Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accelerated beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Reevaluation of spin-orbit dynamics of polarized e+e- beams in high energy circular accelerators and storage rings: An approach based on a Bloch equation

We give an overview of our current/future analytical and numerical work on the spin polarization in high-energy electron storage rings. Our goal is to study the possibility of polarization for the CEPC and FCC-ee. Our work is based on the so-called Bloch equation for the polarization density introduced by Derbenev and Kondratenko in 1975. We also give an outline of the standard approach, the latter being based on the Derbenev–Kondratenko formulas.

Physics↗

An Evolutionary Algorithm Approach to Multi-Pass ERL Optics Design

An Energy Recovery Experiment at CEBAF (ER@CEBAF) is aimed at demonstrating high energy, low current, multi-pass energy recovery at the existing 12 GeV CEBAF accelerator. The beam break-up instability, limiting the maximum beam current, can be controlled through minimizing beta functions for the lowest energy pass, which gives a preference to strongly focusing optics, e.g. a semi-periodic FODO lattice. On the other hand, one needs to limit beta function excursions, caused by under focusing, at the higher energy passes, which in turn favors weakly focusing linac optics. Balancing both effects is the main objective of proposed multi-pass linac optics optimization. Here, we discuss an optics design process for ER@CEBAF transverse optics using a genetic algorithm.

Neththikumara, I.↗

Ultrashort Laser Pulse Shaping and Characterization for Tailored Electron Bunch Generation

Temporally shaped laser pulses are desirable in various applications including emittance reduction and beam-driven acceleration. Pulse shaping techniques enable flexible controls over the longitudinal distribution of electron bunches emitted from the photocathode. While direct manipulation and measurement of an ultrashort pulse can be challenging in the time domain, both actions can be performed in the frequency domain. In this paper, we report the study and development of laser shaper and diagnostics at Argonne Wakefield Accelerator (AWA). Simulations of the shaping process for several sought-after shapes are presented along with the temporal diagnosis. Status of the experiment at the AWA facility is also discussed.

43 PARTICLE ACCELERATORS↗

Optics reconstruction in the SCL section of the FNAL Linac

The Side-Coupled Linac (SCL) section of the FNAL linac accelerates the beam from 116 MeV to 401.5 MeV, operating at 22-24 mA beam current. Transverse focusing is performed by 32 quadrupoles, and the beam orbit is guided by 19 dipole correctors and measured by 29 BPMs. The bunch length is measured in a single location by a Bunch Shape Monitor (BSM). This paper presents a three-step reconstruction of the machine optics. First, the transverse and longitudinal Twiss parameters at the start of the SCL section are determined using quadrupole scans and BSM measurements at different settings of an upstream cavity. Second, the quadrupole calibrations are adjusted based on differential-trajectory measurements. Finally, the beam is propagated along the SCL linac using the code TraceWin. A comparison between TraceWin simulations and the beam envelope measured by the 12 wire scanners of the SCL linac was performed. Transverse and longitudinal beam parameters at the entrance and exit of the SCL section will be reported.

Carneiro, Jean-Paul [Fermilab]↗

A multi-institution collaboration to study copper wire hybrid and laser-cut foil X-pinches

X-pinches are a pulsed power wire-array configuration that produce nanosecond and micron-scale X-ray sources with numerous applications. The earliest embodiment of the X-pinch inspired its name, as it is typically composed of two or more fine (5-50 µm) wires crossed into the shape of an X (Fig. 1a). The ‘X’ ablates when subjected to large (10 1 -10 4 kA), fast-rising (~1 kA/ns) currents, and extreme magnetic pressure at the cross-point constricts the ablated plasma, which develops instabilities and then pinches to near-zero radius, localized ‘hot spots’, emitting X-rays from a sub-nanosecond and 1 µm scale source characteristic of a hot (~1 keV), dense (10% solid density) plasma. A subsequent gap forms where the hot spot(s) occurred, across which substantial potential accelerates electron beams (e-beams) that generate larger, longer-lasting X-ray bursts composed of harder X-rays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of Additive Manufacturing Capabilities for Processing Refractory Alloys Under the Mo-99 Program

