At least 577 records · Page 32

Evaluation of Damage in Medium Voltage Cable Using Machine Learning

Developments in cable test instrumentation coupled with artificial intelligence and machine learning (ML) to aid in interpretation of cable test signals supports the feasibility for automated analysis of reflectometry tests for low voltage power cables. This work seeks to leverage prior ML work and success for low voltage cables to evaluate potential application to medium voltage (2kV to 10kV) installations. The Accelerated and Real-Time Environmental Nodal Assessment (ARENA) Cable Motor Test Bed at Pacific Northwest National Laboratory (PNNL) was used to test a medium voltage cable with several types of damage including thermal aging and low resistance conductor-to-shield faults. The cable was tested using an inductive clamshell coupler to protect the test instruments from the energized cable voltages that would damage the test instruments if coupled directly to the energized conductor.

42 ENGINEERING↗

The Role of Proton Transport in Gating Current in a Voltage Gated Ion Channel, as Shown by Quantum Calculations

Over two-thirds of a century ago, Hodgkin and Huxley proposed the existence of voltage gated ion channels (VGICs) to carry Na + and K + ions across the cell membrane to create the nerve impulse, in response to depolarization of the membrane. The channels have multiple physiological roles, and play a central role in a wide variety of diseases when they malfunction. The first channel structure was found by MacKinnon and coworkers in 1998. Subsequently, the structure of a number of VGICs was determined in the open (ion conducting) state. This type of channel consists of four voltage sensing domains (VSDs), each formed from four transmembrane (TM) segments, plus a pore domain through which ions move. Understanding the gating mechanism (how the channel opens and closes) requires structures. One TM segment (S4) has an arginine in every third position, with one such segment per domain. It is usually assumed that these arginines are all ionized, and in the resting state are held toward the intracellular side of the membrane by voltage across the membrane. They are assumed to move outward (extracellular direction) when released by depolarization of this voltage, producing a capacitive gating current and opening the channel. We suggest alternate interpretations of the evidence that led to these models. Measured gating current is the total charge displacement of all atoms in the VSD; we propose that the prime, but not sole, contributor is proton motion, not displacement of the charges on the arginines of S4. It is known that the VSD can conduct protons. Quantum calculations on the K v 1.2 potassium channel VSD show how; the key is the amphoteric nature of the arginine side chain, which allows it to transfer a proton. This appears to be the first time the arginine side chain has had its amphoteric character considered. We have calculated one such proton transfer in detail: this proton starts from a tyrosine that can ionize, transferring to the NE of the third arginine on S4; that arginine’s NH then transfers a proton to a glutamate. The backbone remains static. A mutation predicted to affect the proton transfer has been qualitatively confirmed experimentally, from the change in the gating current-voltage curve. The total charge displacement in going from a normal closed potential of -70 mV across the membrane to 0 mV (open), is calculated to be approximately consistent with measured values, although the error limits on the calculation require caution in interpretation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of load voltage on thin film cuprous sulfide: Cadmium sulfide solar cells thermally cycled in a simulated space environment

Thin-film Cu2S-CdS solar cells, loaded at various fixed values of load resistance, were thermally cycled for 1429 cycles in a simulated space environment. Cell performance was measured under controlled conditions in air before and after thermal cycling. These data were used to determine the effect of load voltage on cell performance. The performance of the cells was relatively independent of load voltage up to about 0.39 volt. This appears to be a threshold voltage, beyond which there was a significant loss in cell performance. Fortunately, this threshold voltage appears to be sufficiently higher than the maximum power voltage of 0.33 volt so that it can be avoided in most applications.

Smithrick, J. J.↗

Efficiency/reliability design requirements at low output voltage levels.

Higher efficiency and reliability are needed in the rectification used to produce low output voltages. To this end, the application of driven synchronous rectifier circuits is investigated. One reliability problem of such circuits, the ?double-on' resulting from storage time, is illustrated for low output voltages obtained from rectification of the square-wave outputs of low input voltage converters. A comparison of the rectification efficiency and reliability of driven transistor synchronous rectifiers with that of barrier diodes indicates that the choice of rectifiers in low output voltage applications is dependent on both the source and output voltage levels of the application.

Pasciutti, E. R.↗

The interaction of spacecraft high voltage power systems with the space plasma environment

The development of spacecraft with electrical loads that require high voltage power is discussed. The high voltage solar array has been considered for supplying d.c. power directly to high voltage loads such as ion thrusters and communication tubes without intermediate power processing. Space power stations for transferring solar power to earth are being studied in the 40 kilovolt, multikilowatt regime. Analytical and experimental studies have determined that with the advent of high voltage power, new problems will arise through the interaction of the high voltage surfaces with the charged particle environment of space. The interactive environment has been identified and duplicated to some extent in simulation facilities at NASA-Lewis Research Center and at several contractor locations.

