Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Field Testing Unvented Roofs with Asphalt Shingles in Cold and Hot-Humid Climates

Insulating roofs with dense-pack cellulose (instead of spray foam) has moisture risks, but is a lower cost approach. If moisture risks could be addressed, buildings could benefit from retrofit options, and the ability to bring HVAC systems within the conditioned space. Test houses with unvented roof assemblies were built to measure long-term moisture performance, in the Chicago area (5A) and the Houston area (2A). The Chicago-area test bed had seven experimental rafter bays, including a control vented compact roof, and six unvented roof variants with cellulose or fiberglass insulation. The interior was run at 50% RH. All roofs except the vented cathedral assembly experienced wood moisture contents and RH levels high enough to constitute failure. Disassembly at the end of the experiment showed that the unvented fiberglass roofs had wet sheathing and mold growth. In contrast, the cellulose roofs only had slight issues, such as rusted fasteners and sheathing grain raise. The Houston-area roof was an unvented attic insulated with spray-applied fiberglass. Most ridges and hips were built with a diffusion vent detail, capped with vapor permeable roof membrane. Some ridge sections were built as a conventional unvented roof, as a control. In the control unvented roofs, roof peak RHs reached high levels in the first winter; as exterior conditions warmed, RHs quickly fell. In contrast, the diffusion vent roofs had drier conditions at the roof peak in wintertime, but during the summer, RHs and MCs were higher than the unvented roof (albeit in the safe range).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

WTP Waste Feed Qualification: Hydrogen Generation Rate Measurement Apparatus Testing Report

The generation rate of hydrogen gas in the Hanford tank waste will be measured during the qualification of the staged tank waste for processing in the Hanford Tank Waste Treatment and Immobilization Plant. Based on a review of past practices in measurement of the hydrogen generation, an apparatus to perform this measurement has been designed and tested for use during waste feed qualification. The hydrogen generation rate measurement apparatus (HGRMA) described in this document utilized a 100 milliliter sample in a continuously-purged, continuously-stirred vessel, with measurement of hydrogen concentration in the vent gas. The vessel and lid had a combined 220 milliliters of headspace. The vent gas system included a small condenser to prevent excessive evaporative losses from the sample during the test, as well as a demister and filter to prevent particle migration from the sample to the gas chromatography system. The gas chromatograph was an on line automated instrument with a large-volume sample-injection system to allow measurement of very low hydrogen concentrations. This instrument automatically sampled the vent gas from the hydrogen generation rate measurement apparatus every five minutes and performed data regression in real time. The fabrication of the hydrogen generation rate measurement apparatus was in accordance with twenty three (23) design requirements documented in the conceptual design package, as well as seven (7) required developmental activities documented in the task plan associated with this work scope. The HGRMA was initially tested for proof of concept with physical simulants, and a remote demonstration of the system was performed in the Savannah River National Laboratory Shielded Cells Mockup Facility. Final verification testing was performed using non-radioactive simulants of the Hanford tank waste. Three different simulants were tested to bound the expected rheological properties expected during waste feed qualification testing. These simulants were tested at different temperatures using purge gas spiked with varying amounts of hydrogen to provide verification that the system could accurately measure the hydrogen in the vent gas at steady state.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pollutant Concentrations and Emission Rates from Scripted Natural Gas Cooking Burner Use in Nine Northern California Homes

