Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

The Quantum Nature and Mass of the Neutrino. FY20 Annual Laboratory Continuation Progress Report

Over the last 100 years we have learned a much about the neutrino, but there remain interesting questions about this weakly interacting particle. In particular, at LLNL we are developing experiments to measure the mass and the quantum nature of the neutrino. The 2015 long range plan recommended tonne-scale neutrinoless double beta decay experiments as the top new project priority and this experiment will target the quantum nature of the neutrino. The LLNL team is motivated and focused on developing the best technology for this experiment which is a liquid xenon time project chamber called nEXO. On a longer time scale, LLNL is also developing technology to measure the neutrino mass with tritium decay experiments. Work on nEXO at LLNL started in 2015 with an LDRD and program development funds to develop the nEXO concept, publish sensitivity predictions, explore alternatives and risks, and to build a credible project team and this effort is on going. In addition, we received research funding from DOE-SC NP and LLNL manages pre-conceptual R&D for the nEXO collaboration a portion of which is executed at LLNL. The Project 8 effort is solely funded by LLNL LDRD, and ends this year. A second LDRD effort is focused on repurposing cyclotron radiation emission spectroscopy for eV-scale X-ray detection. This second effort, while separated from Project 8, still has scientific and technical commonalities with Project 8. The funding for this X-ray detection effort will continue for one more year. LLNL has a long history of building large projects, science projects and time projection chambers, but nEXO is in fact the first project of this scale that LLNL is prepared to lead for DOE-SC NP.We have the tools, skills, people and motivation to make nEXO a reality. The current program development dollars are used to prepare the nEXO concept for down select and CD1. These internal LLNL dollars pay for a number of things including project staff to organize the nEXO collaboration for the various reviews that lie ahead, to develop the draft plans and structure to manage the project as well as setting up an external advisory committee. The current LDRD is exploring alternatives that effect the risk profile as well as possible performance improvements. The DOE-SC NP base funding is targeted at simulation and analysis of the nEXO concept in preparation for the down select and refinement of the understanding of the detector as well as scientific effort on the large xenon test stand (LXTS) that will burn down one of the largest risks to the nEXO project. Lastly, LLNL is leading the pre-conceptual R&D effort and managing the funds for the nEXO collaboration. The results of this effort are reported elsewhere, but the scope of this executed at LLNL will be reported here and is primarily the engineering and construction of the LXTS experiment. The primary technical contribution of LLNL to the Project 8 concept is the formation and study of atomic tritium. Atomic tritium is necessary for Project 8 to reach the ultimate sensitivity. LLNL has considerable experience with tritium and is well suited for this crucial work. Although the focus of this work is strictly fundamental science, there has already been one significant spinoff to develop a new means to measure radio xenon in the air

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved noise performance from the next-generation buried-channel p-MOSFET SiSeROs

The Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors. Developed at MIT Lincoln Laboratory, this technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor source-drain current is modulated by the transfer of charge into the internal gate. At Stanford, we have developed a readout module based on the drain current of the on-chip transistor to characterize the device. In our earlier work, we characterized a number of first prototype SiSeROs with the MOSFET transistor channels at the surface layer. An equivalent noise charge (ENC) of around 15 electrons root mean square (RMS) was obtained. In this work, we examine the first buried-channel SiSeRO. Here we have achieved substantially improved noise performance of around 4.5 electrons root mean square (RMS) and a full width half maximum (FWHM) energy resolution of 132 eV at 5.9 keV, for a readout speed of 625 kpixel/s. We also discuss how digital filtering techniques can be used to further improve the SiSeRO noise performance. Additional measurements and device simulations will be essential to further mature the SiSeRO technology. This new device class presents an exciting new technology for the next-generation astronomical X-ray telescopes requiring fast, low-noise, radiation-hard megapixel imagers with moderate spectroscopic resolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Laser-driven flash x-ray radiography of a shocked metallic foil

