At least 577 records · Page 32

Developing Use Cases for Evaluation of ADMS Applications to Accelerate Technology Adoption: Preprint

Grid modernization for the distribution systems comprise of the ability to effectively monitor and manage unplanned events while ensuring reliable operations. Integration of Distributed Energy Resources (DERs) and proliferation of autonomous smart controllers like microgrids and smart inverters in the distribution networks challenge the status quo of distribution system operations. Advanced Distribution Management System (ADMS) technologies are being increasingly deployed to manage the complexities of operating distribution systems. The ability to evaluate the ADMS applications in specific utility environments and for future scenarios will accelerate wider adoption of the ADMS and will lower the risks and costs of their implementation. This paper addresses the first step - identify and define the use cases for evaluating these applications. The applications that are selected for this discussion include Volt-VAr Optimization (VVO), Fault Location Isolation and Service Restoration (FLISR), Online Power Flow (OLPF)/Distribution System State Estimation (DSSE) and Market Participation. A technical description and general operational requirements for each of these applications is presented. The test scenarios that are most relevant to the utility challenges are also addressed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Local Phasor-Based Control of DER Inverters for Voltage Regulation on Distribution Feeders

We introduce a new control paradigm termed Phasor-Based Control (PBC) to coordinate Distributed Energy Resources (DER) for improved voltage regulation and other objectives. PBC is a multi-layer control framework where the state of the distribution grid is represented by voltage phasors, and Phasor Measurement Units (PMUs) measure the state at critical points in the distribution grid. In the PBC paradigm, a supervisory controller (S-PBC) sets phasor targets which local controllers track. In this paper, we propose a Proportional Integral (PI) implementation for the local control layer (LPBC), to regulate real and reactive power output of distributed inverters to track a voltage phasor target computed by the supervisory layer. We tune the PI controller gains offline with a genetic algorithm that yields better performance than the Ziegler-Nichols method. We benchmark the proposed L-PBC controller against droop volt-var control (DVVC) and observe improved voltage regulation in simulation on the IEEE 13 node unbalanced test feeder (IEEE 13NF). Furthermore, by means of numerical simulation we observe the response of the L-PBC controllers to small and large grid disturbances. Simulations on larger feeders, IEEE 123-node and 647-node, demonstrate challenges with tuning controllers in setups with different amounts of power-voltage coupling.

42 ENGINEERING↗

Impacts of Inverter-Based Advanced Grid Support Functions on Islanding Detection

A long-standing requirement for inverters paired with distributed energy resources is that they are required to disconnect from the electrical power system (EPS) when an electrical island is formed. In recent years, advanced grid support controls have been developed for inverters to provide voltage and frequency support by integrating functions such as voltage and frequency ride-through, volt-VAr control, and frequency-Watt control. With these new capabilities integrated into the inverter, additional examination is needed to determine how voltage and frequency support will impact pre-existing inverter functions like island detection. This paper inspects how advanced inverter functions will impact its ability to detect the formation of an electrical island. Results are presented for the unintentional islanding laboratory tests of three common residential-scale photovoltaic inverters performing various combinations of grid support functions. For the inverters tested, grid support functions prolonged island disconnection times slightly; however, it was found that in all scenarios the inverters disconnected well within two seconds, the limit imposed by IEEE Std 1547-2003.

14 SOLAR ENERGY↗

Data-Driven Distribution System Coordinated PV Inverter Control Using Deep Reinforcement Learning

The deployment of distributed solar photovoltaic (PV) systems has increased consistently over the past decades. High penetrations of PVs could cause a series of adverse grid impacts, such as voltage violations. The recent development of smart inverter technologies rises the incentives of developing PV control solutions that regulate the inverter output power and seeking the optimization on system operational objectives. This paper proposes a data-driven control solution based on deep reinforcement learning (DRL) to optimize PV inverters for voltage regulation. The proposed solution can minimize PV real power curtailment while maintaining network voltage at an acceptable range. Comparison results between the proposed DRL control algorithms with deep deterministic policy gradient (DDPG) and volt-var control on a real feeder in west Colorado highlight the advantage of the proposed framework in controlling the system voltage while minimizing the PV real power curtailment.

deep reinforcement learning↗

Interconnection Standard Grid-Support Function Evaluations Using an Automated Hardware-in-the-Loop Testbed