METHODS: Combustion pollutant concentrations were measured during the scripted operation of natural gas cooking burners in nine homes. In addition to a base condition of closed windows, no forced air unit (FAU) use, and no mechanical exhaust, additional experiments were conducted while operating an FAU and/or vented range hood. Test homes included a 26m2 two-room apartment, a 134m2 first floor flat, and seven detached homes of 117–226m2. There were four single-story, four two-story and one 1.5 story homes. Cooktop use entailed boiling and simmering activities, using water as a heat sink. Oven and broiler use also were simulated. Time-resolved concentrations of carbon dioxide (CO2), nitric oxide (NO), nitrogen oxides (NOX), nitrogen dioxide (NO2), particles with diameters of 6 nm or larger (PN), carbon monoxide (CO), and fine particulate matter (PM2.5) were measured in the kitchen (K) and bedroom area (BR) of each home. CO2, NO, NO2, and PN data from sequential experiments were analyzed to quantify the contribution of burner use to the highest 1h and 4h time-integrated concentrations in each room. RESULTS: Four of the nine homes had kitchen 1h NO2 exceed the national ambient air quality standard (100 ppb). Two other homes had 1h NO2 exceed 50 ppb in the kitchen, and three had 1h NO2 above 50 ppb in the bedroom, suggesting substantial exposures to anyone at home when burners are used for a single substantial event. In all homes, the highest 1h kitchen PN exceeded 2 x105 cm-3-h, and the highest 4h PN exceeded 3 x105 cm-3-hr in all homes. The lowest 1h kitchen/bedroom ratios were 1.3–2.1 for NO in the apartment and two open floor plan homes. The largest K/BR ratios of 1h NO2 were in a two-story 1990s home retrofitted for deep energy savings: ratios in this home were 3.3 to 6.6. Kitchen 1h ratios of NO, NO2 and PN to CO2 were used to calculate fuel normalized emission factors (ng J-1). Range hood use substantially reduced cooking burner pollutant concentrations both in the kitchen and bedroom of several homes. A hood with large capture volume and a measured flow of 108 L/s reduced concentrations 80-95%. IMPLICATIONS: These measurements demonstrate that operation of natural gas cooking burners without venting can cause short-term kitchen concentrations of NO2 to exceed the US outdoor health standard, and can elevate concentrations of NO, NO2, and ultrafine particles throughout the home. Results are generally consistent with a recent simulation study that estimated widespread 1h NO2 exposures exceeding 100 ppb in homes that use gas burners without venting. While operating a venting range hood can greatly reduce pollutant levels from burner use (and presumably from cooking as well), performance varies widely across hoods. Increased awareness of the need to ventilate when cooking would substantially reduce in-home exposure to NO2 and ultrafine particles in California homes. Helping consumers select effective hoods, for example by publishing capture efficiency performance ratings, also would help reduce exposure.

54 ENVIRONMENTAL SCIENCES↗

Field Testing Unvented Roofs with Asphalt Shingles in Cold and Hot-humid Climates

BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Cold Climates - Bolingbrook, IL 60440 BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Hot-Humid Climates - Friendswood, TX 77546 To understand the long-term moisture performance of unvented roof assemblies with fibrous insulation, the U.S. Department of Energy's Building America team Building Science Corporation built and monitored test roofs in two climates: a cold-climate test house in Bolingbrook, Illinois (Chicago area; zone 5A), and a hot-humid test house in Friendswood, Texas (Houston area, zone 2A). The Chicago-area test bed had seven parallel experimental rafter bays. The assemblies included a control vented compact (cathedral) roof, a dense-pack cellulose unvented roof, and an unvented roof with a "diffusion vent" (a strip of vapor-permeable gypsum sheathing at the ridge to allow drying). The interior finish was gypsum wallboard (GWB) with latex paint. The other four bays were top vent roof assemblies, which have a polypropylene breather mesh between the roof sheathing and the asphalt shingles to allow ventilation drying of the assembly from underneath the vapor-impermeable shingles. Two of the four "top vent" roofs were fiberglass batt and two were dense-pack cellulose roofs with either interior GWB or open to the interior. Wintertime moisture-related failure was accelerated by providing interior humidification (22.2 degree C [72 degree F]/50% relative humidity [RH]), which is known to be an extreme interior loading). Data were captured over 8 months, including a winter and the following spring and early summer.

Array↗

Evaluation of Crawlspace Retrofits in Multifamily Buildings

In 2011 and early 2012, Building Science Corporation (BSC) collaborated with Innova Services Corporation on a multifamily community un-vented crawlspace retrofit project at Oakwood Gardens in Lansdale, Pennsylvania. BSC provided design consulting services and pre- and post-retrofit evaluation, testing, and data monitoring.The existing condition was a vented crawlspace with an un-insulated floor between the crawlspace and the dwelling units above. The crawlspace was therefore a critically weak link in the building enclosure and was ripe for improvement. Saving energy was the primary interest and goal, but the greatest challenge in this un-vented crawlspace retrofit project was working through a crawlspace bulk water intrusion problem caused by inadequate site drainage, window well drainage, foundation wall drainage, and a rising water table during rainy periods.While the un-vented crawlspace retrofit was effective in reducing heat loss, and the majority of the bulk water drainage problems had been resolved, the important finding was that some of the wood joists embedded in masonry pockets behind the brick veneer were showing signs of moisture damage.