The enriched 100 Mo target, denoted as aMo, that Northstar Medical Radioisotopes is developing to produce 99 Mo from an accelerator-based method is a disk-type geometry with a 0.5–0.715 mm thickness and a 29 mm outer diameter. A press and sinter method was adopted to fabricate these samples from aMo powder feedstock. Inherent porosity from the press and sinter method makes the disks more easily dissolvable during 99 Mo postprocessing. However, the disk-type geometry will be subject to thermal stresses due to temperature variations once the geometry is in line with the accelerated electron beam, causing warping and possible failure. Additive manufacturing (AM) processes such as laser powder bed fusion (LPBF) enable the manufacturing of custom, complex geometries that may otherwise be difficult to produce with more conventional methods (e.g., press and sinter approach). Therefore, the National Nuclear Security Administration’s Molybdenum-99 Program invested in developing an AM facility dedicated to processing and printing refractory powders. This report details the LPBF process, how irregular refractory powder can be prepared for LPBF, and the equipment that is available to support the program.

36 MATERIALS SCIENCE↗

Interface Box for Dual Power Amplifier Modulators in Main Injector

The Proton Improvement Plan II (PIP-II) aims to enhance the current Fermilab particle accelerator complex to intensify and accelerate more beam. To achieve this, a second power amplifier will be added to the Main Injector (MI) cavities. However, the control unit could only read signals coming from the previous power supplies, so the interface box was designed to facilitate the issue.

Ayala, Diana↗

Successful Cleanroom Installation of PIP-II SSR2 Coupler Using Robotic Arm

The Fermilab Side-Coupled Linac accelerates H- beam from 116 MeV to 400 MeV through seven 805 MHz modules. Twelve wire scanners are present in the Side Coupled Linac and four are present in the transfer line between the Linac and the Booster synchrotron ring. These wire scanners act as important diagnostic instruments to directly collect information on the beam s transverse distribution. The manipulation of the conditions of wire scanner data collection enables further characterization of the beamline, such as calculating emittance and the Twiss parameters of the beam at select regions. Here we present the results of these studies and characterization of the non-Gaussian transverse beam distribution observed.

Narug, C.↗

Snakes for the Hadron Storage Ring

The Electron Ion Collider calls for collisions of polarized proton and polarized helion beams on polarized electron beams. To preserve polarization of these polarized hadron beams during acceleration, six full helical snakes will be installed. As there are currently 4 snakes in RHIC, the remaining two snakes will be made from existing rotator magnet coils. The existing snakes are made from only right-handed helices where the rotator magnets are made from both right handed and left handed helicity magnets. In order for a sufficient stock of spare coils, one snake will be made of left handed coils. Simulations using Opera field maps in zgoubi show the left handed snake has sufficient range to provide the desired snake precession axes for helions and protons with the existing power supplies. This is an overview of the right and left handed snake assemblies and their effects.

43 PARTICLE ACCELERATORS↗

Assessment of 180,182, 183,184,186 W Photonuclear Data

When electron beams from accelerators are stopped in thick targets made of materials with a high atomic number (or high-Z targets), they produce photons through braking radiation (commonly known as bremsstrahlung). The efficiency of photon production increases with the atomic number (Z). Tungsten is commonly chosen as a bremsstrahlung converter in both research and medical linear accelerators due to its high Z, large bremsstrahlung cross section, high melting point, and excellent thermal conductivity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fusing Quantitative-Phase Imaging with Airy Light- Sheet Microscopy

We report the integration of quantitative-phase imaging (QPI) with light-sheet (LS) fluorescent microscopy on to a standard inverted microscope that retains compatibility with microfluidics. QPI enables label-free imaging and number-density quantification of single cells and their organelles. Conversely, LS yields considerable speed and phototoxicity gains in quantifying the 4D dynamics of gene-encoded fluorescent biomarkers. We will detail the system design that relied on spatial light interferometry for QPI and an accelerating Airy- beam light-sheet for fluorescence, its performance, as well as results of a representative multivariate imaging analysis of single-cell metabolism.

imaging, lattice light sheet, Yarrowia lipolytica,↗

Interface Box for Dual Power Amplifier Modulators in Main Injector

The Proton Improvement Plan II (PIP-II) aims to enhance the current Fermilab particle accelerator complex to intensify and accelerate more beam. To achieve this, a second power amplifier will be added to the Main Injector (MI) cavities. However, the control unit could only read signals coming from the previous power supplies, so the interface box was designed to facilitate the issue.