Domitz, S.↗

Voltage monitoring system

A description is given of a system for monitoring the voltage at a remote location and determining when the voltage exceeds upper and lower levels. The system includes transmission lines for transmitting the voltage back to a central station and applying such to an amplifier having a pair of outputs. One of the outputs of the amplifier is applied to an oscillograph. The other output is fed through an isolation transformer, a full wave rectifier, to a pair of unijunctional transistor circuits for producing pulses when the voltage exceeds or drops below a predetermined level. These pulses, in turn, energize a relay which turns on the oscillograph for recording the voltages being monitored.

Canicatti, C. L.↗

Voltage stress effects on microcircuit accelerated life test failure rates

The applicability of Arrhenius and Eyring reaction rate models for describing microcircuit aging characteristics as a function of junction temperature and applied voltage was evaluated. The results of a matrix of accelerated life tests with a single metal oxide semiconductor microcircuit operated at six different combinations of temperature and voltage were used to evaluate the models. A total of 450 devices from two different lots were tested at ambient temperatures between 200 C and 250 C and applied voltages between 5 Vdc and 15 Vdc. A statistical analysis of the surface related failure data resulted in bimodal failure distributions comprising two lognormal distributions; a 'freak' distribution observed early in time, and a 'main' distribution observed later in time. The Arrhenius model was shown to provide a good description of device aging as a function of temperature at a fixed voltage. The Eyring model also appeared to provide a reasonable description of main distribution device aging as a function of temperature and voltage. Circuit diagrams are shown.

Johnson, G. M.↗

Flux-flow voltages during guided flux collapse from hollow superconducting cylinders

Voltages across diametrically opposite contact pairs on the outer surface of superconducting Nb tubes are found to depend dramatically upon the spatial configuration of the voltage-measuring leads relative to the positions of the moving magnetic flux lines. Experiments have been conducted to study these voltages for different wall thicknesses and for a variety of arrangements of the leads when flux in the hole and the wall of the Nb tube is made to exit or enter, completely or partially, by applying heat at a narrow strip along its length. Using the critical-state concept, a model for the change of flux and the resulting electric fields in the Nb tube on application of a heat pulse is presented. The resulting time-dependent and time-integrated voltages are calculated in excellent quantitative agreement with the experimental results. These results show that the flux-flow voltages across two contact points on a superconductor arise from the generation of an induced electric field over a chosen path in the superconductor between the contact points and from a change of magnetic flux through the surface bounded by the measuring leads and the chosen path in the superconductor.

Khanna, S. M.↗

Advanced electric propulsion system concept for electric vehicles. Addendum 1: Voltage considerations

The two electric vehicle propulsion systems that best met cost and performance goals were examined to assess the effect of battery pack voltage on system performance and cost. A voltage range of 54 to 540 V was considered for a typical battery pack capacity of 24 k W-hr. The highest battery specific energy (W-hr/kg) and the lowest cost ($/kW-hr) were obtained at the minimum voltage level. The flywheel system traction motor is a dc, mechanically commutated with shunt field control, and due to the flywheel the traction motor and the battery are not subject to extreme peaks of power demand. The basic system uses a permanent-magnet motor with electronic commutation supplied by an ac power control unit. In both systems battery cost were the major factor in system voltage selection, and a battery pack with the minimum voltage of 54 V produced the lowest life-cycle cost. The minimum life-cycle cost for the basic system with lead-acid batteries was $0.057/km and for the flywheel system was $0.037/km.

Raynard, A. E.↗

Forecasting of high voltage insulation performance: Testing of recommended potting materials and of capacitors

Nondestructive high voltage test techniques (mostly electrical methods) are studied to prevent total or catastrophic breakdown of insulation systems under applied high voltage in space. Emphasis is on the phenomenon of partial breakdown or partial discharge (P.D.) as a symptom of insulation quality, notably partial discharge testing under D.C. applied voltage. Many of the electronic parts and high voltage instruments in space experience D.C. applied stress in service, and application of A.C. voltage to any portion thereof would be prohibited. Suggestions include: investigation of the ramp test method for D.C. partial discharge measurements; testing of actual flight-type insulation specimen; perfect plotting resin samples with controlled defects for test; several types of plotting resins and recommendations of the better ones from the electrical characteristics; thermal and elastic properties are also considered; testing of commercial capaciters; and approximate acceptance/rejection/rerating criteria for sample test elements for space use, based on D.C. partial discharge.

Bever, R. S.↗

Incrementally Variable High-Voltage Supply

Programable power supply provides regulated output ranging from 2.5 to 2,500 volts. Exponential digital-to-analog converter provides low-voltage analog signal to power converter and to negative and positive high-voltage regulators. In response, converter furnishes voltage of approximate magnitude represented by analog signal, and regulators adjust voltage to precise magnitude. Entire voltage range covered in 169 steps. Total power consumption expected to be less than 2 watts.

Potter, D. W.↗

Surface interactions and high-voltage current collection

Spacecraft of the future will be larger and have higher power requirements than any flown to date. For several reasons, it is desirable to operate a high power system at high voltage. While the optimal voltages for many future missions are in the range 500 to 5000 volts, the highest voltage yet flown is approximately 100 volts. The NASCAP/LEO code is being developed to embody the phenomenology needed to model the environmental interactions of high voltage spacecraft. Some plasma environment are discussed. The treatment of the surface conductivity associated with emitted electrons and some simulations by NASCAP/LEO of ground based high voltage interaction experiments are described.