Characterizing hydrodynamic instability evolution in millimeter-scale, high-Z foils is crucial for understanding complex phenomena in high-energy-density physics. Here, we demonstrate a proof-of-concept, laser-driven flash x-ray radiography platform tailored for two-dimensional linear density mapping in shocked high-Z foils. Using chromium (Cr) foils with internal shockwaves (∼100 μm width), our platform achieves a spatial resolution of 59.8 ± 1.4 μm by employing a broadband x-ray source extending into the hundreds of keV range. The setup combines a compound parabolic concentrator cone with a tantalum wire target, a magnetic field to deflect residual transmitted electrons, and a copper casing to shield the sides and rear of the image plate pack. By varying the delay of the short-pulse beam driving the flash x-ray source, we resolve shockwave dynamics, specifically the velocity, position, width, and density profile, within the Cr foil. Reported experimental results are consistent with the corresponding hydrodynamics and radiation transport simulations, which accurately reproduce the measured electron and x-ray source terms. These developments enable the conversion of shockwave radiographs into two-dimensional density maps, enhancing interpretability for hydrodynamic instability evolution applications and validating the simulation approach.

36 MATERIALS SCIENCE↗

A New Residual Strain Mapping Program Using Energy Dispersive X-Ray Diffraction at the Advanced Photon Source

Here, the ability to non-destructively map the residual strain field inside an engineering component is important for predicting its fatigue life or developing processing methods to prevent failure or enhance performance. In this paper, we describe a new residual strain mapping program at the Advanced Photon Source, Argonne National Laboratory. The new program is based on energy dispersive x-ray diffraction (EDXRD). It is capable of non-destructively penetrating a several- cm thick polycrystalline sample fabricated from engineering alloys using high-energy x-rays and measuring the residual strain field with mm or better spatial resolution and approximately ±1 x 10 -4 strain resolution. A multi-element detector array is employed to measure multiple strain components simultaneously. The residual strain mapping setup is augmented with a high-energy tomography capability, allowing precise alignment of the material volume of interest for residual strain mapping and providing a complementary view of the structure to understand the measured strain field. These measurement capabilities are demonstrated using several strain mapping examples ranging from polycrystalline structural alloys to biological materials. We also provide some guidance for the future users of the program for a successful residual strain mapping experiment. We are expanding the capabilities of the new setup with various in situ capabilities including thermo-mechanical loading.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of non-monochromaticity in laboratory XPS: Representative example of pyrimidine

The Mg and Al K α radiation used in standard laboratory sources for X-Ray Photoelectron Spectroscopy, XPS, is not naturally monochromatic because the spin orbit splitting of the Mg and Al 2p shells is not normally resolved. However, since the 2p spin-orbit splitting of the K α1 and K α2 X-Rays in these light atoms is small, it is normally ignored. In the present work, the consequences of the departure from monochromaticity is explicitly shown to be extremely small for the representative case of the C(1 s) ionizations in the XPS of the pyrimidine molecule. Furthermore, this conclusion is general and does not depend on the particular molecule studied since the K α1 and K α2 BE splittings reflect the spin-orbit splittings in the X-Ray source.

Binding Energies (BEs)↗

Peculiarities of planar shockwave interaction with air–water interface and solid target

We present the results of the research on underwater electrical explosion of planar copper wire arrays, accompanied by the generation of a planar shock, using the synchrotron-based phase-contrast radiography imaging capabilities of the ID19 beamline at the European Synchrotron Radiation Facility. It is shown that the interaction of a strong shock with an air–water interface leads to additional acceleration of the wire expansion due to a rarefaction wave along with the emergence of micro-jets. In the case of a target placed above the array, we observed the formation of a cavity between the array and the target due to the interaction of two rarefaction waves. Furthermore, the results of two-dimensional hydrodynamic simulations of the wire explosion and the interaction of the generated shock with the water–air and water-target interfaces showed good agreement with experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gamma-ray imaging of inertial confinement fusion implosions reveals remaining ablator carbon distribution

