lead, selenium and silver-analytes included the underlying hazardous constituents (UHC) antimony, beryllium, nickel, and thallium which could not be eliminated from analysis by process knowledge.3 B&WTSG-RACL provided subsamples to GEL Laboratories, LLC for analysis for the UHCs benzene, phenols and total and amenable cyanide.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Incorporation of 40 CFR 192 as an ARAR when Implementing MARSSIM (USACE Input to the MARSSIM Committee for MARSSIM Revision 2) - 18526

One example special case for Final Status Surveys (FSSs) occurs at Uranium Mill Tailings Radiation Control Act of 1978 (UMTRCA) sites at which the radioactive materials are from the processing of uranium or thorium ores for their source material content. At these sites, EPA's Health and Environmental Protection Standards for Uranium and Thorium Mill Tailings, in 40 CFR 192, are applicable. Also, 40 CFR 192 may be invoked at non-UMTRCA sites through the CERCLA as an Applicable or Relevant and Appropriate Requirement (ARAR) due to the presence of radium (Ra)-226 or Ra-228, even though the source of residual radioactive material was not a uranium or thorium mill tailings facility. However, the regulatory requirements in these standards infringe on some of the recommendations in the Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM). Specifically, the soil cleanup standards for Ra-226 or Ra-228 are specified as averages over an area of 100 square meters (m{sup 2}). Note that in the 40 CFR 192 rulemaking, an averaging area of 100 m{sup 2} was used as a reasonable footprint for a home. One goal of the 40 CFR 192 standards was to protect future homes from indoor radon, and the specified averaging area was a component implemented for the protection of health. In addition, 40 CFR 192 is silent regarding elevated measurement criteria (EMC)-type requirements for smaller areas of elevated radioactive material within the 100-m{sup 2} footprint. At UMTRCA sites and CERCLA sites where UMTRCA is an ARAR, the following approach for FSSs is acceptable: - Survey units (SUs) may be classified, as appropriate, and survey activities may be adjusted accordingly for Class 1, Class 2, or Class 3 SUs. - Class 1 soil SUs should provide for evaluation of portions that are no greater than 100 m{sup 2} in size, consistent with the 40 CFR 192 standards. - Class 2 and 3 soil SUs are not expected to exceed the 40 CFR 192 soil cleanup standard, so they do not require evaluation of portions that are no greater than 100 m{sup 2} in size. - Compliance with 40 CFR 192 can be demonstrated through analysis of soil samples or composite soil samples from each SU, in conjunction with gamma radiation scanning or in situ gamma radiation measurements of each SU. When appropriate, these gamma radiation scans or in situ measurements correlated to soil sampling may be used in place of soil sampling. - By demonstrating that the average over 100 m{sup 2} meets the 40 CFR 192 soil cleanup standard, the EMC criteria for small elevated areas of activity are not required for the purposes of MARSSIM, but may be developed. These minor modifications to the standard MARSSIM radiological survey approach are acceptable for UMTRCA sites or CERCLA sites where UMTRCA is an ARAR. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sample Results From The Interim Salt Disposition Program Macrobatch 7 Tank 21H Qualification Samples

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 7 for the Interim Salt Disposition Program (ISDP). An ARP and several ESS tests were also performed. This document reports characterization data on the samples of Tank 21H as well as simulated performance of ARP/MCU. No issues with the projected Salt Batch 7 strategy are identified, other than the presence of visible quantities of dark colored solids. A demonstration of the monosodium titanate (0.2 g/L) removal of strontium and actinides provided acceptable 4 hour average decontamination factors for Pu and Sr of 3.22 and 18.4, respectively. The Four ESS tests also showed acceptable behavior with distribution ratios (D(Cs)) values of 15.96, 57.1, 58.6, and 65.6 for the MCU, cold blend, hot blend, and Next Generation Solvent (NGS), respectively. The predicted value for the MCU solvent was 13.2. Currently, there are no models that would allow a prediction of extraction behavior for the other three solvents. SRNL recommends that a model for predicting extraction behavior for cesium removal for the blended solvent and NGS be developed. While no outstanding issues were noted, the presence of solids in the samples should be investigated in future work. It is possible that the solids may represent a potential reservoir of material (such as potassium) that could have an impact on MCU performance if they were to dissolve back into the feed solution. This salt batch is intended to be the first batch to be processed through MCU entirely using the new NGS-MCU solvent.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Streamlining and Transparently Automating Complex Waste Determinations at Los Alamos National Laboratory - 17286