Grid operators are increasingly turning to advanced grid-support functions in distributed energy resources (DER) to assist with distribution circuit voltage regulation, bulk system frequency control, and power system protection. The U.S. DER certification standard, Underwriters Laboratories (UL) 1741, was revised in September 2016 to add test procedures for multiple grid-support functions. Sandia National Laboratories, SunSpec Alliance, and growing community of collaborators have undertaken a multiyear effort to create an open-source system validation platform (SVP) that automates DER interconnection and interoperability test procedures by communicating with grid simulators, photovoltaic (PV) simulators, data acquisition systems, and interoperable equipment under test. However, the power hardware required for generating the test conditions may be untenable for many organizations. In this paper, we discuss development of the SVP testing capabilities for UL 1741 tests utilizing a controller hardware-in-the-loop testbed that precludes the need for power hardware using a 34.5 kW Austrian Institute of Technology smart grid controller. Finally, analysis of normal ramp rate, soft start ramp rate, specified power factor, volt-VAr, and frequency-watt advanced grid functions, and the effectiveness of the UL 1741 test protocols are included.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Federated Deep Reinforcement Learning for Decentralized VVO of BTM DERs

The future of grid control requires a hybrid approach combining centralized and decentralized methods to fully utilize the potential of smart edge devices with artificial intelligence (AI) capabilities. This paper aims to develop and evaluate a federated deep reinforcement learning (FDRL) framework for decentralized adaptive volt-var optimization (VVO) of behind-the-meter (BTM) distributed energy resources (DERs). First, this paper models a single deep reinforcement learning (DRL) agent using the Markov Decision Process (MDP) framework for decentralized adaptive VVO of BTM DERs. Two DRL algorithms, soft actor-critic (SAC) and twin-delayed deep deterministic policy gradient (TD3), are compared for their effectiveness in optimizing VVO. Results show that TD3 outperforms SAC, achieving a 71.3% improvement in mean reward. Finally, the DRL agent is deployed within the FDRL framework, using the Flower platform, to enhance learning, provide adaptive control, and ensure data privacy for BTM DERs.

Ravi, Abhijith↗

Extremum Seeking Control of Smart Inverters for VAR Compensation

Reactive power compensation is used by utilities to ensure customer voltages are within pre-defined tolerances and reduce system resistive losses. While much attention has been paid to model-based control algorithms for reactive power support and Volt Var Optimization (VVO), these strategies typically require relatively large communications capabilities and accurate models. In this work, a non-model-based control strategy for smart inverters is considered for VAR compensation. An Extremum Seeking control algorithm is applied to modulate the reactive power output of inverters based on real power information from the feeder substation, without an explicit feeder model. Simulation results using utility demand information confirm the ability of the control algorithm to inject VARs to minimize feeder head real power consumption. In addition, we show that the algorithm is capable of improving feeder voltage profiles and reducing reactive power supplied by the distribution substation.

Arnold, Daniel↗

A Measurement-Based Adaptive Voltage Regulation Method Considering Topology Changes

This paper proposes an online adaptive data-driven distributed energy resource (DER) dispatch optimization method for voltage control considering topology changes. By using a local sensitivity factor (LSF)-enabled voltage control, traditional DER control can be reformulated into a linear programming (LP) problem, leading to faster computation speeds. Power injection alteration and topology changes are two common operational changes in the distribution network that can affect the LSF and voltage control performance. To address this issue, a robust estimation method is developed to adjust the sensitivity matrix at each time step for the time-varying power injection changes. When topology changes occur, only the allocated predominant LSF submatrices are updated based on measurement data, allowing for a fast adaptation to the system reconfiguration. Results obtained from a real distribution feeder in Southern California demonstrate its robustness as compared to traditional volt-var control and constant LSF matrix dispatch control methods.

DERs↗

Volt/VAR Optimization (VVO) Application on GridAPPS-D Platform

There is a large increment in the distributed energy resources (DERs) installation and deployments of smart sensing devices and communication infrastructure; hence, the power distribution network is swiftly evolving from a passive network to an active network. This motivates the development of advanced applications to operate power distribution systems for higher efficiency and reliability. These advanced applications are model-based and data-driven. This requires an advanced distribution management system (ADMS) to provide required data for the optimal operation of the distribution systems by coordinating various grid controllable devices. In this paper a Volt-VAR optimization (VVO) application to coordinate the grid’s legacy and new voltage control devices for conservation voltage reduction (CVR) is deployed on the GridAPPS-D platform (an open-source platform ) for ADMS application development. The VVO application is validated for various operating conditions on using modified IEEE 8500-node distribution test feeders. Further, the application is successfully deployed on the GridAPPS-D platform.