affordable housing↗

Zero Power Warming (ZPW) Chamber Prototype Measurements, Utqiagvik (Barrow), Alaska, 2016

Data were collected during one season of prototyping associated with the development of a passive warming technology. An experimental chamber, the Zero Power Warming (ZPW) chamber, was fitted with apparatus to modulate venting of a field enclosure and enhance elevation of air temperature by solar radiation. The ZPW chamber was compared with a control chamber (Control) and an ambient open air plot (Ambient). The control chamber was identical to the ZPW chamber but lacked the apparatus necessary to modulate venting, the chamber vents in the control chamber were fixed open for the majority of the trial period. The three plots were located over Carex aquatilis growing in an area of moderately degraded permafrost. Chambers were placed on the same footprints that were used for a similar exercise in 2015 (no data) and therefore those plots had experienced some thaw and degradation prior to 2016. The following data were collected for 80 days at 1 minute intervals from within two chambers and an ambient plot: solar input, chamber venting, air temperature, relative humidity, soil temperature (at 5, 10 and 15 cm), soil moisture, downward and upward NIR. CO2 concentration within the chambers and of the ambient air plot was collected at 1 minute intervals over a 62 hour period in the middle of the growing season. This dataset contains six csv files and one pdf file.The documentation may refer to a ZPW-metadata.xlsx file. This file was split into two csv files: ZPW-metadata.csv and ZPW-metadata-instrumentation.csv.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Thermal/structural optimization of cryogenic storage systems.

An analytical method has been developed to optimize a cryogenic storage system designed for long term storage of cryogenic propellants. The type of propellant, mission duration, thermal environment, insulation thermal properties, insulation vent time, and the storage system weight penalty imposed by the design pressure were considered as the dependent parameters. The optimum system insulation thickness and vent pressure were then calculated in terms of these parameters. The method was applied to the design of the Space Shuttle Orbiter oxygen and hydrogen tanks to obtain an optimum design. It was determined that for the mission examined, the hydrogen tank optimum design was close to the initial pressure. A continuously vented hydrogen tank, therefore, was close to the optimum design. Also, it was determined that for this particular mission the oxygen tank should not be vented.

Navickas, J.↗

Centaur Propellant Thermal Conditioning Study

A wicking investigation revealed that passive thermal conditioning was feasible and provided considerable weight advantage over active systems using throttled vent fluid in a Centaur D-1s launch vehicle. Experimental wicking correlations were obtained using empirical revisions to the analytical flow model. Thermal subcoolers were evaluated parametrically as a function of tank pressure and NPSP. Results showed that the RL10 category I engine was the best candidate for boost pump replacement and the option showing the lowest weight penalty employed passively cooled acquisition devices, thermal subcoolers, dry ducts between burns and pumping of subcooler coolant back into the tank. A mixing correlation was identified for sizing the thermodynamic vent system mixer. Worst case mixing requirements were determined by surveying Centaur D-1T, D-1S, IUS, and space tug vehicles. Vent system sizing was based upon worst case requirements. Thermodynamic vent system/mixer weights were determined for each vehicle.

Blatt, M. H.↗

The mineralogy and the isotopic composition of sulfur in hydrothermal sulfide/sulfate deposits on the East Pacific Rise, 21 deg N latitude