Environmental programs at Los Alamos National Laboratory (LANL) generate a large amount of sampling activities that can result in waste that needs to be characterized and properly disposed. Since 2011, sampling results are managed in the cloud-based Environmental Information Management (EIM) database, which contains over 16 million current and historical data records. In many cases, the database's analytical records are used to characterize and dispose waste from environmental operations. Three factors contribute to streamlining of the waste disposition operations: (1) if possible, use of the existing analytical data for waste characterization to avoid additional laboratory analysis; (2) reduction in time spent on data evaluation for various waste acceptance criteria; and (3) choice of the proper and least expensive disposal alternative. Use of the existing analytical data, when allowed by law, creates some paradoxical problems: when chemical analysis is requested with the purpose of characterizing waste, it creates only 100 to 400 analytical records. However, use of exiting analytical data at LANL may lead to evaluation of tens of thousands of analytical records, with many records for each single analyte. This occurs because data were collected for environmental characterization and not waste characterization. To streamline data analysis for waste disposition using existing data, LANL has created a Waste Data Summary (WDS) module in the site's EIM database. Recognizing that waste determination is performed by groups outside the environmental program at LANL, the WDS allows for logically guided data selection for a specific waste determination (solids, liquids, radiological, etc.) and reduces potentially thousands of rows of data into simple formatted data reports that are easy to comprehend and process. This allows the waste evaluators to review data using multiple approaches to make their own determination on the most appropriate disposal method. There are four basic principles of WDS operation: (1) The highest detected analytical result is evaluated for the selected samples (or the lowest undetected result if there are no detected results); (2) All approved disposal pathways are evaluated; (3) Any failures of the Waste Acceptance Criteria are visibly highlighted to focus the attention of the evaluator; and (4) The decision of the disposal path is left to the trained waste evaluator (WDS does not choose or suggest any disposal paths). The summary results are presented as the set of short data reports. These reports can be divided into two groups: general comparison reports and disposal pathway specific forms. The general comparison forms show all Resource Conservation and Recovery Act (RCRA) analytes with pass/fail evaluation and with preference for toxicity characteristic leaching procedure (TCLP) results (or 20x rule) for solid samples, the potential RCRA hazard codes assignment for detected analytes, and all rad results. The detected chemical and radioactivity results are compared to the background values and to Soil Screening and Soil Action limits (SSL/SAL limits). Disposal pathway specific forms follow Waste Acceptance Criteria requirements for all disposal pathways available at LANL. The programming of the WDS tries to maximize existing data by analyte substitutions (like using gross alpha for necessary alpha emitting isotopes) or by making calculations when analytical results do not agree with legal requirements (like total chlordane in the RCRA regulations, which is most often analyzed and reported as individual isomers). All forms may be annotated by the waste evaluator to provide additional information to support decision making. Upon final decision of a disposal path, the complete dataset used in the evaluation and the WDS forms with annotations is 'frozen' as an un-editable PDF export to document the data used in the waste disposal determination. The streamlined process results in less work for waste evaluators and reduces overall labor and analytical costs. By comparison, a full review of a 10,000 record parent dataset may take a waste evaluator over a week to review, whereas with the WDS module, the task can be accomplished in less than one hour with clear, reproducible results. These results can be reviewed and checked at any time by quality assurance personnel, thus ensuring transparency in the decision making process. LANL believes this approach has broad applicability to other sites where waste determination is based on review of existing data collected for more generalized environmental purposes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application of real rock pore-threat statistics to a regular pore network model

This work reports the application of real rock statistical data to a previously developed regular pore network model in an attempt to produce an accurate simulation tool with low computational overhead. A core plug from the St. Peter Sandstone formation in Indiana was scanned with a high resolution micro CT scanner. The pore-throat statistics of the three-dimensional reconstructed rock were extracted and the distribution of the pore-throat sizes was applied to the regular pore network model. In order to keep the equivalent model regular, only the throat area or the throat radius was varied. Ten realizations of randomly distributed throat sizes were generated to simulate the drainage process and relative permeability was calculated and compared with the experimentally determined values of the original rock sample. The numerical and experimental procedures are explained in detail and the performance of the model in relation to the experimental data is discussed and analyzed. Petrophysical properties such as relative permeability are important in many applied fields such as production of petroleum fluids, enhanced oil recovery, carbon dioxide sequestration, ground water flow, etc. Relative permeability data are used for a wide range of conventional reservoir engineering calculations and in numerical reservoir simulation. Two-phase oil water relative permeability data are generated on the same core plug from both pore network model and experimental procedure. The shape and size of the relative permeability curves were compared and analyzed and good match has been observed for wetting phase relative permeability but for non-wetting phase, simulation results were found to be deviated from the experimental ones. Efforts to determine petrophysical properties of rocks using numerical techniques are to eliminate the necessity of regular core analysis, which can be time consuming and expensive. So a numerical technique is expected to be fast and to produce reliable results. In applied engineering, sometimes quick result with reasonable accuracy is acceptable than the more time consuming results. Present work is an effort to check the accuracy and validity of a previously developed pore network model for obtaining important petrophysical properties of rocks based on cutting-sized sample data.

58 GEOSCIENCES↗

Application of real rock pore-throat statistics to a regular pore network model

This work reports the application of real rock statistical data to a previously developed regular pore network model in an attempt to produce an accurate simulation tool with low computational overhead. A core plug from the St. Peter Sandstone formation in Indiana was scanned with a high resolution micro CT scanner. The pore-throat statistics of the three-dimensional reconstructed rock were extracted and the distribution of the pore-throat sizes was applied to the regular pore network model. In order to keep the equivalent model regular, only the throat area or the throat radius was varied. Ten realizations of randomly distributed throat sizes were generated to simulate the drainage process and relative permeability was calculated and compared with the experimentally determined values of the original rock sample. The numerical and experimental procedures are explained in detail and the performance of the model in relation to the experimental data is discussed and analyzed. Petrophysical properties such as relative permeability are important in many applied fields such as production of petroleum fluids, enhanced oil recovery, carbon dioxide sequestration, ground water flow, etc. Relative permeability data are used for a wide range of conventional reservoir engineering calculations and in numerical reservoir simulation. Two-phase oil water relative permeability data are generated on the same core plug from both pore network model and experimental procedure. The shape and size of the relative permeability curves were compared and analyzed and good match has been observed for wetting phase relative permeability but for non-wetting phase, simulation results were found to be deviated from the experimental ones. Efforts to determine petrophysical properties of rocks using numerical techniques are to eliminate the necessity of regular core analysis, which can be time consuming and expensive. So a numerical technique is expected to be fast and to produce reliable results. In applied engineering, sometimes quick result with reasonable accuracy is acceptable than the more time consuming results. Present work is an effort to check the accuracy and validity of a previously developed pore network model for obtaining important petrophysical properties of rocks based on cutting-sized sample data. Introduction

42 ENGINEERING↗