The joint LANL/LLNL nuclear imaging team has acquired the first gamma-ray images of inertial confinement fusion implosions at the National Ignition Facility. The gamma-ray image provides crucial information to help characterize the inertially confined fuel and ablator assembly at stagnation, information that would be difficult to acquire from neutron or x-ray observations. Gamma imaging visualizes both gamma radiation emitted directly in deuterium–tritium (DT) fusion reactions as well as gamma rays produced when DT fusion neutrons scatter inelastically on carbon nuclei in the remaining ablator of the fuel capsule. The resulting image provides valuable information on the position and density of the remaining ablator and potential contamination of the hot spot—a powerful diagnostic window into the capsule assembly during burn.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of drive pulse shape on graded metal pushered single shell capsule implosions on the National Ignition Facility

Graded metal pushered single shells (PSS) are a viable alternative to low-Z capsules (Z is the atomic number) for indirect drive inertial confinement fusion implosions due to enhanced core tamping and radiation trapping, but they can be compromised by the pusher mixing with the fuel. We compare 2-shock and 3-shock laser pulses for Be/Cr PSS capsules filled with deuterium–tritium gas fuel at 6 mg/cc density. 1D radiation-hydrodynamic simulations predict higher core compression and, hence, ∼2× higher fusion yield for the 3-shock drive than for 2-shock. Nevertheless, we observe similar core ion temperatures and fusion yields for both drives. The implosion burn duration is 25% shorter and the core volume is ∼2.5× smaller for the 3-shock drive than for 2-shock, consistent with a higher compression. 1D LASNEX mix simulations using a buoyancy-drag model matching the measured yields also agree with the observed core sizes and burn durations and suggest ∼40% and ∼70% yield degradations for 2-shock and 3-shock drives due to hydrodynamic instabilities and atomic mix at the pusher–fuel interface. At the same time, 2D HYDRA simulations show that mid-mode (2–250) instability degradations are negligible for the 2-shock implosion (9%) and significant (45%) for 3-shock. Subtracting these from the 1D mix simulations, we infer similar degradations from high-mode instabilities and atomic mix for both drives. Due to its robustness to mid-mode instabilities, future pusher–gas mix studies will use the 2-shock drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical constants of magnetron sputtered aluminum in the range 17–1300 eV with improved accuracy and ultrahigh resolution in the L absorption edge region

This work determines a new set of EUV/x-ray optical constants for aluminum (Al), one of the most important materials in science and technology. Absolute photoabsorption (transmittance) measurements in the 17–1300 eV spectral range were performed on freestanding Al films protected by carbon (C) layers, to prevent oxidation. The dispersive portion of the refractive index was obtained via the Kramers–Kronig transformation. Our data provide significant improvements in accuracy compared to previously tabulated values and reveal fine structure in the Al L 1 and L 2,3 regions, with photon energy step sizes as small as 0.02 eV. The implications of this work in the successful realization of EUV/x-ray instruments and in the validation of atomic and molecular physics models are also discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Multi-device analysis of energy loss duration and pellet penetration with implications for shattered pellet injection in ITER

A robust disruption mitigation system (DMS) requires accurate characterization of key disruption timescales, one of the most notable being the thermal quench (TQ). Recent modeling of shattered pellet injection (SPI) into ITER plasmas, using JOREK and INDEX, suggests long TQ durations (6–10 ms) and slow cold front propagation due to the large plasma size. If validated, these predictions would have an impact on the desired pellet parameters and mitigation strategies for the ITER DMS. To resolve these questions, a database of SPI experiments from several small-to-large sized devices (J-TEXT, KSTAR, AUG, DIII-D, and JET) has been compiled under the auspices of the International Tokamak Physics Activity MHD, disruptions, and control topical group. Analysis of the energy loss duration (proxy for the TQ duration) with machine size is presented for both mixed neon/deuterium (Ne/D) SPI and pure deuterium (D) SPI. Several metrics for the energy loss onset (e.g. soft x-ray signal drop, I p dip, and radiation flash) were considered as the conventional metric, electron cyclotron emission, is often cut-off during SPI. Several scalings with different onset metrics showed an increase in energy loss duration with machine size. The energy loss duration was additionally shown to be a function of the ratio between the number of SPI neon atoms injected and the stored energy. Analysis of the pellet shard position relative to the cold front found that in larger devices, pellets are typically found inboard of the q = 2 surface at the energy loss onset. Lastly, the delay between the pellet shards hitting the q = 2 surface and the energy loss onset was additionally found to increase with machine size. This suggests that the pellet shards in large devices will penetrate faster and further than the cooling front.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Swift /UVOT discovery of Swift J221951−484240: a UV luminous ambiguous nuclear transient