Jha, Rahul↗

GridAPPS-D™ a distribution management platform to develop applications for rural electric utilities

Rural electric utilities, many of which operate with a co-op management approach, have unique operational challenges not shared with their municipal or IOU counterparts. Rural electric utilities typically have fewer customers per feeder mile, and are generally less able to afford the costs, or provide robust support for today’s Advanced Distribution Management System (ADMS) offerings. Additionally, co-ops typically do not need the full suite of ADMS offerings but would benefit from a subset of applications such as OMS, Unbalanced Power-Flow, Volt-VAR optimization and FLISR (Fault Location Isolation and Service Restoration). Their needs, even within these applications, are simpler and more standardized. Lastly, due to their size, their IT capabilities and resources are commonly limited; hence hardware and software needs to be standards-based and easy to maintain with only most expansions of current capabilities. GridAPPS-D™ is an open-source, application development environment that’s part of the Department of Energy’s Grid Modernization Efforts, being led by the Pacific Northwest National Laboratory. The GridAPPS-D project is developing a reference architecture and implementation with the goal of reducing the time and cost to integrate distribution applications for both planning and operations through the use of standardized interfaces and data models. In this paper, we present a view of the reference architecture for GridAPPS-D and highlight its applicability to the rural electric utilities’ needs, including descriptions of applications being developed using this platform, and how they can be applied to other rural electric utilities.

distribution management, GridAPPS-D, rural electri↗

An Extensible Software and Communication Platform for Distributed Energy Resource Management

This paper introduces a novel Distributed Extensible Grid Control (DEGC) software and communication platform to facilitate the control of distributed energy resources on electric grids. The DEGC software platform leverages state-of-the-art advances in secure, distributed communication and decentralized authorization and authentication. We discuss how these advances enable the kind of robust and secure communication required for a distributed grid control platform, and show how DEGC applies these technologies to the agile development and deployment of grid software through an extensible and flexible API. Here, we describe how DEGC can implement both Volt-VAR voltage magnitude control and Phasor-Based Control as sample applications and demonstrate the DEGC platform in hardware with the demanding Phasor-Based Control test case, and provide performance metrics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dual Inductor Hybrid Converter for Point-of-Load Voltage Regulator Modules

Achieving high-efficiency power conversion with high power density for large conversion ratio is crucially needed yet challenging in point-of-load applications because of increasing demands of loads. This paper presents a new hybrid converter to address this need. The converter uses two interleaved inductors for complete soft charging of flying capacitors to efficiently provide high output currents with no capacitor hard-charge loss. This dual inductor hybrid (DIH) converter features a smaller number of switches and more effective switch utilization than a recently reported Hybrid Dickson converter, yielding substantially less switch losses represented by smaller volt-ampere products and smaller equivalent output resistance. Converter operation principle is analyzed in detail to confirm the feasibility and benefits, and design considerations are provided to identify a practical design process. Experimental results verify the converter's operation principles and advantages with a 300-kHz 20-W prototype achieving 95.02% peak efficiency and 225 W/in 3 power density. Its advantages and performance promise a good candidate point-of-load converter architecture for demanding applications, such as in data centers, telecommunication, and high-performance digital systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Two-Stage Approach for PV Inverter Engagement in Power Factor Correction and Voltage Regulation

The rapid integration of distributed energy resources, like solar photovoltaics (PVs), can lead to overvolt-age challenges due to reverse power flow and a noticeable decrease in power factor at the substation interface. While existing literature extensively explores utilizing smart inverter capabilities for reactive power flexibility using a volt-var curve (VVC), obtaining time-varying operating points of such curves in real-time is challenging due to computational demands and communication requirements. Similarly, employing optimization-based approaches for reactive power control and active voltage regulation in large-scale distribution feeders is difficult due to the complexity of the problem and the challenges in effectively engaging customer-owned resources. This paper proposes a two-stage strategy to harness smart inverters for reactive power support. The first stage formulates short-term planning by optimally designing VVCs (on a daily or hourly basis) for large-scale solar PVs based on projected system needs and communicating optimal curves to smart inverters in advance. Subsequently, the second stage employs a transactive-based method to involve customer-owned PVs for reactive power support, effectively enhancing overall system performance and addressing real-time demands. In conclusion, the efficacy of this approach will be demonstrated using real-world distribution circuits provided by Vermont Electric Power Company (VELCO) and Vermont Electric Cooperative (VEC).