Ayala, Diana↗

Beam optics design of a prototype 20 kW conduction-cooled SRF accelerator for medical sterilization

Superconducting technology has significantly advanced the capabilities of particle accelerators, facilitating higher beam-power operations for fundamental research at a comparatively lower cost. However, the conventional implementation of superconducting technology introduces complexities in the form of cryogenic plants, cryogenic distribution systems and substantial construction and operational cost. In response to these challenges, recent research efforts at Fermilab have been dedicated to the development of a cryogen-free, conduction-cooled Nb3Sn-based superconducting technology. This paper outlines the beam optics design of a 20-kW conduction-cooled compact superconducting accelerator for medical sterilization. The paper reviews both the physics and practical constraints associated with high beam-power operation within the context of industrial applications. The focus is on providing insights into the potential of this innovative technology to overcome existing challenges and pave the way for more accessible and efficient industrial particle accelerators.

Saini, A. [Fermilab]↗

Beam Optics Design of A Prototype 20 kW Conduction-Cooled SRF Accelerator for Medical Sterilization

Superconducting technology has significantly advanced the capabilities of particle accelerators, facilitating higher beam-power operations for fundamental research at a comparatively lower cost. However, the conventional implementation of superconducting technology introduces complexities in the form of cryogenic plants, cryogenic distribution systems and substantial construction and operational cost. In response to these challenges, recent research efforts at Fermilab have been dedicated to the development of a cryogen-free, conduction-cooled Nb3Sn-based superconducting technology. This paper outlines the beam optics design of a 20-kW conduction-cooled compact superconducting accelerator for medical sterilization. The paper reviews both the physics and practical constraints associated with high beam-power operation within the context of industrial applications. The focus is on providing insights into the potential of this innovative technology to overcome existing challenges and pave the way for more accessible and efficient industrial particle accelerators.

43 PARTICLE ACCELERATORS↗

Beam Optics Design of a Prototype 20 KW Conduction-cooled SRF Accelerator for Medical Sterilization

Superconducting technology has significantly advanced the capabilities of particle accelerators, facilitating higher beam-power operations for fundamental research at a comparatively lower cost. However, the conventional implementation of superconducting technology introduces complexities in the form of cryogenic plants, cryogenic distribution systems and substantial construction and operational cost. In response to these challenges, recent research efforts at Fermilab have been dedicated to the development of a cryogen-free, conduction-cooled Nb3Sn-based superconducting technology. This paper outlines the beam optics design of a 20-kW conduction-cooled compact superconducting accelerator for medical sterilization. The paper reviews both the physics and practical constraints associated with high beam-power operation within the context of industrial applications. The focus is on providing insights into the potential of this innovative technology to overcome existing challenges and pave the way for more accessible and efficient industrial particle accelerators.

43 PARTICLE ACCELERATORS↗

Upgrade to Fixed and Translating Scintillation-based Loss Detector System in the Fermilab Drift Tube Linac

The closed-off structure of the Fermilab Drift Tube Linac precludes a robust array of instrumentation from directly monitoring the H- beam that is accelerated from 750 keV to 116 MeV. To improve beam tuning and operational assessment of Drift Tube Linac performance, scintillator-based loss monitors were previously installed along the exterior of the first two accelerating cavities to assess low energy beam losses. Here we present a recent upgrade to the loss monitor system, including significant improvements in analog signal processing to address baseline-interfering noise; digitization of the signals to enable regular operational use and tuning; and a new remote operation upgrade of the translating loss monitor with precise positioning of the loss monitor along its nine-foot track. Data from the fixed and translating detectors collected under varying beam conditions validate the utility of the upgrade.

Chen, E. V. [Fermilab]↗

Upgrade to Fixed and Translating Scintillation-Based Loss Detector System in the Fermilab Drift Tube Linac

The closed-off structure of the Fermilab Drift Tube Linac precludes a robust array of instrumentation from directly monitoring the H- beam that is accelerated from 750 keV to 116 MeV. To improve beam tuning and op-erational assessment of Drift Tube Linac performance, scintillator-based loss monitors were previously installed along the exterior of the first two accelerating cavities to assess low energy beam losses. Here we present a recent upgrade to the loss monitor system, including significant improvements in analog signal processing to address baseline-interfering noise; digitization of the signals to enable regular operational use and tuning; and a new remote operation upgrade of the translating loss monitor with precise positioning of the loss monitor along its nine-foot track. Data from the fixed and translating de-tectors collected under varying beam conditions validate the utility of the upgrade.

Chen, Erin V. [Fermilab] (ORCID:0000000215467899)↗