The mineralogy and isotopic composition of sulfur found in hydrothermal deposits associated with five groups of vents along the ridge axis of the East Pacific Rise near 21 deg N latitude are investigated. Solid samples of mixed sulfides and sulfates from mounds, chimneys and the surrounding sediment as well as fresh basaltic glass were examined with a portable X-ray fluorescence spectrometer and by scanning electron microscopy, X-ray diffractometry, and electron microprobe analysis. For the three vents of exit temperature close to 350 C, the chimneys are found to be rich in copper sulfides, while for those of temperatures around 300 C, zinc sulfide is found to predominate. The major sulfides found in the chimneys include wurtzite, chalcopyrite, pyrite and cubanite, with anhydrite the dominant sulfate. Significant mineralogical differences are found between active and inactive vents. The isotopic composition of sulfur in anhydrites from active vents is observed to be close to that of sea water and consistent with a derivation from sea water sulfate. The isotopic composition of sulfur in the sulfide minerals is explained in terms of precipitation from solutions with reduced sulfur derived from basalts or basaltic magmas, and sea water sulfate. Finally, the deposits are interpreted as the results of the mixing of H2S-dominated hydrothermal fluids with cold sea water near the sea floor.

Styrt, M. M.↗

Liquid/Gas Vortex Separator

Liquid/gas separator vents gas from tank of liquid that contains gas randomly distributed in bubbles. Centrifugal force separates liquid and gas, forcing liquid out of vortex tube through venturi tube. Gas vented through exhaust port. When liquid detected in vent tube, exhaust port closed, and liquid/gas mixture in vent tube drawn back into tank through venturi.

Morris, B. G.↗

Submarine hot springs and the origin of life

The popular hypothesis that life originally arose in hydrothermal vents at oceanic ridge crests is examined. It is shown that the high temperatures in the vents would not allow synthesis of organic compounds, but would decompose them, unless the exposure time at vent temperature was short. Even if the essential organic molecules were available in the hot hydrothermal waters, the subsequent steps of polymerization and the conversion of these polymers into the first organisms would not occur as the vent waters were quenched to the colder temperatures of the primitive oceans.

Miller, Stanley L.↗

Independent Orbiter Assessment (IOA): Analysis of the atmospheric revitalization pressure control subsystem

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis/Critical Items List (FMEA/CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The independent analysis results corresponding to the Orbiter Atmospheric Revitalization and Pressure Control Subsystem (ARPCS) are documented. The ARPCS hardware was categorized into the following subdivisions: (1) Atmospheric Make-up and Control (including the Auxiliary Oxygen Assembly, Oxygen Assembly, and Nitrogen Assembly); and (2) Atmospheric Vent and Control (including the Positive Relief Vent Assembly, Negative Relief Vent Assembly, and Cabin Vent Assembly). The IOA analysis process utilized available ARPCS hardware drawings and schematics for defining hardware assemblies, components, and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode.

Saiidi, M. J.↗

Chemical environments of submarine hydrothermal systems

Perhaps because black-smoker chimneys make tremendous subjects for magazine covers, the proposal that submarine hydrothermal systems were involved in the origin of life has caused many investigators to focus on the eye-catching hydrothermal vents. In much the same way that tourists rush to watch the spectacular eruptions of Old Faithful geyser with little regard for the hydrology of the Yellowstone basin, attention is focused on the spectacular, high-temperature hydrothermal vents to the near exclusion of the enormous underlying hydrothermal systems. Nevertheless, the magnitude and complexity of geologic structures, heat flow, and hydrologic parameters which characterize the geyser basins at Yellowstone also characterize submarine hydrothermal systems. However, in the submarine systems the scale can be considerably more vast. Like Old Faithful, submarine hydrothermal vents have a spectacular quality, but they are only one fascinating aspect of enormous geologic systems operating at seafloor spreading centers throughout all of the ocean basins. A critical study of the possible role of hydrothermal processes in the origin of life should include the full spectrum of probable environments. The goals of this chapter are to synthesize diverse information about the inorganic geochemistry of submarine hydrothermal systems, assemble a description of the fundamental physical and chemical attributes of these systems, and consider the implications of high-temperature, fluid-driven processes for organic synthesis. Information about submarine hydrothermal systems comes from many directions. Measurements made directly on venting fluids provide useful, but remarkably limited, clues about processes operating at depth. The oceanic crust has been drilled to approximately 2.0 km depth providing many other pieces of information, but drilling technology has not allowed the bore holes and core samples to reach the maximum depths to which aqueous fluids circulate in oceanic crust. Such determinations rely on studies of pieces of deep oceanic crust uplifted by tectonic forces such as along the Southwest Indian Ridge, or more complete sections of oceanic crust called ophiolite sequences which are presently exposed on continents owing to tectonic emplacement. Much of what is thought to happen in submarine hydrothermal systems is inferred from studies of ophiolite sequences, and especially from the better-exposed ophiolites in Oman, Cyprus and North America. The focus of much that follows is on a few general features: pressure, temperature, oxidation states, fluid composition and mineral alteration, because these features will control whether organic synthesis can occur in hydrothermal systems.