We report the discovery of Swift J221951−484240 (hereafter: J221951), a luminous slow-evolving blue transient that was detected by the Neil Gehrels Swift Observatory Ultraviolet/Optical Telescope (Swift/UVOT) during the follow-up of gravitational wave alert S190930t, to which it is unrelated. Swift/UVOT photometry shows the UV spectral energy distribution of the transient to be well modelled by a slowly shrinking blackbody with an approximately constant temperature of T ∼ 2.5 × 10 4 K. At a redshift z = 0.5205, J221951 had a peak absolute magnitude of M u,AB = −23 mag, peak bolometric luminosity Lmax = 1.1 x 10 45 ergs -1 and a total radiated energy of E > 2.6 × 10 52 erg. The archival Wide-field Infrared Survey Explorer IR photometry shows a slow rise prior to a peak near the discovery date. Spectroscopic UV observations display broad absorption lines in N V and O VI, pointing towards an outflow at coronal temperatures. The lack of emission in the higher H α lines, N I and other neutral lines is consistent with a viewing angle close to the plane of the accretion or debris disc. The origin of J221951 cannot be determined with certainty but has properties consistent with a tidal disruption event and the turn-on of an active galactic nucleus.

79 ASTRONOMY AND ASTROPHYSICS↗

Understanding the deficiency in inertial confinement fusion hohlraum x-ray flux predictions using experiments at the National Ignition Facility

The predicted implosion performance of deuterium-tritium fuel capsules in indirect-drive inertial confinement fusion experiments relies on precise calculations of the x-ray drive in laser-heated cavities (hohlraums). This requires accurate, spectrally dependent simulations of laser to x-ray conversion efficiencies and x-ray absorption losses to the hohlraum wall. A set of National Ignition Facility experiments have identified a cause for the long-standing hohlraum “drive deficit” as the overprediction of gold emission at ~2.5 keV in nonlocal thermodynamic equilibrium coronal plasma regions within the hohlraum. Finally, reducing the emission and absorption opacity in this spectral region by ~20% brings simulations into agreement with measured x-ray fluxes and spectra.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preface for the special topic collection commemorating the career of Charles S. Fadley

This Special Topic Collection in the Journal of Vacuum Science and Technology A has been compiled to celebrate the exceptional contributions of Professor Charles S. Fadley to the fields of photoelectron spectroscopy and surface and interface science. The five reviews and 22 articles contained in this collection cover important challenges, new developments, and current understanding in these fields.

99 GENERAL AND MISCELLANEOUS↗

EIC ESR beam position monitors thermal and thermomechanical study preliminary design

The Electron Ion Collider (EIC) Electron Storage Ring (ESR) Beam Position Monitors (BPM) are designed to monitor the electron beam orbit position on a turn-by-turn and bunch-by-bunch basis in the vacuum chamber. Large variations in ESR fill pattern and bunch intensity imposes a large dynamic range on the BPM system design. And given the large ESR beam current - up to 2.5 A with 1160 x 20 nC bunches – the heating by synchrotron radiation (SR) and beam impedance is a significant concern. The high energy of the electrons – up to 18 GeV – leads to scat tering of the SR that produces high radiation doses and as sociated heating of structures away from the SR impact area. Because of this intense heating, and stringent position stability requirements, an in-depth engineering analysis was carried out. This paper will review the analysis made of the preliminary design and its main outcomes.