Poudel, Shiva [Pacific Northwest National Laborato↗

Integrating Nano-patterned Ferromagnetic and Ferroelectric Thin Films for Electrically Tunable RF Applications

Tunable radio frequency (RF) components are pivotal elements in frequency-agile and multifunctional systems. However, there is a technical barrier to achieve miniaturized fully electrically tunable RF components. This paper provides and demonstrates the efficacy of a first unique design methodology in developing fully electrically tunable RF components by integrating ferromagnetic (e.g., Permalloy) and ferroelectric (e.g., Lead Zirconate Titanate: PZT) thin films patterns. Permalloy thin film has been patterned in nanometer scale to improve its ferromagnetic resonance frequency (FMR) for RF applications. Tunable inductors are developed with the utilization of different thickness of Permalloy thin film, which show over 50% increment in inductance and over 4% in tunability with DC current. More tunability can be achieved with multiple layers of Permalloy thin film and optimized thickness. A fully electrically tunable slow wave RF transmission line with simultaneously variable inductance and capacitance density has been implemented and thoroughly investigated for the first time. Measured results show that a fixed phase shift of 90° can be achieved from 1.5 GHz to 1.85 GHz continuously by applying external DC current from 0 to 200 mA and external DC voltage from 0 to 15 Volts, respectively.

47 OTHER INSTRUMENTATION↗

Review of Challenges and Research Opportunities for Voltage Control in Smart Grids

In this report, we review the emerging challenges and research opportunities for voltage control in smart grids. For transmission grids, the voltage control for accommodating wind and solar power, fault-induced delayed voltage recovery (FIDVR), and measurement-based Th´evenin equivalent for voltage stability analysis are reviewed. For distribution grids, the impact of high penetration of distributed energy resources (DER) is analyzed, typical control strategies are reviewed, and the challenges for local inverter Volt-Var control is discussed. Furthermore, the motivation, state-of-art, and future directions of the coordination of transmission system operators (TSO) and distribution system operators (DSO) are also thoroughly discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Global Sensitivity Analysis of Large Distribution System with PVs using Deep Gaussian Process

Global sensitivity analysis (GSA) of the voltage to uncertain power injection variations plays an important role for appropriate Volt-VAR optimization. This paper proposes a data-driven GSA method for large-scale distribution systems with a large number of uncertain sources. Specifically, the deep Gaussian process is used to identify the mapping relationship between uncertain power injections and voltages. This allows us to resort to the analysis of variance framework to calculate the Sobol indices for GSA. Unlike the existing polynomial chaos expansion and Gaussian process-based approaches, our proposed method has much better scalability. Test results on the EPRI 1747-node K1 circuit with a different number and different probability distributions of uncertain sources demonstrate that the proposed method can achieve accurate GSA under various conditions.

14 SOLAR ENERGY↗

Analysis of 0.1-Hz Var Oscillations in Solar Photovoltaic Power Plants

Oscillations with very low frequency at 0.1 Hz, have been observed in voltage and var in practical solar photovoltaic (PV) systems when power exporting ramps up to a certain level. Here, this letter provides an explanation on the formation of 0.1-Hz oscillations and identifies three critical factors that lead to the oscillations: communication delay between the plant-level control and the inverter-level control, high volt/var sensitivity at a high power exporting level, and the volt-var feedback system consisting of the plant control, inverter control and the grid impact. Furthermore, a critical feature of the 0.1-Hz oscillation is also explained: why oscillations appear only in voltage and var, but not in real power.

14 SOLAR ENERGY↗

Toward the origins of binding energy shifts and “satellites” formation during plasma-XPS measurements

In-plasma x-ray photoelectron spectroscopy (plasma-XPS) emerges as a powerful platform for real-time, in situ chemical analysis under conditions relevant to semiconductor processing and other plasma-enabled technologies. This study investigates the origins of binding energy (BE) shifts and the formation of “satellite” peaks observed during plasma-XPS measurements across conductive, dielectric, and gas-phase systems. Using a standard laboratory-based ambient pressure XPS apparatus coupled with an alternating current (AC)-driven capacitively coupled plasma source, we demonstrate that metastable surface species, such as transient Au oxides, can be detected during plasma exposure, revealing chemical states that are hardly accessible using conventional ultrahigh vacuum (UHV) XPS. In dielectric samples (e.g., undoped diamond, sapphire), we observe pressure- and plasma-type-dependent BE shifts of more than 50 eV, attributed to x-ray-induced and plasma-mediated surface charging. These shifts are mitigated at higher pressures/plasmas or in electronegative plasmas (e.g., O 2 ), the latter due to enhanced charge compensation mechanisms involving slow negative ions. For gas-phase species, AC-plasma excitation leads to spectral broadening and the emergence of “satellite” peaks with energy separations of a few electron volts, linked to oscillating local plasma potentials in the probing volume. Furthermore, these findings highlight the complex and important interplay between plasma parameters, surface charging, and local electric fields in shaping XPS spectra. Overall, plasma-XPS emerges as a critical metrological tool for probing transient surface chemistry, with implications for semiconductor processing, material synthesis, and plasma diagnostics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