Shock, Everett L.↗

Lava flow-field morphological classification and interpretation: Examples from Venus

Recent analyses suggest that thermal constraints will act to limit the maximum length of an advancing lava flow being fed at a given volume or mass effusion rate from a vent. These constraints can be characterized through the Gratz number, which has a large value at the vent and decreases down flow; under a wide range of conditions, motion apparently ceases when the Gratz number has decreased to a value close to 300. In cooling-limited flows, effusion from the vent should be steady; the flow front thickens, eventually stops due to this cooling, and the central channel does not drain. If the vent remains active, a break-out flow will form from some point on the margin of the initial flow unit. If flows on planetary surfaces can be shown to be cooling limited, eruption rates can be estimated. In this analysis, we illustrate the morphological characteristics of various flow configurations, and we describe the application of these concepts to a flow length histogram for a hypothetical flow field and then apply this to an example on Venus.

Head, J. W.↗

Crystallization history of the 1984 Mauna Loa lava flow

During a 3-week eruption in 1984, Mauna Loa produced vent lavas that increased in crystallinity from less than 1 to 30%, and 27-km-long flows that increased in crystallinity as they moved downstream. We examined the crystallization history of these lavas using crystal size distribution (CSD) analysis to study the rates of crystallization, viscosity increase, and latent heating. Typical average growth and nucleation rates were 5 x 10(exp -9) cm/s and 5/cu cm/s for microphenocrysts (20- to 500-micron size crystals nucleated in the rift zone) and 5 x 10(exp -8) cm/s and 5 x 10(exp 4)/cu cm/s for microlites (1- to 20-micron size crystals nucleated in the channel). These crystallization rates are high compared with those found in other CSD studies of igneous rocks, probably due to highly nonequilibrium conditions brought on by rapid degassing in the rift zone and cooling in the lava channel. Growth and nucleation rates decreased with time at the vent and with distance downstream. The maximum downstream total crystallinity measured is 39% (25% microlites, 14% microphenocrysts) in a quenched sample 14 km from the vent. Growth and nucleation rates cannot be calculated for postemplacement samples, but they place upper limits of 53-58% on the amount of crystallization in the channel 9-20 km from the vent. Crystallization could have been mostly responsible for the 10(exp 5)-fold downstream increase in apparent viscosity, although degassing and increasing incorporation of solid lava fragments also contributed. Another effect of crystallization on the lava flow was the sizeable latent heating (0.01 J/g/s over the first half of the flow length, if the crystallinity of downstream quench samples is representative of the hot fluid core), which may have been counteracted by entrainment of cooler material. Measurements of crystallization are shown to be crucial in the study of lava flow emplacement dynamics.

Crisp, Joe↗

Effect of pressure on a burning solid in low-gravity

Venting, or depressurization, has been discussed as a possible technique for extinguishing fires on aircraft and spacecraft. Fire suppression plans for the International Space Station Alpha (ISSA) discuss the use of depressurization as a method for extinguishing fires. In the case of an uncontrollable fire, the affected compartment would be vented from an initial pressure of 1.0 atm (14.7 psia) to a final pressure 0.33 atm (4.8 psia) within 10 minutes. However, the lack of low pressure flammability data for solid materials in a low-gravity environment presents an uncertainty for the use of the venting technique. There are also transient effects that need to be considered. It is possible that the flows induced by the venting could intensify the fire. This occurred during flammability tests conducted on board Skylab. In addition, the extinction pressure could be a function of the depressurization rate. Studies conducted with solid propellants have shown that if the pressure is reduced quickly enough, the pressure at extinction will be greater than the steady-state extinction limit. This project, which was started in 1992, is examining both the quasi steady-state and transient effects of pressure reduction on a burning solid in low-gravity. This research will provide low-g extinguishment data upon which policies and practices can be formulated for fire safety in orbiting spacecraft.