43 PARTICLE ACCELERATORS↗

Observation of impurity accumulation and its compatibility with high plasma performance in W7-X

At the W7-X stellarator, the bolometer system has measured an intensive radiation zone in the inner plasma region (at a normalized radius $ρ$ ~ 0.3–0.4) in the hydrogen plasma generated by electron cyclotron resonance heating; it differs from the normal plasma radiation distribution with an edge-localized emission zone. Spectroscopic diagnostics have recorded high-Z elements such as iron. This phenomenon happens in the plasma phases after gas supply turn-off, which results in all impurity relevant diagnostic signals increasing for several seconds. Despite the enhancement of the core radiation, the plasma energy confinement is improved. A transport analysis shows that this impurity radiation behavior is associated with a low diffusion coefficient ($D$~ 0.02 m 2 s -1 ) and a reversal of the convection around the radial position of the emission peak, which, under normal conditions, separates the zones of outward convection in the central (|$V$| ~ 0.1 m s -1 ) and inward convection in the outer region (|$V$| ~ 0.3 m s -1 ). An impurity accumulation around this radial position has been identified. The transport coefficients obtained are comparable with the theoretical predictions of collisional impurity transport. In the plasma phases studied, both impurity and energy confinement are enhanced. The mechanism responsible for the improvement is believed to be a reduction of micro-instabilities associated with the observed steepening of the density profile, initiated by a low edge plasma density (<1.0 × 10 19 m -3 ) after switching off the gas fueling. The normalized temperature and density gradients fulfil the condition for the suppression of ITG turbulence.

suppression of ITG turbulence↗

Halide Perovskites and Their Derivatives for Efficient, High‐Resolution Direct Radiation Detection: Design Strategies and Applications

Abstract The past decade has witnessed a rapid rise in the performance of optoelectronic devices based on lead‐halide perovskites (LHPs). The large mobility‐lifetime products and defect tolerance of these materials, essential for optoelectronics, also make them well‐suited for radiation detectors, especially given the heavy elements present, which is essential for strong X‐ray and γ‐ray attenuation. Over the past decade, LHP thick films, wafers, and single crystals have given rise to direct radiation detectors that have outperformed incumbent technologies in terms of sensitivity (reported values up to 3.5 × 10 6 µC Gy air −1 cm −2 ), limit of detection (directly measured values down to 1.5 nGy air s −1 ), along with competitive energy and imaging resolution at room temperature. At the same time, lead‐free perovskite‐inspired materials (e.g., methylammonium bismuth iodide), which have underperformed in solar cells, have recently matched and, in some areas (e.g., in polarization stability), surpassed the performance of LHP detectors. These advances open up opportunities to achieve devices for safer medical imaging, as well as more effective non‐invasive analysis for security, nuclear safety, or product inspection applications. Herein, the principles behind the rapid rises in performance of LHP and perovskite‐inspired material detectors, and how their properties and performance link with critical applications in non‐invasive diagnostics are discussed. The key strategies to engineer the performance of these materials, and the important challenges to overcome to commercialize these new technologies are also discussed.

36 MATERIALS SCIENCE↗

Radiation transfer in the spectra of short-pulse laser-heated targets

The conditions in laser-produced plasmas are frequently determined with x-ray spectroscopy by comparing calculated to measured spectra. Line spectra from K-shell transitions of low- to mid-atomic number elements are most often used since the important physical processes are well understood and reliable spectra can be readily measured and calculated. Radiation transfer effects due to large optical depths of strong lines can influence the spectra. In this work, the effects of radiation transfer on the emission spectra of short-laser pulse-heated targets are studied. The possible errors made in inferring electron temperature by not including radiation transfer are quantified. The inclusion of radiative transfer in spectral calculations improves the accuracy of typical temperature diagnostics and allows the use of strong lines for diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