Mandell, M. J.↗

Space test program of high-voltage solar array-space plasma interactions

Future spacecraft, notably the proposed Space Station, will require power systems much larger than have previously been flown. It is recognized that at higher voltages, and at the relatively high plasma density present at low Earth orbital altitudes, undesirable interactions between the high voltage solar array and the space plasma will occur. Space experiments on high voltage solar array space plasma interactions in low Earth orbit are an absolute requirement for confident design of a higher voltage solar array. Experiments are presently being identified to provide the necessary space data for calibration of ground testing, validation of analytical models, and development of design guidelines required for confident design of high voltage solar arrays in space. A proposed flight experiment program which is designed to obtain the required data is summarized.

Carruth, M. R., Jr.↗

Arcing and discharges in high-voltage subsystems of Space Station

Arcing and other types of electrical discharges are likely to occur in high-voltage subsystems of the Space Station. Results from ground and space experiments on the arcing of solar cell arrays are briefly reviewed, showing that the arcing occurs when the conducting interconnects in the arrays are at negative potential above a threshold, which decreases with the increasing plasma density. Furthermore, above the threshold voltages the arcing rate increases with the plasma density. At the expected operating voltages (approximately 200 V) in the solar array for the space station, arcing is expected to occur even in the ambient ionospheric plasma. If the ionization of the contaminants increases the plasma density near the high-voltage systems, the adverse effects of arcing on the solar arrays and the space station are likely to be enhanced, In addition to arcing other discharge processes are likely to occur in high-voltage subsystems. For example, Paschen discharge is likely to occur when the neutral density N sub n greater that 10 to the 12th cu cm, the corresponding neutral pressure P greater than 3 x 10 to the -5 Torr.

Singh, N.↗

The effects of ion gun beam voltage on the electrical characteristics of NbCN/PbBi edge junctions

The authors have succeeded in fabricating high-quality submicron NbCN edge junctions using a technique which is commonly used to make Nb edge junctions. A modified commercial ion gun was used to cut an edge in SiO2/NbCN films partially covered with photoresist. An insulating barrier was then formed on the exposed edge by reactive ion beam oxidation, and a counterelectrode of PbBi was deposited. The electrical quality of the resulting junctions was found to be strongly influenced by the ion beam acceleration voltages used to cut the edge and to oxidize it. For low ion beam voltages, the junction quality parameter was as high as Vm = 55 mV (measured at 3 mV), but higher ion beam voltages yielded strikingly poorer quality junctions. In light of the small coherence length of NbN, the dependence of the electrical characteristics on ion beam voltage is presumably due to mechanical damage of the NbCN surface. In contrast, for similar ion beam voltages, no such dependence was found for Nb edge junctions.

Lichtenberger, A. W.↗

Characterization of vertical electric fields and associated voltages induced on a overhead power line from close artificially initiated lightning

Measurements were characterized of simultaneous vertical electric fields and voltages induced at both ends of a 448 m overhead power line by artificially initiated lightning return strokes. The lightning discharges struck ground about 20 m from one end of the line. The measured line voltages could be grouped into two categories: those in which multiple, similarly shaped, evenly spaced pulses were observed, which are called oscillatory; and those dominated by a principal pulse with subsidiary oscillations of much smaller amplitude, which are called impulsive. Voltage amplitudes range from tens of kilovolts for oscillatory voltages to hundreds of kilovolts for impulsive voltages.

Rubinstein, Marcos↗

The effect of electrode temperature on the sparking voltage of short spark gaps

This report presents the results of an investigation to determine what effect the temperature of spark plug electrodes might have on the voltage at which a spark occurred. A spark gap was set up so that one electrode could be heated to temperatures up to 700 degrees C., while the other electrode and the air in the gap were maintained at room temperature. The sparking voltages were measured both with direct voltage and with voltage impulse from ignition coil. It was found that the sparking voltage of the gap decreased materially with increase of temperature. This change was more marked when the hot electrode was of negative polarity. The phenomena observed can be explained by the ionic theory of gaseous conduction, and serve to account for certain hitherto unexplained actions in the operation of internal combustion engines. These results indicate that the ignition spark will pass more readily when the spark-plug design is such as to make the electrodes run hot. This possible gain is, however, very closely limited by the danger of producing preignition. These experiments also show that sparking is somewhat easier when the hot electrode (which is almost always the central electrode) is negative than when the polarity is reversed.

Silsbee, F B↗

Improved Programmable High-Voltage Power Supply

Improved dc-to-dc converter functions as programmable high-voltage power supply with low-power-dissipation voltage regulator on high-voltage side. Design of power supply overcomes deficiencies of older designs. Voltage regulation with low power dissipation provided on high-voltage side.

Castell, Karen↗