Goldmeer, Jeffrey S.↗

Sulfur, Chlorine, and Flourine Degassing and Atmospheric Loading by the 1783 - 1784 AD Laki (Skaftar Fires) Eruption in Iceland

The 1783-1784 Laki tholeiitic basalt fissure eruption in Iceland was one of the greatest atmospheric pollution events of the past 250 years, with widespread effects in the northern hemisphere. The degassing history and volatile budget of this event are determined by measurements of pre-eruption and residual contents of sulfur, chlorine, and fluorine in the products of all phases of the eruption. In fissure eruptions such as Laki, degassing occurs in two stages: by explosive activity or lava fountaining at the vents, and from the lava as it flows away from the vents. Using the measured sulfur concentrations in glass inclusions in phenocrysts and in groundmass glasses of quenched eruption products, we calculate that the total accumulative atmospheric mass loading of sulfur dioxide was 122 Mt over a period of 8 months. This volatile release is sufficient to have generated approximately 250 Mt of H2SO4 aerosols, an amount which agrees with an independent estimate of the Laki aerosol yield based on atmospheric turbidity measurements. Most of this volatile mass (approximately 60 wt.%) was released during the first 1.5 months of activity. The measured chlorine and fluorine concentrations in the samples indicate that the atmospheric loading of hydrochloric acid and hydrofluoric acid was approximately 7.0 and 15.0 Mt, respectively. Furthermore, approximately 75% of the volatile mass dissolved by the Laki magma was released at the vents and carried by eruption columns to altitudes between 6 and 13 km. The high degree of degassing at the vents is attributed to development of a separated two-phase flow in the upper magma conduit, and implies that high-discharge basaltic eruptions such as Laki are able to loft huge quantities of gas to altitudes where the resulting aerosols can reside for months, or even 1-2 years. The atmospheric volatile contribution due to subsequent degassing of the Laki lava flow is only 18 wt.% of the total dissolved in the magma, and these emissions were confined to the lowest regions of the troposhere and therefore important only over Iceland. This study indicates that determination of the amount of sulfur degassed from the Laki magma batch by measurements of sulfur in the volcanic products (the petrologic method) yields a result which is sufficient to account for the mass of aerosols estimated by other methods.

Thordarson, T.↗

Preventing Damaging Pressure Gradients at the Walls of an Inflatable Space System

An inflatable structural system to deploy a space system such as a solar shield, an antenna or another similar instrument, requires a stiffening element after it is extended by the inflated gas pressure. The stiffening element has to be packaged in a folded configuration before the deployment. It must be relatively small, lightweight, non-damaging to the inflated system, and be able to become stiff in a short time. One stiffening method is to use a flexible material inserted in the deployable system, which, upon a temperature curing, can become stiff and is capable to support the entire structure. There are two conditions during the space operations when the inflated volume could be damaged: during the transonic region of the launch phase and when the curing of the rigidizing element occurs. In both cases, an excess of pressure within the volume containing the rigid element could burst the walls of the low-pressure gas inflated portion of the system. This paper investigates those two conditions and indicates the vents, which will prevent those damaging overpressures. Vent openings at the non-inflated volumes have been calculated for the conditions existing during the launch. Those vents allow the initially folded volume to exhaust the trapped atmospheric gas at approximately the same rate as the ambient pressure drops. That will prevent pressure gradients across the container walls which otherwise could be as high as 14.7 psi. The other condition occurring during the curing of the stiffening element has been investigated. This has required the testing of the element to obtain the gas generation during the curing and the transformation from a pliable material to a rigid one. The tested material is a composite graphite/epoxy weave. The outgassing of the uncured sample at 121C was carried with the Cahn Microbalance and with other outgassing facilities including the micro-CVCM ASTM E-595 facility. The tests provided the mass of gas evolved during the test. That data, including the chemical nature of the evolved gas, provided the data for the calculation of the pressure produced within the volume. The evaluation of the areas of the vents that would prevent excessive pressures and provide a rapid release of the gas away from contamination sensitive surfaces has been carried out. The pressure decay with time has been indicated.

Scialdone, John J.↗